  <doc>
    <id>5799</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferencepresentation</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Linking flow conditions in membrane oxygenators to arrangements of multimeric von-Willebrand-factor as indication for coagulation</title>
    <abstract language="eng">Introduction&#13;
Shear induced multimerisation of von-Willebrand-factor (vWF) is supposed to play an important role in coagulation inside extracorporeal membrane oxygenators. However, there is no proof that links observed vWF structures to computed or measured flow conditions.&#13;
&#13;
Methods&#13;
The structures of multimeric vWF fibers, observed in clinically used membrane oxygenators is examined using immunofluorescence microscopy (IFM) using Carstairs’ staining method (positive ethics committee vote). The flow around the membrane fibres inside the oxygenator is investigated in terms of shear rate, wall shear velocity and streamlines by using CFD (RANS, Carreau-Yasuda viscosity, geometry remodelled after high-resolution µCT-scans). By interpreting the histological and numerical results in this common context, indications for shear induced coagulation mechanisms can be identified.&#13;
&#13;
Results&#13;
The fibre structures of multimeric vWF build regular but not exactly symmetric formations around the contact face (CF) between the crosswise stacked oxygenator fibres (OF), see fig.1B, vWF marked red. Annular around the CF arranged, cells are likely to be found, see fig.1B, nuclei marked blue. &#13;
The computed streamlines around the OF show attached flow around the circular fibres. However, the irregular arrangement of real OF produce considerable cross flow between the interconnected neighbouring channels, in contrast to previous 2D-simulations. Thus, the CF are washed around closely by blood, also from neighbouring channels. The wall shear velocity streamlines form regular, slightly asymmetric shapes around the contact faces. The occurring maximum shear rates are in the range of 1,000 1/s.&#13;
Discussion&#13;
The shapes of vWF structures found in clinically used oxygenators match the computational results in terms of wall shear velocity and streamlines well. The accumulation of cells close to the CF can also be explained by fluid mechanics, as there are small shear gradients and slow velocities. However, occurring shear rates between OFs are too low to trigger multimerisation of vWF. That raises the question where in the circuit the actual activation of vWF is started and how, at least partly chained, vWF multimeres are attracted towards the OF surface. A next step will be the investigation of the actual shear rate triggered (or mediated) multimerisation of vWF. Towards this end, microfluidic experiments with shear triggered coagulation will be performed. Also of big interest is the computation of the flow situation in the oxygenator in proximity to chaining threads, which have been ignored in computations so far. However, first a realistic representation of the effective viscosity in computations is needed, which is not available yet.</abstract>
    <parentTitle language="eng">World Congress of Biomechanics 2018, Convention Centre Dublin, 8.-12. Juli 2018</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Clemens Birkenmaier</author>
    <author>Lars Krenkel</author>
    <author>Karla Lehle</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>319</id>
    <completedYear/>
    <publishedYear>2011</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>2384</pageFirst>
    <pageLast>2386</pageLast>
    <pageNumber/>
    <edition/>
    <issue>6</issue>
    <volume>22</volume>
    <type>article</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-18</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage</title>
    <abstract language="eng">A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry.</abstract>
    <parentTitle language="eng">The Journal of craniofacial surgery</parentTitle>
    <identifier type="doi">10.1097/SCS.0b013e318231fc8d</identifier>
    <author>J.C. Roldán</author>
    <author>A. Moralis</author>
    <author>Sebastian Dendorfer</author>
    <author>J. Witte</author>
    <author>C. Reicheneder</author>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Mund-Kiefer-Gesichts-Chirurgie</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Le Fort III</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>distraction</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>vector</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>anchorage</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>three-dimensional computed tomography analysis</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Distraktion</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Knochenbildung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Osteotomie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Dreidimensionale Bildverarbeitung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Computertomografie</value>
    </subject>
    <collection role="ddc" number="617">Chirurgie und verwandte medizinische Fachrichtungen</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>3491</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>CIMNE</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Convolutional Neural Networks for Approximation of Internal Non-Newtonian Multiphase Flow Fields</title>
    <abstract language="eng">Neural networks (NNs) as an alternative method for universal approximation of differential equations have proven to be computationally efficient and still sufficiently accurate compared to established methods such as the finite volume method (FVM). Additionally, analysing weights and biases can give insights into the underlying physical laws. FVM and NNs are both based upon spacial discretisation. Since a Cartesian and equidistant grid is a raster graphics, image-to-image regression techniques can be used to predict phase velocity fields as well as particle and pressure distributions from simple mass flow boundary conditions. The impact of convolution layer depth and number of channels of a ConvolutionDeconvolution Regression Network (CDRN), on prediction performance of internal non-Newtownian multiphase flows is investigated. Parametric training data with 2055 sets is computed using FVM. To capture significant non-Newtownian effects of a particle-laden fluid (e.g. blood) flowing through small and non-straight channels, an Euler-Euler multiphase approach is used. The FVM results are normalized and mapped onto an equidistant grid as supervised learning target. The investigated NNs consist of n= {3, 5, 7} corresponding encoding/decoding blocks and different skip connections. Regardless of the convolution depth (i.e. number of blocks), the deepest spacial down-sampling via strided convolution is adjusted to result in a 1 × 1 × f · 2nfeature map, with f = {8, 16, 32}. The prediction performance expressed is as channel-averaged normalized root mean squared error (NRMSE). With a NRMSE of &lt; 2 · 10-3, the best preforming NN has f = 32 initial feature maps, a kernel size of k = 4, n = 5 blocks and dense skip connections. Average inference time from this NN takes &lt; 7 · 10-3s. Worst accuracy at NRMSE of approx 9 · 10-3is achieved without any skips, at k = 2, f = 16 and n = 3, but deployment takes only &lt; 2 · 10-3s Given an adequate training, the prediction accuracy improves with convolution depth, where more features have higher impact on deeper NNs. Due to skip connections and batch normalisation, training is similarly efficient, regardless of the depth. This is further improved by blocks with dense connections, but at the price of a drastically larger model. Depending on geometrical complexity, spacial resolution is critical, as it increases the number of learnables and memory requirements massively.</abstract>
    <parentTitle language="eng">14th World Congress on Computational Mechanics (WCCM), ECCOMAS Congress 2020: 19–24 July 2020, Paris, France</parentTitle>
    <identifier type="doi">10.23967/wccm-eccomas.2020.107</identifier>
    <enrichment key="opus.import.date">2022-04-10T10:02:46+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Creative Commons - CC BY-NC-SA - Namensnennung - Nicht kommerziell -  Weitergabe unter gleichen Bedingungen 4.0 International</licence>
    <author>Clemens Birkenmaier</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Deep Learning</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Convolutional neural networks</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Non-Newtonian multiphase flow</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="krenkellbfmconf">Krenkel, Lars (Prof. Dr.), Präsentationen - Labor Biofluidmechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>3164</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>10</pageLast>
    <pageNumber/>
    <edition/>
    <issue>6</issue>
    <volume>13</volume>
    <type>article</type>
    <publisherName>PLOS</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice</title>
    <abstract language="eng">Over the past decade, veno-venous extracorporeal membrane oxygenation (vvECMO) has been increasingly utilized in respiratory failure in patients. This study presents our institution´s experience focusing on the life span of ECMO systems reflecting the performance of a particular system. A retrospective review of our ECMO database identified 461 adult patients undergoing vvECMO (2010-2017). Patients that required more than one system and survived the first exchange &gt;24 hours (n = 139) were included. Life span until the first exchange and exchange criteria were analyzed for all systems (PLS, Cardiohelp HLS-set, both Maquet Cardiopulmonary, Rastatt, Germany; Deltastream/Hilite7000LT, iLA-activve, Xenios/NovaLung, Heilbronn, Germany; ECC.O5, LivaNova, Mirandola, Italy). At our ECMO center, the frequency of a system exchange was 30%. The median (IQR) life span was 9 (6-12) days. There was no difference regarding the different systems (p = 0.145 and p = 0.108, respectively). However, the Deltastream systems were exchanged more frequently due to elective technical complications (e. g. worsened gas transfer, development of coagulation disorder, increased bleedings complications) compared to the other exchanged systems (p = 0.013). In summary, the used ECMO systems are safe and effective for acute respiratory failure. There is no evidence for the usage of a specific system. Only the increased predictability of an imminent exchange preferred the usage of a Deltastream system. However, the decision to use a particular system should not depend solely on the possible criteria for an exchange.</abstract>
    <parentTitle language="eng">PLOS ONE</parentTitle>
    <identifier type="doi">10.1371/journal.pone.0198392</identifier>
    <enrichment key="opus.import.date">2022-03-17T06:33:09+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Alois Philipp</author>
    <author>Filip de Somer</author>
    <author>Maik Foltan</author>
    <author>Andre Bredthauer</author>
    <author>Lars Krenkel</author>
    <author>Florian Zeman</author>
    <author>Karla Lehle</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Equipment Failure Analysis/statistics &amp; numerical data</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Extracorporeal Membrane Oxygenation/instrumentation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Membrane/classification/standards/statistics &amp; numerical data</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Primary Health Care/statistics &amp; numerical data</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Respiratory Distress Syndrome/therapy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Retrospective Studies</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Severity of Illness Index</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Time factors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MULTIDETECTOR COMPUTED-TOMOGRAPHY</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>THROMBOTIC DEPOSITS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ECMO SYSTEMS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Flow</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>OXYGENATION</value>
    </subject>
    <collection role="ddc" number="610">Medizin und Gesundheit</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5319</id>
    <completedYear/>
    <publishedYear>2012</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>report</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Investigation of the impact of vortex generators on the shock/boundary-layer interaction</title>
    <abstract language="eng">Comprehensive experimental and numerical parameter studies on the impact of isolated vortex generator pairs and complex vortex generator arrays onto a strong shock-/boundary layer interaction are presented within the context of this thesis. The effects of vortices, especially as they interact with each other are discussed in terms of their impact on the boundary layer development, the shock characteristics and the overall aerodynamic performance of the aerofoil. The presented results have been obtained from wind tunnel experiments with a simple flat plate with superimposed pressure gradient as well as with a more comprehensive model of a supercritical transonic aerofoil. In addition complex numerical parameter studies on a supercritical aerofoil in free stream conditions have been conducted. This work is designed for gaining a better understanding of the fundamental mechanisms of vortex generator/shock/boundary-layer interaction in order to achieve improved flight performance in terms of drag reduction, avoidance or at least postponement of separation onset and shock oscillation as well as lift improvement by application of optimised vortex generator configurations.</abstract>
    <additionalTitle language="deu">Untersuchung des Einflusses von Wirbelgeneratoren auf die Stoss-/Grenzschicht-Wechselwirkung</additionalTitle>
    <identifier type="url">https://www.osti.gov/etdeweb/biblio/22059657</identifier>
    <identifier type="issn">1434-8454</identifier>
    <enrichment key="opus.import.date">2022-08-24T10:21:08+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="OtherSeries">DLR-Forschungsbericht. DLR-FB-2012-10</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>42 ENGINEERING</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>BOUNDARY LAYERS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>COMPUTERIZED SIMULATION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FLOW COUNTERS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FLOW MODELS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FLUID MECHANICS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>TRANSONIC FLOW</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>WIND TUNNELS</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>3302</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>192</pageFirst>
    <pageLast>200</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>12</volume>
    <type>article</type>
    <publisherName>Bentham</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Controllable Magnetoactive Polymer Conduit</title>
    <abstract language="eng">Objective: &#13;
Magneto-active Polymers (MAP) are smart materials whose mechanical characteristics, such as elastic and shear moduli, may be controllable by means of an externally applied magnetic field.&#13;
&#13;
Methods: &#13;
Various additives may be used to influence the characteristics of the polymer matrix whilst a suspension of soft and/or hard magnetic particles determine the magnetic properties of the composite. Both pre-cure and post-cure magnetization is possible.&#13;
&#13;
Results:&#13;
A range of control strategies have been investigated for evaluation of the system using fluids of differing kinematic viscosity.&#13;
&#13;
Conclusion: &#13;
Depending on the degree of magnetic field homogeneity, magneto-deformation and magnetostriction contribute to MAP actuation. This paper presents a novel application in the form of a peristaltic MAP tube system, applicable to flow control and pumping of hemorheological fluids in blood circulatory systems for biomedical research purposes.</abstract>
    <parentTitle language="eng">The Open Mechanical Engineering Journal</parentTitle>
    <identifier type="url">https://www.benthamopen.com/ABSTRACT/TOMEJ-12-192</identifier>
    <note>Corresponding authro: Gareth J. Monkman</note>
    <enrichment key="opus.import.date">2022-03-29T06:25:40+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Andreas Diermeier</author>
    <author>Dirk Sindersberger</author>
    <author>Lars Krenkel</author>
    <author>X. C. Rosell</author>
    <author>Gareth J. Monkman</author>
    <collection role="institutes" number="FakEI">Fakultät Elektro- und Informationstechnik</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16312">Energie und Mobilität</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="institutes" number="">Mechatronics Research Unit (MRU)</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5399</id>
    <completedYear/>
    <publishedYear>2011</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>107</pageFirst>
    <pageLast>128</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>116</volume>
    <type>bookpart</type>
    <publisherName>Springer</publisherName>
    <publisherPlace>Berlin, Heidelberg</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Magnetic Resonance Imaging and Computational Fluid Dynamics of High Frequency Oscillatory Ventilation (HFOV)</title>
    <abstract language="eng">In order to better understand the mechanisms of gas transport during High Frequency Oscillatory Ventilation (HFOV) Magnetic Resonance Imaging (MRI) with contrast gases and numerical flow simulations based on Computational Fluid Dynamics(CFD) methods are performed. Validation of these new techniques is conducted by comparing the results obtained with simplified models of the trachea and a first lung bifurcation as well as in a cast model of the upper central airways with results achieved from conventional fluid mechanical measurement techniques like e.g. Laser Doppler Anemometry (LDA). Further it is demonstrated that MRI of experimental HFOV is feasible and that Hyperpolarized 3He allows for imaging the gas re-distribution inside the lung. Finally, numerical results of oscillatory flow in a 3rd generation model of the lung as well as the impact of endotracheal tubes on the flow regime development in a trachea model are presented.</abstract>
    <parentTitle language="eng">Fundamental Medical and Engineering Investigations on Protective Artificial Respiration</parentTitle>
    <identifier type="isbn">978-3-642-20325-1</identifier>
    <identifier type="doi">10.1007/978-3-642-20326-8_7</identifier>
    <identifier type="old">978-3-642-20326-8</identifier>
    <enrichment key="opus.import.date">2022-08-24T10:21:08+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="OtherSeries">Notes on Numerical Fluid Mechanics and Multidisciplinary Design ; 116</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Alexander-Wigbert K. Scholz</author>
    <author>Lars Krenkel</author>
    <author>Maxim Terekhov</author>
    <author>Janet Friedrich</author>
    <author>Julien Rivoire</author>
    <author>Rainer Köbrich</author>
    <author>Ursula Wolf</author>
    <author>Daniel Kalthoff</author>
    <author>Matthias David</author>
    <author>Claus Wagner</author>
    <author>Laura Maria Schreiber</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Central Airway</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>computational fluid dynamics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Computational Fluid Dynamics Simulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser Doppler Anemometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Magnetic Resonance Imaging Measurement</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16311">Digitalisierung</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmbeitr">Krenkel, Lars (Prof. Dr.), Beitraege - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5800</id>
    <completedYear/>
    <publishedYear>2019</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>workingpaper</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients?</title>
    <abstract language="eng">Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots—in particular, the presence of von Willebrand factor (vWF)—may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti‐vWF and anti‐P‐selectin) and counterstained with 4′,6‐diamidino‐2‐phenylindole. The extent of vWF‐loading was correlated with patient and technical data. While 12 MOs showed low vWF‐loadings, 9 MOs showed high vWF‐loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF‐fibers/“cobwebs,” leukocytes, platelet–leukocyte aggregates (PLAs), and P‐selectin‐positive platelet aggregates were independent of the extent of vWF‐loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high‐molecular‐weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.</abstract>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Tamara Steiger</author>
    <author>Maik Foltan</author>
    <author>Alois Philipp</author>
    <author>Thomas Müller</author>
    <author>Michael Gruber</author>
    <author>Andre Bredthauer</author>
    <author>Lars Krenkel</author>
    <author>Clemens Birkenmaier</author>
    <author>Karla Lehle</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5914</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>559</pageFirst>
    <pageLast>568</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Springer Nature Switzerland AG</publisherName>
    <publisherPlace>Cham, Switzerland</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-03-17</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Generation and Distribution of Surgical Smoke During High Frequency Electrocauterization</title>
    <abstract language="eng">Surgical Smoke is generated during the cauterization of tissue with high-frequency (HF) devices and consists of 95% water vapor and 5% cellular debris. When the coagulation tweezers, which are supplied with HF voltage by the HF device, touch tissue, the electric circuit is closed, and smoke is generated by the heat. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during coagulation of tissue. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. With higher power of the HF device, the particles generated are larger in size and the total number of particles generated is also higher. Adding artificial saliva to the tissue shows even higher particle counts. The study by laser light sheet also confirms this. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms considering the risk arising from surgical smoke. Furthermore, the experiments will provide the database for further numerical investigations.</abstract>
    <parentTitle language="eng">New Results in Numerical and Experimental Fluid Mechanics XIV. STAB/DGLR Symposium 2022</parentTitle>
    <identifier type="doi">10.1007/978-3-031-40482-5_53</identifier>
    <identifier type="isbn">978-3-031-40481-8</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="OtherSeries">Notes on Numerical Fluid Mechanics and Multidisciplinary Design ; 154</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Vera Stelzer</author>
    <author>Sandra Melina Tauwald</author>
    <author>Veronika Vielsmeier</author>
    <author>Fabian Cieplik</author>
    <author>Arne Kandulski</author>
    <author>Wulf Schneider-Brachert</author>
    <author>Olaf Wünsch</author>
    <author>Markus Rütten</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Surgical smoke</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluid Mechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Aerosols</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tracheotomies</value>
    </subject>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmbeitr">Krenkel, Lars (Prof. Dr.), Beitraege - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5398</id>
    <completedYear/>
    <publishedYear>2010</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>555</pageFirst>
    <pageLast>562</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>bookpart</type>
    <publisherName>Springer Berlin Heidelberg</publisherName>
    <publisherPlace>Berlin, Heidelberg</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Vortex-Generator Pairs for Vortex-Induced Heat-Transfer Enhancement in Heat-Exchanger Channels</title>
    <abstract language="eng">The objective of the presented work is to investigate possibilities for increasing the heattransfer in heat-exchanger channels for aircraft applications by using flow-manipulating devices. Focal point of the investigation are different arrangements of vortex-generator pairs within a generic heat-exchanger channel. The DLR URANS CFD solver THETA has been used to carry out numerical simulations of the laminar flow within a rectangular channel with integrated vortex generators. In particular, the analysis of the interaction of generated vortices with the stratified thermal boundary layer, the impact of vortical flow structures on heated walls and the enforced mixed-convection flow is of special interest. The final goal is the evaluation of the applicability of oppositely arranged vortex-generator pairs for the enhancement of vortex-induced heat-transfer.</abstract>
    <parentTitle language="eng">New Results in Numerical and Experimental Fluid Mechanics VII : Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008</parentTitle>
    <identifier type="isbn">978-3-642-14242-0</identifier>
    <identifier type="doi">10.1007/978-3-642-14243-7_68</identifier>
    <identifier type="isbn">978-3-642-14243-7</identifier>
    <enrichment key="opus.import.date">2022-08-24T10:21:08+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="OtherSeries">Notes on Numerical Fluid Mechanics and Multidisciplinary Design ; 112</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Markus Rütten</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Heat Exchanger</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Heat Transfer</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Heated Wall</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Thermal Boundary Layer</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Vortex Generator</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmbeitr">Krenkel, Lars (Prof. Dr.), Beitraege - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5320</id>
    <completedYear/>
    <publishedYear>2012</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>book</type>
    <publisherName>Rheinisch-Westfälische Technische Hochschule Aachen</publisherName>
    <publisherPlace>Aachen</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Untersuchung des Einflusses von Wirbelgeneratoren auf die Stoß-/Grenzschicht-Wechselwirkung</title>
    <abstract language="deu">Im Rahmen dieser Arbeit werden experimentelle und numerische Parameterstudien von einzelnen Wirbelgeneratorpaaren und komplexeren Wirbelgeneratoranordnungen bezüglich ihres Einflusses auf eine starke Stoß-/Grenzschicht-Wechselwirkung vorgestellt. Dabei werden die Einflüsse von Wirbeln, insbesondere die Auswirkungen ihrer Wechselwirkungen untereinander, auf das Grenzschichtverhalten, die Stoßcharakteristik und insgesamt auf die aerodynamische Leistung des betrachteten Profils diskutiert. Dazu wurden sowohl Windkanalversuche am einfachen Modell einer ebenen Platte mit aufgeprägtem Druckgradienten sowie an einem Modell eines superkritischen transsonischen Profils durchgeführt. Ergänzend wurden komplexe nume-rische Parameteruntersuchungen an einem Profil in freier Anströmung ausgeführt. Es ist das Ziel, ein besse-res Verständnis der Mechanismen der Wirbelgenerator-/Stoß-/Grenzschicht-Wechselwirkung zu gewinnen, um durch optimierte Anwendung von Wirbelgeneratoren eine Verbesserung der Flugleistungen erzielen zu können. Die Schwerpunkte liegen dabei auf der Reduktion des Widerstandes, der Vermeidung bzw. Verzöge-rung von Strömungsablösung und Stoßschwingung sowie auf der Erhöhung des Auftriebs.</abstract>
    <identifier type="url">https://elib.dlr.de/78972/</identifier>
    <identifier type="issn">1434-8454</identifier>
    <enrichment key="opus.import.date">2022-08-24T10:21:08+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Lars Krenkel</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>CFD</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Numerische Simulation</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Stoß-/Grenzschicht-Wechselwirkung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Strömungsablösung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Strömungssteuerung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>transsonische Strömung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Verdichtungsstoß</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Windkanal</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Wirbelgeneratoren</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5391</id>
    <completedYear/>
    <publishedYear>2010</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>107</pageFirst>
    <pageLast>114</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>TUDpress</publisherName>
    <publisherPlace>Dresden</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Optimierung der Hochfrequenz-Oszillationsventilation mittels strömungsmechanischer Methoden und kontrastgasgestützter Magnetresonanztomografie - Teilprojekt: Rekonstruktion von Geometrien aus medizinischen Bilddaten und Erstellung von Modellen für experimentelle Strömungsuntersuchungen</title>
    <abstract language="deu">Der vorliegende Artikel skizziert die neu entwickelte Prozesskette für detailgenaue Rekonstruktion von Geometrien anhand medizinischer Bilddaten sowie die Herstellung von transparenten Modellen für experimentelle Untersuchungen mit bildgebenden Strömungsmessverfahren. Die Geometriedaten und Modelle werden für systematische Untersuchungen der komplexen Transportvorgänge in den Atemwegen bei künstlicher Beatmung mittels Hochfrequenzoszillationsventilation (HFOV) verwendet.</abstract>
    <parentTitle language="deu">Laseranwendung in der Medizin, Erfassen und Verarbeiten kardiovaskulärer Signale, protektive Beatmungskonzepte : 3. Dresdner Medizintechnik-Symposium - mit DFG-Forschungsschwerpunkt Protektive Beatmungskonzepte, 6. bis 9. Dezember 2010, Dresden</parentTitle>
    <identifier type="isbn">978-3-942710-02-2</identifier>
    <identifier type="url">https://elib.dlr.de/66863/</identifier>
    <enrichment key="opus.import.date">2022-08-24T10:21:08+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="OtherSeries">Dresdner Beiträge zur Medizintechnik ; 10</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Lars Krenkel</author>
    <author>Julien Pennecot</author>
    <author>Christian Lenz</author>
    <author>Daniel Feldmann</author>
    <author>Claus Wagner</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="persons" number="krenkellbfmconf">Krenkel, Lars (Prof. Dr.), Präsentationen - Labor Biofluidmechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5794</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferencepresentation</type>
    <publisherName/>
    <publisherPlace>Göttingen</publisherPlace>
    <creatingCorporation>Deutsche Gesellschaft für Luft- und Raumfahrt e.V. / Arbeitsgemeinschaft Strömungen mit Ablösung, AG STAB</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">High Spatial Resolution Tomo-PIV of the Nasopharynx Focussing on the Physiological Breathing Cycle</title>
    <abstract language="eng">Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark&#13;
of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person’s head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras‘ double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field.</abstract>
    <parentTitle language="deu">23. DGLR Fach-Symposium Strömungen mit Ablösung, 09./10. November 2022, Berlin, Deutschland</parentTitle>
    <identifier type="url">https://www.dlr.de/as/Portaldata/5/Resources/dokumente/veranstaltungen/stab_workshop/Jahresbericht2022.pdf</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">begutachtet</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Sandra Melina Tauwald</author>
    <author>Maurizio Quadrio</author>
    <author>Markus Rütten</author>
    <author>Christian Stemmer</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tomographic PIV</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Flow visualisation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Physiological Breathing</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nasal airflow</value>
    </subject>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="krenkellbfmconf">Krenkel, Lars (Prof. Dr.), Präsentationen - Labor Biofluidmechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
  </doc>