    <title language="eng">An Integrative Experimental Approach to Design Optimization and Removal Strategies of Supporting Structures Used during L-PBF of SS316L Aortic Stents</title>
    <abstract language="eng">One of the fundamental challenges in L-PBF of filigree geometries, such as aortic stents used in biomedical applications, is the requirement for a robust yet easily removable support structure that allows each component to be successfully fabricated without distortion. To solve this challenge, an integrative experimental approach was attempted in the present study by identifying an optimal support structure design and an optimized support removal strategy for this design. The specimens were manufactured using four different support structure designs based on the geometry exposed to the laser beam during the L-PBF. Support removal procedures included sand blasting (SB), glass bead blasting (GB), and electrochemical polishing (ECP). The two best-performing designs (line and cross) were chosen due to shorter lead times and lower material consumption. As an additional factor that indicates a stable design, the breaking load requirement to remove the support structures was determined. A modified line support with a 145° included angle was shown to be the best support structure design in terms of breaking load, material consumption, and manufacturing time. All three procedures were used to ensure residue-free support removal for this modified line support design, with ECP proving to be the most effective.</abstract>
    <parentTitle language="eng">Applied Sciences</parentTitle>
    <identifier type="doi">10.3390/app11199176</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-25612</identifier>
    <note>Corresponding author: Marius Grad</note>
    <enrichment key="opus.import.date">2022-01-27T15:19:14+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Marius Grad</author>
    <author>Naresh Nadammal</author>
    <author>Ulrich Schultheiss</author>
    <author>Philipp Lulla</author>
    <author>Ulf Noster</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="TCParsberg">Technologie-Campus Parsberg-Lupburg</collection>
    <collection role="institutes" number="">Labor Werkstoffrandschichtanalytik</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/2561/Grad_aorticstents.pdf</file>
  </doc>
  <doc>
    <id>5006</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>4</pageLast>
    <pageNumber/>
    <edition/>
    <issue>September</issue>
    <volume>15</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace>Amsterdam, Niederlande</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2022-07-27</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">On the nanoindentation behavior of a TiC layer formed through thermo-reactive diffusion during hot pressing of Ti and cast iron</title>
    <abstract language="eng">Hot pressing of pure Ti and cast iron under vacuum formed a ~15 μm wide TiC-layer through the thermoreactive diffusion process. Nanoindentation testing of the TiC-layer revealed average hardness and elastic&#13;
modulus values of ~35 GPa and ~400 GPa, respectively. High-resolution indentation mapping indicated hardness change across the boundary with peak values observed within the TiC-layer. Solid state high temperature diffusion holds significant potential for developing uniform hard coatings on pure Ti/Ti-alloys.</abstract>
    <parentTitle language="eng">Materials Letters: X</parentTitle>
    <identifier type="doi">10.1016/j.mlblux.2022.100161</identifier>
    <identifier type="issn">2590-1508</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-50066</identifier>
    <note>Corresponding author: Marius Grad</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="CorrespondingAuthor">Marius Grad</enrichment>
    <licence>Creative Commons - CC BY-NC-ND - Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International</licence>
    <author>Marius Grad</author>
    <author>Naresh Nadammal</author>
    <author>Darius Tytko</author>
    <author>Ulf Noster</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Titanium alloys</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Hard coating</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nanoindentation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electron backscatter diffraction</value>
    </subject>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="TCParsberg">Technologie-Campus Parsberg-Lupburg</collection>
    <collection role="institutes" number="">Labor Werkstoffrandschichtanalytik</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/5006/On_the_nanoindentation_behavior_of_TiC.pdf</file>
  </doc>
  <doc>
    <id>5535</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>26</pageLast>
    <pageNumber/>
    <edition/>
    <issue>21</issue>
    <volume>15</volume>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Potential of the Synthetic Fuel Oxymethylene Ether (OME) for the Usage in a Single-Cylinder Non-Road Diesel Engine: Thermodynamics and Emissions</title>
    <abstract language="eng">Non-road sectors, such as agriculture and construction machinery, require high energy densities and flexibility in use, which is why diesel engines are mainly used. The use of climate-neutral fuels, produced from renewable energies, such as Oxymethylene Ether (OME) as a diesel substitute, can significantly reduce CO2 and pollutant emissions in these sectors. In addition to CO2 neutrality, OME also offers improved combustion characteristics compared to diesel fuel, eliminating the soot–NOx trade-off and thus enabling new opportunities in engine design and calibration. In this paper, the combustion of pure OME on a close-to-production, single-cylinder non-road diesel engine with a pump–line–nozzle injection system is analyzed. A variation of the center of combustion at constant power output was performed for diesel and OME at different operating points. Two injectors were investigated with OME. A study on ignition delay and a detailed thermodynamic analysis was carried out. In addition, the exhaust emissions CO, NOx, VOC, as well as particulate-matter, -number and -size distributions were measured. With OME, a significantly shorter ignition delay as well as a shortened combustion duration could be observed, despite a longer injection duration. In addition, the maximum injection pressure increases. VOC and CO emissions are reduced. Particulate matter was reduced by more than 99% and particle number (&gt;10 nm) was reduced by multiple orders of magnitude. The median of the particle size distribution shifts from 60 to 85 nm (diesel) into a diameter range of sub 23 nm (OME). A significant reduction of NOx emissions with OME enables new degrees of freedom in engine calibration and an efficiency advantage without hardware adaption.</abstract>
    <parentTitle language="eng">Energies</parentTitle>
    <identifier type="doi">10.3390/en15217932</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-55350</identifier>
    <note>Project: NAMOSYN: Nachhaltige Mobilität durch synthetische Kraftstoffe (Funding Nr. 03SF0566N0)</note>
    <note>Corresponding author: Florian Zacherl</note>
    <enrichment key="opus.import.date">2022-10-28T17:12:32+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Florian Zacherl</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Florian Zacherl</author>
    <author>Christoph Wopper</author>
    <author>Peter Schwanzer</author>
    <author>Hans-Peter Rabl</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16312">Energie und Mobilität</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/5535/Zacherl_energies-15-07932-v2.pdf</file>
  </doc>
  <doc>
    <id>1471</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1615</pageFirst>
    <pageLast>1629</pageLast>
    <pageNumber/>
    <edition/>
    <issue>12</issue>
    <volume>51</volume>
    <type>article</type>
    <publisherName>Wiley</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Mechanical properties of small structures built by selective laser melting 316 L stainless steel – a phenomenological approach to improve component design</title>
    <abstract language="eng">Experimental investigations are conducted to quantify the influence of specimen thickness and orientation on the mechanical properties of selective laser melted stainless steel 316 L. The results indicate that the mechanical strength and ductility increase with increasing specimen thickness until a saturation value is reached from a specimen thickness of about 2 mm. Specimen orientation dependency is pronounced for thin specimens (&lt;1.5 mm), whereas only small deviations in strength are observed for thicker specimens with orientations of 30°, 45° and 90° to build direction. The mechanical properties of the specimen orientation of 0° to build direction shows great deviation to the other orientations and the smallest overall strength. A reliable design of selective laser melted components should account for specimen thickness and orientation, e. g. by a correction factor. Furthermore, it is recommended to avoid loads vertical (90°) and parallel (0°) to build direction to guarantee higher ductility and strength.</abstract>
    <parentTitle language="eng">Materials Science &amp; Engineering Technology</parentTitle>
    <parentTitle language="deu">Materialwissenschaft und Werkstofftechnik</parentTitle>
    <additionalTitle language="deu">Mechanische Eigenschaften von kleinen Strukturen aus selektiv lasergeschmolzenem 316 L Edelstahl – ein phänomenologischer Ansatz zur Verbesserung des Bauteildesigns</additionalTitle>
    <identifier type="doi">10.1002/mawe.202000038</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-14718</identifier>
    <note>Corresponding author: Lisa Wiesent</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Lisa Wiesent</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Lisa Wiesent</author>
    <author>Ulrich Schultheiß</author>
    <author>Philipp Lulla</author>
    <author>Aida Nonn</author>
    <author>Ulf Noster</author>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="TCNeustadt">Technologie-Campus Neustadt an der Donau</collection>
    <collection role="persons" number="nonncmm">Nonn, Aida (Prof. Dr.) - Computational Mechanics and Materials Lab</collection>
    <collection role="persons" number="tcnehno">Technologie-Campus Neustadt a. d. Donau (Prof. Ehrlich+ Prof. Nonn)</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">DEAL Wiley</collection>
    <collection role="institutes" number="TCParsberg">Technologie-Campus Parsberg-Lupburg</collection>
    <collection role="institutes" number="">Computational Mechanics and Materials Lab (CMM)</collection>
    <collection role="institutes" number="">Labor Werkstoffrandschichtanalytik</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/1471/Wiesent_Materialwissenschaft_Werkst_2020.pdf</file>
  </doc>
  <doc>
    <id>2320</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>8</pageLast>
    <pageNumber/>
    <edition/>
    <issue>15</issue>
    <volume>221</volume>
    <type>article</type>
    <publisherName>Wiley</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Shape memory effects using magnetoactive Boron-organo-silicon oxide polymers</title>
    <abstract language="eng">Thermomechanical shape memory materials have certain disadvantages when it comes to 3D volumetric reproduction intended for rapid prototyping or robotic prehension. The need to constantly supply energy to counteract elastic retraction forces in order to maintain the required geometry, together with the inability to achieve conformal stability at elevated temperatures, limits the application of thermal shape memory polymers. Form removal also presents problems as most viscoelastic materials do not ensure demolding stability. This work demonstrates how magnetoactive boron−organo−silicon oxide polymers under the influence of an applied magnetic field can be used to achieve energy free sustainable volumetric shape memory effects over extended periods. The rheopectic properties of boron−organo−silicon oxide materials sustain form removal without mold distortion.</abstract>
    <parentTitle language="eng">Macromolecular Chemistry and Physics</parentTitle>
    <identifier type="doi">10.1002/macp.202000149</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-23205</identifier>
    <note>Corresponding Author: Gareth J. Monkman</note>
    <enrichment key="opus.import.date">2022-01-14T10:19:11+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Nina Prem</author>
    <author>Dirk Sindersberger</author>
    <author>Birgit Striegl</author>
    <author>Valter Böhm</author>
    <author>Gareth J. Monkman</author>
    <collection role="institutes" number="FakEI">Fakultät Elektro- und Informationstechnik</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">DEAL Wiley</collection>
    <collection role="institutes" number="">Labor Finite-Elemente-Methode (FEM)</collection>
    <collection role="institutes" number="">Mechatronics Research Unit (MRU)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/2320/Prem_Macro_Chemistry_Physics.pdf</file>
  </doc>
  <doc>
    <id>6752</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>Sage</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-12-01</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Review of elasto-static models for three-dimensional analysis of thick-walled anisotropic tubes</title>
    <abstract language="eng">Most shell or beam models of anisotropic tubes under bending have no validity for thick-walled structures. As a result, the need to develop three-dimensional formulations which allow a change in the stress, strain and displacement distributions across the radial component arises. Basic formulations on three-dimensional anisotropic elasticity were made either stressor displacement-based by Lekhnitskii or Stroh on plates. Lekhnitskii also was the first to expand these analytical formulations to tubes under various loading conditions. This paper presents a review of the stress and strain analysis of tube models using three-dimensional anisotropic elasticity. The focus lies on layered structures, like fiber-reinforced plastics, under various bending loads, although the basic formulations and models regarding axisymmetric loads are briefly discussed. One section is also dedicated to the determination of an equivalent bending stiffness of tubes.</abstract>
    <parentTitle language="eng">Journal of Composite Materials</parentTitle>
    <identifier type="doi">10.1177/00219983231215863</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-67521</identifier>
    <note>Corresponding author: Andreas Kastenmeier</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="CorrespondingAuthor">Andreas Kastenmeier</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Andreas Kastenmeier</author>
    <author>Marco Siegl</author>
    <author>Ingo Ehrlich</author>
    <author>Norbert Gebbeken</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>composite tube bending</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>layered structrues</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>anisotropy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Analytical modelling</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>elasticity</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="persons" number="ehrlichlft">Ehrlich, Ingo (Prof. Dr.) - Labor Faserverbundtechnik</collection>
    <collection role="persons" number="tcnehno">Technologie-Campus Neustadt a. d. Donau (Prof. Ehrlich+ Prof. Nonn)</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Faserverbundtechnik (LFT)</collection>
    <collection role="funding" number="">Sage Publish&amp;Read-Vertrag</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/6752/kastenmeier_et_al_2023_review.pdf</file>
  </doc>
  <doc>
    <id>7035</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>14 S.</pageNumber>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>Springer Nature</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Test Setup for Investigating the Impact Behavior of Biaxially Prestressed Composite Laminates</title>
    <abstract language="eng">Instrumented impact testing and compression-after-impact testing are important to adequately qualify material behavior and safely design composite structures. However, the stresses to which fiber-reinforced plastic components are typically subjected in practice are not considered in the impact test methods recommended in guidelines or standards. In this paper, a test setup for investigating the impact behavior of composite specimens under plane uniaxial and biaxial preloading is presented. For this purpose, a special test setup consisting of a biaxial testing machine and a specially designed drop-weight tower was developed. The design decisions were derived from existing guidelines and standards with the aim of inducing barely visible impact damage in laminated carbon fiber-reinforced plastic specimens. Several measurement systems have been integrated into the setup to allow comprehensive observation of the impact event and specimen behavior. A feasibility test was performed with biaxially prestressed carbon fiber-reinforced plastic specimens in comparison with unstressed reference tests. The compressive-tensile prestressing resulted in lower maximum contact forces, higher maximum deflections, higher residual deflections and a different damage pattern, which was investigated by light microscopic analysis. Finally, the functionality of the experimental setup is discussed, and the results seem to indicate that the test setup and parameters were properly chosen to investigate the effect of prestresses on the impacts behavior of composite structures, in particular for barely visible subsequent damages.</abstract>
    <parentTitle language="eng">Experimental Techniques</parentTitle>
    <identifier type="issn">0732-8818</identifier>
    <identifier type="doi">10.1007/s40799-024-00701-4</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-70355</identifier>
    <note>Corresponding authors: Christian Pongratz und Ingo Ehrlich</note>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Christian Pongratz; Ingo Ehrlich</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Christian Pongratz</author>
    <author>Janek Tix</author>
    <author>Johannes Wolfrum</author>
    <author>Steffen Gerke</author>
    <author>Ingo Ehrlich</author>
    <author>Michael Brünig</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Mechanical Engineering</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Mechanics of Materials</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Faserverbundwerkstoff</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Schlagprüfung</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="TCNeustadt">Technologie-Campus Neustadt an der Donau</collection>
    <collection role="persons" number="ehrlichlft">Ehrlich, Ingo (Prof. Dr.) - Labor Faserverbundtechnik</collection>
    <collection role="persons" number="tcnehno">Technologie-Campus Neustadt a. d. Donau (Prof. Ehrlich+ Prof. Nonn)</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">DEAL Springer Nature</collection>
    <collection role="institutes" number="">Labor Faserverbundtechnik (LFT)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/7035/Pongratz_Ehrlich_Springer_2024.pdf</file>
  </doc>
  <doc>
    <id>7461</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>9</issue>
    <volume>14</volume>
    <type>article</type>
    <publisherName>MDPI AG</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Effect of Carbon Content on the Phase Composition, Microstructure and Mechanical Properties of the TiC Layer Formed in Hot-Pressed Titanium-Steel Composites</title>
    <abstract language="eng">During the hot pressing of pure titanium and different carbon steels in a temperature range of ϑ = 950–1050 °C, a compound layer up to dL≈10 μm thick is formed at the titanium–steel interface. With a higher carbon content of the used steel, the layer thickness increases. The carbon concentration within the layer is in the range of stoichiometry for TiC. Apart from TiC, no other phases can be detected by X-ray diffraction (XRD) measurements inside the formed layer. The calculation of the activation energy for the TiC layer formation is Q = 126.5–136.7 kJ mol−1 and is independent of the carbon content of the steel. The resulting microstructure has a grain size gradient, wherein the mechanical properties, such as hardness and Young‘s modulus, are almost constant. Statistical analysis using Response Surface Methodology (RSM) indicates that the carbon content of the steel has the most significant influence on layer thickness, followed by annealing temperature and annealing time. By selecting the appropriate carbon steel and the subsequent removal of the steel, it is possible to produce targeted TiC layers on titanium substrates, which holds enormous potential for this material in wear-intensive applications.</abstract>
    <parentTitle language="eng">Metals</parentTitle>
    <identifier type="issn">2075-4701</identifier>
    <identifier type="doi">10.3390/met14090959</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-74617</identifier>
    <note>Cooresponding author der OTH Regensburg: Marius Grad</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Marius Grad</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Marius Grad</author>
    <author>Jan Zentgraf</author>
    <author>Ulrich Schultheiss</author>
    <author>Lukas Esper</author>
    <author>Andreas Diemar</author>
    <author>Ulf Noster</author>
    <author>Lothar Spiess</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Werkstoffrandschichtanalytik</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/7461/grad_metals-14-00959.pdf</file>
  </doc>
  <doc>
    <id>5604</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>440</pageFirst>
    <pageLast>449</pageLast>
    <pageNumber/>
    <edition/>
    <issue>4</issue>
    <volume>76</volume>
    <type>article</type>
    <publisherName>Springer Nature</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2022-11-28</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Biomechanical assessment of the design and efficiency of occupational exoskeletons with the AnyBody Modeling System</title>
    <abstract language="eng">Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose.&#13;
&#13;
Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.</abstract>
    <parentTitle language="eng">Zeitschrift für Arbeitswissenschaften</parentTitle>
    <identifier type="doi">10.1007/s41449-022-00336-4</identifier>
    <note>Corresponding author: Sebastian Dendorfer</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="CorrespondingAuthor">Sebastian Dendorfer</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Simon Auer</author>
    <author>Jonas Schiebl</author>
    <author>Kristoffer Iversen</author>
    <author>Divyaksh Subhash Chander</author>
    <author>Michael Damsgaard</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biomechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ergonomics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Motion capture</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Inverse dynamics</value>
    </subject>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">DEAL Springer Nature</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/5604/Dendorfer_Zs_f_Arbeitswiss.pdf</file>
  </doc>
  <doc>
    <id>5481</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1356</pageFirst>
    <pageLast>1364</pageLast>
    <pageNumber/>
    <edition/>
    <issue>6</issue>
    <volume>41</volume>
    <type>article</type>
    <publisherName>Wiley</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2022-10-10</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Musculoskeletal simulation of elbow stability for common injury patterns</title>
    <abstract language="eng">Elbow stability is derived from a combination of muscular, ligamentous, and bony structures. After an elbow trauma the stability of the joint is an important decision criterion for the subsequent treatment. The decision regarding non-operative/operative care depends mostly on subjective assessments of medical experts. Therefore, the aim of this study is to use musculoskeletal simulations as an objective assessment tool to investigate the extent to which failure of different stabilizers affects the elbow stability and how these observations correspond to the assessment from clinical practice. A musculoskeletal elbow simulation model was developed for this aim. To investigate the stability of the elbow, varus/valgus moments were applied under 0°, 45°and 90° flexion while the respective cubital angle was analyzed. This was performed for nine different injury scenarios, which were also evaluated for stability by clinical experts. With the results, it can be determined by which injury pattern and under which flexion angle the elbow stability is impaired regarding varus/valgus moments. The scenario with a complete failure of the medial and lateral ligaments and a fracture of the radial head was identified as having the greatest instability. The study presented a numerical determination of elbow stability against varus/valgus moments regarding clinical injury patterns, as well as a comparison of the numerical outcome with experience gained in clinical practice. The numerical predictions agree well with the assessments of the clinical specialists. Thus, the results from musculoskeletal simulation can make an important contribution to a more objective assessment of the elbow stability.</abstract>
    <parentTitle language="eng">Journal of Orthopaedic Research</parentTitle>
    <identifier type="doi">10.1002/jor.25460</identifier>
    <identifier type="issn">1554-527X</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-54819</identifier>
    <note>Corresponding author: Maximilian Melzner</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="CorrespondingAuthor">Maximilian Melzner</enrichment>
    <licence>Creative Commons - CC BY-NC-ND - Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International</licence>
    <author>Maximilian Melzner</author>
    <author>Christian Pfeiffer</author>
    <author>Franz Suess</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>AnyBody</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>musculoskeletal simulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>elbow stability</value>
    </subject>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">DEAL Wiley</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/5481/Melzner_Journal-Orthopaedic_Research.pdf</file>
  </doc>
  <doc>
    <id>5821</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>4</issue>
    <volume>23</volume>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace>Basel</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Correlation of Acceleration Curves in Gravitational Direction for Different Body Segments during High-Impact Jumping Exercises</title>
    <abstract language="eng">Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83–0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20–0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs.</abstract>
    <parentTitle language="eng">sensors</parentTitle>
    <identifier type="doi">10.3390/s23042276</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-58217</identifier>
    <note>Corresponding author: Lukas Reinker</note>
    <note>This work was supported by the Bavarian Academic Forum [BayWISS-Verbundkolleg Gesundheit] and the DHZK fond for behavioral cardiovascular diseases [Behaviorale kardiovaskuläre Erkrankungen; grand number: 81Z0400105].</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Lukas Reinker</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Lukas Reinker</author>
    <author>Dominic Bläsing</author>
    <author>Rudolf Bierl</author>
    <author>Sabina Ulbricht</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>osteoporosis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>inertial measurement units</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>wearable motion-tracking sensors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>high-impact exercisess</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/5821/reinker_sensors-23-02276-v2.pdf</file>
  </doc>
  <doc>
    <id>6511</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>1</pageFirst>
    <pageLast>6</pageLast>
    <pageNumber/>
    <edition/>
    <issue>11</issue>
    <volume>52</volume>
    <type>article</type>
    <publisherName>Springer</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-10-02</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Kombinierter Einfluss von psychologischen und biomechanischen Faktoren auf die muskulären Belastungen beim Fußballspielen</title>
    <abstract language="eng">When mental stress and musculoskeletal loading interact, the risk for injury increases due to altered body kinematics and increased muscle tension. These changes can be detected with musculoskeletal models, and mental loading and stress must be analyzed at emotional, cognitive, and behavioral levels. To investigate these kinematic and loading changes under stress, competitive athletes were subjected to mental stress during highly dynamic movements, and musculoskeletal models were used to analyze the biomechanical loading. It was shown that under mental stress, independent of the subjective perception, a strong change in muscle forces can occur. Accordingly, competitive athletes should undergo screenings to assess individual movement patterns and promote general stress resilience.</abstract>
    <abstract language="deu">Für Fußballer:innen stellen muskuläre Verletzungen der unteren Extremitäten ein großes Problem dar. Ein Beispiel hierfür liefert die Nationalmannschaftsstürmerin Alexandra Popp, die aufgrund muskulärer Probleme das EM-Finale 2022 in Wembley kurzfristig verpasste. Oftmals stehen gerade hohe Anspannungssituationen in zeitlichem Zusammenhang mit Verletzungen, der Einfluss der psychischen Beanspruchung auf die biomechanischen Belastungen wird jedoch meist nur wenig beachtet.</abstract>
    <parentTitle language="deu">Die Orthopädie</parentTitle>
    <identifier type="doi">10.1007/s00132-023-04437-8</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-65113</identifier>
    <note>Corresponding author: Sebastian Dendorfer</note>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="CorrespondingAuthor">Sebastian Dendorfer</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Simon Auer</author>
    <author>Simone Kubowitsch</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Biologische Modelle</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Biomechanik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Leistungssportler</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Bewegung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Resilienz, psychologische</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biological models</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biomechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Elite athletes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Movement</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Resilience, psychological</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/6511/Dendorfer_Orthopaedie_2023.pdf</file>
  </doc>
  <doc>
    <id>2013</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>156</pageFirst>
    <pageLast>164</pageLast>
    <pageNumber/>
    <edition/>
    <issue>2</issue>
    <volume>25</volume>
    <type>article</type>
    <publisherName>Taylor &amp; Francis</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-06-28</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">The impact of anatomical uncertainties on the predictions of a musculoskeletal hand model – a sensitivity study</title>
    <abstract language="eng">Outputs of musculoskeletal models should be considered probabilistic rather than deterministic as they are affected by inaccuracies and estimations associated with the development of the model. One of these uncertainties being critical for modeling arises from the determination of the muscles' line of action and the physiological cross-sectional area. Therefore, the aim of this study was to evaluate the outcome sensitivity of model predictions from a musculoskeletal hand model in comparison to the uncertainty of these input parameters. For this purpose, the kinematics and muscle activities of different hand movements (abduction of the fingers, abduction of the thumb, and flexion of the thumb) were recorded. One thousand simulations were calculated for each movement using the Latin hypercube sampling method with a corresponding variation of the muscle origin/insertion points and the cross-sectional area. Comparing the standard hand to simulations incorporating uncertainties of input parameters shows no major deviations in on- and off-set time point of muscle activities. About 60% of simulations are located within a ± 30% interval around the standard model concerning joint reaction forces. The comparison with the variation of the input data leads to the conclusion that the standard hand model is able to provide not over-scattered outcomes and, therefore, can be considered relatively stable. These results are of practical importance to the personalization of a musculoskeletal model with subject-specific bone geometries and hence changed muscle line of action.</abstract>
    <parentTitle language="eng">Computer Methods in Biomechanics and Biomedical Engineering</parentTitle>
    <identifier type="doi">10.1080/10255842.2021.1940974</identifier>
    <identifier type="issn">1476-8259</identifier>
    <note>Corresponding author: Maximilian Melzner</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Creative Commons - CC BY-NC-ND - Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International</licence>
    <author>Maximilian Melzner</author>
    <author>Franz Suess</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Biomechanik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Simulation</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>2069</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>8</pageNumber>
    <edition/>
    <issue>2</issue>
    <volume>144</volume>
    <type>article</type>
    <publisherName>American Society of Mechanical Engineers, ASME</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-09-29</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Electromyography-Based Validation of a Musculoskeletal Hand Model</title>
    <abstract language="eng">Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity.</abstract>
    <parentTitle language="eng">Journal of Biomechanical Engineering</parentTitle>
    <identifier type="doi">10.1115/1.4052115</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Maximilian Melzner</author>
    <author>Lucas Engelhardt</author>
    <author>Ulrich Simon</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Elektromyographie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Biomechanik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Simulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electromyography</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Muscle</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Musculoskeletal system</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Signals</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Simulation</value>
    </subject>
    <collection role="ddc" number="610">Medizin und Gesundheit</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>2188</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>177</pageFirst>
    <pageLast>186</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>30</volume>
    <type>article</type>
    <publisherName>IOS Press</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-12-01</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing</title>
    <abstract language="deu">BACKGROUND:&#13;
Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements.&#13;
&#13;
OBJECTIVE:&#13;
For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture.&#13;
&#13;
METHODS:&#13;
Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position.&#13;
&#13;
RESULTS:&#13;
The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture.&#13;
&#13;
CONCLUSIONS:&#13;
Elevating the right shoulder while playing the violin may pose a potential problem.</abstract>
    <parentTitle language="eng">Technology and Health Care</parentTitle>
    <identifier type="doi">10.3233/THC-219001</identifier>
    <note>Corresponding author: Anne-Sophie Saffert</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Creative Commons - CC BY-NC - Namensnennung - Nicht kommerziell 4.0 International</licence>
    <author>Anne-Sophie Saffert</author>
    <author>Maximilian Melzner</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Biomechanische Analyse</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Schultergelenk</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Verletzung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Violinspiel</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>biomechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>violin</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>shoulder elevation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>shoulder joint force</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>musculoskeletal disease</value>
    </subject>
    <collection role="ddc" number="610">Medizin und Gesundheit</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>7323</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>10</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>IOS Press</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics</title>
    <abstract language="eng">BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research. &#13;
&#13;
METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems. &#13;
&#13;
RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements. &#13;
&#13;
CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models.</abstract>
    <parentTitle language="eng">Technology and Health Care</parentTitle>
    <identifier type="issn">0928-7329</identifier>
    <identifier type="doi">10.3233/THC-240202</identifier>
    <note>Corresponding author der OTH Regensburg: Sebastian Dendorfer</note>
    <enrichment key="CorrespondingAuthor">Sebastian Dendorfer</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY-NC - Namensnennung - Nicht kommerziell 4.0 International</licence>
    <author>Simon Auer</author>
    <author>Franz Süß</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>biomechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>range of motion</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>musculoskeletal system</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>optical motion capture</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>3302</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>192</pageFirst>
    <pageLast>200</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>12</volume>
    <type>article</type>
    <publisherName>Bentham</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Controllable Magnetoactive Polymer Conduit</title>
    <abstract language="eng">Objective: &#13;
Magneto-active Polymers (MAP) are smart materials whose mechanical characteristics, such as elastic and shear moduli, may be controllable by means of an externally applied magnetic field.&#13;
&#13;
Methods: &#13;
Various additives may be used to influence the characteristics of the polymer matrix whilst a suspension of soft and/or hard magnetic particles determine the magnetic properties of the composite. Both pre-cure and post-cure magnetization is possible.&#13;
&#13;
Results:&#13;
A range of control strategies have been investigated for evaluation of the system using fluids of differing kinematic viscosity.&#13;
&#13;
Conclusion: &#13;
Depending on the degree of magnetic field homogeneity, magneto-deformation and magnetostriction contribute to MAP actuation. This paper presents a novel application in the form of a peristaltic MAP tube system, applicable to flow control and pumping of hemorheological fluids in blood circulatory systems for biomedical research purposes.</abstract>
    <parentTitle language="eng">The Open Mechanical Engineering Journal</parentTitle>
    <identifier type="url">https://www.benthamopen.com/ABSTRACT/TOMEJ-12-192</identifier>
    <note>Corresponding authro: Gareth J. Monkman</note>
    <enrichment key="opus.import.date">2022-03-29T06:25:40+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Andreas Diermeier</author>
    <author>Dirk Sindersberger</author>
    <author>Lars Krenkel</author>
    <author>X. C. Rosell</author>
    <author>Gareth J. Monkman</author>
    <collection role="institutes" number="FakEI">Fakultät Elektro- und Informationstechnik</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16312">Energie und Mobilität</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="institutes" number="">Mechatronics Research Unit (MRU)</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>6123</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>21</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>10</volume>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">In Vitro Analysis of Human Cartilage Infiltrated by Hydrogels and Hydrogel-Encapsulated Chondrocytes</title>
    <abstract language="eng">Osteoarthritis (OA) is a degenerative joint disease causing loss of articular cartilage and structural damage in all joint tissues. Given the limited regenerative capacity of articular cartilage, methods to support the native structural properties of articular cartilage are highly anticipated. The aim of this study was to infiltrate zwitterionic monomer solutions into human OA-cartilage explants to replace lost proteoglycans. The study included polymerization and deposition of methacryloyloxyethyl-phosphorylcholine- and a novel sulfobetaine-methacrylate-based monomer solution within ex vivo human OA-cartilage explants and the encapsulation of isolated chondrocytes within hydrogels and the corresponding effects on chondrocyte viability. The results demonstrated that zwitterionic cartilage–hydrogel networks are formed by infiltration. In general, cytotoxic effects of the monomer solutions were observed, as was a time-dependent infiltration behavior into the tissue accompanied by increasing cell death and penetration depth. The successful deposition of zwitterionic hydrogels within OA cartilage identifies the infiltration method as a potential future therapeutic option for the repair/replacement of OA-cartilage extracellular suprastructure. Due to the toxic effects of the monomer solutions, the focus should be on sealing the OA-cartilage surface, instead of complete infiltration. An alternative treatment option for focal cartilage defects could be the usage of monomer solutions, especially the novel generated sulfobetaine-methacrylate-based monomer solution, as bionic for cell-based 3D bioprintable hydrogels.</abstract>
    <parentTitle language="eng">Bioengineering</parentTitle>
    <identifier type="doi">10.3390/bioengineering10070767</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-61235</identifier>
    <note>Corresponding author: Helga Hornberger</note>
    <enrichment key="opus.import.data">@articlearticle, author = Köck, Hannah and Striegl, Birgit and Kraus, Annalena and Zborilova, Magdalena and Christiansen, Silke and Schäfer, Nicole and Grässel, Susanne and Hornberger, H., year = 2023, month = 06, pages = 767, title = In Vitro Analysis of Human Cartilage Infiltrated by Hydrogels and Hydrogel-Encapsulated Chondrocytes, volume = 10, journal = Bioengineering, doi = 10.3390/bioengineering10070767</enrichment>
    <enrichment key="opus.import.dataHash">md5:259fefd1488ba80f897befdbf68256b4</enrichment>
    <enrichment key="opus.import.date">2023-06-30T15:13:21+00:00</enrichment>
    <enrichment key="opus.import.file">/tmp/phpviUmRr</enrichment>
    <enrichment key="opus.import.format">bibtex</enrichment>
    <enrichment key="opus.import.id">649ef1117e8476.40764068</enrichment>
    <enrichment key="CorrespondingAuthor">Helga Hornberger</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Hannah Köck</author>
    <author>Birgit Striegl</author>
    <author>Annalena Kraus</author>
    <author>Magdalena Zborilova</author>
    <author>Silke H. Christiansen</author>
    <author>Nicole Schäfer</author>
    <author>Susanne Grässel</author>
    <author>Helga Hornberger</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>osteoarthritis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>human articular cartilage</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>chondrocytes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>hydrogels</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>zwitterionic monomers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>infiltration</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="hornbergerbma">Hornberger, Helga (Prof. Dr.) - Labor Biomaterialien</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomaterialien</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/6123/Hornberger_bioengineering-10-00767.pdf</file>
  </doc>
  <doc>
    <id>2449</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>8</pageFirst>
    <pageLast>19</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>73</volume>
    <type>article</type>
    <publisherName>Wiley</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Bioactivity and corrosion behavior of magnesium barrier membranes</title>
    <abstract language="eng">In the current research, magnesium and its alloys have been intensively studied as resorbable implant materials. Magnesium materials combine their good mechanical properties with bioactivity, which make them interesting for guided bone regeneration and for the application as barrier membranes. In this study, the in vitro degradation behavior of thin magnesium films was investigated in cell medium and simulated body fluid. Three methods were applied to evaluate corrosion rates: measurements of (i) the gaseous volume evolved during immersion, (ii) volume change after immersion, and (iii) polarization curves. In this comparison, measurements of H2 development in Dulbecco's modified Eagle's medium showed to be the most appropriate method, exhibiting a corrosion rate of 0.5 mm·year−1. Observed oxide and carbon contamination have a high impact on controlled degradation, suggesting that surface treatment of thin foils is necessary. The bioactivity test showed positive results; more detailed tests in this area are of interest.</abstract>
    <parentTitle language="deu">Materials and Corrosion</parentTitle>
    <identifier type="doi">10.1002/maco.202112385</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-24499</identifier>
    <note>Corresponding author: Helga Hornberger</note>
    <enrichment key="opus.import.date">2022-01-21T08:21:02+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Helga Hornberger</enrichment>
    <licence>Creative Commons - CC BY-NC-SA - Namensnennung - Nicht kommerziell -  Weitergabe unter gleichen Bedingungen 4.0 International</licence>
    <author>Helga Hornberger</author>
    <author>Hannah Kissel</author>
    <author>Birgit Striegl</author>
    <author>Matthias Kronseder</author>
    <author>Florian Vollnhals</author>
    <author>Silke H. Christiansen</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="persons" number="hornbergerbma">Hornberger, Helga (Prof. Dr.) - Labor Biomaterialien</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">DEAL Wiley</collection>
    <collection role="institutes" number="">Labor Biomaterialien</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/2449/Hornberger_Materials_Corrosion_2021.pdf</file>
  </doc>
  <doc>
    <id>2457</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>283</pageFirst>
    <pageLast>289</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>30</volume>
    <type>article</type>
    <publisherName>IOS Press</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">2D numerical investigations derived from a 3D dragonfly wing captured with a high-resolution micro-CT</title>
    <abstract language="eng">BACKGROUND: &#13;
Due to their corrugated profile, dragonfly wings have special aerodynamic characteristics during flying and gliding. OBJECTIVE: The aim of this study was to create a realistic 3D model of a dragonfly wing captured with a high-resolution micro-CT. To represent geometry changes in span and chord length and their aerodynamic effects, numerical investigations are carried out at different wing positions. METHODS: &#13;
The forewing of a Camacinia gigantea was captured using a micro-CT. After the wing was adapted an error-free 3D model resulted. The wing was cut every 5 mm and 2D numerical analyses were conducted in Fluent® 2020 R2 (ANSYS, Inc., Canonsburg, PA, USA). RESULTS: The highest lift coefficient, as well as the highest lift-to-drag ratio, resulted at 0 mm and an angle of attack (AOA) of 5∘. At AOAs of 10∘ or 15∘, the flow around the wing stalled and a Kármán vortex street behind the wing becomes&#13;
CONCLUSIONS:&#13;
The velocity is higher on the upper side of the wing compared to the lower side. The pressure acts vice versa. Due to the recirculation zones that are formed in valleys of the corrugation pattern the wing resembles the form of an airfoil.</abstract>
    <parentTitle language="eng">Technology and health care : official journal of the European Society for Engineering and Medicine</parentTitle>
    <identifier type="doi">10.3233/THC-219010</identifier>
    <note>Corresponding author: Vera Stelzer</note>
    <enrichment key="opus.import.date">2022-01-21T08:21:02+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="ConferenceStatement">Selected Papers From the 13th International Conference BIOMDLORE 2021</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY-NC - Namensnennung - Nicht kommerziell 4.0 International</licence>
    <author>Vera Stelzer</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>aerodynamics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>computational fluid dynamics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Dragonfly wing</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>gliding flight</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>insect flight</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>6482</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>12</pageNumber>
    <edition/>
    <issue>1</issue>
    <volume>18</volume>
    <type>article</type>
    <publisherName>PAGEPress</publisherName>
    <publisherPlace>Pavia, Italy</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Experimental studies and mathematical modeling of the viscoelastic rheology of tracheobronchial mucus from respiratory healthy patients</title>
    <abstract language="deu">BACKGROUND: &#13;
Tracheobronchial mucus plays a crucial role in pulmonary function by providing protection against inhaled pathogens. Due to its composition of water, mucins, and other biomolecules, it has a complex viscoelastic rheological behavior. This interplay of both viscous and elastic properties has not been fully described yet. In this study, we characterize the rheology of human mucus using oscillatory and transient tests. Based on the transient tests, we describe the material behavior of mucus under stress and strain loading by mathematical models. &#13;
METHODS: &#13;
Mucus samples were collected from clinically used endotracheal tubes. For rheological characterization, oscillatory amplitude-sweep and frequency-sweep tests, and transient creep-recovery and stress-relaxation tests were performed. The results of the transient test were approximated using the Burgers model, the Weibull distribution, and the six-element Maxwell model. The three-dimensional microstructure of the tracheobronchial mucus was visualized using scanning electron microscope imaging.&#13;
RESULTS: &#13;
Amplitude-sweep tests showed storage moduli ranging from 0.1 Pa to 10000 Pa and a median critical strain of 4 %. In frequency-sweep tests, storage and loss moduli increased with frequency, with the median of the storage modulus ranging from 10 Pa to 30 Pa, and the median of the loss modulus from 5 Pa to 14 Pa. The Burgers model approximates the viscoelastic behavior of tracheobronchial mucus during a constant load of stress appropriately (R2 of 0.99), and the Weibull distribution is suitable to predict the recovery of the sample after the removal of this stress (R2 of 0.99). The approximation of the stress-relaxation test data by a six-element Maxwell model shows a larger fit error (R2 of 0.91).&#13;
CONCLUSIONS: &#13;
This study provides a detailed description of all process steps of characterizing the rheology of tracheobronchial mucus, including sample collection, microstructure visualization, and rheological investigation. Based on this characterization, we provide mathematical models of the rheological behavior of tracheobronchial mucus. These can now be used to simulate mucus flow in the respiratory system through numerical approaches.</abstract>
    <parentTitle language="deu">Multidisciplinary Respiratory Medicine</parentTitle>
    <identifier type="doi">10.4081/mrm.2023.923</identifier>
    <identifier type="issn">2049-6958</identifier>
    <identifier type="pmid">37908973</identifier>
    <note>Corresponding author: Sandra Melina Tauwald</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Sandra Melina Tauwald</enrichment>
    <licence>Creative Commons - CC BY-ND - Namensnennung - Keine Bearbeitungen 4.0 International</licence>
    <author>Sandra Melina Tauwald</author>
    <author>Johanna Michel</author>
    <author>Marie Brandt</author>
    <author>Veronika Vielsmeier</author>
    <author>Christian Stemmer</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>tracheobronchial mucus</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>rheological model</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>viscoelasticity</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>7929</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>513</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">High quality surfaces of magnesium alloy AZ31 by adjusting appropriate electropolishing parameters</title>
    <parentTitle language="eng">Electrochimica Acta</parentTitle>
    <identifier type="doi">10.1016/j.electacta.2024.145547</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-79298</identifier>
    <note>Corresponding author der OTH Regensburg: Jessica Kloiber</note>
    <enrichment key="opus.import.date">2025-01-20T09:16:32+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Jessica Kloiber</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Jessica Kloiber</author>
    <author>Viktoria Anetsberger</author>
    <author>Ulrich Schultheiß</author>
    <author>Helga Hornberger</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="persons" number="hornbergerbma">Hornberger, Helga (Prof. Dr.) - Labor Biomaterialien</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomaterialien</collection>
    <collection role="funding" number="">DEAL Elsevier</collection>
    <collection role="DFGFachsystematik" number="1">Ingenieurwissenschaften</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/7929/Kloiber_Elsevier_2025.pdf</file>
  </doc>
  <doc>
    <id>8351</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>5</pageNumber>
    <edition/>
    <issue/>
    <volume>397</volume>
    <type>article</type>
    <publisherName>Elsevier BV</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Impact of heat treatment on the surface quality of electropolished WE43 alloy</title>
    <abstract language="eng">In this study, the Mg alloy WE43 was solution annealed and precipitation hardened prior to electropolishing to evaluate the effects of different microstructures on the electropolishing result. While coarsely distributed precipitates led to surfaces showing wavy structures and dents after electropolishing, a uniform microstructure resulted in an even finish of the surface. The homogenization and refinement of the microstructure by heat treatment is a method to ensure improved electropolished surfaces of Mg materials</abstract>
    <parentTitle language="eng">Materials Letters</parentTitle>
    <identifier type="issn">0167-577X</identifier>
    <identifier type="doi">10.1016/j.matlet.2025.138821</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-83512</identifier>
    <note>Corresponding author der OTH Regensburg: Jessica Kloiber</note>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="CorrespondingAuthor">Jessica Kloiber</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Jessica Kloiber</author>
    <author>Ulrich Schultheiß</author>
    <author>Helga Hornberger</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="persons" number="hornbergerbma">Hornberger, Helga (Prof. Dr.) - Labor Biomaterialien</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomaterialien</collection>
    <collection role="funding" number="">DEAL Elsevier</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/8351/Kloiber_materials_letters_2025.pdf</file>
  </doc>
  <doc>
    <id>2161</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>30</pageLast>
    <pageNumber/>
    <edition/>
    <issue>12</issue>
    <volume>15</volume>
    <type>article</type>
    <publisherName>PLOS</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Computational analysis of the effects of geometric irregularities and post-processing steps on the mechanical behavior of additively manufactured 316L stainless steel stents</title>
    <abstract language="eng">Advances in additive manufacturing enable the production of tailored lattice structures and thus, in principle, coronary stents. This study investigates the effects of process-related irregularities, heat and surface treatment on the morphology, mechanical response, and expansion behavior of 316L stainless steel stents produced by laser powder bed fusion and provides a methodological approach for their numerical evaluation. A combined experimental and computational framework is used, based on both actual and computationally reconstructed laser powder bed fused stents. Process-related morphological deviations between the as-designed and actual laser powder bed fused stents were observed, resulting in a diameter increase by a factor of 2-2.6 for the stents without surface treatment and 1.3-2 for the electropolished stent compared to the as-designed stent. Thus, due to the increased geometrically induced stiffness, the laser powder bed fused stents in the as-built (7.11 ± 0.63 N) or the heat treated condition (5.87 ± 0.49 N) showed increased radial forces when compressed between two plates. After electropolishing, the heat treated stents exhibited radial forces (2.38 ± 0.23 N) comparable to conventional metallic stents. The laser powder bed fused stents were further affected by the size effect, resulting in a reduced yield strength by 41% in the as-built and by 59% in the heat treated condition compared to the bulk material obtained from tensile tests. The presented numerical approach was successful in predicting the macroscopic mechanical response of the stents under compression. During deformation, increased stiffness and local stress concentration were observed within the laser powder bed fused stents. Subsequent numerical expansion analysis of the derived stent models within a previously verified numerical model of stent expansion showed that electropolished and heat treated laser powder bed fused stents can exhibit comparable expansion behavior to conventional stents. The findings from this work motivate future experimental/numerical studies to quantify threshold values of critical geometric irregularities, which could be used to establish design guidelines for laser powder bed fused stents/lattice structures.</abstract>
    <parentTitle language="eng">PLoS ONE</parentTitle>
    <identifier type="doi">10.1371/journal.pone.0244463</identifier>
    <note>Corresponding author: Lisa Wiesent</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Lisa Wiesent</author>
    <author>Ulrich Schultheiß</author>
    <author>Philipp Lulla</author>
    <author>Ulf Noster</author>
    <author>Thomas Schratzenstaller</author>
    <author>Christof Schmid</author>
    <author>Aida Nonn</author>
    <author>Ashley Spear</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Heat treatment</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lasers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Surface treatments</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Specimen preparation and treatment</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Material properties</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Stiffness</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Deformation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Powders</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Koronarendoprothese</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Rapid prototyping</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Numerische Methode</value>
    </subject>
    <collection role="ddc" number="610">Medizin und Gesundheit</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="schratzenstallermd">Schratzenstaller, Thomas (Prof. Dr.) -Labor Medizinprodukte</collection>
    <collection role="institutes" number="TCNeustadt">Technologie-Campus Neustadt an der Donau</collection>
    <collection role="persons" number="nonncmm">Nonn, Aida (Prof. Dr.) - Computational Mechanics and Materials Lab</collection>
    <collection role="persons" number="tcnehno">Technologie-Campus Neustadt a. d. Donau (Prof. Ehrlich+ Prof. Nonn)</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="TCParsberg">Technologie-Campus Parsberg-Lupburg</collection>
    <collection role="institutes" number="">Labor Medizinprodukte</collection>
    <collection role="institutes" number="">Computational Mechanics and Materials Lab (CMM)</collection>
    <collection role="institutes" number="">Labor Werkstoffrandschichtanalytik</collection>
  </doc>
  <doc>
    <id>7039</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>5</issue>
    <volume>35</volume>
    <type>article</type>
    <publisherName>IOP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Tomo-PIV in a patient-specific model of human nasal cavities: a methodological approach</title>
    <abstract language="eng">The human nose serves as the primary gateway for air entering the respiratory system and plays a vital role in breathing. Nasal breathing difficulties are a significant health concern, leading to substantial healthcare costs for patients. Understanding nasal airflow dynamics is crucial for comprehending respiratory mechanisms. This article presents a detailed study using tomo-Particle Image Velocimetry (PIV) to investigate nasal airflow dynamics while addressing its accuracy. Embedded in the OpenNose project, the work described aims to provide a validation basis for different numerical approaches to upper airway flow. The study includes the manufacturing of a transparent silicone model based on a clinical CT scan, refractive index matching to minimize optical distortions, and precise flow rate adjustments based on physiological breathing cycles. This method allows for spatial high-resolution investigations in different regions of interest within the nasopharynx during various phases of the breathing cycle. The results demonstrate the accuracy of the investigations, enabling detailed analysis of flow structures and gradients. This spatial high-resolution tomo-PIV approach provides valuable insights into the complex flow phenomena occurring during the physiological breathing cycle in the nasopharynx. The study's findings contribute to advancements in non-free-of-sight experimental flow investigation of complex cavities under nearly realistic conditions. Furthermore, reliable and accurate experimental data is crucial for properly validating numerical approaches that compute this patient-specific flow for clinical purposes.</abstract>
    <parentTitle language="eng">Measurement Science and Technology</parentTitle>
    <identifier type="doi">10.1088/1361-6501/ad282c</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-70393</identifier>
    <note>Corresponding author: Sandra Melina Tauwald</note>
    <enrichment key="ConferenceStatement">The 20th International Symposium on Flow Visualization (ISFV20), Delft, the Netherlands, on 10-13 July 2023</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Sandra Melina Tauwald</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Sandra Melina Tauwald</author>
    <author>Florian Erzinger</author>
    <author>Maurizio Quadrio</author>
    <author>Markus Rütten</author>
    <author>Christian Stemmer</author>
    <author>Lars Krenkel</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/7039/Tauwald_IOP_2024.pdf</file>
  </doc>
  <doc>
    <id>2211</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>1208</volume>
    <type>conferenceobject</type>
    <publisherName>IOP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-12-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Towards ergonomics working - machine learning algorithms and musculoskeletal modeling</title>
    <abstract language="eng">Ergonomic workplaces lead to fewer work-related musculoskeletal disorders and thus fewer sick days. There are various guidelines to help avoid harmful situations. However, these recommendations are often rather crude and often neglect the complex interaction of biomechanical loading and psychological stress. This study investigates whether machine learning algorithms can be used to predict mechanical and stress-related muscle activity for a standardized motion. For this purpose, experimental data were collected for trunk movement with and without additional psychological stress. Two different algorithms (XGBoost and TensorFlow) were used to model the experimental data. XGBoost in particular predicted the results very well. By combining it with musculoskeletal models, the method shown here can be used for workplace analysis but also for the development of real-time feedback systems in real workplace environments.</abstract>
    <parentTitle language="eng">IOP Conference Series: Materials Science and Engineering</parentTitle>
    <identifier type="doi">10.1088/1757-899X/1208/1/012001</identifier>
    <identifier type="issn">1757-899X</identifier>
    <note>Corresponding author: Sebastian Dendorfer</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="ConferenceStatement">13th International Conference on Development and Modernization of the Manufacturing (RIM 2021), 29th September - 1st October 2021, Sarajevo, Bosnia and Herzegovina</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Franz Suess</author>
    <author>Maximilian Melzner</author>
    <author>Sebastian Dendorfer</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="dendorferlbmconf">Dendorfer, Sebastian (Prof. Dr.), Konferenzbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
</export-example>