<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>5221</id>
    <completedYear/>
    <publishedYear>2013</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>241</pageFirst>
    <pageLast>249</pageLast>
    <pageNumber/>
    <edition/>
    <issue>2</issue>
    <volume>106</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Stochastic triangulation for prostate positioning during radiotherapy using short CBCT arcs</title>
    <abstract language="eng">Background and purpose: &#13;
Fast and reliable tumor localization is an important part of today's radiotherapy utilizing new delivery techniques. This proof-of-principle study demonstrates the use of a method called herein 'stochastic triangulation' for this purpose. Stochastic triangulation uses very short imaging arcs and a few projections.&#13;
Materials and methods: &#13;
A stochastic Maximum A Posteriori (MAP) estimator is proposed based on an uncertainty-driven model of the acquisition geometry and inter-/intra-fractional deformable anatomy. The application of this method was designed to use the available linac-mounted cone-beam computed tomography (CBCT) and/or electronic portal imaging devices (EPID) for the patient setup based on short imaging arcs. For the proof-of-principle clinical demonstration, the MAP estimator was applied to 5 CBCT scans of a prostate cancer patient with 2 implanted gold markers. Estimation was performed for several (18) very short imaging arcs of 5° with 10 projections resulting in 90 estimations.&#13;
Results: &#13;
Short-arc stochastic triangulation led to residual radial errors compared to manual inspection with a mean value of 1.4mm and a standard deviation of 0.9 mm (median 1.2mm, maximum 3.8mm) averaged over imaging directions all around the patient. Furthermore, abrupt intra-fractional motion of up to 10mm resulted in radial errors with a mean value of 1.8mm and a standard deviation of 1.1mm (median 1.5mm, maximum 5.6mm). Slow periodic intra-fractional motions in the range of 12 mm resulted in radial errors with a mean value of 1.8mm and a standard deviation of 1.1mm (median 1.6mm, maximum 4.7 mm).&#13;
Conclusion: &#13;
Based on this study, the proposed stochastic method is fast, robust and can be used for inter- as well as intra-fractional target localization using current CBCT units.</abstract>
    <parentTitle language="eng">Radiotherapy and Oncology</parentTitle>
    <identifier type="doi">10.1016/j.radonc.2013.01.005</identifier>
    <enrichment key="opus.import.date">2022-08-20T07:06:56+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Wolfgang Högele</author>
    <author>Barbara Dobler</author>
    <author>Oliver Kölbl</author>
    <author>Clair Beard</author>
    <author>Piotr Zygmanski</author>
    <author>Rainer Löschel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Patient positioning</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Setup error</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Maximum A Posteriori estimation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Short arc</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Stochastic triangulation</value>
    </subject>
    <collection role="institutes" number="FakIM">Fakultät Informatik und Mathematik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
  </doc>