<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>293</id>
    <completedYear/>
    <publishedYear>2019</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>8</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>9</volume>
    <type>article</type>
    <publisherName>Nature</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-12</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">A simple method for determining ligament stiffness during total knee arthroplasty in vivo</title>
    <abstract language="eng">A key requirement in both native knee joints and total knee arthroplasty is a stable capsular ligament complex. However, knee stability is highly individual and ranges from clinically loose to tight. So far, hardly any in vivo data on the intrinsic mechanical of the knee are available. This study investigated if stiffness of the native ligament complex may be determined in vivo using a standard knee balancer. Measurements were obtained with a commercially available knee balancer, which was initially calibrated in vitro. 5 patients underwent reconstruction of the force-displacement curves of the ligament complex. Stiffness of the medial and lateral compartments were calculated to measure the stability of the capsular ligament complex. All force-displacement curves consisted of a non-linear section at the beginning and of a linear section from about 80 N onwards. The medial compartment showed values of 28.4 ± 1.2 N/mm for minimum stiffness and of 39.9 ± 1.1 N/mm for maximum stiffness; the respective values for the lateral compartment were 19.9 ± 0.9 N/mm and 46.6 ± 0.8 N/mm. A commercially available knee balancer may be calibrated for measuring stiffness of knee ligament complex in vivo, which may contribute to a better understanding of the intrinsic mechanical behaviour of knee joints.</abstract>
    <parentTitle language="eng">Scientific Reports</parentTitle>
    <identifier type="doi">10.1038/s41598-019-41732-x</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Florian Völlner</author>
    <author>Tim A. Weber</author>
    <author>Markus Weber</author>
    <author>Tobias Renkawitz</author>
    <author>Sebastian Dendorfer</author>
    <author>Joachim Grifka</author>
    <author>Benjamin Craiovan</author>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Biomechanische Analyse</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Kniegelenkband</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Steifigkeit</value>
    </subject>
    <collection role="ddc" number="617">Chirurgie und verwandte medizinische Fachrichtungen</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>302</id>
    <completedYear/>
    <publishedYear>2016</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>196</pageFirst>
    <pageLast>201</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>vol. 49</volume>
    <type>article</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics</title>
    <abstract language="eng">We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p &lt; 0.001), normalized walking speed (p &lt; 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register.</abstract>
    <parentTitle language="eng">Gait &amp; Posture</parentTitle>
    <identifier type="doi">10.1016/j.gaitpost.2016.07.011</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <author>Tobias Renkawitz</author>
    <author>Tim A. Weber</author>
    <author>Silvia Dullien</author>
    <author>Michael Woerner</author>
    <author>Sebastian Dendorfer</author>
    <author>Joachim Grifka</author>
    <author>Markus Weber</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>THA</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Leg length</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Offset</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Gait analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biomechanics</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>304</id>
    <completedYear/>
    <publishedYear>2016</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1628</pageFirst>
    <pageLast>1635</pageLast>
    <pageNumber/>
    <edition/>
    <issue>9</issue>
    <volume>34</volume>
    <type>article</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">The influence of rotator cuff tears on glenohumeral stability during abduction tasks</title>
    <abstract language="eng">One of the main goals in reconstructing rotator cuff tears is the restoration of glenohumeral joint stability, which is subsequently of utmost importance in order to prevent degenerative damage such as superior labral anterior posterior (SLAP) lesion, arthrosis, and malfunction. The goal of the current study was to facilitate musculoskeletal models in order to estimate glenohumeral instability introduced by muscle weakness due to cuff lesions. Inverse dynamics simulations were used to compute joint reaction forces for several static abduction tasks with different muscle weakness. Results were compared with the existing literature in order to ensure the model validity. Further arm positions taken from activities of daily living, requiring the rotator cuff muscles were modeled and their contribution to joint kinetics computed. Weakness of the superior rotator cuff muscles (supraspinatus; infraspinatus) leads to a deviation of the joint reaction force to the cranial dorsal rim of the glenoid. Massive rotator cuff defects showed higher potential for glenohumeral instability in contrast to single muscle ruptures. The teres minor muscle seems to substitute lost joint torque during several simulated muscle tears to maintain joint stability. Joint instability increases with cuff tear size. Weakness of the upper part of the rotator cuff leads to a joint reaction force closer to the upper glenoid rim. This indicates the comorbidity of cuff tears with SLAP lesions. The teres minor is crucial for maintaining joint stability in case of massive cuff defects and should be uprated in clinical decision-making.</abstract>
    <parentTitle language="eng">Journal of Orthopaedic Research</parentTitle>
    <identifier type="doi">10.1002/jor.23161</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <author>Thomas Hölscher</author>
    <author>Tim A. Weber</author>
    <author>Igor A. Lazarev</author>
    <author>Carsten Englert</author>
    <author>Sebastian Dendorfer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Abduction tasks</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Glenohumeral stability</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Musculoskeletal Modeling</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Muscle weakness</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Rotator cuff tears</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Rotatorenmanschettenriss</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Schultergelenk</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Stabilität</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>301</id>
    <completedYear/>
    <publishedYear>2016</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>418</pageFirst>
    <pageLast>425</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>vol. 49</volume>
    <type>article</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Gait six month and one-year after computer assisted Femur First THR vs. conventional THR. Results of a patient- and observer- blinded randomized controlled trial</title>
    <abstract language="eng">A prospective randomized controlled trial is presented that is used to compare gait performance between the computer assisted Femur First (CAS FF) operation method and conventional THR (CON). 60 patients underwent a 3D gait analysis of the lower extremity at pre-operative, 6 months post-operative and twelve months post-operative. Detailed verification experiments were facilitated to ensure the quality of data as well as to avoid over-interpreting of the data. The results confirm a similar data-quality as reported in the literature. Walking speed, range of motion and symmetry thereof improved over the follow-up period, without significant differences between the groups. While all parameters do significantly increase over the follow-up period for both groups, there were no significant differences between them at any given time-point. Patients undergoing CAS FF showed a trend to improved hip flexion angle indicating a possible long-term benefit.</abstract>
    <parentTitle language="eng">Gait &amp; Posture</parentTitle>
    <identifier type="doi">10.1016/j.gaitpost.2016.06.035</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <author>Tim A. Weber</author>
    <author>Sebastian Dendorfer</author>
    <author>Sjoerd K. Bulstra</author>
    <author>Joachim Grifka</author>
    <author>Gijsbertus Jacob Verkerke</author>
    <author>Tobias Renkawitz</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Biomechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Combined anteversion</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Computer-assisted surgery</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Femur first</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Gait analysis</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>308</id>
    <completedYear/>
    <publishedYear>2015</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>ID 625317</pageFirst>
    <pageLast/>
    <pageNumber>16 Seiten</pageNumber>
    <edition/>
    <issue/>
    <volume>2015</volume>
    <type>article</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-18</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions?</title>
    <abstract language="eng">We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of “femur first/combined anteversion,” which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient’s gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome.</abstract>
    <parentTitle language="eng">BioMed Research International</parentTitle>
    <identifier type="doi">10.1155/2015/625317</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <author>Tim A. Weber</author>
    <author>Sebastian Dendorfer</author>
    <author>Joachim Grifka</author>
    <author>Gijsbertus Jacob Verkerke</author>
    <author>Tobias Renkawitz</author>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Hüftgelenkprothese</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Operationstechnik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Computerunterstütztes Verfahren</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Bewegungsapparat</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Mechanische Belastung</value>
    </subject>
    <collection role="ddc" number="000">Informatik, Informationswissenschaft, allgemeine Werke</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>315</id>
    <completedYear/>
    <publishedYear>2012</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>939</pageFirst>
    <pageLast>946</pageLast>
    <pageNumber/>
    <edition/>
    <issue>12</issue>
    <volume>226</volume>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-02-18</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Measuring functional outcome after total hip replacement with subject-specific hip joint loading</title>
    <abstract language="eng">Total hip replacement is an often-performed orthopedic surgical procedure; the amount of procedures undertaken will increase since our life expectancy is growing. In order to optimize function, hip biomechanics should be restored to as near normal as possible. The goal of this pilot study was to determine whether or not it is feasible to compute the vectorial hip reaction force pathways on the head of the prosthesis and the force angles relative to the cup of the prosthesis that occur during gait in total hip replacement patients, serving as an objective measurement of the functional outcome following hip replacement. A three-dimensional gait analysis, measuring ground reaction forces and kinematics, was performed. The data retrieved from the gait analysis was used as the input for the musculoskeletal model to compute vectorial joint reaction forces for data processing. To evaluate the position and orientation of the joint reaction forces, the force path, as well as the force angles for the operated and non-operated joint, has been calculated during the stance phase of the specific leg. The force path for subject 2 on the non-operated side is only located in the posterior-lateral quarter, as is the force path for subject 1. In contrast to this subject, the force path for subject 2 at the operated hip joint can be found only within the anterior quarter of the head of the implant, where it is nearly equally distributed in the medio-lateral half of the prosthesis head. The force-inclination angles on the cup of subject 1, with respect to the plane of the socket face, indicates that the force vector is mainly positioned in the same quadrant when compared with subject 2 (in a cup-fixed coordinate system). The force-anteversion angle behaves similarly to the force-inclination angle, even when the effects are not as pronounced. The proposed methods in this article are aiming to define two functional outcomes of total hip replacement that are related to wear and rim loading. It is accepted that wear is not only a function of time, but a function of use. Owing to the methods listed in this article, we are able to determine a) the applied force and b) the sliding distance (force pathway) in a subject-specific manner. The computed hip-reaction force angles and the distance to the rim cup are a measurement for cup or rim loading, and occurs in the so-called safe-zones. This method may well give us insight into the biomechanical situation during gait, after receiving total hip replacement, that we need to fully understand the mechanisms acting on a hip joint and to prove a possible increase of functional outcome after receiving total hip replacement.</abstract>
    <parentTitle language="eng">Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine</parentTitle>
    <identifier type="doi">10.1177/0954411912447728</identifier>
    <author>Tim A. Weber</author>
    <author>Sebastian Dendorfer</author>
    <author>Silvia Dullien</author>
    <author>Joachim Grifka</author>
    <author>Gijsbertus Jacob Verkerke</author>
    <author>Tobias Renkawitz</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>total hip replacement</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>subject-specific musculoskeletal modeling</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>functional outcome</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>force pathways</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>force angles</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>critical hip joint loading</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>rim loading</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>cup loading</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Hüftgelenkprothese</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Biomechanik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Lastverteilung &lt;Statik&gt;</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Ganganalyse</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>swd</type>
      <value>Simulation</value>
    </subject>
    <collection role="ddc" number="617">Chirurgie und verwandte medizinische Fachrichtungen</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="persons" number="dendorferlbm">Dendorfer, Sebastian (Prof. Dr.), Zeitschriftenbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>739</id>
    <completedYear/>
    <publishedYear>2015</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Positionsanalyse von winkelstabilen Plattenosteosynthesesystemen zur Versorgung von Metatarsalfrakturen mit Hilfe von patientenspezifischen biomechanischen Modellen</title>
    <parentTitle language="deu">Vereinigung Süddeutscher Orthopäden und Unfallchirurgen Jahrestagung 2015, Baden-Baden, Germany</parentTitle>
    <author>A. Billing</author>
    <author>J. Götz</author>
    <author>Tim Weber</author>
    <author>Sebastian Dendorfer</author>
    <collection role="ddc" number="610">Medizin und Gesundheit</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="dendorferlbmconf">Dendorfer, Sebastian (Prof. Dr.), Konferenzbeiträge - Labor Biomechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biomechanik (LBM)</collection>
  </doc>
  <doc>
    <id>799</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>80</pageNumber>
    <edition/>
    <issue/>
    <volume/>
    <type>periodicalpart</type>
    <publisherName/>
    <publisherPlace>Regensburg</publisherPlace>
    <creatingCorporation>Ostbayerische Technische Hochschule Regensburg</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Forschungsbericht 2013</title>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-7990</identifier>
    <identifier type="doi">10.35096/othr/pub-799</identifier>
    <author>Josef Beimler</author>
    <author>Caroline Leißl</author>
    <author>Lena Ebner</author>
    <author>Michael Elsner</author>
    <author>Gerhard Mühlbauer</author>
    <author>Dieter Kohlert</author>
    <author>Martin J. W. Schubert</author>
    <author>Andreas P. Weiß</author>
    <author>Michael Sterner</author>
    <author>Thomas Raith</author>
    <author>Martin Afranseder</author>
    <author>Tobias Krapf</author>
    <author>Jürgen Mottok</author>
    <author>Christian Siemers</author>
    <author>Benjamin Großmann</author>
    <author>Johannes Höcherl</author>
    <author>Thomas Schlegl</author>
    <author>Ralph Schneider</author>
    <author>Johannes Milaev</author>
    <author>Christina Rampelt</author>
    <author>Christian Roduner</author>
    <author>Christoph Glowa</author>
    <author>Christoph Bachl</author>
    <author>Claus Schliekmann</author>
    <author>Alfons Gnan</author>
    <author>Martin Grill</author>
    <author>Karl Ruhland</author>
    <author>Thomas Piehler</author>
    <author>Daniel Friers</author>
    <author>Harald Wels</author>
    <author>Kenny Pflug</author>
    <author>Markus Kucera</author>
    <author>Thomas Waas</author>
    <author>Felix Schlachetzki</author>
    <author>Sandra Boy</author>
    <author>Josef Pemmerl</author>
    <author>Alexander Leis</author>
    <author>Andreas F.X. Welsch</author>
    <author>Franz Graf</author>
    <author>Gerhard Zenger</author>
    <author>Klaus Volbert</author>
    <author>Thomas Waas</author>
    <author>Stefanie Scherzinger</author>
    <author>Meike Klettke</author>
    <author>Uta Störl</author>
    <author>C. Heyl</author>
    <author>A. Boldenko</author>
    <author>Gareth J. Monkman</author>
    <author>Richard Kujat</author>
    <author>Ulrich Briem</author>
    <author>Stefan Hierl</author>
    <author>Sebastian Talbot</author>
    <author>Anton Schmailzl</author>
    <author>Robert Damian Ławrowski</author>
    <author>Christian Prommesberger</author>
    <author>Christoph Langer</author>
    <author>Florian Dams</author>
    <author>Rupert Schreiner</author>
    <author>Piergiorgio Valentino</author>
    <author>Marco Romano</author>
    <author>Ingo Ehrlich</author>
    <author>Franco Furgiuele</author>
    <author>Norbert Gebbeken</author>
    <author>Michael Eisenried</author>
    <author>Bastian Jungbauer</author>
    <author>Albert Hutterer</author>
    <author>Michael Bauhuber</author>
    <author>Andreas Mikrievskij</author>
    <author>Monika Argauer</author>
    <author>Helmut Hummel</author>
    <author>Alfred Lechner</author>
    <author>Thomas Liebetruth</author>
    <author>Michael Schumm</author>
    <author>Saskia Joseph</author>
    <author>Michael Reschke</author>
    <author>Alexander Soska</author>
    <author>Irmgard Schroll-Decker</author>
    <author>Michael Putzer</author>
    <author>John Rasmussen</author>
    <author>Sebastian Dendorfer</author>
    <author>Tim Weber</author>
    <author>Amir Andreas Al-Munajjed</author>
    <author>Gijsbertus Jacob Verkerke</author>
    <author>Tobias Renkawitz</author>
    <author>Sonja Haug</author>
    <author>Clarissa Rudolph</author>
    <author>Annika Zeitler</author>
    <author>Simon Schaubeck</author>
    <author>Oliver Steffens</author>
    <author>Christian Rechenauer</author>
    <author>Thekla Schulz-Brize</author>
    <author>Florian Fleischmann</author>
    <author>Wolfgang Kusterle</author>
    <author>Anne Beer</author>
    <author>Bernd Wagner</author>
    <author>Thomas Neidhart</author>
    <series>
      <title>Forschungsberichte der OTH Regensburg</title>
      <number>2013</number>
    </series>
    <collection role="institutes" number="HL">Hochschulleitung/Hochschulverwaltung</collection>
    <collection role="othpublikationsherkunft" number="">Von der OTH Regensburg herausgegeben</collection>
    <collection role="institutes" number="IAFW">Zentrum für Forschung und Transfer (ZFT ab 2024; vorher: IAFW)</collection>
    <collection role="persons" number="sternerfenes">Sterner, Michael (Prof. Dr.) - FENES / Forschungsgruppe Energiespeicher</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/799/Forschungsbericht_2013.pdf</file>
  </doc>
  <doc>
    <id>783</id>
    <completedYear/>
    <publishedYear>2012</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>64</pageNumber>
    <edition/>
    <issue/>
    <volume/>
    <type>periodicalpart</type>
    <publisherName/>
    <publisherPlace>Regensburg</publisherPlace>
    <creatingCorporation>Ostbayerische Technische Hochschule Regensburg</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Forschungsbericht 2012</title>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-7834</identifier>
    <identifier type="doi">10.35096/othr/pub-783</identifier>
    <author>Toni Lautenschläger</author>
    <author>Alexander Leis</author>
    <author>Sebastian Dendorfer</author>
    <author>Christoph Palm</author>
    <author>Rupert Schreiner</author>
    <author>Christoph Langer</author>
    <author>Christian Prommesberger</author>
    <author>Robert Damian Ławrowski</author>
    <author>Florian Dams</author>
    <author>Benjamin Bornmann</author>
    <author>Aliaksandr Navitski</author>
    <author>Pavel Serbun</author>
    <author>Günter Müller</author>
    <author>Thomas Liebetruth</author>
    <author>Dieter Kohlert</author>
    <author>Jochen Pernsteiner</author>
    <author>Franz Schreier</author>
    <author>Sabrina Heerklotz</author>
    <author>Allwin Heerklotz</author>
    <author>Alexander Boos</author>
    <author>Dominik Herwald</author>
    <author>Gareth J. Monkman</author>
    <author>Daniel Treiber</author>
    <author>Matthias Mayer</author>
    <author>Eva Hörner</author>
    <author>Alexander Bentz</author>
    <author>Mikhail Shamonin (Chamonine)</author>
    <author>Søren Peter Johansen</author>
    <author>Marco Reichel</author>
    <author>Andrea Stoll</author>
    <author>Ulrich Briem</author>
    <author>Silvia Dullien</author>
    <author>Tobias Renkawitz</author>
    <author>Tim Weber</author>
    <author>Sebastian Dendorfer</author>
    <author>Joachim Grifka</author>
    <author>Rainer Penzkofer</author>
    <author>K. Barnsteiner</author>
    <author>M. Jovanovik</author>
    <author>P. Wernecke</author>
    <author>A. Vögele</author>
    <author>T. Bachmann</author>
    <author>Martin Plötz</author>
    <author>Claus Schliekmann</author>
    <author>Harald Wels</author>
    <author>Paul Helmberger</author>
    <author>Marcel Kaspar</author>
    <author>M. Hönicka</author>
    <author>Siegfried Schrammel</author>
    <author>Markus Enser</author>
    <author>Monika Schmidmeier</author>
    <author>Irmgard Schroll-Decker</author>
    <author>Sonja Haug</author>
    <author>Verena Gelfert</author>
    <author>Matthias Vernim</author>
    <series>
      <title>Forschungsberichte der OTH Regensburg</title>
      <number>2012</number>
    </series>
    <collection role="institutes" number="HL">Hochschulleitung/Hochschulverwaltung</collection>
    <collection role="othpublikationsherkunft" number="">Von der OTH Regensburg herausgegeben</collection>
    <collection role="institutes" number="IAFW">Zentrum für Forschung und Transfer (ZFT ab 2024; vorher: IAFW)</collection>
    <collection role="persons" number="hauglasofo">Haug, Sonja (Prof. Dr.) - Labor Empirische Sozialforschung</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/783/Forschungsbericht_2012.pdf</file>
  </doc>
</export-example>
