<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>3381</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>267</pageFirst>
    <pageLast>272</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Springer Vieweg</publisherName>
    <publisherPlace>Wiesbaden</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2022-04-06</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Classification of Vascular Malformations Based on T2 STIR Magnetic Resonance Imaging</title>
    <abstract language="eng">Vascular malformations (VMs) are a rare condition. They can be categorized into high-ﬂow and low-ﬂow VMs, which is a challenging task for radiologists. In this work, a very heterogeneous set of MRI images with only rough annotations are used for classification with a convolutional neural network. The main focus is to describe the challenging data set and strategies to deal with such data in terms of preprocessing, annotation usage and choice of the network architecture. We achieved a classification result of 89.47 % F1-score with a 3D ResNet 18.</abstract>
    <parentTitle language="eng">Bildverarbeitung für die Medizin 2022: Proceedings, German Workshop on Medical Image Computing, Heidelberg, June 26-28, 2022</parentTitle>
    <identifier type="doi">10.1007/978-3-658-36932-3_57</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Danilo Weber Nunes</author>
    <author>Michael Hammer</author>
    <author>Simone Hammer</author>
    <author>Wibke Uller</author>
    <author>Christoph Palm</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Deep Learning</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Magnetic Resonance Imaging</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Vascular Malformations</value>
    </subject>
    <collection role="ddc" number="0">Informatik, Informationswissenschaft, allgemeine Werke</collection>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FakIM">Fakultät Informatik und Mathematik</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="persons" number="palmremic">Palm, Christoph (Prof. Dr.) - ReMIC</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Regensburg Medical Image Computing (ReMIC)</collection>
  </doc>
</export-example>
