<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>7293</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>5</issue>
    <volume>14</volume>
    <type>article</type>
    <publisherName>AIP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Electrical properties of bisphenol-A-free magnetoactive borosilicate polymers</title>
    <abstract language="eng">The recent REACH regulations require the elimination of bisphenol-A and titanium dioxide from commercially available boron-based polymers. This has led to changes in some of the mechanical characteristics, which strongly influence the properties of magnetoactive borosilicate polymers. This work delivers results on the electrical properties and discusses some implications for future research using bisphenol-A and titanium-dioxide-free substitutes.</abstract>
    <parentTitle language="eng">AIP Advances</parentTitle>
    <identifier type="issn">2158-3226</identifier>
    <identifier type="doi">10.1063/5.0203017</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-72936</identifier>
    <note>Corresponding author der OTH Regensburg: Gareth J. Monkman</note>
    <enrichment key="CorrespondingAuthor">Gareth J. Monkman</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="Kostentraeger">DFG, No. MO 2196/11-1</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Xuyan Loo</author>
    <author>Bhavana Nagaraju</author>
    <author>Sai Pathivada</author>
    <author>Alexander Bartsch</author>
    <author>Thomas Schratzenstaller</author>
    <author>Robert Sattler</author>
    <author>Gareth J. Monkman</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electrical components</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electrical properties and parameters</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Dielectric properties</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electrical resistivity</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Magnetic materials</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Viscoelasticity</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Polymers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Non Newtonian fluids</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Magnetic fluids</value>
    </subject>
    <collection role="institutes" number="FakEI">Fakultät Elektro- und Informationstechnik</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="schratzenstallermd">Schratzenstaller, Thomas (Prof. Dr.) -Labor Medizinprodukte</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="funding" number="">Publikationsfonds der OTH Regensburg</collection>
    <collection role="institutes" number="">Mechatronics Research Unit (MRU)</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/7293/Monkman_AIP_2024.pdf</file>
  </doc>
  <doc>
    <id>2168</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>22</pageLast>
    <pageNumber/>
    <edition/>
    <issue>6</issue>
    <volume>15</volume>
    <type>article</type>
    <publisherName>PLOS</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Experimental and mathematical characterization of coronary polyamide-12 balloon catheter membranes</title>
    <abstract language="eng">The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out. Due to the lack of insights, it is not shown whether isotropic material models can describe the material response of balloon catheter membranes expanded with nominal or higher, supra-nominal pressures. Therefore, for the first time, specimens of commercial polyamide-12 balloon catheters membranes were investigated during uniaxial and biaxial loading scenarios. Furthermore, the influence of kinematic effects on the material response was observed by comparing results from quasi-static and dynamic biaxial extension tests. Novel clamping techniques are described, which allow to test even tiny specimens taken from the balloon membranes. The results of this study reveal the semi-compliant, nonlinear, and viscoelastic character of polyamide-12 balloon catheter membranes. Above nominal pressure, the membranes show a pronounced anisotropic mechanical behavior with a stiffer response in the circumferential direction. The anisotropic feature intensifies with an increasing strain-rate. A modified polynomial model was applied to represent the realistic mechanical response of the balloon catheter membranes during dynamic biaxial extension tests. This study also includes a compact set of constitutive model parameters for the use of the proposed model in future finite element analyses to perform more accurate simulations of expanding balloon catheters.</abstract>
    <parentTitle language="eng">PLoS One</parentTitle>
    <identifier type="doi">10.1371/journal.pone.0234340</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Markus A. Geith</author>
    <author>Jakob D. Eckmann</author>
    <author>Daniel Ch. Haspinger</author>
    <author>Emmanouil Agrafiotis</author>
    <author>Dominik Maier</author>
    <author>Patrick Szabo</author>
    <author>Gerhard Sommer</author>
    <author>Thomas Schratzenstaller</author>
    <author>Gerhard A. Holzapfel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Catheters</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Anisotropy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Polymers</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Viscoelasticity</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Coronary stenting</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Finite element analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Deformation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Adhesives</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="persons" number="schratzenstallermd">Schratzenstaller, Thomas (Prof. Dr.) -Labor Medizinprodukte</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Medizinprodukte</collection>
  </doc>
</export-example>
