<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>8007</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>16</pageNumber>
    <edition/>
    <issue/>
    <volume>43</volume>
    <type>article</type>
    <publisherName>Elsevier BV</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Photodissociation-Driven Photoacoustic Spectroscopy with UV-LEDs for Ozone Detection</title>
    <abstract language="eng">This study presents the development and evaluation of a UV-LED based photoacoustic (PA) measurement system for ozone (O3) detection to demonstrate its potential for low-cost and accurate sensing while for the first time addressing the importance of photodissociation for PA signal generation for O3 in the UV range. With a detection limit of 7.9 ppbV, the system exhibits a significant advancement over state-of-the-art UV-PA O3 detection and is on par with laser-based setups. Following a novel discussion of the PA signal arising from photodissociation and its products, cross-sensitivity effects due to environmental factors such as temperature and gas composition were systematically analyzed. A digital twin driven compensation for these influences was implemented and evaluated. Despite the challenges associated with modeling the effects of H2O and CO2, the PA system shows considerable potential, though further studies in real world applications must be conducted.</abstract>
    <parentTitle language="eng">Photoacoustics</parentTitle>
    <identifier type="issn">2213-5979</identifier>
    <identifier type="doi">10.1016/j.pacs.2025.100718</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-80076</identifier>
    <note>Corresponding author der OTH Regensburg: Lukas Escher</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="CorrespondingAuthor">Lukas Escher</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Lukas Escher</author>
    <author>Thomas Rück</author>
    <author>Simon Jobst</author>
    <author>Jonas Pangerl</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Photoacoustic spectroscopy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>UV-LED</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ozone</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Photodissociation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cross-sensitivity</value>
    </subject>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
    <collection role="funding" number="">DEAL Elsevier</collection>
    <collection role="DFGFachsystematik" number="1">Ingenieurwissenschaften</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/8007/escher_photoacoustics_2025.pdf</file>
  </doc>
  <doc>
    <id>7702</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>12</pageNumber>
    <edition/>
    <issue/>
    <volume>424</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Photoacoustic trace-analysis of breath isoprene and acetone via interband- and Quantum Cascade Lasers</title>
    <abstract language="eng">This research presents two laser-based photoacoustic approaches for analyzing exhaled breath isoprene and acetone. The integration of a PTR-ToF-MS as a reference device ensured the reliability and accuracy of the photoacoustic systems that is based on an ICL for isoprene and a QCL for acetone detection. The calibration yielded limits of detection of 26.9 ppbV and 1.7 ppbV, respectively, and corresponding normalized noise equivalent absorption coefficients (NNEAs) of 5.0E-9 Wcm 1Hz 0.5 and 4.9E-9 Wcm 1Hz 0.5. Laboratory as well as real breath sample measurements from alveolar breath revealed a robust system performance, with only one outlier within the static isoprene measurements. However, discrepancies emerged under dynamic breath sampling conditions, emphasizing the need for further optimization. Especially by knowing the dynamic nature and endogenous origin of exhaled isoprene our findings highlight the potential of breath analysis for non-invasive&#13;
physio-metabolic and pathophysiological monitoring towards point-of-care devices</abstract>
    <parentTitle language="eng">Sensors and Actuators: B. Chemical</parentTitle>
    <identifier type="doi">10.1016/j.snb.2024.136886</identifier>
    <identifier type="urn">urn:nbn:de:bvb:898-opus4-77024</identifier>
    <note>Corresponding author der OTH Regensburg: Jonas Pangerl</note>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="CorrespondingAuthor">Jonas Pangerl</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Jonas Pangerl</author>
    <author>Pritam Sukul</author>
    <author>Thomas Rück</author>
    <author>Lukas Escher</author>
    <author>Wolfram Miekisch</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Photoacoustic spectroscopy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Breath analysis/profiling</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Real-time mass spectrometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isoprene</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Acetone</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="oaweg" number="">Corresponding author der OTH Regensburg</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
    <collection role="funding" number="">DEAL Elsevier</collection>
    <collection role="DFGFachsystematik" number="1">Ingenieurwissenschaften</collection>
    <thesisPublisher>Ostbayerische Technische Hochschule Regensburg</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-oth-regensburg/files/7702/Pangerl_Sensors_Actuators_2025.pdf</file>
  </doc>
</export-example>