<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>3872</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>116</pageNumber>
    <edition/>
    <issue/>
    <volume/>
    <type>report</type>
    <publisherName>National Research Council of Canada. Construction</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Apparent sound insulation in cross-laminated timber buildings</title>
    <abstract language="eng">This Report presents the results from experimental studies of airborne sound transmission, together with an explanation of calculation procedures to predict the apparent airborne sound transmission between adjacent spaces in a building whose construction is based on cross-laminated timber (CLT) panels. There are several types of CLT constructions which are commercially available in Canada, but this study only focused on CLT panels that have adhesive between the faces of the timber elements in adjacent layers, but no adhesive bonding the adjacent timber elements within a given layer. There were noticeable gaps (up to 3 mm wide) between some of the timber elements comprising each layer of the CLT assembly. These CLT panels could be called “Face-Laminated CLT Panels” but are simply referred to as CLT panels in this Report. Another form of CLT panels has adhesive between the faces of the timber elements in adjacent layers as well as adhesive to bond the adjacent timber elements within a given layer. These are referred to as “Fully-Bonded CLT Panels” in this Report. Because fully-bonded CLT panels have different properties than face-laminated CLT panels, the sound transmission data and predictions in this Report do not apply to fully-bonded CLT panels.</abstract>
    <identifier type="doi">10.4224/23002009</identifier>
    <enrichment key="opus.import.date">2022-05-09T14:52:38+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Höller</author>
    <author>Jeffrey Mahn</author>
    <author>David Quirt</author>
    <author>Stefan Schoenwald</author>
    <author>Berndt Zeitler</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16313">Gebäude und Infrastruktur</collection>
  </doc>
  <doc>
    <id>3874</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>report</type>
    <publisherName>National Research Council of Canada. Construction</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Apparent sound insulation in cold-formed steel-framed buildings</title>
    <abstract language="eng">This Report presents the results from substantial experimental studies of sound transmission, together with an explanation of calculation procedures to predict the sound transmission between adjacent spaces in a building whose walls and floors have cold-formed steel (CFS) framing. This first edition contains mainly data for loadbearing steel framing formed from sheet steel with thickness from 1.37 mm (16 gauge) to 0.94 mm (20 gauge). Non-loadbearing CFS studs formed from thinner steel (nominally 0.54 mm) are also commonly used but these are not included in the data tables for sound transmission through wall assemblies in this Report.</abstract>
    <identifier type="doi">10.4224/23001843</identifier>
    <enrichment key="opus.import.date">2022-05-09T14:52:38+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="OtherSeries">Research Report (National Research Council of Canada. Construction) ; RR-337</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Höller</author>
    <author>David Quirt</author>
    <author>Berndt Zeitler</author>
    <author>Ivan Sabourin</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>concrete block walls</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>floor</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>sound insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>sound transmission</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16313">Gebäude und Infrastruktur</collection>
  </doc>
  <doc>
    <id>3926</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Curran Associates, Inc</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2022-05-11</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Apparent sound insulation in cold-formed steel-framed buildings</title>
    <parentTitle language="deu">24th International Congress on Sound and Vibration (ICSV 24), 23-27 July 2017, London, UK</parentTitle>
    <identifier type="url">https://www.iiav.org/icsv24/index.php?va=viewpage&amp;vaid=366</identifier>
    <identifier type="old">978-1-5108-4585-5</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Höller</author>
    <author>David Quirt</author>
    <author>Berndt Zeitler</author>
    <author>Ivan Sabourin</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="othpublikationsherkunft" number="">Externe Publikationen</collection>
    <collection role="othforschungsschwerpunkt" number="16313">Gebäude und Infrastruktur</collection>
  </doc>
</export-example>