    <title language="eng">Re-irradiation of spinal column metastases by IMRT: Impact of setup errors on the dose distribution</title>
    <abstract language="eng">Background&#13;
This study investigates the impact of an automated image guided patient setup correction on the dose distribution for ten patients with in-field IMRT re-irradiation of vertebral metastases.&#13;
Methods&#13;
10 patients with spinal column metastases who had previously been treated with 3D-conformal radiotherapy (3D-CRT) were simulated to have an in-field recurrence. IMRT plans were generated for treatment of the vertebrae sparing the spinal cord. The dose distributions were compared for a patient setup based on skin marks only and a Cone Beam CT (CBCT) based setup with translational and rotational couch corrections using an automatic robotic image guided couch top (Elekta - HexaPOD™ IGuide® - system). The biological equivalent dose (BED) was calculated to evaluate and rank the effects of the automatic setup correction for the dose distribution of CTV and spinal cord.&#13;
Results&#13;
The mean absolute value (± standard deviation) over all patients and fractions of the translational error is 6.1 mm (±4 mm) and 2.7° (±1.1 mm) for the rotational error. The dose coverage of the 95% isodose for the CTV is considerable decreased for the uncorrected table setup. This is associated with an increasing of the spinal cord dose above the tolerance dose.&#13;
Conclusions&#13;
An automatic image guided table correction ensures the delivery of accurate dose distribution and reduces the risk of radiation induced myelopathy.</abstract>
    <parentTitle language="eng">Radiation Oncology</parentTitle>
    <identifier type="doi">10.1186/1748-717X-8-269</identifier>
    <enrichment key="opus.import.date">2022-08-20T07:06:56+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <author>Christian Gröger</author>
    <author>Matthias G. Hautmann</author>
    <author>Rainer Löschel</author>
    <author>Natalia Repp</author>
    <author>Oliver Kölbl</author>
    <author>Barbara Dobler</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CBCT</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Setup error</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>IGRT</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>IMRT</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Spinal metastasis</value>
    </subject>
    <collection role="institutes" number="FakIM">Fakultät Informatik und Mathematik</collection>
    <collection role="othforschungsschwerpunkt" number="16311">Digitalisierung</collection>
  </doc>
</export-example>