<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>1559</id>
    <completedYear/>
    <publishedYear>2015</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-03-21</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Specification of an improved photoacoustic setup for high-sensitive, low-cost NO2 trace gas detection</title>
    <parentTitle language="eng">18th International Conference on Photoacoustic and Photothermal Phenomena (ICPPP18), 2015, September 6-10, Novi Sad, Serbia</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <author>Thomas Rück</author>
    <author>Ferdinand Landgraf</author>
    <author>I. Läpple</author>
    <author>J. Unger</author>
    <author>Frank-Michael Matysik</author>
    <author>Rudolf Bierl</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
  </doc>
  <doc>
    <id>1565</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-03-21</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">A Conductivity Probe for the Determination of Carbon Dioxide Tension at the Oxygenator Exhaust Outlet during Extracorporeal Membrane Oxygenation (ECMO)</title>
    <parentTitle language="eng">analytica Conference 2014, 1. bis 4. April, München</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <author>Bastiaan van der Weerd</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
  </doc>
  <doc>
    <id>1566</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-03-21</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">A Conductivity Probe for the Determination of Carbon Dioxide Tension at the Oxygenator Exhaust Outlet during Extracorporeal Membrane Oxygenation (ECMO)</title>
    <parentTitle language="eng">Electrochemistry 2014, September 22 - 24, Mainz</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <author>Bastiaan van der Weerd</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
  </doc>
  <doc>
    <id>1564</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-03-21</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">A Planar Conductivity Probe for CO2 Determination at the Oxygenator Outlet</title>
    <parentTitle language="deu">Doktorandenseminar GDCh Prozessanalytik 2014, Berlin</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <author>Bastiaan van der Weerd</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
  </doc>
  <doc>
    <id>5442</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Optica Publishing Group</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Creating a Digital Twin of a Photoacoustic Gas Sensor for Methane Detection in Complex Gas Matrices</title>
    <abstract language="deu">We present the calculation results from a digital twin (DT) of our photoacoustic (PA) sensor for methane detection, regarding gas composition, temperature and pressure variations.</abstract>
    <parentTitle language="eng">Proceedings Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES): 11–15 July 2022, Vancouver, British Columbia, Canada</parentTitle>
    <identifier type="doi">10.1364/LACSEA.2022.LW4D.2</identifier>
    <identifier type="isbn">978-1-957171-10-4</identifier>
    <enrichment key="OtherSeries">Technical Digest Series (Optica Publishing Group, 2022), paper LW4D.2.</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Max Müller</author>
    <author>Thomas Rück</author>
    <author>Simon Jobst</author>
    <author>Jonas Pangerl</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
  </doc>
  <doc>
    <id>6538</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Optica Publishing Group</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Using a Modulated Quantum Cascade Laser for Photoacoustic Spectra Recording of Exhaled Acetone and Main Breath Components</title>
    <abstract language="eng">Photoacoustic spectra of main breath components together with acetone are presented demonstrating spectral linearity towards different concentrations and compositions. The acetone 3σ detection limit at 1209 cm−1 is 0.28 ppbV</abstract>
    <parentTitle language="deu">Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES)</parentTitle>
    <identifier type="doi">10.1364/AIS.2022.ATu3G.1</identifier>
    <enrichment key="OtherSeries">Technical Digest Series (Optica Publishing Group, 2022), paper ATu3G.1.</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Jonas Pangerl</author>
    <author>Elisabeth Wittmann</author>
    <author>Stefan Weigl</author>
    <author>Max Müller</author>
    <author>Rudolf Bierl</author>
    <author>Frank-Michael Matysik</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="bierlsappz">Bierl, Rudolf (Prof. Dr.) - Sensorik-ApplikationsZentrum</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Sensorik-Applikationszentrum (SappZ)</collection>
  </doc>