    <title language="eng">Resting motor threshold and magnetic field output of the figure-of-8 and the double-cone coil</title>
    <abstract language="eng">The use of the double-cone (DC) coil in transcranial magnetic stimulation (TMS) is promoted with the notion that the DC coil enables stimulation of deeper brain areas in contrast to conventional figure-of-8 (Fo8) coils. However, systematic comparisons of these two coil types with respect to the spatial distribution of the magnetic field output and also to the induced activity in superficial and deeper brain areas are limited. Resting motor thresholds of the left and right first dorsal interosseous (FDI) and tibialis anterior (TA) were determined with the DC and the Fo8 coil in 17 healthy subjects. Coils were orientated over the corresponding motor area in an angle of 45 degrees for the hand area with the handle pointing in posterior direction and in medio-lateral direction for the leg area. Physical measurements were done with an automatic gantry table using a Gaussmeter. Resting motor threshold was higher for the leg area in contrast to the hand area and for the Fo8 in contrast to the DC coil. Muscle by coil interaction was also significant providing higher differences between leg and hand area for the Fo8 (about 27%) in contrast to the DC coil (about 15%). Magnetic field strength was higher for the DC coil in contrast to the Fo8 coil. The DC coil produces a higher magnetic field with higher depth of penetration than the figure of eight coil.</abstract>
    <parentTitle language="eng">scientific reports</parentTitle>
    <identifier type="doi">10.1038/s41598-020-58034-2</identifier>
    <enrichment key="opus.import.date">2022-01-27T15:33:58+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Martin Schecklmann</author>
    <author>Maximilian Schmausser</author>
    <author>Felix Klinger</author>
    <author>Peter M. Kreuzer</author>
    <author>Lars Krenkel</author>
    <author>Berthold Langguth</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ANTERIOR CINGULATE CORTEX</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CONNECTIVITY</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Depression</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FRONTAL-CORTEX</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>PREDICTOR</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>RTMS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>STIMULATION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>TMS</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="oaweg" number="">Hybrid Open Access - OA-Veröffentlichung in einer Subskriptionszeitschrift/-medium</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5803</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>922</pageFirst>
    <pageLast>928</pageLast>
    <pageNumber/>
    <edition/>
    <issue>8</issue>
    <volume>66</volume>
    <type>article</type>
    <publisherName>Lippincott Williams &amp; Wilkins</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study</title>
    <abstract language="eng">Coagulative disorders, especially clotting during extracorporeal membrane oxygenation, are frequent complications. Direct visualization and analysis of deposits in membrane oxygenators using computed tomography (CT) may provide an insight into the underlying mechanisms causing thrombotic events. However, the already established multidetector CT1 (MDCT) method shows major limitations. Here, we demonstrate the feasibility of applying industrial micro-CT (μCT) to circumvent these restrictions. Three clinically used membrane oxygenators were investigated applying both MDCT and μCT.&#13;
The scans were analyzed in terms of clot volume and local clot distribution. As validation, the clot volume was also determined from the fluid volume, which could be filled into the respective used oxygenator compared to a new device. In addition, cross-sectional CT images were compared with crosscut oxygenators. Based on the μCT findings, a morphological measure (sphericity) for assessing clot structures in membrane oxygenators is introduced. Furthermore, by comparing MDCT and μCT results, an augmentation of the MDCT method is proposed, which allows for improved clot volume determination in a clinical setting.</abstract>
    <parentTitle language="eng">ASAIO Journal / American Society for Artificial Internal Organs</parentTitle>
    <identifier type="doi">10.1097/MAT.0000000000001089</identifier>
    <identifier type="issn">1538-943X</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Clemens Birkenmaier</author>
    <author>Christian Dornia</author>
    <author>Karla Lehle</author>
    <author>Thomas Müller</author>
    <author>Michael Gruber</author>
    <author>Alois Philipp</author>
    <author>Lars Krenkel</author>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmpub">Krenkel, Lars (Prof. Dr.), Publikationen - Labor Biofluidmechanik</collection>
  </doc>
</export-example>