<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>954</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>38</volume>
    <type>article</type>
    <publisherName>AIP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Silicon Chip Field Emission Electron Source Fabricated by Laser Micromachining</title>
    <abstract language="eng">The components for a silicon chip electron source were fabricated by laser micromachining using pulsed laser ablation and wet chemical cleaning and etching dips. The field emission electron source consists of a silicon field emission cathode with 4 × 4 conical shaped emitters with a height of 250 μm and a tip radius of about 50 nm, a 50 μm thick laser-structured mica spacer, and a silicon grid electrode with a grid periodicity of 200 μm and a bar width of 50 μm. These three components are combined to a single chip with the size of 14 × 10 mm2 and the thickness of 1 mm to form the electron source. Several of these devices were characterized in ultrahigh vacuum. Onset voltages of about 165 V and cathode currents of about 15 μA for voltages lower than 350 V were observed. Operating the electron source with an anode voltage of 500 V and an extraction grid voltage of 300 V yielded a cathode current of 4.5 μA ± 8.9%, an anode current of 4.0 μA ± 9.6%, and a corresponding grid transmittance of 89%. Regulating the anode current by the extraction grid voltage, an extremely stable anode current of 5.0 μA ± 0.017% was observed. A long-term measurement over 120 h was performed, and no significant degradation or failure was observed.</abstract>
    <parentTitle language="deu">Journal of Vacuum Science &amp; Technology B</parentTitle>
    <identifier type="doi">10.1116/1.5134872</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Langer</author>
    <author>Vitali Bomke</author>
    <author>Matthias Hausladen</author>
    <author>Robert Damian Ławrowski</author>
    <author>Christian Prommesberger</author>
    <author>Michael Bachmann</author>
    <author>Rupert Schreiner</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ultra-high vacuum</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Field emitter arrays</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Etching</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electrical properties and parameters</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electron sources</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser ablation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser micromachining</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Silicon chip</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Triodes</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlm">Schreiner, Rupert (Prof. Dr.), Zeitschriftenaufsätze - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>1059</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>2</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>IEEE</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2021-02-04</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Individually Addressable Fully Integrated Field Emission Electron Source Fabricated by Laser Micromachining of Silicon</title>
    <abstract language="eng">A cathode with individually addressable Si tips allows the observation of the activation procedure and emission behaviour of each field emission emitter at any time of the measurement. The cathode consists of an array of 2x2 conically shaped emitter structures, which were fabricated by laser micromachining and wet etching of a Si substrate bonded on a glass carrier. Using the same process, a Si extractions grid was fabricated and mounted onto the emitter. Integral field emission measurements were performed in a diode configuration in a vacuum chamber at pressures of about 10- 9 mbar. The emitters show an onset voltage between 200 V and 300 V. The emission current for each emitter on the cathode was regulated to a given value (1.0 μA, 2.5μA, 5.0μA) by an external regulating circuit and was recorded individually during the measurement. With such approach, the relation between the emission behaviour and the geometry of emitters can be studied in detail. In addition, the current stabilization of each emitters of an array can be investigated, which led to a current stability of better than 0.5%.</abstract>
    <parentTitle language="eng">33rd International Vacuum Nanoelectronics Conference (IVNC): 6-10 July 2020, Lyon</parentTitle>
    <identifier type="doi">10.1109/IVNC49440.2020.9203470</identifier>
    <identifier type="isbn">978-1-7281-9454-7</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Robert Damian Ławrowski</author>
    <author>Matthias Hausladen</author>
    <author>Rupert Schreiner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>2981</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>2</issue>
    <volume>38</volume>
    <type>article</type>
    <publisherName>AIP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Vacuum-sealed field emission electron gun</title>
    <abstract language="eng">A compact vacuum-sealed field emission electron gun with an operation voltage below 5 kV is presented. With a 150 nm thick pyrolytic carbon membrane, a transmission of 40% at 5 kV is obtained. For more than 2500 h of continuous operation at an emission current of 100 nA, no significant increase (&lt;50V ) and almost no degradation were found. From this measurement, a lifetime of more than 10 000 h at continuous operation with approximately a linear increase of the extraction voltage from about 545 V to about 730 V is predicted. This electron source enables application of field emitter arrays in poor vacuum or even ambient pressure.&#13;
ACKNOWLEDGMENT&#13;
This work was supported by the German Federal Ministry for Economic Affairs and Energy under Project No. ZF4081502GM8. C.P., R.L., M.H., and R.S. were supported by Grant No. ZF4562901GM8.</abstract>
    <parentTitle language="eng">Journal of Vacuum Science &amp; Technology B</parentTitle>
    <identifier type="doi">10.1116/1.5139316</identifier>
    <enrichment key="opus.import.date">2022-02-18T18:44:39+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Michael Bachmann</author>
    <author>Felix Düsberg</author>
    <author>Christoph Langer</author>
    <author>Florian Herdl</author>
    <author>Lukas Bergbreiter</author>
    <author>Florian Dams</author>
    <author>Natuski Miyakawa</author>
    <author>Tobias Eggert</author>
    <author>Andreas Pahlke</author>
    <author>Simon Edler</author>
    <author>Christian Prommesberger</author>
    <author>Robert Damian Ławrowski</author>
    <author>Matthias Hausladen</author>
    <author>Rupert Schreiner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlm">Schreiner, Rupert (Prof. Dr.), Zeitschriftenaufsätze - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>3534</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferencesummary</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-05-29</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Individually Addressable Silicon Field Emission Cathodes Fabricated by Laser Micromachining</title>
    <parentTitle language="eng">7th ITG International Vacuum Electronics Workshop (IVEW) 2020 and 13th International Vacuum Electron Sources Conference (IVeSC) 2020, 26. - 29.5.2020, Bad Honnef</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <author>Robert Damian Ławrowski</author>
    <author>Matthias Hausladen</author>
    <author>Rupert Schreiner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>3533</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferencesummary</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2020-05-29</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Fast Pulse Source for Field Emission Applications</title>
    <parentTitle language="eng">7th ITG International Vacuum Electronics Workshop (IVEW) 2020 and 13th International Vacuum Electron Sources Conference (IVeSC) 2020, 26. - 29.5.2020, Bad Honnef</parentTitle>
    <enrichment key="opus.source">publish</enrichment>
    <author>Matthias Hausladen</author>
    <author>Robert Damian Ławrowski</author>
    <author>Rupert Schreiner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
</export-example>
