<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>2549</id>
    <completedYear/>
    <publishedYear>2019</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>828</pageFirst>
    <pageLast>834</pageLast>
    <pageNumber/>
    <edition/>
    <issue>6</issue>
    <volume>39</volume>
    <type>article</type>
    <publisherName>Emerald</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Sensor system for use with low intensity pulsed ultrasound</title>
    <abstract language="eng">Purpose Ultrasound is a well-established technology in medical science, though many of the conventional measurement systems (hydrophones and radiation force balances [RFBs]) often lack accuracy and tend to be expensive. This is a significant problem where sensors must be considered to be "disposable" because they inevitably come into contact with biological fluids and expense increases dramatically in cases where a large number of sensors in array form are required. This is inevitably the case where ultrasound is to be used for the in vitro growth stimulation of a large plurality of biological samples in tissue engineering. Traditionally only a single excitation frequency is used (typically 1.5 MHz), but future research demands a larger choice of wavelengths for which a single broadband measurement transducer is desirable. Furthermore, because of implementation conditions there can also be large discrepancies between measurements. The purpose of this paper deals with a very cost-effective alternative to expensive RFBs and hydrophones. Design/methodology/approach Utilization of cost-effective piezoelectric elements as broadband sensors. Findings Very effective results with equivalent (if not better) accuracy than expensive alternatives. Originality/value This paper concentrates on how very cost-effective piezoelectric ultrasound transducers can be implemented as sensors for ultrasound power measurements with accuracy as good, if not better than those achievable using radiation force balances or hydrophones.</abstract>
    <parentTitle language="eng">Sensor review</parentTitle>
    <identifier type="doi">10.1108/SR-11-2018-0304</identifier>
    <identifier type="issn">0260-2288</identifier>
    <enrichment key="opus.import.date">2022-01-27T15:10:05+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Andreas Diermeier</author>
    <author>Dirk Sindersberger</author>
    <author>Peter Angele</author>
    <author>Richard Kujat</author>
    <author>Gareth J. Monkman</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>BALANCE</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Hydrophone</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Mesenchymal stem cell</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Piezoelectric transducer</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Radiation force balance</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Sensors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>therapy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tissue engineering</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ultrasound</value>
    </subject>
    <collection role="institutes" number="FakEI">Fakultät Elektro- und Informationstechnik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Mechatronics Research Unit (MRU)</collection>
  </doc>
  <doc>
    <id>5157</id>
    <completedYear/>
    <publishedYear>2008</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>361</pageFirst>
    <pageLast>368</pageLast>
    <pageNumber/>
    <edition/>
    <issue>4</issue>
    <volume>35</volume>
    <type>article</type>
    <publisherName>MCB Univ. Press</publisherName>
    <publisherPlace>Bradford</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Optimisation of Prehension Force through Tactile Sensing</title>
    <abstract language="eng">Purpose&#13;
The purpose of this paper is to analyze surface deformations caused by shear and moment forces on tactile materials and present a method to detect and reduce the risk of slippage by controlling the normal force as measured by tactile sensor arrays.&#13;
&#13;
Design/methodology/approach&#13;
A predictive model has been proposed which uses a basic method adapted to real applications in grasp optimization. Prevention of premature release with minimum prehension force is addressed without the need to measure the coefficient of friction between object and robot gripper. Predictive models have been used to develop a set of rules which predict the pre‐slip based on fluctuations in tactile signal data.&#13;
&#13;
Findings&#13;
The tactile sensors can be used in a “nonlinear” manner during manipulation tasks. When the gripper finger first makes contact with an object, the stress distribution under the finger skin varies rapidly. Predictive models have been used to develop a set of rules which predict the pre‐slip based on fluctuations in tactile signal data. Pre‐slip at the contact area just prior to object movement produces rapid but detectable stress transients.&#13;
&#13;
Originality/value&#13;
Tactile sensors do not measure stress generated by a contact with an object directly, but instead measure strain in an interposed compliant, polymeric medium intended for sensor protection and prehension assistance. Reliable detection of pre‐slip has hitherto eluded researchers using such tactile techniques.</abstract>
    <parentTitle language="eng">Industrial Robot</parentTitle>
    <identifier type="doi">10.1108/01439910810876454</identifier>
    <enrichment key="opus.import.date">2022-08-10T13:23:02+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">false</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Somrak Petchartee</author>
    <author>Gareth J. Monkman</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Sensors</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tactile sensors</value>
    </subject>
    <collection role="institutes" number="FakEI">Fakultät Elektro- und Informationstechnik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Mechatronics Research Unit (MRU)</collection>
  </doc>