<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>867</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>April</issue>
    <volume>305</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">MEMS-based thermal conductivity sensor for hydrogen gas detection in automotive applications</title>
    <abstract language="eng">Accurate detection of hydrogen gas in vehicle interiors is very important for the future of a fuel cell car. Since this type of gas is highly volatile and flammable, the measurement methods have to be very reliable and precise due to safety reasons. In this paper a thermal conductivity sensor for hydrogen gas detection is presented, exhibiting a lower detection limit of 2000 ppm hydrogen in laboratory air. The sensor element is realized by micro-fabrication techniques on silicon wafers. The heated filament is exposed by a selective wet etching process creating a micro-hotplate on a thin membrane. In order to minimize power consumption, the sensor is operated in pulsed mode. Hydrogen gas detection was carried out using a synthetic gas testbench. Measurements of hydrogen contents ranging from 0% to 4% with an increment of 0.5% were successfully performed for ambient gas temperatures between -15°C and 84°C. Including humidity, high moisture contents have the greatest influence on thermal conductivity. This was predicted in theoretical investigations and confirmed in experiments. For evaluation, both the change in resistance ΔR as well as the time constant τ were taken as sensor output. For both quantities, the previously established theoretical relationship with thermal conductivity could be confirmed.</abstract>
    <parentTitle language="eng">Sensors and Actuators A: Physical</parentTitle>
    <identifier type="doi">10.1016/j.sna.2019.111670</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Dominik Berndt</author>
    <author>Josef Muggli</author>
    <author>Franz Wittwer</author>
    <author>Christoph Langer</author>
    <author>Stephan Heinrich</author>
    <author>Thorsten Knittel</author>
    <author>Rupert Schreiner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlm">Schreiner, Rupert (Prof. Dr.), Zeitschriftenaufsätze - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>954</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>38</volume>
    <type>article</type>
    <publisherName>AIP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Silicon Chip Field Emission Electron Source Fabricated by Laser Micromachining</title>
    <abstract language="eng">The components for a silicon chip electron source were fabricated by laser micromachining using pulsed laser ablation and wet chemical cleaning and etching dips. The field emission electron source consists of a silicon field emission cathode with 4 × 4 conical shaped emitters with a height of 250 μm and a tip radius of about 50 nm, a 50 μm thick laser-structured mica spacer, and a silicon grid electrode with a grid periodicity of 200 μm and a bar width of 50 μm. These three components are combined to a single chip with the size of 14 × 10 mm2 and the thickness of 1 mm to form the electron source. Several of these devices were characterized in ultrahigh vacuum. Onset voltages of about 165 V and cathode currents of about 15 μA for voltages lower than 350 V were observed. Operating the electron source with an anode voltage of 500 V and an extraction grid voltage of 300 V yielded a cathode current of 4.5 μA ± 8.9%, an anode current of 4.0 μA ± 9.6%, and a corresponding grid transmittance of 89%. Regulating the anode current by the extraction grid voltage, an extremely stable anode current of 5.0 μA ± 0.017% was observed. A long-term measurement over 120 h was performed, and no significant degradation or failure was observed.</abstract>
    <parentTitle language="deu">Journal of Vacuum Science &amp; Technology B</parentTitle>
    <identifier type="doi">10.1116/1.5134872</identifier>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Langer</author>
    <author>Vitali Bomke</author>
    <author>Matthias Hausladen</author>
    <author>Robert Damian Ławrowski</author>
    <author>Christian Prommesberger</author>
    <author>Michael Bachmann</author>
    <author>Rupert Schreiner</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ultra-high vacuum</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Field emitter arrays</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Etching</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electrical properties and parameters</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Electron sources</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser ablation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser micromachining</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Silicon chip</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Triodes</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlm">Schreiner, Rupert (Prof. Dr.), Zeitschriftenaufsätze - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16316">Produktion und Systeme</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>2981</id>
    <completedYear/>
    <publishedYear>2020</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>2</issue>
    <volume>38</volume>
    <type>article</type>
    <publisherName>AIP Publishing</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Vacuum-sealed field emission electron gun</title>
    <abstract language="eng">A compact vacuum-sealed field emission electron gun with an operation voltage below 5 kV is presented. With a 150 nm thick pyrolytic carbon membrane, a transmission of 40% at 5 kV is obtained. For more than 2500 h of continuous operation at an emission current of 100 nA, no significant increase (&lt;50V ) and almost no degradation were found. From this measurement, a lifetime of more than 10 000 h at continuous operation with approximately a linear increase of the extraction voltage from about 545 V to about 730 V is predicted. This electron source enables application of field emitter arrays in poor vacuum or even ambient pressure.&#13;
ACKNOWLEDGMENT&#13;
This work was supported by the German Federal Ministry for Economic Affairs and Energy under Project No. ZF4081502GM8. C.P., R.L., M.H., and R.S. were supported by Grant No. ZF4562901GM8.</abstract>
    <parentTitle language="eng">Journal of Vacuum Science &amp; Technology B</parentTitle>
    <identifier type="doi">10.1116/1.5139316</identifier>
    <enrichment key="opus.import.date">2022-02-18T18:44:39+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Michael Bachmann</author>
    <author>Felix Düsberg</author>
    <author>Christoph Langer</author>
    <author>Florian Herdl</author>
    <author>Lukas Bergbreiter</author>
    <author>Florian Dams</author>
    <author>Natuski Miyakawa</author>
    <author>Tobias Eggert</author>
    <author>Andreas Pahlke</author>
    <author>Simon Edler</author>
    <author>Christian Prommesberger</author>
    <author>Robert Damian Ławrowski</author>
    <author>Matthias Hausladen</author>
    <author>Rupert Schreiner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlm">Schreiner, Rupert (Prof. Dr.), Zeitschriftenaufsätze - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
</export-example>
