<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>3110</id>
    <completedYear/>
    <publishedYear>2016</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>15</pageFirst>
    <pageLast>24</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>174</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Design, realization and testing of an adsorption refrigerator based on activated carbon/ethanol working pair</title>
    <abstract language="eng">In the present paper design, realization and testing of a novel small scale adsorption refrigerator prototype based on activated carbon/ethanol working pair is described. Firstly, experimental activity has been carried out for identification of the best performing activated carbon available on the market, through the evaluation of the achievable thermodynamic performance both under air conditioning and refrigeration conditions. Once identified the best performing activated carbon, the design of the adsorber was developed by experimental dynamic performance analysis, carried out by means of the Gravimetric-Large Temperature Jump (G-LTJ) apparatus available at CNR ITAE lab. Finally, the whole 0.5 kW refrigerator prototype was designed and built. First experimental results both under reference air conditioning and refrigeration cycles have been reported, to check the achievable performance. High Specific Cooling Powers (SCPs), 95 W/kg and 50 W/kg, for air conditioning and refrigeration respectively, were obtained, while the COP ranged between 0.09 and 0.11, thus showing an improvement of the current state of the art. (C) 2016 Elsevier Ltd. All rights reserved.</abstract>
    <parentTitle language="eng">Applied Energy</parentTitle>
    <identifier type="doi">10.1016/j.apenergy.2016.04.080</identifier>
    <enrichment key="opus.import.date">2022-03-17T06:05:16+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Andrea Frazzica</author>
    <author>Valeria Palomba</author>
    <author>Belal Dawoud</author>
    <author>Giuseppe Gullì</author>
    <author>Vincenza Brancato</author>
    <author>Alessio Sapienza</author>
    <author>Salvatore Vasta</author>
    <author>Angelo Freni</author>
    <author>Fabio Costa</author>
    <author>Giovanni Restuccia</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Activated carbon</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ADSORBENTS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>adsorption</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ammonia</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CARBON</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CHILLER</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>COOLING SYSTEMS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Corrosion</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>DRIVEN</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ethanol</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ETHANOL ADSORPTION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>PERFORMANCE</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Refrigeration</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>waste heat</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othforschungsschwerpunkt" number="16312">Energie und Mobilität</collection>
    <collection role="institutes" number="">Labor Heizungs- und Klimatechnik</collection>
  </doc>
  <doc>
    <id>2554</id>
    <completedYear/>
    <publishedYear>2021</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>8</issue>
    <volume>11</volume>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Thermodynamic Performance of Adsorption Working Pairs for Low-Temperature Waste Heat Upgrading in Industrial Applications</title>
    <abstract language="eng">The present work aims at the thermodynamic analysis of different working pairs in adsorption heat transformers (AdHT) for low-temperature waste heat upgrade in industrial processes. Two different AdHT configurations have been simulated, namely with and without heat recovery between the adsorbent beds. Ten working pairs, employing different adsorbent materials and four different refrigerants, have been compared at varying working boundary conditions. The effects of heat recovery and the presence of a temperature gradient for heat transfer between sinks/sources and the AdHT components have been analyzed. The achieved results demonstrate the possibility of increasing the overall performance when internal heat recovery is implemented. They also highlight the relevant role played by the existing temperature gradient between heat transfer fluids and components, that strongly affect the real operating cycle of the AdHT and thus its expected performance. Both extremely low, i.e., 40-50 degrees C, and low (i.e., 80 degrees C) waste heat source temperatures were investigated at variable ambient temperatures, evaluating the achievable COP and specific energy. The main results demonstrate that optimal performance can be achieved when 40-50 K of temperature difference between waste heat source and ambient temperature are guaranteed. Furthermore, composite sorbents demonstrated to be the most promising adsorbent materials for this application, given their high sorption capacity compared to pure adsorbents, which is reflected in much higher achievable specific energy.</abstract>
    <parentTitle language="eng">Applied Sciences</parentTitle>
    <identifier type="doi">10.3390/app11083389</identifier>
    <enrichment key="opus.import.date">2022-01-27T15:10:05+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Andrea Frazzica</author>
    <author>Valeria Palomba</author>
    <author>Belal Dawoud</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>adsorption</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>efficiency</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>heat transformer</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>heat upgrading</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>waste heat</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>working pairs</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="oaweg" number="">Gold Open Access- Erstveröffentlichung in einem/als Open-Access-Medium</collection>
    <collection role="othforschungsschwerpunkt" number="16312">Energie und Mobilität</collection>
    <collection role="institutes" number="">Labor Sorptionsprozesse</collection>
  </doc>
  <doc>
    <id>3182</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>322</pageFirst>
    <pageLast>333</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>142</volume>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">On the impact of different management strategies on the performance of a two-bed activated carbon/ethanol refrigerator: An experimental study</title>
    <abstract language="eng">In the present work, an experimental study on a lab-scale adsorption refrigerator, based on activated carbon/ethanol working pair is reported. An extensive testing campaign has been carried out at the CNR ITAE laboratory, with multiple aims. First, the performance has been evaluated in terms of both COP and Specific Cooling Power (SCP), under different boundary conditions, including both air conditioning and refrigeration applications. Attractive SCPs, up to 180 W/kg and 70 W/kg for air conditioning and refrigeration, respectively, were measured. Under the same conditions, COP between 0.17 and 0.08 were obtained. In addition, different management strategies, namely, heat recovery between adsorbers and re-allocation of phase durations, were evaluated to identify their influence on the system. Both strategies confirmed the possibility of increasing COP and SCP up to 40% and 25%, respectively. Moreover, a design analysis based on the experimental results has been carried out, to suggest possible improvements of the system. The obtained results demonstrated the possibility of employing a non-toxic refrigerant like ethanol reaching performance comparable with other harmful refrigerants like ammonia and methanol. (C) 2017 Elsevier Ltd. All rights reserved.</abstract>
    <parentTitle language="eng">Energy conversion and management</parentTitle>
    <identifier type="doi">10.1016/j.enconman.2017.03.055</identifier>
    <enrichment key="opus.import.date">2022-03-17T06:53:51+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Valeria Palomba</author>
    <author>Belal Dawoud</author>
    <author>Alessio Sapienza</author>
    <author>Salvatore Vasta</author>
    <author>Andrea Frazzica</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Activated carbon</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Adsorption refrigeration</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ADSORPTION REFRIGERATOR</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CARBON</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Corrosion</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>DRIVEN</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>DYNAMICS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ethanol</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>ETHANOL ADSORPTION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>experimental testing</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>HEAT-RECOVERY</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>IMPROVEMENT</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Management strategy</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MASS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>waste heat</value>
    </subject>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="othforschungsschwerpunkt" number="16312">Energie und Mobilität</collection>
    <collection role="institutes" number="">Labor Heizungs- und Klimatechnik</collection>
  </doc>
</export-example>