<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>3300</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>696</pageFirst>
    <pageLast>699</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>AMA Service GmbH</publisherName>
    <publisherPlace>Wunstorf</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Multilyzer - microfluidic online measuring system for the analysis of environmentally relevant substances</title>
    <parentTitle language="eng">AMA Conferences 2017 : Proceedings : SENSOR 2017 / Nürnberg 2017-05-30 - 2017-06-01</parentTitle>
    <identifier type="isbn">978-3-9816876-4-4</identifier>
    <identifier type="doi">10.5162/sensor2017/P5.2</identifier>
    <enrichment key="opus.import.date">2022-03-29T06:25:40+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Barbora Blahníková</author>
    <author>D. Müller</author>
    <author>M. Waas</author>
    <author>Alfred Lechner</author>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Nanoanalytik und Halbleiterchemie (Nanochem)</collection>
  </doc>
  <doc>
    <id>4655</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>382</pageFirst>
    <pageLast>385</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>bookpart</type>
    <publisherName>VDE-Verlag</publisherName>
    <publisherPlace>München</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Multilyzer - Mikrofluidisches Echtzeitmesssystem für die Analyse umweltrelevanter Substanzen</title>
    <abstract language="deu">Die übermäßige Verwendung von stickstoffbasierten Düngemitteln in der Landwirtschaft stellt eine Gefährdung für die Umwelt und Lebewesen dar. So ist die Analyse von Boden- und Grundwasser zu einem wesentlichen Bestandteil der Nachhaltigkeit und der ökologischen Erhaltung geworden. Dafür bietet der Multilyzer eine passende Lösung. Der Multilyzer ist ein mikrofluidisches Analysesystem zur Bestimmung niedrigster Konzentrationen von Nitrat, Nitrit und Ammonium, die alle wesentliche Bestandteile des Stickstoffkreislaufs sind. Welche bei Übermäßiger Aufnahme im Körper krebserregend wirken und den Sauerstofftransport im Blutkreislauf stören. Der Aufbau ist eine Kombination aus Absorptions- und Fluoreszenzspektroskopie. Der Betrieb mit einer 12 Volt Batterie ermöglicht die Verwendung des Multilyzer-Systems zur Online-Messung im Feld. Somit können sehr kurze Analysezeiten realisiert und der Einfluss von Umwandlungs- bzw. Abbauprozessen vermieden werden. Das gesamte Messsystem wird im Kompetenzzentrum Nanochem an der OTH Regensburg entwickelt, inklusive Fertigungstechnologien, Software- und Hardwaresteuerung.</abstract>
    <abstract language="eng">Excessive use of nitrogen based fertilizers in agriculture represents an environmental hazard. Thus, analysis of soil water and groundwater has become an essential part of sustainability and ecological preservation. On this account, the Multilyzer provides a suitable solution. The Multilyzer is a microfluidic measuring system for the determination of lowest concentrations of nitrate, nitrite and ammonium, which are essential components of the nitrogen cycle. The measurement combines the principles of absorption and fluorescence spectroscopy. As a transportable unit, online measurements can be carried out using a 12 Volts battery power supply. Consequently, the influence of conversion and degradation processes can be avoided. The complete device is developed at the Centre of Excellence Nanochem at OTH Regensburg including fabrication technologies, software and hardware control.</abstract>
    <parentTitle language="deu">7. MikroSystemTechnik Kongress "MEMS, Mikroelektronik, Systeme", 23.-25. Oktober 2017, München</parentTitle>
    <additionalTitle language="deu">Multilyzer - Microfluidic Online Measuring System for the Analysis of Environmentally Relevant Substances</additionalTitle>
    <identifier type="isbn">978-3-8007-4491-6</identifier>
    <enrichment key="opus.import.date">2022-07-03T14:30:54+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Barbora Blahníková</author>
    <author>D. Müller</author>
    <author>M. Waas</author>
    <author>Alfred Lechner</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Absorptionsspektroskopie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Ammonium</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Analysensystem</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Blutkreislauf</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Bodenwasser</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Düngemittel</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Echtzeitsystem</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Fluoreszenzspektroskopie</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Messgerät</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Messsystem</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Mikrofluidik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Nachhaltigkeit</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Nitrat</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Nitrit</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Online-Messung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Programmsteuerung</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Stickstoff</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="institutes" number="FakIM">Fakultät Informatik und Mathematik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Nanoanalytik und Halbleiterchemie (Nanochem)</collection>
  </doc>
</export-example>
