<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>3699</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>222</pageFirst>
    <pageLast>223</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>IEEE</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">High aspect ratio silicon tip cathodes for application in field emission electron sources</title>
    <abstract language="eng">Precisely aligned arrays of sharp tip structures on top of elongated pillars were realized by using an improved fabrication process including an additional inductively-coupled-plasma reactive-ion etching step. Arrays of n-type and p-type silicon with 271 tips have been fabricated and investigated. Those structures have a total height of 5–6 µm and apex radii less than 20nm. Integral field emission measurements of the arrays yielded low onset-fields in the range of 8–12V=µm and field enhancement factors between 300 and 700. The I-E curves of n-type structures showed the usual Fowler-Nordheim behaviour, whereas p-type structures revealed a significant saturation region due to the limited number of electrons in the conduction band and a further carrier depletion effect caused by the pillar. The maximum integral current in the saturation region was 150 nA at fields above 30V=µm. An excellent stability of the emission current of less than ± 2% fluctuation was observed in the saturation region. For n-type Si a maximum integral current of 10 µA at 24V=µm and an average current stability with a fluctuation of ± 50% were measured.</abstract>
    <parentTitle language="eng">2014 27th International Vacuum Nanoelectronics Conference (IVNC), 6-10 July 2014, Engelberg, Switzerland</parentTitle>
    <identifier type="doi">10.1109/IVNC.2014.6894824</identifier>
    <enrichment key="opus.import.date">2022-04-28T18:45:44+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Langer</author>
    <author>Robert Damian Ławrowski</author>
    <author>Christian Prommesberger</author>
    <author>Florian Dams</author>
    <author>Pavel Serbun</author>
    <author>Michael Bachmann</author>
    <author>Günter Müller</author>
    <author>Rupert Schreiner</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Current measurement</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Etching</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FABRICATION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emission</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emitter array</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>GEOMETRY</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Iron</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Sensor arrays</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>silicon</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>silicon tip</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
  <doc>
    <id>3732</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>193</pageFirst>
    <pageLast>194</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>IEEE</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Fabrication and simulation of silicon structures with high aspect ratio for field emission devices</title>
    <abstract language="eng">To obtain higher field enhancement factors of Si-tip structures, we present an improved fabrication process utilizing reactive-ion etching (RIE) with an inductively coupled plasma (ICP). In our design, a pillar under the tips is realized by a combination of RIE with ICP. With adjusted power settings (≈ 240 W) and step times (&lt;; 5 s), vertical slopes with a low roughness of approximately 10 nm to 20 nm are possible. The remaining silicon is oxidized thermally to sharpen the emitters. A final tip radius of R &lt;; 20 nm is obtained for the tips of the emitters. The pillar height HP can be mainly adjusted by the duration of the ICP-etching step. A total emitter height of H ≈ 6 μm with a pillar height of HP ≈ 5 μm is achieved. Simulations with COMSOL Multiphysics® are applied to calculate the field enhancement factor β. A two-dimensional model is used in rotational symmetry. In addition to the previous model, a pillar with a varying diameter ØP and height HP is added. A conventional emitter (H = 1 μm and R = 20 nm) placed on a pillar of the height HP ≈ 5 μm approximately results in a three times higher β-factor (β≈ 105). By decreasing the diameter ØP a slight increase of the β-factor is observed. However, the aspect ratio of the emitter mainly influences on the β-factor.</abstract>
    <parentTitle language="eng">2014 27th International Vacuum Nanoelectronics Conference (IVNC), 6-10 July 2014, Engelberg, Switzerland</parentTitle>
    <identifier type="doi">10.1109/IVNC.2014.6894805</identifier>
    <enrichment key="opus.import.date">2022-04-28T18:57:25+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">false</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Robert Damian Ławrowski</author>
    <author>Christoph Langer</author>
    <author>Christian Prommesberger</author>
    <author>Florian Dams</author>
    <author>Michael Bachmann</author>
    <author>Rupert Schreiner</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Anodes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CATHODES</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FABRICATION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emission</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emitter array</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field enhancement factor</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Iterative closest point algorithm</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Lead</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>silicon tips</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
  </doc>
  <doc>
    <id>3772</id>
    <completedYear/>
    <publishedYear>2015</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>104</pageFirst>
    <pageLast>105</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>IEEE</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Enhanced field emission from p-doped black silicon on pillar structures</title>
    <abstract language="eng">Aligned square arrays of black silicon (b-Si) on top of pillars were fabricated on p-type silicon substrate by a deep-etching step combined with a b-Si process. Two 10×10 arrays with pillar heights of 8 μm and 20 μm and one b-Si reference sample without pillars were investigated. Integral field emission (FE) measurements of the arrays yielded rather low onset-fields between 6.4 V/μm and 13.5 V/μm and field enhancement factors between 430 and 800. The I-V curves showed typical Fowler-Nordheim behavior for low fields, whereas a saturation region was observed at higher fields. The maximum integral current in the saturation region was 8 μA at a field of 20 V/μm. The stability of the emission current was investigated over 3 hours and revealed moderate fluctuations of ± 8% in the saturation region. Voltage scans showed well-aligned FE from nearly all pillars.</abstract>
    <parentTitle language="eng">2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China</parentTitle>
    <identifier type="doi">10.1109/IVNC.2015.7225547</identifier>
    <enrichment key="opus.import.date">2022-04-28T19:28:04+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Christoph Langer</author>
    <author>Christian Prommesberger</author>
    <author>Robert Damian Ławrowski</author>
    <author>F. Müller</author>
    <author>Rupert Schreiner</author>
    <author>Pavel Serbun</author>
    <author>Günter Müller</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>black silicon</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CATHODES</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Current measurement</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Etching</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>FABRICATION</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emission</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>field emitter array</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Iron</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>silicon</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Vacuum technology</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
</export-example>
