<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>4540</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Snow Load Monitoring - Measure to Control Reliability of the Roof of a Stadium</title>
    <abstract language="deu">This contribution shows how monitoring can be used to control reliability of a structure not complying with the requirements of Eurocodes. A general methodology to obtain cost-optimal decisions using limit state design, probabilistic reliability analysis and cost&#13;
estimates is utilised in a full-scale case study dealing with the roof of a stadium located in Northern Italy. The results demonstrate the potential of monitoring systems and probabilistic reliability analysis to support decisions regarding safety measures such as&#13;
snow removal, or temporary closure of the stadium.</abstract>
    <parentTitle language="eng">International Conference Structural Reliability &amp; Modelling in Mechanics, 24.-25.05.2018, Ostrava, Czech Republic</parentTitle>
    <identifier type="url">www.researchgate.net/publication/325569518_Snow_Load_Monitoring_-_Measure_to_Control_Reliability_of_the_Roof_of_a_Stadium</identifier>
    <enrichment key="opus.import.date">2022-06-21T16:17:32+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Miroslav Sýkora</author>
    <author>Dimitris Diamantidis</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cost optimisation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>decision making criteria</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Eurocodes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>monitoring</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>reliability analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>snow load</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>stadium roof</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>standard</value>
    </subject>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="FakBau">Fakultät Bauingenieurwesen</collection>
    <collection role="othforschungsschwerpunkt" number="16313">Gebäude und Infrastruktur</collection>
  </doc>
  <doc>
    <id>4174</id>
    <completedYear/>
    <publishedYear>2018</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>8</pageNumber>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName>Curran Associates Inc</publisherName>
    <publisherPlace>Red Hook, NY</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Optimizing Monitoring - Implementation of Draft Guideline and Case Study of Roof Exposed to Snow Loads</title>
    <abstract language="eng">This contribution addresses the optimisation of monitoring and decision-making criteria regarding the future use of structures and the related implementation in modern guidelines. A summary of the state-of-practice reveals deficiencies that are addressed by prospective guidance for the anticipated updates of standards, providing a general methodology to obtain cost-optimal decisions using limit state design, probabilistic reliability analysis and cost estimates. The implementation of a draft guideline and the corresponding risk-based approach are illustrated in a full-scale case study dealing with the roof of a stadium located in Northern Italy. The results demonstrate the potential of using monitoring systems and probabilistic reliability analysis in order to support decisions regarding safety measures such as snow removal, or temporary closure of the stadium.</abstract>
    <parentTitle language="eng">Proceedings of 40th IABSE Symposium : Tomorrow's Megastructures,  Nantes, France, 19-21 September 2018</parentTitle>
    <identifier type="isbn">978-3-85748-161-1</identifier>
    <identifier type="doi">10.2749/nantes.2018.s27-27</identifier>
    <enrichment key="opus.import.date">2022-06-08T12:38:13+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Dimitris Diamantidis</author>
    <author>Miroslav Sýkora</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>cost optimisation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>decision making criteria</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Eurocodes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>monitoring</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>reliability analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>snow load</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>stadium roof</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>standard</value>
    </subject>
    <collection role="institutes" number="FakBau">Fakultät Bauingenieurwesen</collection>
    <collection role="othforschungsschwerpunkt" number="16313">Gebäude und Infrastruktur</collection>
  </doc>
  <doc>
    <id>2853</id>
    <completedYear/>
    <publishedYear>2019</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>35</pageFirst>
    <pageLast>40</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>19</volume>
    <type>conferenceobject</type>
    <publisherName>TECHNICAL UNIVERSITY OF OSTRAVA</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Implementing Snow Load Monitoring to control Reliability of a Stadium Roof</title>
    <abstract language="eng">This contribution shows how monitoring can be used to control reliability of a structure not complying with the requirements of Eurocodes. A general methodology to obtain cost-optimal decisions using limit state design, probabilistic reliability analysis and cost estimates is utilised in a full-scale case study dealing with the roof of a stadium located in Northern Italy. The results demonstrate the potential of monitoring systems and probabilistic reliability analysis to support decisions regarding safety measures such as snow removal, or temporary closure of the stadium.</abstract>
    <parentTitle language="eng">Transactions of VSB</parentTitle>
    <identifier type="doi">10.35181/tces-2019-0006</identifier>
    <enrichment key="opus.import.date">2022-02-10T06:11:52+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Dimitris Diamantidis</author>
    <author>Miroslav Sýkora</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cost optimisation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>decision making criteria</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Eurocodes</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>monitoring</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>reliability analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>snow load</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>stadium roof, standard</value>
    </subject>
    <collection role="institutes" number="FakBau">Fakultät Bauingenieurwesen</collection>
    <collection role="othforschungsschwerpunkt" number="16313">Gebäude und Infrastruktur</collection>
  </doc>