    <title language="eng">Generation and Distribution of Surgical Smoke During High Frequency Electrocauterization</title>
    <abstract language="eng">Surgical Smoke is generated during the cauterization of tissue with high-frequency (HF) devices and consists of 95% water vapor and 5% cellular debris. When the coagulation tweezers, which are supplied with HF voltage by the HF device, touch tissue, the electric circuit is closed, and smoke is generated by the heat. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during coagulation of tissue. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. With higher power of the HF device, the particles generated are larger in size and the total number of particles generated is also higher. Adding artificial saliva to the tissue shows even higher particle counts. The study by laser light sheet also confirms this. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms considering the risk arising from surgical smoke. Furthermore, the experiments will provide the database for further numerical investigations.</abstract>
    <parentTitle language="eng">New Results in Numerical and Experimental Fluid Mechanics XIV. STAB/DGLR Symposium 2022</parentTitle>
    <identifier type="doi">10.1007/978-3-031-40482-5_53</identifier>
    <identifier type="isbn">978-3-031-40481-8</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <enrichment key="OtherSeries">Notes on Numerical Fluid Mechanics and Multidisciplinary Design ; 154</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Vera Stelzer</author>
    <author>Sandra Melina Tauwald</author>
    <author>Veronika Vielsmeier</author>
    <author>Fabian Cieplik</author>
    <author>Arne Kandulski</author>
    <author>Wulf Schneider-Brachert</author>
    <author>Olaf Wünsch</author>
    <author>Markus Rütten</author>
    <author>Lars Krenkel</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Surgical smoke</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluid Mechanics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Aerosols</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tracheotomies</value>
    </subject>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
    <collection role="persons" number="krenkellbfmbeitr">Krenkel, Lars (Prof. Dr.), Beitraege - Labor Biofluidmechanik</collection>
  </doc>
  <doc>
    <id>5793</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferencepresentation</type>
    <publisherName/>
    <publisherPlace>Göttingen</publisherPlace>
    <creatingCorporation>Deutsche Gesellschaft für Luft- und Raumfahrt e.V. / Arbeitsgemeinschaft Strömungen mit Ablösung, AG STAB</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>2023-02-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Generation, Distribution, and Contagiousness of Surgical Smoke during Tracheotomies</title>
    <abstract language="eng">Surgical smoke has been a little discussed topic in the context of the current pandemic. Surgical smoke is generated during the cauterization of tissue with heat-generating devices and consists of 95% water&#13;
vapor and 5% cellular debris in the form of particulate matter. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during tissue electrocautery. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. The higher the power of the high-frequency-device the larger the particles in size and the higher the resulting particle counts. The images taken show the densest smoke at 40W with artificial saliva. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms that the risk arising from surgical smoke should be considered. Furthermore, the experiments will provide the database for further numerical investigations.</abstract>
    <parentTitle language="deu">23. DGLR Fach-Symposium Strömungen mit Ablösung, 09./10. November 2022, Berlin, Deutschland</parentTitle>
    <identifier type="url">https://www.dlr.de/as/Portaldata/5/Resources/dokumente/veranstaltungen/stab_workshop/Jahresbericht2022.pdf</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="BegutachtungStatus">begutachtet</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Vera Stelzer</author>
    <author>Sandra Melina Tauwald</author>
    <author>Veronika Vielsmeier</author>
    <author>Fabian Cieplik</author>
    <author>Arne Kandulski</author>
    <author>Wulf Schneider-Brachert</author>
    <author>Olaf Wuensch</author>
    <author>Markus Rütten</author>
    <author>Lars Krenkel</author>
    <collection role="ddc" number="6">Technik, Medizin, angewandte Wissenschaften</collection>
    <collection role="institutes" number="FAKMB">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="RCBE">Regensburg Center of Biomedical Engineering - RCBE</collection>
    <collection role="institutes" number="RCHST">Regensburg Center of Health Sciences and Technology - RCHST</collection>
    <collection role="persons" number="krenkellbfmconf">Krenkel, Lars (Prof. Dr.), Präsentationen - Labor Biofluidmechanik</collection>
    <collection role="othforschungsschwerpunkt" number="16314">Lebenswissenschaften und Ethik</collection>
    <collection role="institutes" number="">Labor Biofluidmechanik</collection>
  </doc>
</export-example>