    <title language="eng">Influence of Geometrical Arrangements of Si Tip Arrays Fabricated by Laser Micromachining on their Emission Behaviour</title>
    <abstract language="eng">ensely packed emitters on a field emission array lead typically to mutual shielding. Taking biology as a role model for geometric arrangements could be a way to reduce this effect. For comparison, two electron sources, one with a spiral and a second with conventional rectangular (orthogonal) arranged emitters, were fabricated and investigated. Emission currents of 6 µA in the spiral ordered array and 120 µA in the rectangular array were reached with an extraction voltage of 400 V. From a mid-term measurement over 1 h a current stability of ±8.8 % (spiral) respectively ±5.7 % (rectangular) with a mean degradation of -3.0 µA/h (spiral) and -0.12 µA/h (rectangular) could be observed.</abstract>
    <parentTitle language="eng">2021 34th International Vacuum Nanoelectronics Conference (IVNC): 7/5/2021 - 7/9/2021, Lyon, France</parentTitle>
    <identifier type="isbn">978-1-6654-2589-6</identifier>
    <identifier type="doi">10.1109/IVNC52431.2021.9600717</identifier>
    <identifier type="issn">2380-6311</identifier>
    <enrichment key="opus.import.date">2022-02-04T08:58:18+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">importuser</enrichment>
    <enrichment key="BegutachtungStatus">peer-reviewed</enrichment>
    <licence>Keine Lizenz - Es gilt das deutsche Urheberrecht: § 53 UrhG</licence>
    <author>Matthias Hausladen</author>
    <author>Vitali Bomke</author>
    <author>Philipp Buchner</author>
    <author>Michael Bachmann</author>
    <author>Alexandr Knapek</author>
    <author>Rupert Schreiner</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>aperture field</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>emission grid</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fabrication</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>laser micromachining</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>parastichy tip arrangements</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>silicon field emission</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Stability analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Spirals</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Field emitter array</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Voltage measurement</value>
    </subject>
    <collection role="institutes" number="FakANK">Fakultät Angewandte Natur- und Kulturwissenschaften</collection>
    <collection role="persons" number="schreinerlmconf">Schreiner, Rupert (Prof. Dr.), Konferenzbeiträge - Labor für Mikrosensorik</collection>
    <collection role="othforschungsschwerpunkt" number="16317">Sensorik</collection>
    <collection role="institutes" number="">Labor Mikrosensorik</collection>
  </doc>
</export-example>