@article{KoeckStrieglKrausetal., author = {K{\"o}ck, Hannah and Striegl, Birgit and Kraus, Annalena and Zborilova, Magdalena and Christiansen, Silke H. and Sch{\"a}fer, Nicole and Gr{\"a}ssel, Susanne and Hornberger, Helga}, title = {In Vitro Analysis of Human Cartilage Infiltrated by Hydrogels and Hydrogel-Encapsulated Chondrocytes}, series = {Bioengineering}, volume = {10}, journal = {Bioengineering}, publisher = {MDPI}, doi = {10.3390/bioengineering10070767}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-61235}, pages = {1 -- 21}, abstract = {Osteoarthritis (OA) is a degenerative joint disease causing loss of articular cartilage and structural damage in all joint tissues. Given the limited regenerative capacity of articular cartilage, methods to support the native structural properties of articular cartilage are highly anticipated. The aim of this study was to infiltrate zwitterionic monomer solutions into human OA-cartilage explants to replace lost proteoglycans. The study included polymerization and deposition of methacryloyloxyethyl-phosphorylcholine- and a novel sulfobetaine-methacrylate-based monomer solution within ex vivo human OA-cartilage explants and the encapsulation of isolated chondrocytes within hydrogels and the corresponding effects on chondrocyte viability. The results demonstrated that zwitterionic cartilage-hydrogel networks are formed by infiltration. In general, cytotoxic effects of the monomer solutions were observed, as was a time-dependent infiltration behavior into the tissue accompanied by increasing cell death and penetration depth. The successful deposition of zwitterionic hydrogels within OA cartilage identifies the infiltration method as a potential future therapeutic option for the repair/replacement of OA-cartilage extracellular suprastructure. Due to the toxic effects of the monomer solutions, the focus should be on sealing the OA-cartilage surface, instead of complete infiltration. An alternative treatment option for focal cartilage defects could be the usage of monomer solutions, especially the novel generated sulfobetaine-methacrylate-based monomer solution, as bionic for cell-based 3D bioprintable hydrogels.}, language = {en} } @article{HornbergerKisselStriegletal., author = {Hornberger, Helga and Kissel, Hannah and Striegl, Birgit and Kronseder, Matthias and Vollnhals, Florian and Christiansen, Silke H.}, title = {Bioactivity and corrosion behavior of magnesium barrier membranes}, series = {Materials and Corrosion}, volume = {73}, journal = {Materials and Corrosion}, number = {1}, publisher = {Wiley}, doi = {10.1002/maco.202112385}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-24499}, pages = {8 -- 19}, abstract = {In the current research, magnesium and its alloys have been intensively studied as resorbable implant materials. Magnesium materials combine their good mechanical properties with bioactivity, which make them interesting for guided bone regeneration and for the application as barrier membranes. In this study, the in vitro degradation behavior of thin magnesium films was investigated in cell medium and simulated body fluid. Three methods were applied to evaluate corrosion rates: measurements of (i) the gaseous volume evolved during immersion, (ii) volume change after immersion, and (iii) polarization curves. In this comparison, measurements of H2 development in Dulbecco's modified Eagle's medium showed to be the most appropriate method, exhibiting a corrosion rate of 0.5 mm·year-1. Observed oxide and carbon contamination have a high impact on controlled degradation, suggesting that surface treatment of thin foils is necessary. The bioactivity test showed positive results; more detailed tests in this area are of interest.}, language = {en} } @article{KloiberAnetsbergerSchultheissetal., author = {Kloiber, Jessica and Anetsberger, Viktoria and Schultheiß, Ulrich and Hornberger, Helga}, title = {High quality surfaces of magnesium alloy AZ31 by adjusting appropriate electropolishing parameters}, series = {Electrochimica Acta}, volume = {513}, journal = {Electrochimica Acta}, publisher = {Elsevier}, doi = {10.1016/j.electacta.2024.145547}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-79298}, language = {en} } @article{KloiberSchultheissHornberger, author = {Kloiber, Jessica and Schultheiß, Ulrich and Hornberger, Helga}, title = {Impact of heat treatment on the surface quality of electropolished WE43 alloy}, series = {Materials Letters}, volume = {397}, journal = {Materials Letters}, publisher = {Elsevier BV}, issn = {0167-577X}, doi = {10.1016/j.matlet.2025.138821}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-83512}, pages = {5}, abstract = {In this study, the Mg alloy WE43 was solution annealed and precipitation hardened prior to electropolishing to evaluate the effects of different microstructures on the electropolishing result. While coarsely distributed precipitates led to surfaces showing wavy structures and dents after electropolishing, a uniform microstructure resulted in an even finish of the surface. The homogenization and refinement of the microstructure by heat treatment is a method to ensure improved electropolished surfaces of Mg materials}, language = {en} } @article{KloiberSchultheissSoteloetal., author = {Kloiber, Jessica and Schultheiß, Ulrich and Sotelo, Lamborghini and Sarau, George and Christiansen, Silke H. and Gavras, Sarkis and Hort, Norbert and Hornberger, Helga}, title = {Corrosion behaviour of electropolished magnesium materials}, series = {Materials Today Communications}, journal = {Materials Today Communications}, edition = {Journal Pre-proof}, publisher = {Elsevier}, doi = {10.1016/j.mtcomm.2023.107983}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-68254}, abstract = {Although magnesium and its alloys are promising candidates as biodegradable implant materials, the tendency for localized corrosion mechanism in physiological environment limit their biomedical application. Electropolishing is an attractive strategy for improving the corrosion behaviour of metals, but it is still largely unexplored in magnesium materials. In this study, the characterization of electropolished surfaces of AM50 and pure magnesium was performed, focussing on their in vitro degradation behaviour in cell medium. Corrosion rates were evaluated using potentiodynamic polarisation. The surface morphology before and after the onset of corrosion was investigated by scanning electron microscopy and confocal laser scanning microscopy. The presented electropolishing process led to improved surface performances, observable by significantly lower corrosion rates (0.08 mm·year-1 in Dulbecco's modified Eagle's medium), lower arithmetical mean height (0.05 µm), lower water contact angle (25-35°) and lower micro hardness (35-50 HV 0.1) compared to mechanically and chemically treated surfaces. MgO/Mg(OH)2 could be detected on electropolished surfaces. The localized corrosion mode could be reduced, but not entirely prevented. Electropolishing shows great potential as post-treatment of magnesium-based components, but detailed tests of the long-term corrosion behaviour are an important area of future research.}, language = {en} }