@article{WeiglFeldmeierBierletal., author = {Weigl, Stefan and Feldmeier, Florian and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Photoacoustic detection of acetone in N2 and synthetic air using a high power UV LED}, series = {Sensors Actuators B Chemical}, volume = {316}, journal = {Sensors Actuators B Chemical}, number = {August}, publisher = {Elsevier}, doi = {10.1016/j.snb.2020.128109}, pages = {1 -- 11}, abstract = {The performance of a photoacoustic trace gas sensor for the detection of acetone in N2 and synthetic air is reported. The sensor system utilises an amplitude modulated UV LED. The light source has an emission maximum at 278 nm and a maximum CW output power of 300 mW according to the datasheet. Three different collimating and focusing approaches have been investigated to guide the highly divergent LED light into the acoustic resonator of the photoacoustic measurement cell. A 3D printed aluminium cell was designed to optimize light coupling by simultaneously minimizing the photoacoustic background signal generation. Hence, the diameter of the resonator was set to a comparable large diameter of 10 mm and the inner walls of the resonator were mirror polished. The additive manufacturing procedure allowed for integration of a spirally formed gas channel, enabling gas heating prior to detection. The sensor performance was investigated by measuring acetone in N2 and synthetic air at different concentrations. The UV LED current was set to 86 \% of the maximum value according to the datasheet of the light source in order to increase the lifetime and thermal stability. An Allan-Werle deviation analysis validates a stable sensor performance. The limit of detection (LoD) was determined at a 3σ noise level with a 10 s lock-in amplifier time constant by sampling data points over 20 s with a data acquisition rate of 5 Hz. LoDs of 80.8 ppbV and 19.6 ppbV were obtained for acetone in N2 and synthetic air, respectively.}, language = {en} } @article{WeiglWittmannRuecketal., author = {Weigl, Stefan and Wittmann, Elisabeth and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Effects of ambient parameters and cross-sensitivities from O2, CO2 and H2O on the photoacoustic detection of acetone in the UV region}, series = {Sensors Actuators B Chemical}, journal = {Sensors Actuators B Chemical}, number = {328}, publisher = {Elsevier}, issn = {0925-4005}, doi = {10.1016/j.snb.2020.129001}, abstract = {We present a sensitive UV LED photoacoustic setup for the detection of gaseous acetone and discuss its applicability towards breath analysis. We investigated the performance of the sensor for low acetone concentrations down to 0.1 parts per million (ppmV). The influences of temperature, flow, pressure, optical power and LED duty cycle on the measured signal have been examined. To gain a better understanding of the different effects on the photoacoustic signal, correlation analysis was applied and feature importance was determined using a large measured dataset. Furthermore, the cross-sensitivities towards O2, CO2 and H2O have been studied extensively. Finally, the sensor's performance to detect acetone between 0.1-1 ppmV within gas mixtures simulating breath exhale conditions has been investigated, too. With a limit of detection (LoD) of 12.5 parts per billion (ppbV) (3σ) measured under typical breath exhale gas mixture conditions, the sensor demonstrated a high potential for the application of acetone detection in human breath analysis.}, language = {en} }