@article{PangerlSukulRuecketal., author = {Pangerl, Jonas and Sukul, Pritam and R{\"u}ck, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone}, series = {Photoacoustics}, volume = {38}, journal = {Photoacoustics}, publisher = {Elsevier}, issn = {2213-5979}, doi = {10.1016/j.pacs.2024.100604}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-71279}, pages = {12}, abstract = {n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.}, language = {en} } @article{EscherRueckJobstetal., author = {Escher, Lukas and R{\"u}ck, Thomas and Jobst, Simon and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Photodissociation-Driven Photoacoustic Spectroscopy with UV-LEDs for Ozone Detection}, series = {Photoacoustics}, volume = {43}, journal = {Photoacoustics}, publisher = {Elsevier BV}, issn = {2213-5979}, doi = {10.1016/j.pacs.2025.100718}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-80076}, pages = {16}, abstract = {This study presents the development and evaluation of a UV-LED based photoacoustic (PA) measurement system for ozone (O3) detection to demonstrate its potential for low-cost and accurate sensing while for the first time addressing the importance of photodissociation for PA signal generation for O3 in the UV range. With a detection limit of 7.9 ppbV, the system exhibits a significant advancement over state-of-the-art UV-PA O3 detection and is on par with laser-based setups. Following a novel discussion of the PA signal arising from photodissociation and its products, cross-sensitivity effects due to environmental factors such as temperature and gas composition were systematically analyzed. A digital twin driven compensation for these influences was implemented and evaluated. Despite the challenges associated with modeling the effects of H2O and CO2, the PA system shows considerable potential, though further studies in real world applications must be conducted.}, language = {en} } @article{HauslerHolznerEhrnspergeretal., author = {Hausler, Peter and Holzner, Lukas and Ehrnsperger, Matthias and Bierl, Rudolf}, title = {Evaluation of the creep strength of samples produced by fused deposition modeling}, series = {Open Engineering}, volume = {14}, journal = {Open Engineering}, number = {1}, publisher = {de Gruyter}, doi = {10.1515/eng-2024-0084}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-79760}, pages = {10}, abstract = {Data sheets for 3D printing materials typically include softening temperature, impact strength, tensile strength, and stiffness. However, creep strength, an important parameter for components used over an extended period, is usually not included. Nevertheless, this parameter is of significant importance for components that are used over an extended period of time.This study compares the long-term creep behavior of a selection of materials that are commonly used in fused deposition modeling 3D printing. The materials under investigation are acrylonitrile butadiene styrene, acrylonitrile styrene acrylate, polylactic acid, and polycarbonate. In addition, the influence of fiber reinforcements on these materials is also examined. A simple, reproducible test procedure is proposed for users to determine and compare creep resistance of materials. This enables developers to select materials suitable for their own requirements on creep resistance and allows 3D-printing users to compare different materials. Results suggest that fiber reinforcement generally improves creep stability in 3D-printing materials, with GreenTEC Pro Carbon and add:north PC Blend HT LCF showing the most promise in this study.}, language = {en} } @article{SchelsEdlerHerdletal., author = {Schels, Andreas and Edler, Simon and Herdl, Florian and Hansch, Walter and Bachmann, Michael and Ritter, Daniela and Dudeck, Markus and Duesberg, Felix and Meyer, Manuel and Pahlke, Andreas and Hausladen, Matthias and Buchner, Philipp and Schreiner, Rupert}, title = {In situ quantitative field emission imaging using a low-cost CMOS imaging sensor}, series = {Journal of Vacuum Science \& Technology B}, volume = {40}, journal = {Journal of Vacuum Science \& Technology B}, number = {1}, publisher = {AIP Publishing}, doi = {10.1116/6.0001551}, abstract = {Spatially resolved field emission measurements represent an important factor in further development of existing field emitter concepts. In this work, we present a novel approach that allows quantitative analysis of individual emission spots from integral current-voltage measurements using a low-cost and commercially available CMOS camera. By combining different exposure times to extrapolate oversaturated and underexposed pixels, a near congruence of integral current and image brightness is shown. The extrapolation also allows parallel investigation of all individual tips participating in the total current with currents ranging from a few nanoampere to one microampere per tip. The sensitivity, which is determined by the integral brightness-to-current ratio, remains unchanged within the measurement accuracy even after ten full measurement cycles. Using a point detection algorithm, the proportional current load of each individual tip of the field emitter array is analyzed and compared at different times during the initial measurement cycle. Together with the extracted I-V curves of single emission spots from the integral measurement, the results indicate the effect of premature burnout of particularly sharp tips during conditioning of the emitter.}, language = {en} } @article{EngelhardtMelznerHavelkovaetal., author = {Engelhardt, Lucas and Melzner, Maximilian and Havelkova, Linda and Fiala, Pavel and Christen, Patrik and Dendorfer, Sebastian and Simon, Ulrich}, title = {A new musculoskeletal AnyBodyTM detailed hand model}, series = {Computer Methods in Biomechanics and Biomedical Engineering}, volume = {24}, journal = {Computer Methods in Biomechanics and Biomedical Engineering}, number = {7}, publisher = {Taylor \& Francis}, doi = {10.1080/10255842.2020.1851367}, pages = {777 -- 787}, abstract = {Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop, implement, and validate a fully detailed hand model using the AnyBody Modelling System (AMS) (AnyBody, Aalborg, Denmark). To achieve this, a consistent multiple cadaver dataset, including all extrinsic and intrinsic muscles, served as a basis. Various obstacle methods were implemented to obtain with the correct alignment of the muscle paths together with the full range of motion of the fingers. These included tori, cylinders, and spherical ellipsoids. The origin points of the lumbrical muscles within the tendon of the flexor digitorum profundus added a unique feature to the model. Furthermore, the possibility of an entire patient-specific scaling based on the hand length and width were implemented in the model. For model validation, experimental datasets from the literature were used, which included the comparison of numerically calculated moment arms of the wrist, thumb, and index finger muscles. In general, the results displayed good comparability of the model and experimental data. However, the extrinsic muscles showed higher accordance than the intrinsic ones. Nevertheless, the results showed, that the proposed developed inverse dynamics hand model offers opportunities in a broad field of applications, where the muscles and joint forces of the forearm play a crucial role.}, language = {en} } @inproceedings{TschurtschenthalerKrenkelSchreiner, author = {Tschurtschenthaler, Karl and Krenkel, Lars and Schreiner, Rupert}, title = {Mechano-optical micro pillar sensor for biofluidmechanic wall shear stress measurements}, series = {25th Congress of the European Society of Biomechanics (ESB), July 7-10, 2019, Vienna, Austria}, booktitle = {25th Congress of the European Society of Biomechanics (ESB), July 7-10, 2019, Vienna, Austria}, language = {en} } @incollection{Weber, author = {Weber, Karsten}, title = {Alternative Benutzerschnittstellen als M{\"o}glichkeit der Kompensation sensorischer Handicaps}, series = {Barrierefreie Informationssysteme: Zug{\"a}nglichkeit f{\"u}r Menschen mit Behinderung in Theorie und Praxis}, booktitle = {Barrierefreie Informationssysteme: Zug{\"a}nglichkeit f{\"u}r Menschen mit Behinderung in Theorie und Praxis}, editor = {Kerkelmann, Friederike and Lewandowski, Dirk}, publisher = {de Gruyter}, address = {Berlin}, doi = {10.1515/9783110337297-004}, pages = {49 -- 70}, language = {de} } @inproceedings{PrommesbergerLangerSchreiner, author = {Prommesberger, Christian and Langer, Christoph and Schreiner, Rupert}, title = {Stable and low noise field emission from single p-type Si-tips}, series = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, booktitle = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, publisher = {IEEE}, doi = {10.1109/IVNC.2018.8520018}, pages = {1-2}, abstract = {Single gated p-type Si-tips with two different tip radii were fabricated. An emission current of 2.40 μA was measured for the sharp-edged tip at a voltage of 170 V. In contrast, a stable and reproducible emission behavior was observed with an increased tip radius resulting in a pronounced saturation region between 90 V and 150 V, but merely an emission current of 0.55 μA at 150 V. More remarkable is the stable emission behavior with fluctuation of ± 4 \% during a measurement period of 30 minutes. The integral emission current in a homogeneous tip array (16 emitters) showed nearly the same I-V characteristics compared to the single tip and is therefore, most dominated by only a stable single tip in the array.}, language = {en} } @inproceedings{LindnerBerndtPrommesbergeretal., author = {Lindner, Matthias and Berndt, Dominik and Prommesberger, Christian and Langer, Christoph and Schreiner, Rupert}, title = {Field emission assisted micro plasma discharges at vacuum and atmospheric pressures}, series = {31st International Vacuum Nanoelectronics Conference (IVNC), 2018, Kyoto, Japan}, booktitle = {31st International Vacuum Nanoelectronics Conference (IVNC), 2018, Kyoto, Japan}, doi = {10.1109/IVNC.2018.8520181}, pages = {2}, abstract = {Spatially confined non-equilibrium plasmas at vacuum and atmospheric pressure in the dimensions from a few microns to one millimeter are a promising approach to the generation and maintenance of stable glow discharges. The realization of these micro-discharges or micro-plasmas enable more accurate investigations in the field of micro plasma research. We report on field emission assisted micro plasmas excited by an alternating current with frequencies up to 1 kHz. Due to the field enhancement caused by an array of Si nano-tip structures the ignition voltage of stable plasma discharges can be reduced by 30\%.}, language = {en} } @inproceedings{BerndtLindnerTschurtschenthaleretal., author = {Berndt, Dominik and Lindner, Matthias and Tschurtschenthaler, Karl and Langer, Christoph and Schreiner, Rupert}, title = {Miniaturized Plasma Actuator Flow Measurements by MEMS-Based Thermal Conductivity Sensors}, series = {MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz}, volume = {Vol.13}, booktitle = {MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz}, number = {2}, doi = {10.3390/proceedings2130939}, abstract = {The gasflow created by a minaturized dielectric barrier discharge (DBD) plasma actuator is measured by a MEMS-based thermal conductivity gas sensor giving an indication of flow velocity and flow direction. The possiblity of several sensors in a small area gives a far better accuracy of local flow phenomena compared to conventional sensors. This is important for a better understanding of plasma- induced flow characteristics.}, language = {en} } @inproceedings{SteindlMottokMeieretal., author = {Steindl, Michael and Mottok, J{\"u}rgen and Meier, Hans and Schiller, Frank and Fr{\"u}chtl, M.}, title = {Safeguarded Processing of Sensor Data}, series = {IT-SecurityArea (IT-SA 2009) vom 13.-15. Oktober 2009, N{\"u}rnberg}, booktitle = {IT-SecurityArea (IT-SA 2009) vom 13.-15. Oktober 2009, N{\"u}rnberg}, pages = {8}, abstract = {The spectrum of software tasks no longer includes only rare function controlling tasks for sensor actuator chains in reactive embedded systems. However, more and more responsible challenges like safety-critical scenarios are tackled. Therefore sensor data have to be safeguarded by several mechanism. An obvious and widely used approach is the use of two redundant hardware controllers, but this comes along with an additional cost, space and energy factor. Another way to fulfill certain safety properties is to implement a second diverse software channel in a single micro-controller architecture according the Safely Embedded Software (SES) approach. However, a lack of performance occurs by implementing this diverse channel for complex computations e.g. floating-point operations. This paper gives an approach for transferring the SES into a coprocessor and to migrate SES to a flexible and powerful FPGA architecture.}, language = {en} } @inproceedings{SteindlMottokMeieretal., author = {Steindl, Michael and Mottok, J{\"u}rgen and Meier, Hans and Schiller, Frank and Fr{\"u}chtl, M.}, title = {Safeguarded Processing of Sensor Data}, series = {5th Embedded Real Time Software and Systems Conference (ERTS2 2010), May 2010, Toulouse, France}, booktitle = {5th Embedded Real Time Software and Systems Conference (ERTS2 2010), May 2010, Toulouse, France}, language = {en} } @inproceedings{EdlerHanschPrommesbergeretal., author = {Edler, Simon and Hansch, Walter and Prommesberger, Christian and Schreiner, Rupert}, title = {Influence of adsorbates on the performance of a field emitter array in a high voltage triode setup}, series = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, booktitle = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, publisher = {IEEE}, doi = {10.1109/IVNC.2018.8520214}, pages = {1-2}, abstract = {The influence of residual gas pressure on the characteristics of black-Silicon field emitter arrays in a high voltage triode setup is investigated. I-Vcharacteristics at different pressure levels show a decrease of emission current with rising pressure. This can be explained by an increase of the work function and charging of the emitter surface due to adsorbates. The initial characteristics can be restored by heating the FEA up to 110 °C during electron emission. This regeneration procedure enables an extension of the lifetime from about 20 h to 440 h at a residual gas pressure of 10 -5 mbar.}, language = {en} } @inproceedings{KaesbauerSchmailzlPrehmetal., author = {K{\"a}sbauer, Johannes and Schmailzl, Anton and Prehm, Jens and Loose, Tobias and Hierl, Stefan}, title = {Simulation of Quasi-Simultaneous Laser Transmission Welding of Plastics}, series = {Procedia CIRP}, volume = {94}, booktitle = {Procedia CIRP}, publisher = {Elsevier}, doi = {10.1016/j.procir.2020.09.136}, pages = {737 -- 741}, abstract = {Thermo-mechanical simulation offers great opportunities to optimize welding processes of plastics. For realistic simulation, the temperature dependent mechanical properties need to be implemented from ambient temperature to temperatures above the flow temperature. Standard test methods are insufficient for characterization in the entire temperature range because close to the flow temperature the material is too soft for tensile tests and too stiff for rheometry. Therefore, an optimization strategy is developed, that determines unknown material parameters by testing in welding simulations. The unknown parameters are iteratively adjusted to minimize the mismatch between computed and measured set-paths. Thus, important process characteristics are calculated realistically, enabling the computer aided assessment of the weld quality.}, subject = {Kunststoffschweißen}, language = {en} } @article{WeiglFeldmeierBierletal., author = {Weigl, Stefan and Feldmeier, Florian and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Photoacoustic detection of acetone in N2 and synthetic air using a high power UV LED}, series = {Sensors Actuators B Chemical}, volume = {316}, journal = {Sensors Actuators B Chemical}, number = {August}, publisher = {Elsevier}, doi = {10.1016/j.snb.2020.128109}, pages = {1 -- 11}, abstract = {The performance of a photoacoustic trace gas sensor for the detection of acetone in N2 and synthetic air is reported. The sensor system utilises an amplitude modulated UV LED. The light source has an emission maximum at 278 nm and a maximum CW output power of 300 mW according to the datasheet. Three different collimating and focusing approaches have been investigated to guide the highly divergent LED light into the acoustic resonator of the photoacoustic measurement cell. A 3D printed aluminium cell was designed to optimize light coupling by simultaneously minimizing the photoacoustic background signal generation. Hence, the diameter of the resonator was set to a comparable large diameter of 10 mm and the inner walls of the resonator were mirror polished. The additive manufacturing procedure allowed for integration of a spirally formed gas channel, enabling gas heating prior to detection. The sensor performance was investigated by measuring acetone in N2 and synthetic air at different concentrations. The UV LED current was set to 86 \% of the maximum value according to the datasheet of the light source in order to increase the lifetime and thermal stability. An Allan-Werle deviation analysis validates a stable sensor performance. The limit of detection (LoD) was determined at a 3σ noise level with a 10 s lock-in amplifier time constant by sampling data points over 20 s with a data acquisition rate of 5 Hz. LoDs of 80.8 ppbV and 19.6 ppbV were obtained for acetone in N2 and synthetic air, respectively.}, language = {en} } @article{BerndtMuggliWittweretal., author = {Berndt, Dominik and Muggli, Josef and Wittwer, Franz and Langer, Christoph and Heinrich, Stephan and Knittel, Thorsten and Schreiner, Rupert}, title = {MEMS-based thermal conductivity sensor for hydrogen gas detection in automotive applications}, series = {Sensors and Actuators A: Physical}, volume = {305}, journal = {Sensors and Actuators A: Physical}, number = {April}, publisher = {Elsevier}, doi = {10.1016/j.sna.2019.111670}, abstract = {Accurate detection of hydrogen gas in vehicle interiors is very important for the future of a fuel cell car. Since this type of gas is highly volatile and flammable, the measurement methods have to be very reliable and precise due to safety reasons. In this paper a thermal conductivity sensor for hydrogen gas detection is presented, exhibiting a lower detection limit of 2000 ppm hydrogen in laboratory air. The sensor element is realized by micro-fabrication techniques on silicon wafers. The heated filament is exposed by a selective wet etching process creating a micro-hotplate on a thin membrane. In order to minimize power consumption, the sensor is operated in pulsed mode. Hydrogen gas detection was carried out using a synthetic gas testbench. Measurements of hydrogen contents ranging from 0\% to 4\% with an increment of 0.5\% were successfully performed for ambient gas temperatures between -15°C and 84°C. Including humidity, high moisture contents have the greatest influence on thermal conductivity. This was predicted in theoretical investigations and confirmed in experiments. For evaluation, both the change in resistance ΔR as well as the time constant τ were taken as sensor output. For both quantities, the previously established theoretical relationship with thermal conductivity could be confirmed.}, language = {en} }