@inproceedings{PutzerWeberDendorfer, author = {Putzer, Michael and Weber, Tim and Dendorfer, Sebastian}, title = {Design studies on hip prosthesis using patient specific data}, series = {Simpleware Users meeting, November 9th 2011, Bristol, UK}, booktitle = {Simpleware Users meeting, November 9th 2011, Bristol, UK}, language = {en} } @inproceedings{RasmussenBichlerChristensenetal., author = {Rasmussen, John and Bichler, R. and Christensen, Soeren Toerholm and Wirix-Speetjens, Roel and Dendorfer, Sebastian and Renkawitz, Tobias}, title = {Subject-specific Musculoskeletal Simulation of Hip Dislocation Risk in Activities of Daily Living}, series = {Proceedings of the 2011 ORS Annual Meeting, Long Beach, CA.}, booktitle = {Proceedings of the 2011 ORS Annual Meeting, Long Beach, CA.}, number = {Paper No. 306}, language = {en} } @article{ReichHornberger, author = {Reich, Sven and Hornberger, Helga}, title = {The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns}, series = {Journal of Prosthetic Dentistry}, volume = {88}, journal = {Journal of Prosthetic Dentistry}, number = {1}, pages = {44 -- 49}, abstract = {Statement of problems: Computer-aided design/computer-assisted machining systems offer the possibility of fabricating restorations from one machinable ceramic block. Whether multishaded blocks improve esthetic results and are a viable alternative to individually stained ceramics has not been fully determined. Purpose: The aim of this investigation was to examine the effect of multishaded blocks on the esthetic appearance of all-ceramic CEREC crowns and compare these crowns with single-shade and stained restorations. Material and methods: Ten subjects were included in this study. For each subject, 6 different crowns were milled with the use of a CEREC machine. One crown was milled from each of the following machinable ceramic materials: CEREC Vitablocs Mark II in classic colors; Vitablocs Mark II in 3D-Master colors; Vitablocs Mark II in either classic or 3D-Master colors, with additional staining; Megadenta Bloxx multishaded; Mark II experimental multilayer; and an experimental multilayer leucite ceramic. Three independent examiners assessed the esthetic appearance of crowns fabricated to match each subject's anterior tooth shade. A scale of 1 to 6 was used to score the shade match and esthetic adaptation of each crown, with 1 representing excellent characteristics and 3.5 serving as the threshold for clinical acceptability. The examiners' scores were averaged, and the mean values were analyzed with the Wilcoxon signed rank test (P 87\% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups.}, subject = {H{\"u}ftgelenkprothese}, language = {en} } @article{RenkawitzWeberDullienetal., author = {Renkawitz, Tobias and Weber, Tim A. and Dullien, Silvia and Woerner, Michael and Dendorfer, Sebastian and Grifka, Joachim and Weber, Markus}, title = {Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics}, series = {Gait \& Posture}, volume = {vol. 49}, journal = {Gait \& Posture}, doi = {10.1016/j.gaitpost.2016.07.011}, pages = {196 -- 201}, abstract = {We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p < 0.001), normalized walking speed (p < 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register.}, language = {en} } @inproceedings{RobieDendorferRasmussenetal., author = {Robie, Bruce and Dendorfer, Sebastian and Rasmussen, John and Christensen, Soeren Toerholm}, title = {Axial Rotation Requires Greatest Load in Multifidus Muscle - Potential Association with Low Back Pain?}, series = {Annual Meeting of the AANS/CNS Section on Disorders of the Spine and Peripheral Nerves, 2011, Phoenix, Arizona}, booktitle = {Annual Meeting of the AANS/CNS Section on Disorders of the Spine and Peripheral Nerves, 2011, Phoenix, Arizona}, language = {en} } @inproceedings{RobieRasmussenChristensenetal., author = {Robie, Bruce and Rasmussen, John and Christensen, Soeren Toerholm and Dendorfer, Sebastian}, title = {Herniation Induces 55\% Increase in Load of Key Stabilizing Muscle - Impact on Herniation Treatment Devices?}, series = {Spine Arthoplasty Society Meeting, New Orleans, 2010}, booktitle = {Spine Arthoplasty Society Meeting, New Orleans, 2010}, language = {en} } @article{RoldanMoralisDendorferetal., author = {Rold{\´a}n, J.C. and Moralis, A. and Dendorfer, Sebastian and Witte, J. and Reicheneder, C.}, title = {Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage}, series = {The Journal of craniofacial surgery}, volume = {22}, journal = {The Journal of craniofacial surgery}, number = {6}, doi = {10.1097/SCS.0b013e318231fc8d}, pages = {2384 -- 2386}, abstract = {A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry.}, subject = {Mund-Kiefer-Gesichts-Chirurgie}, language = {en} } @misc{SaffertMelznerDendorfer, author = {Saffert, Anne-Sophia and Melzner, Maximilian and Dendorfer, Sebastian}, title = {Biomechanical Analysis of the Right Elevated Glenohumeral Joint in Violinists during Legato-Playing}, series = {Biomdlore 2021: 21-23 October 2021 Vilnius/Trakai, Lithuania}, journal = {Biomdlore 2021: 21-23 October 2021 Vilnius/Trakai, Lithuania}, doi = {10.3233/THC-219001}, abstract = {BACKGROUND: Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements. OBJECTIVE: For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture. METHODS: Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position. RESULTS: The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture. CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem.}, language = {en} } @article{SaffertMelznerDendorfer, author = {Saffert, Anne-Sophie and Melzner, Maximilian and Dendorfer, Sebastian}, title = {Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing}, series = {Technology and Health Care}, volume = {30}, journal = {Technology and Health Care}, number = {1}, publisher = {IOS Press}, doi = {10.3233/THC-219001}, pages = {177 -- 186}, abstract = {BACKGROUND: Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements. OBJECTIVE: For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture. METHODS: Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position. RESULTS: The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture. CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem.}, subject = {Biomechanische Analyse}, language = {en} } @inproceedings{SchaefferHerrmannBoehm, author = {Schaeffer, Leon and Herrmann, David and B{\"o}hm, Valter}, title = {Concept of a wrist Hand Orthosis based on a prestressed compliant structure}, series = {Proceedings of the 7th International Conference on Biomedical Engineering and Applications (ICBEA), Hangzhou, China, 21-23 April 2023}, booktitle = {Proceedings of the 7th International Conference on Biomedical Engineering and Applications (ICBEA), Hangzhou, China, 21-23 April 2023}, publisher = {IEEE}, doi = {10.1109/ICBEA58866.2023.00024}, pages = {98 -- 103}, abstract = {In the treatment of hand injuries in the context of orthopedic care, movable wrist hand orthoses are used in numerous instances. Early motion therapy is in most cases advantageous for adequate, rapid and successful long-term healing of the hand. Conventional dynamic wrist hand orthoses can only be used for movement therapy to a limited extent since they represent the wrist as a simple rotating joint and neglect the complexity of the hand movement possibilities. In this paper, a preliminary concept for dynamic wrist hand orthoses based on prestressed compliant structures is presented. The distinctive feature of this concept lies in the enabling of multiaxial motion capabilities of the human hand without applying conventional joints. According to the concept the wrist region is surrounded by a prestressed compliant structure. Besides the derivation and description of the concept, a first three-dimensional computer-aided design is shown. Additionally, the necessary steps in the development of such a novel dynamic wrist orthosis are discussed.}, language = {en} } @inproceedings{SchaefferHerrmannBoehm, author = {Schaeffer, Leon and Herrmann, David and B{\"o}hm, Valter}, title = {Preliminary theoretical considerations of a hand orthosis based on a prestressed, compliant structure}, series = {Proceedings of the 2023 International Symposium on Medical Robotics (ISMR), Atlanta, 19-21 April 2023}, booktitle = {Proceedings of the 2023 International Symposium on Medical Robotics (ISMR), Atlanta, 19-21 April 2023}, publisher = {IEEE}, doi = {10.1109/ISMR57123.2023.10130230}, pages = {1 -- 7}, abstract = {In the treatment of hand injuries in the context of orthopedic care, movable hand orthoses are used in many cases. Early motion therapy is in most cases advantageous for adequate, rapid, and successful long-term healing of the hand. Conventional mobile hand orthoses can only be used for movement therapy to a limited extent since they represent the wrist as a simple rotating joint and neglect the complexity of the movement possibilities of the hand. In this paper, a novel concept for movable hand orthoses based on prestressed compliant structures is presented. The advantage with this concept is that it replicates the multiaxial motion capabilities without the need for conventional joints. Besides the derivation and description of the concept, a first three-dimensional CAD design is shown. Additionally, the next planned steps in the development of such a novel dynamic hand orthosis are described.}, language = {en} } @inproceedings{SchaefferHerrmannBoehm, author = {Schaeffer, Leon and Herrmann, David and B{\"o}hm, Valter}, title = {Theoretical considerations on a 2D compliant tensegrity joint in context of a biomedical application}, series = {Engineering for a changing world : 60th ISC, Ilmenau Scientific Colloquium, Technische Universit{\"a}t Ilmenau, September 4-8, 2023}, booktitle = {Engineering for a changing world : 60th ISC, Ilmenau Scientific Colloquium, Technische Universit{\"a}t Ilmenau, September 4-8, 2023}, publisher = {Technische Universit{\"a}t Ilmenau}, address = {Ilmenau}, doi = {10.22032/dbt.58879}, pages = {1 -- 15}, abstract = {In this paper, a two-dimensional compliant tensegrity joint was investigated for potential biomedical applications such as orthotics or exoskeletons. The structure consists of two compressed members connected by five compliant tensioned members. The concept is based on the tensegrity principle, which allows the realization of dynamic orthoses without conventional hinge joints. Another advantage is the adaptability to the individual needs of the patient through a suitable design of the structure and the careful selection of the characteristics of the elements. Using geometric nonlinear analysis, the mechanical behavior of the structure was investigated, focusing on mechanical compliance. The main objective was to determine the influence of the initial length and stiffness of the tensioned members and the influence of the magnitude of external forces on the overall stiffness of the movable member of the structure. The results highlight the significant impact of member parameters on the structure's stiffness and movability under varying load magnitudes. The research laid the foundation for future development of dynamic orthoses based on this structure.}, language = {en} } @inproceedings{SchaefferHerrmannBoehm, author = {Schaeffer, Leon and Herrmann, David and B{\"o}hm, Valter}, title = {Voruntersuchung einer vorgespannten nachgiebigen Struktur f{\"u}r den Einsatz in dynamischen Handorthesen}, series = {9. IFToMM D-A-CH Konferenz, 16./17. M{\"a}rz 2023, Universit{\"a}t Basel}, booktitle = {9. IFToMM D-A-CH Konferenz, 16./17. M{\"a}rz 2023, Universit{\"a}t Basel}, publisher = {DuEPublico}, address = {Duisburg-Essen}, doi = {10.17185/duepublico/77392}, url = {http://nbn-resolving.de/urn:nbn:de:hbz:465-20230314-153711-8}, abstract = {In diesem Beitrag erfolgt die theoretische Untersuchung einer zweidimensionalen nachgiebigen Tensegrity-Struktur in Hinsicht auf ihre potenzielle Eignung als Basisstruktur f{\"u}r eine dynamische Handorthese. Translatorische und rotatorische relative Bewegungsm{\"o}glichkeiten zwischen den Drucksegmenten der Struktur sind m{\"o}glich, da diese Segmente durch nachgiebige Zugsegmente miteinander verbunden sind. Die Form der Struktur und ihre Vorspannung in einer statisch stabilen Gleichgewichtskonfiguration werden mit Hilfe der Minimierung des Kr{\"a}fte- und Momentenungleichgewichts, der Betrachtung der potentiellen Energie der Struktur und einem Ansatz mittels statischer Finite-Elemente-Methode (FEM) in Abh{\"a}ngigkeit der Segmentparameter untersucht.}, language = {de} } @inproceedings{SchaefferHerrmannBoehm, author = {Schaeffer, Leon and Herrmann, David and B{\"o}hm, Valter}, title = {Preliminary considerations on the form-finding of a tensegrity joint to be used in dynamic orthoses}, series = {8th International Conference on Biomedical Engineering and Applications (ICBEA 2024), Tokio, 18-21. March 2024}, booktitle = {8th International Conference on Biomedical Engineering and Applications (ICBEA 2024), Tokio, 18-21. March 2024}, edition = {accepted paper}, publisher = {ACM}, language = {en} } @article{SchaefferHerrmannSchratzenstalleretal., author = {Schaeffer, Leon and Herrmann, David and Schratzenstaller, Thomas and Dendorfer, Sebastian and B{\"o}hm, Valter}, title = {Preliminary theoretical considerations on the stiffness characteristics of a tensegrity joint for the use in dynamic orthoses}, series = {Journal of Medical Robotics Research}, journal = {Journal of Medical Robotics Research}, publisher = {World Scientific}, doi = {10.1142/S2424905X23400081}, abstract = {Early motion therapy plays an important role for effective long-term healing of joint injuries. In many cases, conventional dynamic orthoses fail to address the intricate movement possibilities of the underlying joints, limited by their simplistic joint representations, often represented by revolute joints, enabling rotations by only one axis. In this paper, a two-dimensional compliant tensegrity joint for use in biomedical applications is investigated. It consists of two compressed members and five compliant tensioned members. Relative movement possibilities are realized by the intrinsic compliance of the structure. In the development of these systems, the first step is the determination of the static stable equilibrium. This analysis is conducted in this paper by considering the potential energy approach or by using the geometric nonlinear finite element method. The mechanical behavior of the structure is assessed with a specific emphasis on its mechanical compliance. The primary objective of this study is the investigation of the influence of structural parameters on the overall stiffness and movability of the structure. The results underscore the significant effect of member parameters on the stiffness and movability of the compliant tensegrity joint, particularly under varying load magnitudes. These findings provide insights for optimizing the joint's performance, contributing to its potential application in advanced orthotic and exoskeleton devices.}, language = {en} } @article{SchecklmannSchmausserKlingeretal., author = {Schecklmann, Martin and Schmausser, Maximilian and Klinger, Felix and Kreuzer, Peter M. and Krenkel, Lars and Langguth, Berthold}, title = {Resting motor threshold and magnetic field output of the figure-of-8 and the double-cone coil}, series = {scientific reports}, volume = {10}, journal = {scientific reports}, number = {1}, publisher = {Nature}, doi = {10.1038/s41598-020-58034-2}, abstract = {The use of the double-cone (DC) coil in transcranial magnetic stimulation (TMS) is promoted with the notion that the DC coil enables stimulation of deeper brain areas in contrast to conventional figure-of-8 (Fo8) coils. However, systematic comparisons of these two coil types with respect to the spatial distribution of the magnetic field output and also to the induced activity in superficial and deeper brain areas are limited. Resting motor thresholds of the left and right first dorsal interosseous (FDI) and tibialis anterior (TA) were determined with the DC and the Fo8 coil in 17 healthy subjects. Coils were orientated over the corresponding motor area in an angle of 45 degrees for the hand area with the handle pointing in posterior direction and in medio-lateral direction for the leg area. Physical measurements were done with an automatic gantry table using a Gaussmeter. Resting motor threshold was higher for the leg area in contrast to the hand area and for the Fo8 in contrast to the DC coil. Muscle by coil interaction was also significant providing higher differences between leg and hand area for the Fo8 (about 27\%) in contrast to the DC coil (about 15\%). Magnetic field strength was higher for the DC coil in contrast to the Fo8 coil. The DC coil produces a higher magnetic field with higher depth of penetration than the figure of eight coil.}, language = {en} } @article{ScheerKubowitschDendorferetal., author = {Scheer, Clara and Kubowitsch, Simone and Dendorfer, Sebastian and Jansen, Petra}, title = {Happy Enough to Relax? How Positive and Negative Emotions Activate Different Muscular Regions in the Back - an Explorative Study}, series = {Frontiers in Psychology}, volume = {Volume 12}, journal = {Frontiers in Psychology}, number = {May 2021}, publisher = {Frontiers Media}, issn = {1664-1078}, doi = {10.3389/fpsyg.2021.511746}, abstract = {Embodiment theories have proposed a reciprocal relationship between emotional state and bodily reactions. Besides large body postures, recent studies have found emotions to affect rather subtle bodily expressions, such as slumped or upright sitting posture. This study investigated back muscle activity as an indication of an effect of positive and negative emotions on the sitting position. The electromyography (EMG) activity of six back muscles was recorded in 31 healthy subjects during exposure to positive and negative affective pictures. A resting period was used as a control condition. Increased muscle activity patterns in the back were found during the exposure to negative emotional stimuli, which was mainly measured in the lumbar and thorax regions. The positive emotion condition caused no elevated activity. The findings show that negative emotions lead to increased differential muscle activity in the back and thus corroborate those of previous research that emotion affects subtle bodily expressions.}, language = {en} } @article{SchmidtPenzkoferBachmaieretal., author = {Schmidt, Ulf and Penzkofer, Rainer and Bachmaier, Samuel and Augat, Peter}, title = {Implant Material and Design Alter Construct Stiffness in Distal Femur Locking Plate Fixation: A Pilot Study}, series = {Clinical Orthopaedics and Related Research®}, volume = {471}, journal = {Clinical Orthopaedics and Related Research®}, number = {9}, publisher = {The Association of Bone and Joint Surgeons}, doi = {10.1007/s11999-013-2867-0}, pages = {2808 -- 2814}, abstract = {BACKGROUND: Construct stiffness affects healing of bones fixed with locking plates. However, variable construct stiffness reported in the literature may be attributable to differing test configurations and direct comparisons may clarify these differences. QUESTIONS/PURPOSES: We therefore asked whether different distal femur locking plate systems and constructs will lead to different (1) axial and rotational stiffness and (2) fatigue under cyclic loading. METHODS: We investigated four plate systems for distal femur fixation (AxSOS, LCP, PERI-LOC, POLYAX) of differing designs and materials using bone substitutes in a distal femur fracture model (OTA/AO 33-A3). We created six constructs of each of the four plating systems. Stiffness under static and cyclic loading and fatigue under cyclic loading were measured. RESULTS: Mean construct stiffness under axial loading was highest for AxSOS (100.8 N/mm) followed by PERI-LOC (80.8 N/mm) and LCP (62.6 N/mm). POLYAX construct stiffness testing showed the lowest stiffness (51.7 N/mm) with 50\% stiffness of AxSOS construct testing. Mean construct stiffness under torsional loading was similar in the group of AxSOS and PERI-LOC (3.40 Nm/degree versus 3.15 Nm/degree) and in the group of LCP and POLYAX (2.63 Nm/degree versus 2.56 Nm/degree). The fourth load level of > 75,000 cycles was reached by three of six AxSOS, three of six POLYAX, and two of six PERI-LOC constructs. All others including all LCP constructs failed earlier. CONCLUSIONS: Implant design and material of new-generation distal femur locking plate systems leads to a wide range of differences in construct stiffness. CLINICAL RELEVANCE: Assuming construct stiffness affects fracture healing, these data may influence surgical decision-making in choosing an implant system.}, language = {en} } @article{SchmitzNeumannNeumannetal., author = {Schmitz, Paul and Neumann, Christoph Cornelius and Neumann, Carsten and Nerlich, Michael and Dendorfer, Sebastian}, title = {Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting}, series = {Journal of Orthopaedic Surgery and Research}, volume = {13}, journal = {Journal of Orthopaedic Surgery and Research}, number = {108}, publisher = {Springer Nature}, doi = {10.1186/s13018-018-0822-1}, pages = {1 -- 8}, abstract = {Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture.}, subject = {Beckenkammknochen}, language = {en} } @inproceedings{SeefriedAurbachWyssetal., author = {Seefried, C. and Aurbach, Maximilian and Wyss, C. and Dendorfer, Sebastian}, title = {Achilles tendon lengthening alters stresses in the growth plate}, series = {International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland}, booktitle = {International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland}, language = {en} } @article{SellmerStanglBeyeretal., author = {Sellmer, Andreas and Stangl, Hubert and Beyer, Mandy and Gr{\"u}nstein, Elisabeth and Leonhardt, Michel and Pongratz, Herwig and Eichhorn, Emerich and Elz, Sigurd and Striegl, Birgit and Jenei-Lanzl, Zsuzsa and Dove, Stefan and Straub, Rainer H. and Kr{\"a}mer, Oliver H. and Mahboobi, Siavosh}, title = {Marbostat-100 Defines a New Class of Potent and Selective Antiinflammatory and Antirheumatic Histone Deacetylase 6 Inhibitors}, series = {Journal of medicinal chemistry}, volume = {61}, journal = {Journal of medicinal chemistry}, number = {8}, publisher = {ACS Publications}, doi = {10.1021/acs.jmedchem.7b01593}, pages = {3454 -- 3477}, abstract = {Epigenetic modifiers of the histone deacetylase (HDAC) family contribute to autoimmunity, cancer, HIV infection, inflammation, and neurodegeneration. Hence, histone deacetylase inhibitors (HDACi), which alter protein acetylation, gene expression patterns, and cell fate decisions, represent promising new drugs for the therapy of these diseases. Whereas pan-HDACi inhibit all 11 Zn2+-dependent histone deacetylases (HDACs) and cause a broad spectrum of side effects, specific inhibitors of histone deacetylase 6 (HDAC6i) are supposed to have less side effects. We present the synthesis and biological evaluation of Marbostats, novel HDAC6i that contain the hydroxamic acid moiety linked to tetrahydro-β-carboline derivatives. Our lead compound Marbostat-100 is a more potent and more selective HDAC6i than previously established well-characterized compounds in vitro as well as in cells. Moreover, Marbostat-100 is well tolerated by mice and effective against collagen type II induced arthritis. Thus, Marbostat-100 represents a most selective known HDAC6i and the possibility for clinical evaluation of a HDAC isoform-specific drug.}, language = {en} } @inproceedings{SieglRiegerKovariketal., author = {Siegl, Marco and Rieger, David and Kov{\´a}r{\´i}k, Tom{\´a}š and Ehrlich, Ingo}, title = {Long-Term Behavior of Thermoplastics under UV Light tested by a self-build Device}, series = {3. OTH-Clusterkonferenz, 13. April 2018, Weiden, Tagungsband; Festschrift, 5 Jahre OTH-Verbund}, booktitle = {3. OTH-Clusterkonferenz, 13. April 2018, Weiden, Tagungsband; Festschrift, 5 Jahre OTH-Verbund}, organization = {Ostbayerische Technische Hochschule}, pages = {118 -- 122}, abstract = {This article presents first results of artificial aging experi-ments by ultraviolet (UV) irradiation on thermoplasticmaterials conducted as an intent of the research project Thermoplastic Composite Structures (TheCoS) in colla-boration of the Ostbayerische Technische Hochschule(OTH) Regensburg and the University of West Bohemia(UWB) in Pilsen as part of a cross-border cooperation. In technical applications, thermoplastic materials are oftenaffected by aging and a related deterioration of the mechanical properties. Therefore, it is necessary to identifythe aging behavior of thermoplastic materials. For this,experiments were performed for three thermoplasticmaterials, namely polypropylene (PP), ultra high mole -cular weight polyethylene (UHMWPE) and high impactstrength polystyrene (HIPS). For these experiments, a UV chamber was constructed according to the internationalstandard EN ISO 4892-3 for simulation of exposurebehind window glass. The results are evaluated by testing the flexural strength and the dynamic mechanicalresponse after a selected period of time under UV lightand then compared to untreated test specimens.}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {MDR Implementation Status and Lessons Learned from the Past Months: A Notified Body Perspective}, series = {Cambridge Healthtech Institute's 2nd Annual Medical Device Clinical Trial Design and Operations: Trial Design and Technology to Optimize Medical Device Trials, Orlando, Florida + Virtual, 02.-03.03.2021}, journal = {Cambridge Healthtech Institute's 2nd Annual Medical Device Clinical Trial Design and Operations: Trial Design and Technology to Optimize Medical Device Trials, Orlando, Florida + Virtual, 02.-03.03.2021}, publisher = {Cambridge Innovation Institute}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {MDR implementation status \& lessons learned}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {European Union MDRs impact on device manufacturers: Reprocessing of surgical invasive devices, critical timeliness and technical documentation requirements under MDR}, series = {The validation of sterile medical devices: sterilization, packaging, biocompatibility, toxicology and reprocessing, Amsterdam, 26.03. - 28.03.2019 [Veranstalter: Nelson Labs ; Sterigenics]}, journal = {The validation of sterile medical devices: sterilization, packaging, biocompatibility, toxicology and reprocessing, Amsterdam, 26.03. - 28.03.2019 [Veranstalter: Nelson Labs ; Sterigenics]}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Challenges to innovate in the medical device industry under the light of the new EU MDR : a notified body perspective}, series = {Intelligent medical devices - the next disruptor in healthcare ; challenges and oppoertunieties: technical, clinical, regulatory and health economics/market access}, journal = {Intelligent medical devices - the next disruptor in healthcare ; challenges and oppoertunieties: technical, clinical, regulatory and health economics/market access}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Zus{\"a}tzliche Anforderungen an Produktdaten und technische Dokumentation durch die MDR}, series = {Medizintechnik Kongress 2018: Effizienz in der Medizinprodukteentwicklung vor dem Hintergrund von MDR und IVDR ; Frankfurt am Main, 08.11.2018, [Veranstalter: Velten Consulting \& ILC Consulting]}, journal = {Medizintechnik Kongress 2018: Effizienz in der Medizinprodukteentwicklung vor dem Hintergrund von MDR und IVDR ; Frankfurt am Main, 08.11.2018, [Veranstalter: Velten Consulting \& ILC Consulting]}, language = {de} } @misc{Singh, author = {Singh, Max Diamond}, title = {EU-MDR from a Notified Body Perspective - aktuelle Situation hinsichtlich der Anforderungen zum Lieferantenmanagement}, language = {de} } @misc{Singh, author = {Singh, Max Diamond}, title = {EU Medical Device Regulation: Top Challenges of Orthopedic Manufacturers}, series = {OMTEC 2019 : 15th Annual Orthopedic Manufacturing \& Technology Exposition and Conference, Chicago, 11.6.2019}, journal = {OMTEC 2019 : 15th Annual Orthopedic Manufacturing \& Technology Exposition and Conference, Chicago, 11.6.2019}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Conformity Assessment Procedure MDR}, series = {MDR Training: Person Responsible for Regulatory Compliance Course, 24.-25.02.2020, Tel Aviv, Obelis Academy}, journal = {MDR Training: Person Responsible for Regulatory Compliance Course, 24.-25.02.2020, Tel Aviv, Obelis Academy}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Managing Innovation from the Notified Body Perspective - Understanding the 3 C's of EU Regulations to Ensure Product Compliance: Changes, Challenges and Contributions}, series = {3rd annual european medical device and diagnostic product development and management meeting, 12-13 February 2019, Brussels}, journal = {3rd annual european medical device and diagnostic product development and management meeting, 12-13 February 2019, Brussels}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Notified body feedback: PSUR Forms. Post Market Surveillance \& Vigilance}, series = {MedTech Summit 2020: EU MDR \& IVDR: the end is in sight, Dublin/virtual, 20.-26.06.2020}, journal = {MedTech Summit 2020: EU MDR \& IVDR: the end is in sight, Dublin/virtual, 20.-26.06.2020}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {MDR - Die neuen rechtlichen Bedingungen f{\"u}r H{\"a}ndler und Hersteller: aus der Sicht einer benannten Stelle}, series = {MEGRA Jahrestagung. - Wien, 18.05.2020 [Veranstalter: Mitteleurop{\"a}ische Gesellschaft f{\"u}r Regulatory Affairs]}, journal = {MEGRA Jahrestagung. - Wien, 18.05.2020 [Veranstalter: Mitteleurop{\"a}ische Gesellschaft f{\"u}r Regulatory Affairs]}, language = {de} } @misc{Singh, author = {Singh, Max Diamond}, title = {Innovation challenges for orthopedic device manufacturers under the new EU MDR}, series = {ORS (Orthopaedic Research Society) Annual Meeting. - Phoenix, Arizona, 08. - 11.02.2020}, journal = {ORS (Orthopaedic Research Society) Annual Meeting. - Phoenix, Arizona, 08. - 11.02.2020}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {KARL STORZ Navigation Panel Unit - Navigation for ENT surgery}, series = {FESS 2010 : International Workshop on FESS ; Lectures \& Live Surgery. - Royal Pearl Hospital, Tiruchirappalli (Indien), 10.-11.04.2010}, journal = {FESS 2010 : International Workshop on FESS ; Lectures \& Live Surgery. - Royal Pearl Hospital, Tiruchirappalli (Indien), 10.-11.04.2010}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Medical Device Regulation}, series = {Forum MedTech Pharma: Start-ups in der Medizintechnik: Besonderheiten und Fallbeispiele, M{\"u}nchen, 17.7.2019}, journal = {Forum MedTech Pharma: Start-ups in der Medizintechnik: Besonderheiten und Fallbeispiele, M{\"u}nchen, 17.7.2019}, language = {de} } @misc{Singh, author = {Singh, Max Diamond}, title = {Market Access for Devices under MDD and MDR: Obligations for Manufacturers}, series = {OSMA - Orthopedic Surgical Manufacturers Association, Winter Educational Program - virtual}, journal = {OSMA - Orthopedic Surgical Manufacturers Association, Winter Educational Program - virtual}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Innovationsmanagement}, language = {de} } @misc{Singh, author = {Singh, Max Diamond}, title = {General Overview of the Medical Device Regulation}, series = {MDR-Roadshow - T{\"U}V S{\"U}D MHS, India}, journal = {MDR-Roadshow - T{\"U}V S{\"U}D MHS, India}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Stakeholder view on Post Market Surveillance under the EU MDR: Timelines, Compliance and Requirements ; Post Market Surveillance \& Vigilance}, series = {MedTech summit 2020: EU MDR \& IVDR: the end ist in sight, 22.-26.06.2020, Dublin/virtual}, journal = {MedTech summit 2020: EU MDR \& IVDR: the end ist in sight, 22.-26.06.2020, Dublin/virtual}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Quality in Medical Device Innovation for Start-ups, SME, and large enterprises through the new Medical Device Regulation}, series = {3rd European QA Conference, Dublin, 06. - 08.11.2019}, journal = {3rd European QA Conference, Dublin, 06. - 08.11.2019}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Technical Documentation MDR / IVDR, including the Declaration of Conformity}, series = {MDR Training: Person Responsible for Regulatory Compliance, 24.-25.02.2020, Tel Aviv, Obelis Academy}, journal = {MDR Training: Person Responsible for Regulatory Compliance, 24.-25.02.2020, Tel Aviv, Obelis Academy}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Notified Body Viewpoint : Preparing for MDR/IVDR}, series = {MDR/IVDR - Status Report from Stakeholders. Where are we now in November 2018? - Bern, 22.11.2018 - [Veranstalter: RAPS : Regulatory Affairs Professionals Society]}, journal = {MDR/IVDR - Status Report from Stakeholders. Where are we now in November 2018? - Bern, 22.11.2018 - [Veranstalter: RAPS : Regulatory Affairs Professionals Society]}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Reclassification of Orthopedic Devices per the Medical Device Regulation}, series = {OSMA Winter Educational Program, St. Petersburg/USA, 2019. - [Veranstalter: Orthopedic Surgical Manufacturers Association (OSMA)]}, journal = {OSMA Winter Educational Program, St. Petersburg/USA, 2019. - [Veranstalter: Orthopedic Surgical Manufacturers Association (OSMA)]}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Strategies to Navigate to the EU MDR and Clinical Requirements}, series = {Regulatory Affairs Professionals Society (RAPS): Session 1 - Tampa, Florida 2019}, journal = {Regulatory Affairs Professionals Society (RAPS): Session 1 - Tampa, Florida 2019}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Herausforderungen der Medizinprodukteindustrie bei der Internationalisierung}, series = {Studienwoche an der HNU (Hochschule Neu-Ulm) 2020}, journal = {Studienwoche an der HNU (Hochschule Neu-Ulm) 2020}, language = {de} }