@article{LotterBrebantEigenbergeretal., author = {Lotter, Luisa and Brebant, Vanessa and Eigenberger, Andreas and Hartmann, Robin and Mueller, Karolina and Baringer, Magnus and Prantl, Lukas and Schiltz, Daniel}, title = {"Topographic Shift": a new digital approach to evaluating topographic changes of the female breast}, series = {Archives of Gynecology and Obstetrics}, volume = {303}, journal = {Archives of Gynecology and Obstetrics}, number = {2}, publisher = {Springer Nature}, doi = {10.1007/s00404-020-05837-3}, pages = {515 -- 520}, abstract = {Purpose To assess precise topographic changes of the breast, objective documentation and evaluation of pre- and postoperative results are crucial. New technologies for mapping the body using digital, three-dimensional surface measurements have offered novel ways to numerically assess the female breast. Due to the lack of clear demarcation points of the breast contour, the selection of landmarks on the breast is highly dependent on the examiner, and, therefore, is prone to error when conducting before-after comparisons of the same breast. This study describes an alternative to volumetric measurements, focusing on topographic changes of the female breast, based on three-dimensional scans. Method The study was designed as an interventional prospective study of 10 female volunteers who had planned on having aesthetic breast augmentation with anatomical, textured implants. Three dimensional scans of the breasts were performed intraoperatively, first without and then with breast implants. The topographic change was determined as the mean distance between two three-dimensional layers before and after augmentation. This mean distance is defined as the Topographic Shift. Results The mean implant volume was 283 cc (SD = 68.6 cc, range = 210-395 cc). The mean Topographic Shift was 7.4 mm (SD = 1.9 mm, range = 4.8-10.7 mm). The mean Topographic Shifts per quadrant were: I: 8.0 mm (SD = 3.3 mm); II: 9.2 mm (SD = 3.1 mm); III: 6.9 mm (SD = 3.5 mm); IV: 1.9 mm (SD = 4.3 mm). Conclusion The Topographic Shift, describing the mean distance between two three-dimensional layers (for example before and after a volume changing therapy), is a new approach that can be used for assessing topographic changes of a body area. It was found that anatomical, textured breast implants cause a topographic change, particularly on the upper breast, in quadrant II, the decollete.}, language = {en} } @article{MaierZentgrafAngeleetal., author = {Maier, Eva and Zentgraf, Jan and Angele, Eveline and Zorzin, Jos{\´e} and Taschner, Michael and Widbiller, Matthias and Galler, Kerstin and Schratzenstaller, Thomas}, title = {A re-usable 3D-printed training model for the endodontic management of dental trauma in immature teeth}, series = {International endodontic journal}, volume = {2025}, journal = {International endodontic journal}, publisher = {Wiley}, issn = {1365-2591}, doi = {10.1111/iej.14235}, pages = {12}, abstract = {AIM: To develop a 3D-printed model enabling treatment simulation of trauma-related endodontic and restorative procedures like revitalization or placement of an apical plug on teeth with incomplete root formation. METHODOLOGY: To generate a realistic training model suitable for trauma-related simulations, CT-Data sets were segmented, combined, adjusted and optimized using computer-aided design features. Specific focus was on optimally reflecting characteristics of immature teeth like open apical foramina and thin root walls. For reflection of the revitalization process, a set-up including a tube filled with red liquid under pressure was developed to be perforated during the procedure by the trainee, simulating bleeding from the apical papilla into the root canal system. Design was based on a combination of cost-effective simple parts combined with 3D-printed components to achieve maximal accessibility, exchangeability and re-usability. Model assembly and preparation were described in step-by-step instructions. RESULTS: As a result of the developmental process, the presented model qualifies for the training of the endodontic management of complications on immature teeth after dental trauma. Step-by-step descriptions aligned with the clinical procedures are performable for a revitalization procedure, for pulpotomy followed by fragment re-attachment and splint application and for placement of an apical plug using hydraulic calcium silicate cements. CONCLUSIONS: The model successfully achieved its intended objectives, so that it may be used in the future in various dental trauma treatment simulations for undergraduate and postgraduate education on the endodontic management of trauma-related therapies in immature teeth. Its common manufacturing process, affordability and re-usability support accessibility and sustainability.}, language = {en} } @article{ManarancheHornberger, author = {Manaranche, Claire and Hornberger, Helga}, title = {A proposal for the classification of dental alloys according to their resistance to corrosion}, series = {Dental Materials}, volume = {23}, journal = {Dental Materials}, number = {11}, doi = {10.1016/j.dental.2006.11.030}, pages = {1428 -- 1437}, abstract = {Objectives The purpose of this study was to establish a method to compare and classify dental alloys in relation to their resistance to corrosion. Methods Alloy samples and pure metal samples were prepared and tested in chemical and electrochemical corrosion according to ISO 10271. For electrochemical test, the rest potential versus time and a potentiodynamic scan were recorded. After chemical corrosion test, the ions released were analyzed by ICP (induced coupled plasma) spectroscopy. Results High gold alloys had a similar polarization curve than gold. The same effect was observed for Pd-base alloys, their curves were similar to the one of palladium. The ions released during chemical corrosion were non-precious metallic ions. Thereby Ni-Cr alloys were found to release the most ions. Au-Pt alloys showed the highest release of ions compared with other precious alloys but low compared with Ni-Cr. Electrochemical corrosion was more aggressive than chemical corrosion and every type of elements was etched, the higher the precious metal content, the higher the resistance to corrosion of the alloy. Discussion Using the recorded data, a classification system for electrochemical corrosion was developed and discussed to judge the results. Hereby were gold and zinc used as reference materials. The applied classification system defines five classes and it is proposed that alloys of class V are not acceptable. For chemical corrosion resistance, three classes were distinguished according to the quantity of metallic ions released and it is proposed that class III (100-1000 μg/cm2 week) is not acceptable. Palladium and Pd-base alloys showed a higher electrochemical and chemical corrosion resistance than gold.}, language = {en} } @inproceedings{MarkusRuettenKrenkelKessler, author = {Markus R{\"u}tten, and Krenkel, Lars and Kessler, Roland}, title = {Secondary Flow Effects as Physical Mechanism of Molecular Species Transport in Highly Oscillating Generic-Trachea Flows}, series = {83rd Annual Scientific Conference of the International Association of Applied Mathematics and Mechanics, 26.-30. M{\"a}rz 2012, Darmstadt, Germany}, booktitle = {83rd Annual Scientific Conference of the International Association of Applied Mathematics and Mechanics, 26.-30. M{\"a}rz 2012, Darmstadt, Germany}, abstract = {The high frequency oscillation artificial respiration technique is often the last hope for patients to survive highly damaged lung tissue. The mortality can significantly be reduced. In comparison to conventional artificial respiration the applied volume flow rate and pressure is significantly lowered in order to avoid further damaging of lung tissue and remaining intact alveolae. However, the physical mechanism of transport of oxygen to the aeriols under high frequency oscillation is not well understood. In the upper part of the lung convection is dominant, in contrast, the gas exchange in the lower parts of the lung is mainly driven by diffusion. It is not clear how associated gradients of concentrations of different molecular species are then achieved. Highly oscillating fluid flows has been a long research topic in fluid dynamics. It is known that oscillating pressure fluctuations are able to induce secondary flows, in particular, in curved ducts and pipes. The question is, whether the trachea enforces the generation of secondary flow by its kidney like cross section geometry. The influence of molecular species of different densities onto the formation of secondary flows and the convectional transport within the trachea is investigated. In order to clarify the physical mechanisms behind flow simulations have been conducted by using state of the art CFD techniques.}, language = {en} } @misc{MelznerDendorfer, author = {Melzner, Maximilian and Dendorfer, Sebastian}, title = {Biomechanik und muskuloskeletale Simulation}, series = {Jahreskongress des ISPO Deutschland e.V., 2./3. Juni 2022, Hedelberg}, journal = {Jahreskongress des ISPO Deutschland e.V., 2./3. Juni 2022, Hedelberg}, organization = {International Society for Prosthetics and Orthotics}, language = {de} } @misc{MelznerEngelhardtSuessetal., author = {Melzner, Maximilian and Engelhardt, Leonard and S{\"u}ß, Friedrich and Dendorfer, Sebastian}, title = {Sensitivity evaluation of a musculoskeletal hand model using Latin hypercube sampling}, series = {ESMAC 2020 Abstracts}, volume = {81}, journal = {ESMAC 2020 Abstracts}, number = {Suppl. 1}, publisher = {Elsevier}, doi = {10.1016/j.gaitpost.2020.08.008}, language = {en} } @misc{MelznerEngelhardt, author = {Melzner, Maximilian and Engelhardt, Lucas}, title = {AnyBody Webcast - A new musculoskeletal AnyBody™ detailed hand model}, language = {en} } @inproceedings{MelznerEngelhardtHavelkovaetal., author = {Melzner, Maximilian and Engelhardt, Lucas and Havelkova, Leonard and Simon, Ulrich and Dendorfer, Sebastian}, title = {A new musculoskeletal AnyBody detailed hand model validated by electromyography}, series = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, booktitle = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, abstract = {The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands.}, language = {en} } @article{MelznerEngelhardtSimonetal., author = {Melzner, Maximilian and Engelhardt, Lucas and Simon, Ulrich and Dendorfer, Sebastian}, title = {Electromyography-Based Validation of a Musculoskeletal Hand Model}, series = {Journal of Biomechanical Engineering}, volume = {144}, journal = {Journal of Biomechanical Engineering}, number = {2}, publisher = {American Society of Mechanical Engineers, ASME}, doi = {10.1115/1.4052115}, pages = {8}, abstract = {Regarding the prevention of injuries and rehabilitation of the human hand, musculoskeletal simulations using an inverse dynamics approach allow for insights of the muscle recruitment and thus acting forces on the hand. Currently, several hand models from various research groups are in use, which are mainly validated by the comparison of numerical and anatomical moment arms. In contrast to this validation and model-building technique by cadaver studies, the aim of this study is to further validate a recently published hand model [1] by analyzing numerically calculated muscle activities in comparison to experimentally measured electromyographical signals of the muscles. Therefore, the electromyographical signals of 10 hand muscles of five test subjects performing seven different hand movements were measured. The kinematics of these tasks were used as input for the hand model, and the numerical muscle activities were computed. To analyze the relationship between simulated and measured activities, the time difference of the muscle on- and off-set points was calculated, which resulted in a mean on- and off-set time difference of 0.58 s between the experimental data and the model. The largest differences were detected for movements that mainly addressed the wrist. One major issue comparing simulated and measured muscle activities of the hand is cross-talk. Nevertheless, the results show that the hand model fits the experiment quite accurately despite some limitations and is a further step toward patient-specific modeling of the upper extremity.}, subject = {Elektromyographie}, language = {en} } @article{MelznerIsmailRušavyetal., author = {Melzner, Maximilian and Ismail, Khaled M. and Rušavy, Zdenek and Kališ, Vladim{\´i}r and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Musculoskeletal lower back load of accoucheurs during childbirth - A pilot and feasibility study}, series = {European Journal of Obstetrics \& Gynecology and Reproductive Biology}, journal = {European Journal of Obstetrics \& Gynecology and Reproductive Biology}, number = {264}, publisher = {Elsevier}, doi = {10.1016/j.ejogrb.2021.07.042}, pages = {306 -- 313}, abstract = {Introduction: Back problems represent one of the leading causes of accouchers' work-related musculoskeletal morbidities. The correct execution of birth-related maneuvers including manual perineal protection is crucial not only for the mother and child but also for obstetricians and midwives to reduce any strain on their musculoskeletal system. Therefore, the overall aim of this study was to test the feasibility of determining the effect of different accouchers' postures (standing and kneeling) on their musculoskeletal system. Methods: The biomechanical analysis is based on musculoskeletal simulations that included motion recordings of real deliveries as well as deliveries conducted on a birthing simulator. These simulations were then used to determine individual joints' loads. Results: In the kneeling posture, both a low intra-operator variability and a lower average maximum load of the lower back was observed. For the standing position the spine load was reduced by pivoting the elbow on the accouchers' thigh, which in turn was associated with a significantly greater load on the shoulder joint. Conclusion: The study demonstrated the feasibility of our technique to assess joints loads. It also provided initial data indicating that a posture that reduces spinal flexion and tilt, achieved in this study by the kneeling, can significantly reduce the strain on the practitioner's musculoskeletal system.}, language = {en} } @misc{MelznerIsmailRušavyetal., author = {Melzner, Maximilian and Ismail, Khaled M. and Rušav{\´y}, Zdeněk and Kališ, Vladim{\´i}r and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Musculoskeletal Lower Back Load of Accoucheurs During Delivery}, series = {26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy}, journal = {26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy}, address = {Milan}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-20208}, abstract = {With the progress in modern medicine, it was possible to significantly reduce the risks of birth for mother and child. One aspect that has received less attention so far is the risk of injury to the accoucheurs (obstetricians and midwives) during the birth process. Indeed, studies indicate that 92\% of midwives suffer from musculoskeletal disorders, with the lower back being the main cause of complaints (72\%). The aim of this study was to investigate two commonly used postural techniques used by accoucheurs during childbirth and to analyze the resulting load on the lower back using the AnyBodyTM musculoskeletal simulation software.}, language = {en} } @misc{MelznerPfeiferAltetal., author = {Melzner, Maximilian and Pfeifer, Christian and Alt, V. and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {{\"A}nderung der Gelenkreaktionskraft bei Sch{\"a}digung des medialen Bandapparates im Ellenbogen}, series = {Zeitschrift fur Orthopadie und Unfallchirurgie}, volume = {158}, journal = {Zeitschrift fur Orthopadie und Unfallchirurgie}, number = {S01}, publisher = {Thieme}, doi = {10.1055/s-0040-1717270}, language = {de} } @misc{MelznerPfeiferSuessetal., author = {Melzner, Maximilian and Pfeifer, Christian and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Muskuloskeletal analysis of elbow stability for common injury patterns}, series = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, journal = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, pages = {654}, language = {en} } @article{MelznerPfeifferSuessetal., author = {Melzner, Maximilian and Pfeiffer, Christian and Suess, Franz and Dendorfer, Sebastian}, title = {Musculoskeletal simulation of elbow stability for common injury patterns}, series = {Journal of Orthopaedic Research}, volume = {41}, journal = {Journal of Orthopaedic Research}, number = {6}, publisher = {Wiley}, issn = {1554-527X}, doi = {10.1002/jor.25460}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-54819}, pages = {1356 -- 1364}, abstract = {Elbow stability is derived from a combination of muscular, ligamentous, and bony structures. After an elbow trauma the stability of the joint is an important decision criterion for the subsequent treatment. The decision regarding non-operative/operative care depends mostly on subjective assessments of medical experts. Therefore, the aim of this study is to use musculoskeletal simulations as an objective assessment tool to investigate the extent to which failure of different stabilizers affects the elbow stability and how these observations correspond to the assessment from clinical practice. A musculoskeletal elbow simulation model was developed for this aim. To investigate the stability of the elbow, varus/valgus moments were applied under 0°, 45°and 90° flexion while the respective cubital angle was analyzed. This was performed for nine different injury scenarios, which were also evaluated for stability by clinical experts. With the results, it can be determined by which injury pattern and under which flexion angle the elbow stability is impaired regarding varus/valgus moments. The scenario with a complete failure of the medial and lateral ligaments and a fracture of the radial head was identified as having the greatest instability. The study presented a numerical determination of elbow stability against varus/valgus moments regarding clinical injury patterns, as well as a comparison of the numerical outcome with experience gained in clinical practice. The numerical predictions agree well with the assessments of the clinical specialists. Thus, the results from musculoskeletal simulation can make an important contribution to a more objective assessment of the elbow stability.}, language = {en} } @article{MelznerSuessDendorfer, author = {Melzner, Maximilian and Suess, Franz and Dendorfer, Sebastian}, title = {The impact of anatomical uncertainties on the predictions of a musculoskeletal hand model - a sensitivity study}, series = {Computer Methods in Biomechanics and Biomedical Engineering}, volume = {25}, journal = {Computer Methods in Biomechanics and Biomedical Engineering}, number = {2}, publisher = {Taylor \& Francis}, issn = {1476-8259}, doi = {10.1080/10255842.2021.1940974}, pages = {156 -- 164}, abstract = {Outputs of musculoskeletal models should be considered probabilistic rather than deterministic as they are affected by inaccuracies and estimations associated with the development of the model. One of these uncertainties being critical for modeling arises from the determination of the muscles' line of action and the physiological cross-sectional area. Therefore, the aim of this study was to evaluate the outcome sensitivity of model predictions from a musculoskeletal hand model in comparison to the uncertainty of these input parameters. For this purpose, the kinematics and muscle activities of different hand movements (abduction of the fingers, abduction of the thumb, and flexion of the thumb) were recorded. One thousand simulations were calculated for each movement using the Latin hypercube sampling method with a corresponding variation of the muscle origin/insertion points and the cross-sectional area. Comparing the standard hand to simulations incorporating uncertainties of input parameters shows no major deviations in on- and off-set time point of muscle activities. About 60\% of simulations are located within a ± 30\% interval around the standard model concerning joint reaction forces. The comparison with the variation of the input data leads to the conclusion that the standard hand model is able to provide not over-scattered outcomes and, therefore, can be considered relatively stable. These results are of practical importance to the personalization of a musculoskeletal model with subject-specific bone geometries and hence changed muscle line of action.}, subject = {Biomechanik}, language = {en} } @article{MoragKieningerEissnertetal., author = {Morag, Sarah and Kieninger, Martin and Eissnert, Christoph and Auer, Simon and Dendorfer, Sebastian and Popp, Daniel and Hoffmann, Johannes and Kieninger, B{\"a}rbel}, title = {Comparison of different techniques for prehospital cervical spine immobilization: Biomechanical measurements with a wireless motion capture system}, series = {PLOS ONE}, volume = {18}, journal = {PLOS ONE}, number = {11}, publisher = {PLOS}, address = {San Francisco, California}, doi = {10.1371/journal.pone.0292300}, pages = {1 -- 14}, language = {en} } @inproceedings{MuehlingEnglertDendorfer, author = {Muehling, M. and Englert, Carsten and Dendorfer, Sebastian}, title = {Influence of biceps tenotomy and tenodesis on post-operative shoulder strength}, series = {Jahrestagung der Deutschen Gesellschaft f{\"u}r Biomechanik, March 2017, Hannover, Germany}, booktitle = {Jahrestagung der Deutschen Gesellschaft f{\"u}r Biomechanik, March 2017, Hannover, Germany}, language = {en} } @article{MuehlingSandriesserDendorferetal., author = {M{\"u}hling, Mischa and Sandriesser, Sabrina and Dendorfer, Sebastian and Augat, Peter}, title = {Assessment of implant internal stresses under physiological femoral loading: Translation to a simplified bending load model}, series = {Journal of Biomechanics}, journal = {Journal of Biomechanics}, number = {112229}, publisher = {Elsevier}, issn = {1873-2380}, doi = {10.1016/j.jbiomech.2024.112229}, pages = {17}, abstract = {The success of surgical treatment for fractures hinges on various factors, notably accurate surgical indication. The process of developing and certifying a new osteosynthesis device is a lengthy and costly process that requires multiple cycles of review and validation. Current methods, however, often rely on predecessor standards rather than physiological loads in specific anatomical locations. This study aimed to determine actual loads experienced by an osteosynthesis plate, exemplified by a standard locking plate for the femoral shaft, utilizing finite elements analysis (FEA) and to obtain the bending moments for implant development standard tests. A protocol was developed, involving the creation and validation of a fractured femur model fixed with a locking plate, mechanical testing, and FEA. The model's validation demonstrated exceptional accuracy in predicting deformations, and the FEA revealed peak stresses in the fracture bridging zone. Results of a parametric analysis indicate that larger fracture gaps significantly impact implant mechanical behavior, potentially compromising stability. This study underscores the critical need for realistic physiological conditions in implant evaluations, providing an innovative translational approach to identify internal loads and optimize implant designs. In conclusion, this research contributes to enhancing the understanding of implant performance under physiological conditions, promoting improved designs and evaluations in fracture treatments.}, language = {en} } @inproceedings{NonnKalwa, author = {Nonn, Aida and Kalwa, Christoph}, title = {Application of damage mechanics approach for crack propagation in pipeline}, series = {19th Biennial Joint Technical Meeting (JTM) on Pipeline Research, April 29 - May 3, 2013, Sydney, Australia}, booktitle = {19th Biennial Joint Technical Meeting (JTM) on Pipeline Research, April 29 - May 3, 2013, Sydney, Australia}, language = {en} } @article{ObermaierLehleSchmidetal., author = {Obermaier, Lisa and Lehle, Karla and Schmid, Stefanie and Schmid, Christof and Schratzenstaller, Thomas}, title = {Introduction of a new ex vivo porcine coronary artery model: Evaluation of the direct vascular injury after stent implantation with and without dogbone effect}, series = {European Surgical Research}, volume = {63}, journal = {European Surgical Research}, number = {4}, publisher = {Karger}, address = {Basel}, issn = {1421-9921}, doi = {10.1159/000527883}, pages = {285 -- 293}, abstract = {Introduction: Neointimal hyperplasia after percutaneous coronary intervention remains a major determinant of in-stent restenosis (ISR). The extent of mechanical vessel injury correlates with ISR. A new ex vivo porcine stent model was introduced and evaluated comparing different stent designs. Methods: Coronary arteries were prepared from pig hearts from the slaughterhouse and used for ex vivo implantations of coronary stents. One basic stent design in two configurations (dogbone, DB; non-dogbone, NDB) was used. Vascular injury was determined according to a modified injury score (IS). Results: Standardized experimental conditions ensured comparable vessel dimensions and overstretch data. DB stents caused more severe IS compared to NDB stents. The mean IS and the IS at the distal end of all stents were significantly reduced for NDB stents (ISMean, DB, 1.16 ±0.12; NDB, 1.02 ±0.12; p=0.018; ISDist, DB, 1.39 ±0.28; NDB, 1.13 ±0.24; p=0.03). Discussion/Conclusion: The introduced ex-vivo model allowed the evaluation of different stent designs exclude unfavorable stent designs.}, language = {en} } @article{OttRosengarthDoenitzetal., author = {Ott, Christian and Rosengarth, Katharina and Doenitz, Christian and Hoehne, Julius and Wendl, Christina and Dodoo-Schittko, Frank and Lang, Elmar Wolfgang and Schmidt, Nils Ole and Goldhacker, Markus}, title = {Preoperative Assessment of Language Dominance through Combined Resting-State and Task-Based Functional Magnetic Resonance Imaging}, series = {Journal of personalized medicine}, volume = {11}, journal = {Journal of personalized medicine}, number = {12}, publisher = {MDPI}, doi = {10.3390/jpm11121342}, abstract = {Brain lesions in language-related cortical areas remain a challenge in the clinical routine. In recent years, the resting-state fMRI (RS-fMRI) was shown to be a feasible method for preoperative language assessment. The aim of this study was to examine whether language-related resting-state components, which have been obtained using a data-driven independent-component-based identification algorithm, can be supportive in determining language dominance in the left or right hemisphere. Twenty patients suffering from brain lesions close to supposed language-relevant cortical areas were included. RS-fMRI and task-based (TB-fMRI) were performed for the purpose of preoperative language assessment. TB-fMRI included a verb generation task with an appropriate control condition (a syllable switching task) to decompose language-critical and language-supportive processes. Subsequently, the best fitting ICA component for the resting-state language network (RSLN) referential to general linear models (GLMs) of the TB-fMRI (including models with and without linguistic control conditions) was identified using an algorithm based on the Dice index. Thereby, the RSLNs associated with GLMs using a linguistic control condition led to significantly higher laterality indices than GLM baseline contrasts. LIs derived from GLM contrasts with and without control conditions alone did not differ significantly. In general, the results suggest that determining language dominance in the human brain is feasible both with TB-fMRI and RS-fMRI, and in particular, the combination of both approaches yields a higher specificity in preoperative language assessment. Moreover, we can conclude that the choice of the language mapping paradigm is crucial for the mentioned benefits.}, language = {en} } @article{PaschkeFoltanWagneretal., author = {Paschke, Lukas and Foltan, Maik and Wagner, Maria S. and Lubnow, Matthias and Gruber, Michael and Krenkel, Lars and Lehle, Karla}, title = {Clinical Relevance of Platelet-Leukocyte Aggregates and Platelet P-Selectin Expression During Venovenous Extracorporeal Membrane Oxygenation}, series = {ASAIO Journal}, journal = {ASAIO Journal}, number = {April 03}, publisher = {Wolters Kluwer}, issn = {1058-2916}, doi = {10.1097/MAT.0000000000002421}, abstract = {Thrombosis continues to be a significant complication during venovenous extracorporeal membrane oxygenation (V-V ECMO). Platelet activation markers might serve as indicators of inflammation and thrombogenesis. The aim was to identify these markers in ECMO patients. Blood from 10 ECMO patients (before, during, after ECMO) and 11 healthy volunteers were collected to determine platelet-neutrophil-aggregates (PNAs), platelet-monocyte-aggregates (PMAs), fibrinogen-binding, and P-selectin-expression on platelets by flow cytometry. Critical illness was associated with significantly elevated levels of PNAs and PMAs, increased P-selectin expression, reduced fibrinogen-binding, and restricted activation of platelets. Although PNAs and PMAs decreased significantly within 2 hours after the initiation of ECMO and remained at those levels, ECMO did not affect basal P-selectin expression and fibrinogen-binding. These results correlated with coagulation activation. Platelet markers before ECMO were not indicators for an imminent system exchange and end of therapy. In conclusion, platelet dysfunction during ECMO was mainly attributed to the critical illness. Extracorporeal membrane oxygenation support strengthened the restricted response of platelets to exogenous agonists (P-selectin). Furthermore, a decrease in PNAs/PMAs after ECMO started identified a reduced inflammatory response. There was no correlation of analyzed platelet parameters with the incidence of thrombotic complications.}, language = {en} } @article{PenzkoferBarnsteinerDendorfer, author = {Penzkofer, Rainer and Barnsteiner, K. and Dendorfer, Sebastian}, title = {The influence of age, shoe type and kicking direction on the severity of head trauma}, series = {Journal of Forensic Biomechanics}, volume = {5}, journal = {Journal of Forensic Biomechanics}, number = {1}, doi = {10.4172/2090-2697.1000116}, abstract = {In the last few years, increasingly kicks to the head were observed as a criminal offense. This study examined the influence of age, shoe type and kicking direction on the severity of head trauma. Male test persons were divided into two groups "Old" and "Young". Both groups were equipped with light sneakers and combat boots. A standard laboratory crash dummy was used to simulate the victim's body. First, the dummy's head, free floating above the ground, was kicked vertically. Second, the dummy's head was kicked horizontally. Established injury criteria were used to quantify the injury risk. No influence concerning the type of foot wear and no difference between the groups "Old" and "Young" could be found. For all analyses, kicking vertically generally lead to a higher risk for the subject compared to kicking horizontally. In this study, only the integral effect of the kicks could be analyzed. A detailed injury pattern cannot directly be derived from the data. Nevertheless, the presented data show the massive potential of injuries associated with head kicks.}, subject = {Kopfverletzung}, language = {en} } @inproceedings{PenzkoferGrechenigKujatetal., author = {Penzkofer, Rainer and Grechenig, S. and Kujat, Richard and Angele, Peter and Dendorfer, Sebastian}, title = {Biomechanical comparison of the dorsal femur condyles and the iliac crest in terms of failure behavior}, series = {XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015}, booktitle = {XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015}, language = {en} } @article{PfeiferMuellerPrantletal., author = {Pfeifer, Christian and M{\"u}ller, Michael and Prantl, Lukas and Berner, Arne and Dendorfer, Sebastian and Englert, Carsten}, title = {Cartilage labelling for mechanical testing in T-peel configuration}, series = {International Orthopaedics}, volume = {36}, journal = {International Orthopaedics}, number = {7}, publisher = {Springer}, doi = {10.1007/s00264-011-1468-3}, pages = {1493 -- 1499}, abstract = {PURPOSE: The purpose of this study was to find a suitable method of labelling cartilage samples for the measurement of distraction distances in biomechanical testing. METHODS: Samples of bovine cartilage were labelled using five different methods: hydroquinone and silver nitrate (AgNO3), potassium permanganate (KMnO4) with sodium thiosulphate (Na2S2O3), India ink, heat, and laser energy. After the labelling, we analysed the cartilage samples with regard to cytotoxity by histochemical staining with ethidiumbromide homodimer (EthD-1) and calcein AM. Furthermore, we tested cartilages labelled with India ink and heat in a T-peel test configuration to analyse possible changes in the mechanical behaviour between marked and unlabelled samples. RESULTS: Only the labelling methods with Indian ink or a heated needle showed acceptable results in the cytotoxity test with regard to labelling persistence, accuracy, and the influence on consistency and viability of the chondrocytes. In the biomechanical T-peel configuration, heat-labelled samples collapsed significantly earlier than unlabelled samples. CONCLUSION: Labelling bovine cartilage samples with Indian ink in biomechanical testing is a reliable, accurate, inexpensive, and easy-to-perform method. This labelling method influenced neither the biomechanical behaviour nor the viability of the tissue compared to untreated bovine cartilage.}, subject = {Knorpel}, language = {en} } @article{PhilippdeSomerFoltanetal., author = {Philipp, Alois and de Somer, Filip and Foltan, Maik and Bredthauer, Andre and Krenkel, Lars and Zeman, Florian and Lehle, Karla}, title = {Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice}, series = {PLOS ONE}, volume = {13}, journal = {PLOS ONE}, number = {6}, publisher = {PLOS}, doi = {10.1371/journal.pone.0198392}, pages = {1 -- 10}, abstract = {Over the past decade, veno-venous extracorporeal membrane oxygenation (vvECMO) has been increasingly utilized in respiratory failure in patients. This study presents our institution´s experience focusing on the life span of ECMO systems reflecting the performance of a particular system. A retrospective review of our ECMO database identified 461 adult patients undergoing vvECMO (2010-2017). Patients that required more than one system and survived the first exchange >24 hours (n = 139) were included. Life span until the first exchange and exchange criteria were analyzed for all systems (PLS, Cardiohelp HLS-set, both Maquet Cardiopulmonary, Rastatt, Germany; Deltastream/Hilite7000LT, iLA-activve, Xenios/NovaLung, Heilbronn, Germany; ECC.O5, LivaNova, Mirandola, Italy). At our ECMO center, the frequency of a system exchange was 30\%. The median (IQR) life span was 9 (6-12) days. There was no difference regarding the different systems (p = 0.145 and p = 0.108, respectively). However, the Deltastream systems were exchanged more frequently due to elective technical complications (e. g. worsened gas transfer, development of coagulation disorder, increased bleedings complications) compared to the other exchanged systems (p = 0.013). In summary, the used ECMO systems are safe and effective for acute respiratory failure. There is no evidence for the usage of a specific system. Only the increased predictability of an imminent exchange preferred the usage of a Deltastream system. However, the decision to use a particular system should not depend solely on the possible criteria for an exchange.}, language = {en} } @inproceedings{PillingSuessKubowitschetal., author = {Pilling, A. and S{\"u}ß, Franz and Kubowitsch, Simone and Dendorfer, Sebastian}, title = {Experimental workflow for determining psychological stress from physiological biosignals}, series = {Jahrestagung der BIOMEDIZINISCHEN TECHNIK und Dreil{\"a}ndertagung der MEDIZINISCHEN PHYSIK, Dresden, Germany, 2017}, booktitle = {Jahrestagung der BIOMEDIZINISCHEN TECHNIK und Dreil{\"a}ndertagung der MEDIZINISCHEN PHYSIK, Dresden, Germany, 2017}, language = {en} } @article{PlankRosengarthSchmalhoferetal., author = {Plank, Tina and Rosengarth, Katharina and Schmalhofer, Carolin and Goldhacker, Markus and Brandl-R{\"u}hle, Sabine and Greenlee, Mark W.}, title = {Perceptual learning in patients with macular degeneration}, series = {Frontiers in psychology}, volume = {5}, journal = {Frontiers in psychology}, publisher = {Frontiers Research Foundation}, address = {Lausanne}, issn = {1664-1078}, doi = {10.3389/fpsyg.2014.01189}, pages = {1 -- 14}, abstract = {Patients with age-related macular degeneration (AMD) or hereditary macular dystrophies (JMD) rely on an efficient use of their peripheral visual field. We trained eight AMD and five JMD patients to perform a texture-discrimination task (TDT) at their preferred retinal locus (PRL) used for fixation. Six training sessions of approximately one hour duration were conducted over a period of approximately 3 weeks. Before, during and after training twelve patients and twelve age-matched controls (the data from two controls had to be discarded later) took part in three functional magnetic resonance imaging (fMRI) sessions to assess training-related changes in the BOLD response in early visual cortex. Patients benefited from the training measurements as indexed by significant decrease (p = 0.001) in the stimulus onset asynchrony (SOA) between the presentation of the texture target on background and the visual mask, and in a significant location specific effect of the PRL with respect to hit rate (p = 0.014). The following trends were observed: (i) improvement in Vernier acuity for an eccentric line-bisection task; (ii) positive correlation between the development of BOLD signals in early visual cortex and initial fixation stability (r = 0.531); (iii) positive correlation between the increase in task performance and initial fixation stability (r = 0.730). The first two trends were non-significant, whereas the third trend was significant at p = 0.014, Bonferroni corrected. Consequently, our exploratory study suggests that training on the TDT can enhance eccentric vision in patients with central vision loss. This enhancement is accompanied by a modest alteration in the BOLD response in early visual cortex.}, language = {en} } @article{PrantlEigenbergerGehmertetal., author = {Prantl, Lukas and Eigenberger, Andreas and Gehmert, Sebastian and Haerteis, Silke and Aung, Thiha and Rachel, Reinhard and Jung, Ernst Michael and Felthaus, Oliver}, title = {Enhanced Resorption of Liposomal Packed Vitamin C Monitored by Ultrasound}, series = {Journal of Clinical Medicine}, volume = {9}, journal = {Journal of Clinical Medicine}, number = {6}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/jcm9061616}, pages = {1 -- 12}, abstract = {Vitamin C is an essential nutrient for humans and is involved in a plethora of health-related functions. Several studies have shown a connection between vitamin C intake and an improved resistance to infections that involves the immune system. However, the body cannot store vitamin C and both the elevated oral intake, and the intravenous application have certain disadvantages. In this study, we wanted to show a new formulation for the liposomal packaging of vitamin C. Using freeze etching electron microscopy, we show the formed liposomes. With a novel approach of post-processing procedures of real-time sonography that combines enhancement effects by contrast-like ultrasound with a transducer, we wanted to demonstrate the elevated intestinal vitamin C resorption on four participants. With the method presented in this study, it is possible to make use of the liposomal packaging of vitamin C with simple household materials and equipment for intake elevation. For the first time, we show the enhanced resorption of ingested liposomes using microbubble enhanced ultrasound imaging.}, language = {en} } @article{PrantlEigenbergerKleinetal., author = {Prantl, Lukas and Eigenberger, Andreas and Klein, Silvan and Limm, Katharina and Oefner, Peter J. and Schratzenstaller, Thomas and Felthaus, Oliver}, title = {Shear Force Processing of Lipoaspirates for Stem Cell Enrichment Does Not Affect Secretome of Human Cells Detected by Mass Spectrometry In Vitro}, series = {Plastic and Reconstructive Surgery}, volume = {146}, journal = {Plastic and Reconstructive Surgery}, number = {6}, publisher = {American Society of Plastic Surgeons}, doi = {10.1097/PRS.0000000000007343}, pages = {749e -- 758e}, abstract = {Background: Lipofilling is one of the most often performed surgical procedures in plastic and reconstructive surgery. Lipoaspirates provide a ready source of stem cells and secreted factors that contribute to neoangiogenesis and fat graft survival. However, the regulations about the enrichment of these beneficial cells and factors are ambiguous. In this study, the authors tested whether a combination of centrifugation and homogenization allowed the enrichment of viable stem cells in lipoaspirates through the selective removal of tumescent solution, blood, and released lipids without significantly affecting the cell secretome. Methods: Human lipoaspirate was harvested from six different patients using water jet-assisted liposuction. Lipoaspirate was homogenized by first centrifugation (3584 rpm for 2 minutes), shear strain (10 times intersyringe processing), and second centrifugation (3584 rpm for 2 minutes). Stem cell enrichment was shown by cell counting after stem cell isolation. Lipoaspirate from different processing steps (unprocessed, after first centrifugation, after homogenization, after second centrifugation) was incubated in serum-free cell culture medium for mass spectrometric analysis of secreted proteins. Results: Lipoaspirate homogenization leads to a significant 2.6 ± 1.75-fold enrichment attributable to volume reduction without reducing the viability of the stem cells. Protein composition of the secretome did not change significantly after tissue homogenization. Considering the enrichment effects, there were no significant differences in the protein concentration of the 83 proteins found in all processing steps. Conclusions: Stem cells can be enriched mechanically without significantly affecting the composition of secreted proteins. Shear-assisted enrichment of lipoaspirate constitutes no substantial manipulation of the cells' secretome.}, language = {en} } @article{PrantlEigenbergerReinhardetal., author = {Prantl, Lukas and Eigenberger, Andreas and Reinhard, Ruben and Siegmund, Andreas and Heumann, Kerstin and Felthaus, Oliver}, title = {Cell-Enriched Lipotransfer (CELT) Improves Tissue Regeneration and Rejuvenation without Substantial Manipulation of the Adipose Tissue Graft}, series = {Cells}, volume = {11}, journal = {Cells}, number = {19}, publisher = {MDPI}, doi = {10.3390/cells11193159}, pages = {1 -- 11}, abstract = {The good availability and the large content of adult stem cells in adipose tissue has made it one of the most interesting tissues in regenerative medicine. Although lipofilling is one of the most frequent procedures in plastic surgery, the method still struggles with high absorption rates and volume losses of up to 70\%. Therefore, many efforts have been made to optimize liposuction and to process the harvested tissue in order to increase fat graft retention. Because of their immunomodulatory properties, their cytokine secretory activity, and their differentiation potential, enrichment with adipose tissue-derived stem cells was identified as a promising tool to promote transplant survival. Here, we review the important parameters for lipofilling optimization. Finally, we present a new method for the enrichment of lipoaspirate with adipose tissue-derived stem cells and discuss the parameters that contribute to fat graft survival.}, language = {en} } @phdthesis{Putzer, author = {Putzer, Michael}, title = {Development of subject-specific musculoskeletal models for studies of lumbar loading}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:706-5924}, pages = {140}, abstract = {Anatomical differences between individuals are often neglected in musculoskeletal models, but they are necessary in case of subject-specific questions regarding the lumbar spine. A modification of models to each subject is complex and the effects on lumbar loading are difficult to assess. The objective of this thesis is to create a validated musculoskeletal model of the human body, which facilitates a subject-specific modification of the geometry of the lumbar spine. Furthermore, important parameters are identified in sensitivity studies and a case study regarding multifidus muscle atrophy after a disc herniation is conducted. Therefore, a generic model is heavily modified and a semi-automatic process is implemented. This procedure remodels the geometry of the lumbar spine to a subject-specific one on basis of segmented medical images. The resulting five models are validated with regard to the lumbar loading at the L4/L5 level. The influence of lumbar ligament stiffness is determined by changing the stiffness values of all lumbar ligaments in eleven steps during a flexion motion. Sensitivities of lumbar loading to an altered geometry of the lumbar spine are identified by varying ten lumbar parameters in simulations with each model in four postures. The case study includes an analysis of the loading of the multifidus muscle and of the lumbar discs throughout various stages of disc herniation. This time each model performs four motions with two different motion rhythms. The results indicate that lumbar motion and loading is dependent on lumbar ligament stiffness. Furthermore, subject-specific modelling of the lumbar spine should include at least the vertebral height, disc height and lumbar lordosis. The results of the case study suggest that an overloading of the multifidus muscle could follow disc herniation. Additionally, a subsequent atrophy of the muscles could expose adjacent levels to an increased loading, but these findings are highly dependent on the individual.}, subject = {Lendenwirbels{\"a}ule}, language = {en} } @phdthesis{Putzer, author = {Putzer, Michael}, title = {Development of subject-specific musculoskeletal models for studies of lumbar loading}, publisher = {Shaker Verlag}, address = {D{\"u}ren}, isbn = {978-3-8440-6695-1}, doi = {10.2370/9783844066951}, pages = {142}, abstract = {Anatomical differences between individuals are often neglected in musculoskeletal models, but they are necessary in case of subject-specific questions regarding the lumbar spine. A modification of models to each subject is complex and the effects on lumbar loading are difficult to assess. One objective of this work is to create a validated musculoskeletal human model, which facilitates a subject-specific modification of the lumbar geometry. In a second step, important parameters are identified in sensitivity studies and at last, a case study regarding multifidus muscle atrophy after a disc herniation is conducted. The results of the studies indicate that lumbar motion and loading is dependent on lumbar ligament stiffness. Furthermore, subject-specific modelling of the lumbar spine should include at least the vertebral height, disc height and lumbar lordosis. The results of the case study suggest that an overloading of the multifidus muscle could follow disc herniation. Additionally, a subsequent atrophy of the muscles could expose adjacent levels to an increased loading, but these findings are highly dependent on the individual.}, language = {en} } @article{PutzerAuerMalpicaetal., author = {Putzer, Michael and Auer, Stefan and Malpica, William and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {A numerical study to determine the effect of ligament stiffness on kinematics of the lumbar spine during flexion}, series = {BMC Musculoskeletal Disorders}, volume = {17}, journal = {BMC Musculoskeletal Disorders}, number = {95}, doi = {10.1186/s12891-016-0942-x}, abstract = {Background There is a wide range of mechanical properties of spinal ligaments documented in literature. Due to the fact that ligaments contribute in stabilizing the spine by limiting excessive intersegmental motion, those properties are of particular interest for the implementation in musculoskeletal models. The aim of this study was to investigate the effect of varying ligament stiffness on the kinematic behaviour of the lumbar spine. Methods A musculoskeletal model with a detailed lumbar spine was modified according to fluoroscopic recordings and corresponding data files of three different subjects. For flexion, inverse dynamics analysis with a variation of the ligament stiffness matrix were conducted. The influence of several degrees of ligament stiffness on the lumbar spine model were investigated by tracking ligament forces, disc forces and resulting moments generated by the ligaments. Additionally, the kinematics of the motion segments were evaluated. Results An increase of ligament stiffness resulted in an increase of ligament and disc forces, whereas the relative change of disc force increased at a higher rate at the L4/L5 level (19 \%) than at the L3/L4 (10 \%) level in a fully flexed posture. The same behaviour applied to measured moments with 67 \% and 45 \%. As a consequence, the motion deflected to the lower levels of the lumbar spine and the lower discs had to resist an increase in loading. Conclusions Higher values of ligament stiffness over all lumbar levels could lead to a shift of the loading and the motion between segments to the lower lumbar levels. This could lead to an increased risk for the lower lumbar parts.}, language = {en} } @inproceedings{PutzerDendorfer, author = {Putzer, Michael and Dendorfer, Sebastian}, title = {Sensitivity of lumbar spine loading to anatomical parameters}, series = {International Workshop on Spine Loading and Deformation: From Loading to Recovery, 2-4 July 2015, Julius Wolff Institute, Charit{\´e}-Universitatsmedizin Berlin, Germany}, booktitle = {International Workshop on Spine Loading and Deformation: From Loading to Recovery, 2-4 July 2015, Julius Wolff Institute, Charit{\´e}-Universitatsmedizin Berlin, Germany}, language = {en} } @article{PutzerEhrlichRasmussenetal., author = {Putzer, Michael and Ehrlich, Ingo and Rasmussen, John and Gebbeken, Norbert and Dendorfer, Sebastian}, title = {Sensitivity of lumbar spine loading to anatomical parameters}, series = {Journal of Biomechanics}, volume = {49}, journal = {Journal of Biomechanics}, number = {6}, publisher = {Elsevier Science}, doi = {10.1016/j.jbiomech.2015.11.003}, pages = {953 -- 958}, abstract = {Musculoskeletal simulations of lumbar spine loading rely on a geometrical representation of the anatomy. However, this data has an inherent inaccuracy. This study evaluates the influence of defined geometrical parameters on lumbar spine loading utilising five parametrised musculoskeletal lumbar spine models for four different postures. The influence of the dimensions of vertebral body, disc, posterior parts of the vertebrae as well as the curvature of the lumbar spine was studied. Additionally, simulations with combinations of selected parameters were conducted. Changes in L4/L5 resultant joint force were used as outcome variable. Variations of the vertebral body height, disc height, transverse process width and the curvature of the lumbar spine were the most influential. These parameters can be easily acquired from X-rays and should be used to morph a musculoskeletal lumbar spine model for subject-specific approaches with respect to bone geometry. Furthermore, the model was very sensitive to uncommon configurations and therefore, it is advised that stiffness properties of discs and ligaments should be individualised.}, subject = {Wirbels{\"a}ule}, language = {en} } @inproceedings{PutzerGalibarovDendorfer, author = {Putzer, Michael and Galibarov, Pavel E. and Dendorfer, Sebastian}, title = {Influence of vertebral parameters on lumbar spine loading}, series = {Pre-meeting SpineFX, Eurospine 2013, Liverpool, UK}, booktitle = {Pre-meeting SpineFX, Eurospine 2013, Liverpool, UK}, language = {en} } @inproceedings{PutzerPenzkoferEhrlichetal., author = {Putzer, Michael and Penzkofer, Rainer and Ehrlich, Ingo and Rasmussen, John and Gebbeken, Norbert and Dendorfer, Sebastian}, title = {Musculoskeletal simulations to investigate the influence of vertebral geometrical parameters on lumbar spine loading}, series = {7th World Congress of Biomechanics, Boston, United States, 04/07/14 -11/07/14}, booktitle = {7th World Congress of Biomechanics, Boston, United States, 04/07/14 -11/07/14}, language = {de} } @techreport{PutzerRasmussenEhrlichetal., author = {Putzer, Michael and Rasmussen, John and Ehrlich, Ingo and Gebbeken, Norbert and Dendorfer, Sebastian}, title = {Muskuloskelettale Simulation zur Untersuchung des Einflusses geometrischer Parameter der Wirbelk{\"o}rper auf die Belastung der Lendenwirbels{\"a}ule}, series = {Forschungsbericht 2013 / Ostbayerische Technische Hochschule Regensburg}, journal = {Forschungsbericht 2013 / Ostbayerische Technische Hochschule Regensburg}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, pages = {60 -- 61}, language = {de} } @inproceedings{PutzerWeberDendorfer, author = {Putzer, Michael and Weber, Tim and Dendorfer, Sebastian}, title = {Design studies on hip prosthesis using patient specific data}, series = {Simpleware Users meeting, November 9th 2011, Bristol, UK}, booktitle = {Simpleware Users meeting, November 9th 2011, Bristol, UK}, language = {en} } @inproceedings{RasmussenBichlerChristensenetal., author = {Rasmussen, John and Bichler, R. and Christensen, Soeren Toerholm and Wirix-Speetjens, Roel and Dendorfer, Sebastian and Renkawitz, Tobias}, title = {Subject-specific Musculoskeletal Simulation of Hip Dislocation Risk in Activities of Daily Living}, series = {Proceedings of the 2011 ORS Annual Meeting, Long Beach, CA.}, booktitle = {Proceedings of the 2011 ORS Annual Meeting, Long Beach, CA.}, number = {Paper No. 306}, language = {en} } @article{ReichHornberger, author = {Reich, Sven and Hornberger, Helga}, title = {The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns}, series = {Journal of Prosthetic Dentistry}, volume = {88}, journal = {Journal of Prosthetic Dentistry}, number = {1}, pages = {44 -- 49}, abstract = {Statement of problems: Computer-aided design/computer-assisted machining systems offer the possibility of fabricating restorations from one machinable ceramic block. Whether multishaded blocks improve esthetic results and are a viable alternative to individually stained ceramics has not been fully determined. Purpose: The aim of this investigation was to examine the effect of multishaded blocks on the esthetic appearance of all-ceramic CEREC crowns and compare these crowns with single-shade and stained restorations. Material and methods: Ten subjects were included in this study. For each subject, 6 different crowns were milled with the use of a CEREC machine. One crown was milled from each of the following machinable ceramic materials: CEREC Vitablocs Mark II in classic colors; Vitablocs Mark II in 3D-Master colors; Vitablocs Mark II in either classic or 3D-Master colors, with additional staining; Megadenta Bloxx multishaded; Mark II experimental multilayer; and an experimental multilayer leucite ceramic. Three independent examiners assessed the esthetic appearance of crowns fabricated to match each subject's anterior tooth shade. A scale of 1 to 6 was used to score the shade match and esthetic adaptation of each crown, with 1 representing excellent characteristics and 3.5 serving as the threshold for clinical acceptability. The examiners' scores were averaged, and the mean values were analyzed with the Wilcoxon signed rank test (P 87\% in both groups. There was a significant difference between the navigated and the conventional groups' Harris hip scores six weeks after surgery (p = 0.010). There were no significant differences with respect to any clinical outcome at six months and one year of follow-up. The navigated 'femur-first' technique improves the potential ROM for ADL without prosthetic impingement, although there was no observed clinical difference between the two treatment groups.}, subject = {H{\"u}ftgelenkprothese}, language = {en} } @article{RenkawitzWeberDullienetal., author = {Renkawitz, Tobias and Weber, Tim A. and Dullien, Silvia and Woerner, Michael and Dendorfer, Sebastian and Grifka, Joachim and Weber, Markus}, title = {Leg length and offset differences above 5 mm after total hip arthroplasty are associated with altered gait kinematics}, series = {Gait \& Posture}, volume = {vol. 49}, journal = {Gait \& Posture}, doi = {10.1016/j.gaitpost.2016.07.011}, pages = {196 -- 201}, abstract = {We aimed to investigate the relationship between postoperative leg length/offset (LL/OS) reconstruction and gait performance after total hip arthroplasty (THA). In the course of a prospective randomized controlled trial, 60 patients with unilateral hip arthrosis received cementless THA through a minimally-invasive anterolateral surgical approach. One year post-operatively, LL and global OS restoration were analyzed and compared to the contralateral hip on AP pelvic radiographs. The combined postoperative limb length/OS reconstruction of the operated hip was categorized as restored (within 5 mm) or non-restored (more than 5 mm reduction or more than 5 mm increment). The acetabular component inclination, anteversion and femoral component anteversion were evaluated using CT scans of the pelvis and the femur. 3D gait analysis of the lower extremity and patient related outcome measures (HHS, HOOS, EQ-5D) were obtained pre-operatively, six months and twelve months post-operatively by an observer blinded to radiographic results. Component position of cup and stem was comparable between the restored and non-restored group. Combined LL and OS restoration within 5 mm resulted in higher Froude number (p < 0.001), normalized walking speed (p < 0.001) and hip range-of-motion (ROM) (p = 0.004) during gait twelve months postoperatively, whereas gait symmetry was comparable regardless of LL and OS reconstruction at both examinations. Clinical scores did not show any relevant association between the accuracy of LL or OS reconstruction and gait six/twelve months after THA. In summary, postoperative LL/OS discrepancies larger than 5 mm relate to unphysiological gait kinematics within the first year after THA. DRKS00000739, German Clinical Trials Register.}, language = {en} } @inproceedings{RobieDendorferRasmussenetal., author = {Robie, Bruce and Dendorfer, Sebastian and Rasmussen, John and Christensen, Soeren Toerholm}, title = {Axial Rotation Requires Greatest Load in Multifidus Muscle - Potential Association with Low Back Pain?}, series = {Annual Meeting of the AANS/CNS Section on Disorders of the Spine and Peripheral Nerves, 2011, Phoenix, Arizona}, booktitle = {Annual Meeting of the AANS/CNS Section on Disorders of the Spine and Peripheral Nerves, 2011, Phoenix, Arizona}, language = {en} } @inproceedings{RobieRasmussenChristensenetal., author = {Robie, Bruce and Rasmussen, John and Christensen, Soeren Toerholm and Dendorfer, Sebastian}, title = {Herniation Induces 55\% Increase in Load of Key Stabilizing Muscle - Impact on Herniation Treatment Devices?}, series = {Spine Arthoplasty Society Meeting, New Orleans, 2010}, booktitle = {Spine Arthoplasty Society Meeting, New Orleans, 2010}, language = {en} } @article{RoldanMoralisDendorferetal., author = {Rold{\´a}n, J.C. and Moralis, A. and Dendorfer, Sebastian and Witte, J. and Reicheneder, C.}, title = {Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage}, series = {The Journal of craniofacial surgery}, volume = {22}, journal = {The Journal of craniofacial surgery}, number = {6}, doi = {10.1097/SCS.0b013e318231fc8d}, pages = {2384 -- 2386}, abstract = {A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry.}, subject = {Mund-Kiefer-Gesichts-Chirurgie}, language = {en} }