@inproceedings{WeberRenkawitzBulstraetal., author = {Weber, Tim and Renkawitz, Tobias and Bulstra, Sjoerd K. and Grifka, Joachim and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Biomechanics of computer-assisted vs. conventional THR after one year follow up}, series = {XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015}, booktitle = {XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015}, language = {en} } @inproceedings{IgnasiakDendorferFerguson, author = {Ignasiak, Dominika and Dendorfer, Sebastian and Ferguson, Stephen J.}, title = {Thoracolumbar spine model with articulated rigcage for the prediction of dynamic spinal loading}, series = {International Workshop on Spine Loading and Deformation: From Loading to Recovery, 2-4 July 2015, Julius Wolff Institute, Charit{\´e}-Universitatsmedizin Berlin, Germany}, booktitle = {International Workshop on Spine Loading and Deformation: From Loading to Recovery, 2-4 July 2015, Julius Wolff Institute, Charit{\´e}-Universitatsmedizin Berlin, Germany}, language = {en} } @inproceedings{WeberDendorferBulstraetal., author = {Weber, Tim and Dendorfer, Sebastian and Bulstra, Sjoerd K. and Grifka, Joachim and Verkerke, Gijsbertus Jacob and Renkawitz, Tim}, title = {Navigated Femur First Total Hip Arthroplasty leads to improved Biomechanical Outcome after surgery}, series = {ORS annual meeting, Las Vegas, USA, 2015}, booktitle = {ORS annual meeting, Las Vegas, USA, 2015}, language = {en} } @inproceedings{BillingGoetzWeberetal., author = {Billing, A. and G{\"o}tz, J. and Weber, Tim and Dendorfer, Sebastian}, title = {Positionsanalyse von winkelstabilen Plattenosteosynthesesystemen zur Versorgung von Metatarsalfrakturen mit Hilfe von patientenspezifischen biomechanischen Modellen}, series = {Vereinigung S{\"u}ddeutscher Orthop{\"a}den und Unfallchirurgen Jahrestagung 2015, Baden-Baden, Germany}, booktitle = {Vereinigung S{\"u}ddeutscher Orthop{\"a}den und Unfallchirurgen Jahrestagung 2015, Baden-Baden, Germany}, language = {de} } @inproceedings{WeberStezowskiDullienetal., author = {Weber, Tim and Stezowski, P. and Dullien, Silvia and Putzer, Michael and Dendorfer, Sebastian}, title = {Eine biomechanische Bewertung verschiedener Belastungsszenarien nach Implantierung einer H{\"u}ft-Totalendoprothese}, series = {GAMMA Workshop, Hannover, 2012}, booktitle = {GAMMA Workshop, Hannover, 2012}, language = {de} } @inproceedings{SuessKubowitschVerkerkeetal., author = {S{\"u}ß, Franz and Kubowitsch, Simone and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Investigation of cognitive stress induced changes in spinal disc forces due to altered kinematics and muscle activity}, series = {World Congress Biomechanics, Dublin, 2018}, booktitle = {World Congress Biomechanics, Dublin, 2018}, language = {en} } @inproceedings{SpreiterGalibarovDendorferetal., author = {Spreiter, G. and Galibarov, Pavel E. and Dendorfer, Sebastian and Ferguson, Stephen J.}, title = {Influence of kyphosis on spinal loading}, series = {10th International Symposium Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) Meeting, 11. - 14. April 2012, Berlin}, booktitle = {10th International Symposium Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) Meeting, 11. - 14. April 2012, Berlin}, language = {en} } @inproceedings{PutzerDendorfer, author = {Putzer, Michael and Dendorfer, Sebastian}, title = {Sensitivity of lumbar spine loading to anatomical parameters}, series = {International Workshop on Spine Loading and Deformation: From Loading to Recovery, 2-4 July 2015, Julius Wolff Institute, Charit{\´e}-Universitatsmedizin Berlin, Germany}, booktitle = {International Workshop on Spine Loading and Deformation: From Loading to Recovery, 2-4 July 2015, Julius Wolff Institute, Charit{\´e}-Universitatsmedizin Berlin, Germany}, language = {en} } @inproceedings{KubowitschDendorfer, author = {Kubowitsch, Simone and Dendorfer, Sebastian}, title = {Psychologie und Biomechanik - Integrierte Betrachtung von Muskelrekrutierung}, series = {Jahrestagung der Deutschen Gesellschaft f{\"u}r Biofeedback e. V., Regensburg, 2018}, booktitle = {Jahrestagung der Deutschen Gesellschaft f{\"u}r Biofeedback e. V., Regensburg, 2018}, language = {de} } @misc{AuerReinkerDendorfer, author = {Auer, Simon and Reinker, Lukas and Dendorfer, Sebastian}, title = {Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion}, series = {26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy}, journal = {26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy}, address = {Milan}, pages = {8}, abstract = {Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements.}, language = {en} } @article{VisscherWyssSinghetal., author = {Visscher, Rosa and Wyss, C. and Singh, Navrag B. and Taylor, William R. and Dendorfer, Sebastian and Rutz, E. and Brunner, Reinald}, title = {Influence of TAL-TATS surgery on energy production of Tricepts Surae - A musculoskeletal modeling evaluation}, series = {Gait \& Posture}, volume = {81}, journal = {Gait \& Posture}, number = {Suppl. 1}, publisher = {Elsevier}, doi = {10.1016/j.gaitpost.2020.08.090}, pages = {381 -- 382}, language = {en} } @inproceedings{PenzkoferGrechenigKujatetal., author = {Penzkofer, Rainer and Grechenig, S. and Kujat, Richard and Angele, Peter and Dendorfer, Sebastian}, title = {Biomechanical comparison of the dorsal femur condyles and the iliac crest in terms of failure behavior}, series = {XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015}, booktitle = {XXV Congress of the International Society of Biomechanics, Glasgow, UK, 12th-16th July 2015}, language = {en} } @inproceedings{StrieglKujatDendorfer, author = {Striegl, B. and Kujat, Richard and Dendorfer, Sebastian}, title = {Quantitative analysis of cartilage surface by confocal laser scanning microscopy}, series = {Biomedizinische Technik}, volume = {59}, booktitle = {Biomedizinische Technik}, number = {s1-A}, doi = {10.1515/bmt-2014-4012}, pages = {24}, language = {en} } @inproceedings{WeberDendorferBulstraetal., author = {Weber, Tim and Dendorfer, Sebastian and Bulstra, Sjoerd K. and Verkerke, Gijsbertus Jacob and Renkawitz, Tobias}, title = {Musculoskeletal modeling for orthopedic surgery - Applications and chances}, series = {Orthopedics meets Engineering, Regensburg, 2015}, booktitle = {Orthopedics meets Engineering, Regensburg, 2015}, language = {en} } @inproceedings{PutzerWeberDendorfer, author = {Putzer, Michael and Weber, Tim and Dendorfer, Sebastian}, title = {Design studies on hip prosthesis using patient specific data}, series = {Simpleware Users meeting, November 9th 2011, Bristol, UK}, booktitle = {Simpleware Users meeting, November 9th 2011, Bristol, UK}, language = {en} } @inproceedings{SuessPutzerDendorfer, author = {S{\"u}ß, Franz and Putzer, Michael and Dendorfer, Sebastian}, title = {Numerische und experimentelle Untersuchungen an der Wirbels{\"a}ule}, series = {Forschungssymposium Bad Abbach, Germany, 2015}, booktitle = {Forschungssymposium Bad Abbach, Germany, 2015}, language = {de} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {Mechanobiology - Impact on regeneration and degradation}, series = {Translations in Regenerative Medicine, TIRM and FIFA Symposium, Regensburg, 2015}, booktitle = {Translations in Regenerative Medicine, TIRM and FIFA Symposium, Regensburg, 2015}, language = {en} } @inproceedings{EnglertMuellerDendorfer, author = {Englert, Carsten and M{\"u}ller, F. and Dendorfer, Sebastian}, title = {Einfluss der Muskelkr{\"a}fte, des Bewegungsausmaßes und der Bruchform auf die Kraft{\"u}bertragung des Implantat-Knochenverbundes am Beispiel der Claviculafraktur im mittleren Drittel}, series = {17. Jahreskongress der Deutschen Vereinigung f{\"u}r Schulter- und Ellenbogenchirurgie (DVSE), Rosenheim 2010}, booktitle = {17. Jahreskongress der Deutschen Vereinigung f{\"u}r Schulter- und Ellenbogenchirurgie (DVSE), Rosenheim 2010}, abstract = {Fragestellung Es soll in dieser Computersimulationsstudie untersucht werden, wie der Osteosyntheseverbund Platte mit Schrauben im Verbund mit einer im mittleren Drittel gebrochenen Clavicula durch das Bewegungsausmaß in vivo belastet ist. Was sind die grundlegenden Kr{\"a}fte die auf Clavicula und Implantat wirken und welchen Einfl uss hat die Bruchform. Methodik Die Muskel- und Gelenkkr{\"a}fte sowie die Belastung des Implantatverbundes wurden mit einer muskuloskelletalen Simulationssoftware (AnyBody Technology, V.4) berechnet. Hierf{\"u}r wurden mit einem komplexen Model des menschlichen K{\"o}rpers folgende Bewegungen analysiert: eine Flexion von 160° und Abduktion 160° mit einem Gewicht von 2 kg in der Hand. Aus CT-Patientendaten wurden zwei dreidimensionale Modelle des Clavicula-Implantat Verbundes gebildet, die sich in der Frakturform unterscheiden (Querfraktur und vertikale Fraktur). In beiden Modellen wurde eine Claviculaosteosynthese in superiorer Position mit einer 6 Loch LCP mit 2 Schrauben pro Hauptfragment verwendet. Die Materialeigenschaften wurden aus der Dichte des Materials sowie aus Literaturdaten verwendet. Die Muskel- und Gelenkkr{\"a}fte aus der muskuloskelletalen Berechnung wurden auf das Finite Elemente Modell {\"u}bertragen und die Spannungen und Dehnungen des Implantat-Knochenverbundes wurden berechnet. Ergebnisse Es zeigte sich, dass die simulierte in vivo Belastung stark abh{\"a}ngig vom Flexionswinkel ist. Das Implantat ist in der superioren Lage auf Biegung belastet, welche maximale Werte im {\"U}berschulterniveau erreicht. Die Bruchform mit anatomischer Reposition und Kontakt der Hauptfragmente zueinander f{\"u}hrt zu einer deutlichen Entlastung des Osteosyntheseverbundes im Vergleich zu einer Bruchform mit vertikaler Fraktur. Schlussfolgerung Aus den Analysen ist eine Positionierung der Plattenosteosynthese f{\"u}r die im mittleren Drittel frakturierte Clavicula in anterior-superiorer Lage w{\"u}nschenswert. Die anatomische Reposition entlastet den Osteosyntheseverbund und sollte m{\"o}glichst erreicht werden. Die Nachbehandlung sollte ein Bewegungsausmaß f{\"u}r den Arm f{\"u}r 4 Wochen f{\"u}r einfache Bruchformen auf 70° Flexion und Abduktion limitieren und f{\"u}r komplexe Bruchformen diese Limitierung ausgedehnt werden.}, language = {de} } @article{AuerKrutschRenkawitzetal., author = {Auer, Simon and Krutsch, Werner and Renkawitz, Tobias and Kubowitsch, Simone and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Kognitiver Stress f{\"u}hrt zu unphysiologisch erh{\"o}hten Kniebelastungen im Profifußball}, series = {Sports Orthopaedics and Traumatology}, volume = {36}, journal = {Sports Orthopaedics and Traumatology}, number = {2}, publisher = {Elsevier}, doi = {10.1016/j.orthtr.2020.04.122}, pages = {202 -- 203}, language = {de} } @inproceedings{AndersendeZeeDendorferetal., author = {Andersen, Michael Skipper and de Zee, Mark and Dendorfer, Sebastian and MacWilliams, Bruce and Rasmussen, John}, title = {Validation of a detailed lower extremity model based on the Klein Horsman data set}, series = {Proceedings of the 12th International Symposium on Computer Simulation in Biomechanics (ISB 2009), July 2nd - 4th 2009, Cape Town, South Africa}, booktitle = {Proceedings of the 12th International Symposium on Computer Simulation in Biomechanics (ISB 2009), July 2nd - 4th 2009, Cape Town, South Africa}, pages = {27 -- 28}, language = {en} } @inproceedings{DendorferRasmussenChristensenetal., author = {Dendorfer, Sebastian and Rasmussen, John and Christensen, Soeren Toerholm and Robie, Bruce}, title = {The Effect of Spinal Disc Herniation on Multifidus Muscles}, series = {56th Orthopaedic Research Society Meeting, New Orleans, USA, 2010}, booktitle = {56th Orthopaedic Research Society Meeting, New Orleans, USA, 2010}, language = {en} } @misc{SuessMelznerDendorfer, author = {Suess, Franz and Melzner, Maximilian and Dendorfer, Sebastian}, title = {Towards Ergonomic working - machine learning algorithms and musculoskeletal modeling}, series = {RIM 2021, 13th International Scientific Conference on Manufacturing Engineering, 29 Sept. - 1 Oct 2021, Sarajevo, Bosnia and Herzegovina}, journal = {RIM 2021, 13th International Scientific Conference on Manufacturing Engineering, 29 Sept. - 1 Oct 2021, Sarajevo, Bosnia and Herzegovina}, language = {en} } @inproceedings{HammerDendorfer, author = {Hammer, Joachim and Dendorfer, Sebastian}, title = {Cyclic loading and microstructure of cancellous bone}, series = {Journal of Biomechanics}, volume = {41}, booktitle = {Journal of Biomechanics}, number = {Suppl. 1, July 2008}, doi = {10.1016/S0021-9290(08)70409-3}, pages = {S410}, language = {en} } @inproceedings{RobieRasmussenChristensenetal., author = {Robie, Bruce and Rasmussen, John and Christensen, Soeren Toerholm and Dendorfer, Sebastian}, title = {Herniation Induces 55\% Increase in Load of Key Stabilizing Muscle - Impact on Herniation Treatment Devices?}, series = {Spine Arthoplasty Society Meeting, New Orleans, 2010}, booktitle = {Spine Arthoplasty Society Meeting, New Orleans, 2010}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {How much iron to pump? The determination of muscle forces for activities of daily living}, series = {DGU, Berlin, 2008}, booktitle = {DGU, Berlin, 2008}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {Biomechanical evaluation and optimisation of countermeasure exercises}, series = {ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009}, booktitle = {ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009}, language = {en} } @inproceedings{DendorferCarbesRasmussen, author = {Dendorfer, Sebastian and Carbes, S. and Rasmussen, John}, title = {The influence of muscle forces on biomechanical fracture fixation simulations - from in-vivo forces to tissue strains}, series = {World Congress on Medical Physics and Biomedical Engineering, 7 - 12, 2009, Munich}, booktitle = {World Congress on Medical Physics and Biomedical Engineering, 7 - 12, 2009, Munich}, language = {en} } @inproceedings{DendorferRasmussen, author = {Dendorfer, Sebastian and Rasmussen, John}, title = {The influence of in-vivo muscle forces on the stress distribution in a vertebral body during activities of daily living}, series = {Eurospine Warsaw, Poland 2009}, booktitle = {Eurospine Warsaw, Poland 2009}, language = {en} } @inproceedings{DendorferEnglert, author = {Dendorfer, Sebastian and Englert, Carsten}, title = {Forces on a clavicles midshaft fracture and influence of fracture type}, series = {AO Symposium, Regensburg, 2009}, booktitle = {AO Symposium, Regensburg, 2009}, language = {en} } @article{WiesentSchultheissLullaetal., author = {Wiesent, Lisa and Schultheiß, Ulrich and Lulla, Philipp and Noster, Ulf and Schratzenstaller, Thomas and Schmid, Christof and Nonn, Aida and Spear, Ashley}, title = {Computational analysis of the effects of geometric irregularities and post-processing steps on the mechanical behavior of additively manufactured 316L stainless steel stents}, series = {PLoS ONE}, volume = {15}, journal = {PLoS ONE}, number = {12}, publisher = {PLOS}, doi = {10.1371/journal.pone.0244463}, pages = {1 -- 30}, abstract = {Advances in additive manufacturing enable the production of tailored lattice structures and thus, in principle, coronary stents. This study investigates the effects of process-related irregularities, heat and surface treatment on the morphology, mechanical response, and expansion behavior of 316L stainless steel stents produced by laser powder bed fusion and provides a methodological approach for their numerical evaluation. A combined experimental and computational framework is used, based on both actual and computationally reconstructed laser powder bed fused stents. Process-related morphological deviations between the as-designed and actual laser powder bed fused stents were observed, resulting in a diameter increase by a factor of 2-2.6 for the stents without surface treatment and 1.3-2 for the electropolished stent compared to the as-designed stent. Thus, due to the increased geometrically induced stiffness, the laser powder bed fused stents in the as-built (7.11 ± 0.63 N) or the heat treated condition (5.87 ± 0.49 N) showed increased radial forces when compressed between two plates. After electropolishing, the heat treated stents exhibited radial forces (2.38 ± 0.23 N) comparable to conventional metallic stents. The laser powder bed fused stents were further affected by the size effect, resulting in a reduced yield strength by 41\% in the as-built and by 59\% in the heat treated condition compared to the bulk material obtained from tensile tests. The presented numerical approach was successful in predicting the macroscopic mechanical response of the stents under compression. During deformation, increased stiffness and local stress concentration were observed within the laser powder bed fused stents. Subsequent numerical expansion analysis of the derived stent models within a previously verified numerical model of stent expansion showed that electropolished and heat treated laser powder bed fused stents can exhibit comparable expansion behavior to conventional stents. The findings from this work motivate future experimental/numerical studies to quantify threshold values of critical geometric irregularities, which could be used to establish design guidelines for laser powder bed fused stents/lattice structures.}, subject = {Koronarendoprothese}, language = {en} } @article{WesselyHausleiterMichaelisetal., author = {Wessely, Rainer and Hausleiter, J{\"o}rg and Michaelis, Cornelia and Jaschke, Birgit and Vogeser, Michael and Milz, Stefan and Behnisch, Boris and Schratzenstaller, Thomas and Renke-Gluszko, Magdalena and St{\"o}ver, Michael and Wintermantel, Erich and Kastrati, Adnan and Sch{\"o}mig, Albert}, title = {Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating}, series = {Arteriosclerosis, Thrombosis, and Vascular Biology}, volume = {25}, journal = {Arteriosclerosis, Thrombosis, and Vascular Biology}, number = {4}, issn = {1524-4636}, doi = {10.1161/01.ATV.0000157579.52566.ee}, pages = {748 -- 753}, abstract = {Objective The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. Methods and Results The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating of stents with a unique microporous surface allowing for individualizable, dose-adjustable, and multiple coatings with identical or various compounds, designated ISAR (individualizable drug-eluting stent system to abrogate restenosis). Stents were coated with 0.75\% rapamycin solution, and high-performance liquid chromatography (HPLC)-based determination of drug release profile indicated drug release for >21 days. Rapamycin-eluting microporous (REMP) stents implanted in porcine coronary arteries were safe. To determine the efficacy of REMP stents, this novel drug-eluting stent platform was compared with the standard sirolimus-eluting stent. At 30 days, in-stent neointima formation in porcine coronary arteries was similar in both groups, yielding a significant decrease of neointimal area and injury-dependent neointimal thickness compared with bare-metal stents. Conclusion The ISAR drug-eluting stent platform as a novel concept for stent coating allows for a safe, effective, on-site stent coating process, thus justifying further clinical evaluation to decrease in-stent restenosis in humans. In-stent neointima formation can be successfully attenuated by drug-eluting stents. We introduce a novel conceptual approach for stent-coating that allows for dose-adjustable, on-site stent coating process if desired with multiple compounds. Microporous stents coated with rapamycin proved safe and effective for the limitation of neointima formation in a porcine coronary stent model.}, language = {en} } @article{WiesentSchultheissSchmidetal., author = {Wiesent, Lisa and Schultheiss, Ulrich and Schmid, Christof and Schratzenstaller, Thomas and Nonn, Aida}, title = {Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning}, series = {PlOS One}, volume = {14}, journal = {PlOS One}, number = {10}, publisher = {PLOS}, doi = {10.1371/journal.pone.0224026}, pages = {1 -- 25}, abstract = {In-stent restenosis remains a major problem of arteriosclerosis treatment by stenting. Expansion-optimized stents could reduce this problem. With numerical simulations, stent designs/ expansion behaviours can be effectively analyzed. For reasons of efficiency, simplified models of balloon-expandable stents are often used, but their accuracy must be challenged due to insufficient experimental validation. In this work, a realistic stent life-cycle simulation has been performed including balloon folding, stent crimping and free expansion of the balloon-stent-system. The successful simulation and validation of two stent designs with homogenous and heterogeneous stent stiffness and an asymmetrically positioned stent on the balloon catheter confirm the universal applicability of the simulation approach. Dogboning ratio, as well as the final dimensions of the folded balloon, the crimped and expanded stent, correspond well to the experimental dimensions with only slight deviations. In contrast to the detailed stent life-cycle simulation, a displacement-controlled simulation can not predict the transient stent expansion, but is suitable to reproduce the final expanded stent shape and the associated stress states. The detailed stent life-cycle simulation is thus essential for stent expansion analysis/optimization, whereas for reasons of computational efficiency, the displacement-controlled approach can be considered in the context of pure stress analysis.}, subject = {Stent}, language = {en} } @misc{KoeglerIsmailRusavyetal., author = {K{\"o}gler, Michael and Ismail, Khaled M. and Rusavy, Zdenek and Kalis, Vladimir and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Influence of bed height and stance on accoucheurs lower back and glenohumeral load during simulated childbirth}, series = {31st meeting of Czech Urogynaecological Society, Prague, 2022}, journal = {31st meeting of Czech Urogynaecological Society, Prague, 2022}, language = {en} } @article{ManarancheHornberger, author = {Manaranche, Claire and Hornberger, Helga}, title = {A proposal for the classification of dental alloys according to their resistance to corrosion}, series = {Dental Materials}, volume = {23}, journal = {Dental Materials}, number = {11}, doi = {10.1016/j.dental.2006.11.030}, pages = {1428 -- 1437}, abstract = {Objectives The purpose of this study was to establish a method to compare and classify dental alloys in relation to their resistance to corrosion. Methods Alloy samples and pure metal samples were prepared and tested in chemical and electrochemical corrosion according to ISO 10271. For electrochemical test, the rest potential versus time and a potentiodynamic scan were recorded. After chemical corrosion test, the ions released were analyzed by ICP (induced coupled plasma) spectroscopy. Results High gold alloys had a similar polarization curve than gold. The same effect was observed for Pd-base alloys, their curves were similar to the one of palladium. The ions released during chemical corrosion were non-precious metallic ions. Thereby Ni-Cr alloys were found to release the most ions. Au-Pt alloys showed the highest release of ions compared with other precious alloys but low compared with Ni-Cr. Electrochemical corrosion was more aggressive than chemical corrosion and every type of elements was etched, the higher the precious metal content, the higher the resistance to corrosion of the alloy. Discussion Using the recorded data, a classification system for electrochemical corrosion was developed and discussed to judge the results. Hereby were gold and zinc used as reference materials. The applied classification system defines five classes and it is proposed that alloys of class V are not acceptable. For chemical corrosion resistance, three classes were distinguished according to the quantity of metallic ions released and it is proposed that class III (100-1000 μg/cm2 week) is not acceptable. Palladium and Pd-base alloys showed a higher electrochemical and chemical corrosion resistance than gold.}, language = {en} } @article{DendorferMelzner, author = {Dendorfer, Sebastian and Melzner, Maximilian}, title = {R{\"u}ckenschmerzen bei Geburtshelfer:innen. Die Haltung macht's.}, series = {Deutsche Hebammen-Zeitschrift}, volume = {74}, journal = {Deutsche Hebammen-Zeitschrift}, number = {11}, publisher = {Staude}, address = {Hannover}, issn = {0012-026X}, pages = {60 -- 62}, abstract = {F{\"u}r Mutter und Kind konnte das Risiko der Geburt durch die Weiterentwicklung der Medizin drastisch reduziert werden. Doch wie ist es um das Wohl derer bestellt, die die Geb{\"a}rende unterst{\"u}tzen? Eine Studie der Ostbayerischen Technischen Hochschule Regensburg hat sich mit den muskuloskelettalen Beschwerden von Geburtshelfer:innen auseinandergesetzt}, language = {de} } @article{KheiroddinSchoeberlAlthammeretal., author = {Kheiroddin, Parastoo and Sch{\"o}berl, Patricia and Althammer, Michael and Cibali, Ezgi and W{\"u}rfel, Thea and Wein, Hannah and Kulawik, Birgit and Buntrock-D{\"o}pke, Heike and Weigl, Eva and Gran, Silvia and Gr{\"u}ndl, Magdalena and Langguth, Jana and Lampl, Benedikt and Judex, Guido and Niggel, Jakob and Pagel, Philipp and Schratzenstaller, Thomas and Schneider-Brachert, Wulf and Gastiger, Susanne and Bodenschatz, Mona and Konrad, Maike and Levchuk, Artem and Roth, Cornelius and Sch{\"o}ner, David and Schneebauer, Florian and Rohrmanstorfer, Ren{\´e} and Burkovski, Andreas and Ambrosch, Andreas and Wagner, Thomas and Kabesch, Michael}, title = {Results of WICOVIR Gargle Pool PCR Testing in German Schools Based on the First 100,000 Tests}, series = {Frontiers in Pediatrics}, volume = {9}, journal = {Frontiers in Pediatrics}, editor = {Buonsenso, Danilo}, publisher = {frontiers}, issn = {2296-2360}, doi = {10.3389/fped.2021.721518}, abstract = {Background: Opening schools and keeping children safe from SARS-CoV-2 infections at the same time is urgently needed to protect children from direct and indirect consequences of the COVID-19 pandemic. To achieve this goal, a safe, efficient, and cost-effective SARS-CoV-2 testing system for schools in addition to standard hygiene measures is necessary. Methods: We implemented the screening WICOVIR concept for schools in the southeast of Germany, which is based on gargling at home, pooling of samples in schools, and assessment of SARS-CoV-2 by pool rRT-PCR, performed decentralized in numerous participating laboratories. Depooling was performed if pools were positive, and results were transmitted with software specifically developed for the project within a day. Here, we report the results after the first 13 weeks in the project. Findings: We developed and implemented the proof-of-concept test system within a pilot phase of 7 weeks based on almost 17,000 participants. After 6 weeks in the main phase of the project, we performed >100,000 tests in total, analyzed in 7,896 pools, identifying 19 cases in >100 participating schools. On average, positive children showed an individual CT value of 31 when identified in the pools. Up to 30 samples were pooled (mean 13) in general, based on school classes and attached school staff. All three participating laboratories detected positive samples reliably with their previously established rRT-PCR standard protocols. When self-administered antigen tests were performed concomitantly in positive cases, only one of these eight tests was positive, and when antigen tests performed after positive pool rRT-PCR results were already known were included, 3 out of 11 truly positive tests were also identified by antigen testing. After 3 weeks of repetitive WICOVIR testing twice weekly, the detection rate of positive children in that cohort decreased significantly from 0.042 to 0.012 (p = 0.008). Interpretation: Repeated gargle pool rRT-PCR testing can be implemented quickly in schools. It is an effective, valid, and well-received test system for schools, superior to antigen tests in sensitivity, acceptance, and costs.}, subject = {Covid-19}, language = {en} } @article{GeithNothdurfterHeimletal., author = {Geith, Markus A. and Nothdurfter, Laurenz and Heiml, Manuel and Agrafiotis, Emmanouil and Gruber, Markus and Sommer, Gerhard and Schratzenstaller, Thomas and Holzapfel, Gerhard A.}, title = {Quantifying stent-induced damage in coronary arteries by investigating mechanical and structural alterations}, series = {Acta Biomaterialia}, volume = {116}, journal = {Acta Biomaterialia}, number = {October}, publisher = {Elsevier}, doi = {10.1016/j.actbio.2020.08.016}, pages = {285 -- 301}, abstract = {Vascular damage develops with diverging severity during and after percutaneous coronary intervention with stent placement and is the prevailing stimulus for in-stent restenosis. Previous work has failed to link mechanical data obtained in a realistic in vivo or in vitro environment with data collected during imaging processes. We investigated whether specimens of porcine right coronary arteries soften when indented with a stent strut shaped structure, and if the softening results from damage mechanisms inside the fibrillar collagen structure. To simulate the multiaxial loading scenario of a stented coronary artery, we developed the testing device 'LAESIO' that can measure differences in the stress-stretch behavior of the arterial wall before and after the indentation of a strut-like stamp. The testing protocol was optimized according to preliminary experiments, more specifically equilibrium and relaxation tests. After chemical fixation of the specimens and subsequent tissue clearing, we performed three-dimensional surface and second-harmonic generation scans on the deformed specimens. We analyzed and correlated the mechanical response with structural parameters of high-affected tissue located next to the stamp indentation and low-affected tissue beyond the injured area. The results reveal that damage mechanisms, like tissue compression as well as softening, fiber dispersion, and the lesion extent, are direction-dependent, and the severity of them is linked to the strut orientation, indentation pressure, and position. The findings highlight the need for further investigations by applying the proposed methods to human coronary arteries. Additional data and insights might help to incorporate the observed damage mechanisms into material models for finite element analyses to perform more accurate simulations of stent-implantations.}, language = {en} } @inproceedings{WiesentGeithWagner, author = {Wiesent, Lisa and Geith, Markus A. and Wagner, Marcus}, title = {Simulation of Fluid-Structure Interaction between injection medium and balloon catheter using ICFD}, series = {11th European LS-DYNA Conference 2017, 9 - 11 May, Salzburg, Austria}, booktitle = {11th European LS-DYNA Conference 2017, 9 - 11 May, Salzburg, Austria}, isbn = {978-3981621549}, abstract = {Arteriosclerosis is a major health issue worldwide. While it is commonly treated by the implantation of an balloon-expandable stent, micro injuries may occur during stent deployment, and induce in-stent restenosis, whose consequence can be fatal. Studying this undesirable phenomenon is usually limited as experimental data is hard to obtain on ethical ground. Numerical simulation are performed to better understand this problem. To construct a more realistic simulation of a balloon-expandable stent, a partitioned strongly-coupled FSI simulation of the balloon deployment was set up using the ICFD solver of LS-DYNA, - a quite innovative approach. The complex balloon configuration as well as the interaction of the injection medium and the balloon structure was considered. The balloon structure consisting of shell elements was obtained from preliminary balloon folding and pleating simulations. The balloon consists of a flexible thin walled polyamide. The injection fluid is implemented using volume elements. Balloon deployment was initiated by a pressure boundary condition inducing a volume flow into the balloon. The initial feasibility analysis showed promising result including a continuous balloon deployment and a reasonable development of the fluid pressure and velocity field. However, applying this FSI approach to a more complex balloon structure led to a non convergent solution. The non-convergence could be mainly reduced to mechanical factors including the low wall thickness of the balloon (< 0.05 mm) and the flexibility of the polyamide. Further, the ICFD solver shows less accuracy concerning the FSI conditions when dealing with thin flexible structures as well as enclosed volumes. A shell thickness of 0.06 mm is believed to result in a convergent solution.}, subject = {Koronare Herzkrankheit}, language = {en} } @misc{WiesentHupkeBalketal., author = {Wiesent, Lisa and Hupke, Constantin and Balk, Christian and Schultheiss, Ulrich and Schratzenstaller, Thomas}, title = {Optimization of the cardiovascular stent design towards improved expansion behaviour and radial stiffness properties}, series = {Biomedizinische Technik}, volume = {63}, journal = {Biomedizinische Technik}, number = {s1}, doi = {10.1515/bmt-2018-6031}, abstract = {- Development of a FEA Tool for a realistic stent simulation - investigation on minor modification on the stent design on the expansion behaviour - analysis of three stent designs: classical stent design with pronounced dogbone effect, two modified stent design (non-dogbone-design)}, subject = {Kardiovaskul{\"a}res System}, language = {en} } @misc{GeithSwidergalSchratzenstalleretal., author = {Geith, Markus A. and Swidergal, Krzysztof and Schratzenstaller, Thomas and Holzapfel, Gerhard A. and Wagner, Marcus}, title = {Numerical analysis of stent delivery systems during pre- and intraoperative processes}, series = {15. Deutsches LS-DYNA Forum, 15.-17.10.2018, Bamberg}, journal = {15. Deutsches LS-DYNA Forum, 15.-17.10.2018, Bamberg}, language = {en} } @article{GeithSommerSchratzenstalleretal., author = {Geith, Markus A. and Sommer, Gerhard and Schratzenstaller, Thomas and Holzapfel, Gerhard A.}, title = {Biomechanical and structural quantification of vascular damage: A unique investigation of stent implantation}, series = {Artery Research}, volume = {20}, journal = {Artery Research}, number = {Issue C}, doi = {10.1016/j.artres.2017.10.025}, pages = {50}, language = {en} } @article{WiesentSpearNonn, author = {Wiesent, Lisa and Spear, Ashley and Nonn, Aida}, title = {Computational analysis of the effects of geometric irregularities on the interaction of an additively manufactured 316L stainless steel stent and a coronary artery}, series = {Journal of the Mechanical Behavior of Biomedical Materials}, volume = {125}, journal = {Journal of the Mechanical Behavior of Biomedical Materials}, publisher = {Elsevier}, issn = {1751-6161}, doi = {10.1016/j.jmbbm.2021.104878}, abstract = {Customized additively manufactured (laser powder bed fused (L-PBF)) stents could improve the treatment of complex lesions by enhancing stent-artery conformity. However, geometric irregularities inherent for L-PBF stents are expected to influence not only their mechanical behavior but also their interaction with the artery. In this study, the influence of geometrical irregularities on stent-artery interaction is evaluated within a numerical framework. Thus, computed arterial stresses induced by a reconstructed L-PBF stent model are compared to those induced by the intended stent model (also representing a stent geometry obtained from conventional manufacturing processes) and a modified CAD stent model that accounts for the increased strut thickness inherent for L-PBF stents. It was found that, similar to conventionally manufactured stents, arterial stresses are initially related to the basic stent design/topology, with the highest stresses occurring at the indentations of the stent struts. Compared to the stent CAD model, the L-PBF stent induces distinctly higher and more maximum volume stresses within the plaque and the arterial wall. In return, the modified CAD model overestimates the arterial stresses induced by the L-PBF stent due to its homogeneously increased strut thickness and thus its homogeneously increased geometric stiffness compared with the L-PBF stent. Therefore, the L-PBF-induced geometric irregularities must be explicitly considered when evaluating the L-PBF stent-induced stresses because the intended stent CAD model underestimates the arterial stresses, whereas the modified CAD model overestimates them. The arterial stresses induced by the L-PBF stent were still within the range of values reported for conventional stents in literature, suggesting that the use of L-PBF stents is conceivable in principle. However, because geometric irregularities, such as protruding features from the stent surface, could potentially damage the artery or lead to premature stent failure, further improvement of L-PBF stents is essential.}, language = {en} } @inproceedings{NonnKalwa, author = {Nonn, Aida and Kalwa, Christoph}, title = {Application of damage mechanics approach for crack propagation in pipeline}, series = {19th Biennial Joint Technical Meeting (JTM) on Pipeline Research, April 29 - May 3, 2013, Sydney, Australia}, booktitle = {19th Biennial Joint Technical Meeting (JTM) on Pipeline Research, April 29 - May 3, 2013, Sydney, Australia}, language = {en} } @inproceedings{SieglRiegerKovariketal., author = {Siegl, Marco and Rieger, David and Kov{\´a}r{\´i}k, Tom{\´a}š and Ehrlich, Ingo}, title = {Long-Term Behavior of Thermoplastics under UV Light tested by a self-build Device}, series = {3. OTH-Clusterkonferenz, 13. April 2018, Weiden, Tagungsband; Festschrift, 5 Jahre OTH-Verbund}, booktitle = {3. OTH-Clusterkonferenz, 13. April 2018, Weiden, Tagungsband; Festschrift, 5 Jahre OTH-Verbund}, organization = {Ostbayerische Technische Hochschule}, pages = {118 -- 122}, abstract = {This article presents first results of artificial aging experi-ments by ultraviolet (UV) irradiation on thermoplasticmaterials conducted as an intent of the research project Thermoplastic Composite Structures (TheCoS) in colla-boration of the Ostbayerische Technische Hochschule(OTH) Regensburg and the University of West Bohemia(UWB) in Pilsen as part of a cross-border cooperation. In technical applications, thermoplastic materials are oftenaffected by aging and a related deterioration of the mechanical properties. Therefore, it is necessary to identifythe aging behavior of thermoplastic materials. For this,experiments were performed for three thermoplasticmaterials, namely polypropylene (PP), ultra high mole -cular weight polyethylene (UHMWPE) and high impactstrength polystyrene (HIPS). For these experiments, a UV chamber was constructed according to the internationalstandard EN ISO 4892-3 for simulation of exposurebehind window glass. The results are evaluated by testing the flexural strength and the dynamic mechanicalresponse after a selected period of time under UV lightand then compared to untreated test specimens.}, language = {en} } @incollection{SinghCapanni, author = {Singh, Max Diamond and Capanni, Felix}, title = {Medizintechnik-Spin-offs aus der Hochschule - Ein Prozessbeispiel}, series = {Entrepreneurship im Gesundheitswesen II}, booktitle = {Entrepreneurship im Gesundheitswesen II}, editor = {Pfannstiel Mario A., and Da-Cruz, Patrick and Rasche, Christoph}, publisher = {Springer Gabler}, address = {Wiesbaden}, isbn = {978-3-658-14781-5}, abstract = {Die Aufmerksamkeit f{\"u}r Unternehmensgr{\"u}ndungen hat in den letzten Jahren extrem zugenommen. Grunds{\"a}tzlich muss ein Start-up in einem kompetitiven Umfeld erfolgreich sein, um bestehen zu k{\"o}nnen. Der Weg dorthin wird maßgeblich beeinflusst durch Planung und finanzielle Ressourcen, die die Gr{\"u}nder bereitstellen m{\"u}ssen. In der Medizinprodukteindustrie kommen zus{\"a}tzlich große H{\"u}rden hinzu, die u. a. einen kurzen Produktlebenszyklus, lange Projektlaufzeiten, aufwendige klinische Studien und aktuell neue gesetzliche Verordnungen betreffen. Dieser Beitrag konzentriert sich zun{\"a}chst auf m{\"o}gliche F{\"o}rdermittel und Beratung von Start-up-Projekten aus dem Hochschulbereich. Aus einer Analyse derzeit existierender Gr{\"u}nderwettbewerbe im Hinblick auf das Gesundheitswesen werden dem Leser entsprechende Adressen zum Einwerben von F{\"o}rdermitteln geliefert. Dar{\"u}ber hinaus wird ein Pilot-Prozess vorgestellt, wie eine Ausgr{\"u}ndungsberatung an der Hochschule Ulm im Studiengang Medizintechnik derzeit verl{\"a}uft. Dies kann m{\"o}glicherweise ein Ankn{\"u}pfungspunkt f{\"u}r eine zuk{\"u}nftige Institutionalisierung von Spin-off-Vorhaben aus dem Hochschulbereich sein.}, language = {de} } @incollection{Singh, author = {Singh, Max Diamond}, title = {Produktmanagement in der Medizintechnik}, series = {Medizinprodukte Management}, booktitle = {Medizinprodukte Management}, editor = {Schwegel, Philipp and Da-Cruz, Patrick and Hemel, Ulrich and Oberender, Peter}, publisher = {PCO-Verlag}, address = {Bayreuth}, isbn = {978-3-941678-47-7}, pages = {148 -- 161}, abstract = {Das Management in der Medizinprodukteindustrie steht vor vielf{\"a}ltigen Herausforderungen. So sinken einerseits die Produktpreise, anderseits wird auch f{\"u}r die kommenden Jahre in vielen Segmenten ein Mengenwachstum erwartet. Dies stellt die internen Prozesse, vom Customer Service bis hin zur Forschung \& Entwicklung, auf den Pr{\"u}fstand. Die Entscheidungstr{\"a}ger auf Kundenseite ver{\"a}ndern sich, weg vom Produktanwender hin zu professionellen Einkaufsgemeinschaften mit immer gr{\"o}ßerer Verhandlungsmacht. Der hohe Internationalisierungsgrad der Unternehmen f{\"u}hrt zu einer steigenden Komplexit{\"a}t bei der Implementierung von Marketing-, Vertriebs- und Produktentwicklungsstrategien auf L{\"a}nderebene. Dar{\"u}ber hinaus werden zunehmend neue Gesch{\"a}ftsmodelle mit hohem Dienstleistungsanteil entwickelt, die mit der traditionellen Lieferantenrolle wenig zu tun haben und von Managern eine neue F{\"a}higkeiten f{\"u}r die Umsetzung erfordern. Die Autoren des Sammelbands greifen die genannten Herausforderungen auf und bieten mit ihren Beitr{\"a}gen L{\"o}sungsans{\"a}tze, die sowohl f{\"u}r Manager im Medizinprodukteunternehmen als auch f{\"u}r Wissenschaftler und Studierende relevant sind.}, language = {de} } @article{LazarevRiabokonHalleretal., author = {Lazarev, I. A. and Riabokon, P. V. and Haller, M. and Dendorfer, Sebastian}, title = {Effect of the Displacement of Calcaneal Bone Peripheral Fragment in its Fracture on the Function of the Three-Headed Calf Muscle}, series = {TRAUMA}, volume = {16}, journal = {TRAUMA}, number = {2}, publisher = {Zaslavsky}, doi = {10.22141/1608-1706.2.16.2015.80247}, pages = {20 -- 24}, abstract = {In the structure of musculoskeletal injuries, calcaneal fractures account for up to 4 \% of all skeletal fractures and up to 60 \% of hindfoot fractures. The effect of the displacement of the peripheral fragment of the calcaneus on the calf muscles's reaction forces at the time of the adoption of the simplified squatting position was investigated by modeling in AnyBody Modeling System 6.0 software. M.gastrocnemius (lateralis et medialis) in the initial phase of motion in all variants of the peripheral fragment displacement did not develop sufficient muscular effort in comparison to the intact calcaneus. M.soleus medialis et lateralis showed significant increase in muscle activity rates in the initial phase of motion (41.87 ± 1.90 H and 52.07 ± 2.10 H) before reaching its maximum values, as compared with those of the intact calcaneus. In the final phase of the movement, upon muscle reaches its maximum length, muscular strength indicators of the m.soleus returned to their original values or were significantly below them. The decline in muscle strength was due to shortening of the moment arm or muscle excursion in case of convergence of muscle attachment points. When the peripheral fragment is displaced, due to putting down the heel to the surface of the support in terms of anatomical muscle lengthening, it takes extra effort to achieve rest length and its maximum power. In all types of the displacement of the peripheral fragment, the function of three-headed calf muscle is disturbed with involvement of additional muscular effort and energy expenditure. This fact should motivate the surgeon on the need for accurate repositioning of bone fragments in calcaneal fractures with the displacement of the peripheral fragment.}, language = {en} } @article{DendorferMaierTayloretal., author = {Dendorfer, Sebastian and Maier, Hans J{\"u}rgen and Taylor, David and Hammer, Joachim}, title = {Anisotropy of the fatigue behaviour of cancellous bone}, series = {Journal of Biomechanics}, volume = {41}, journal = {Journal of Biomechanics}, number = {3}, doi = {10.1016/j.jbiomech.2007.09.037}, pages = {636 -- 641}, abstract = {The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions which are not aligned with the main physiological axis remains unclear. Furthermore site and species dependent relationships are not well described. In this study five different groups of trabecular bone, defined in terms of orientation, species and site were exposed to cyclic compression. In total, 108 fatigue tests were analysed. The lifetimes were found to decrease drastically when off-axis loads were applied. Additionally, species and site strongly affect fatigue lifetimes. Strains at failure were also found to be a function of orientation.}, subject = {Erm{\"u}dung}, language = {en} } @misc{AuerKrutschRenkawitzetal., author = {Auer, Simon and Krutsch, Werner and Renkawitz, Tobias and Kubowitsch, Simone and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Effect of mental demand on leg loading in highly dynamic motion}, series = {AnyBody online Webinar, Oct 2020}, journal = {AnyBody online Webinar, Oct 2020}, abstract = {Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.}, language = {en} } @techreport{PutzerRasmussenEhrlichetal., author = {Putzer, Michael and Rasmussen, John and Ehrlich, Ingo and Gebbeken, Norbert and Dendorfer, Sebastian}, title = {Muskuloskelettale Simulation zur Untersuchung des Einflusses geometrischer Parameter der Wirbelk{\"o}rper auf die Belastung der Lendenwirbels{\"a}ule}, series = {Forschungsbericht 2013 / Ostbayerische Technische Hochschule Regensburg}, journal = {Forschungsbericht 2013 / Ostbayerische Technische Hochschule Regensburg}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, pages = {60 -- 61}, language = {de} }