@inproceedings{HaumerKral, author = {Haumer, Anton and Kral, Christian}, title = {Motor Management of Permanent Magnet Synchronous Machines}, series = {Proceedings of the 9th International MODELICA Conference; September 3-5; 2012; Munich; Germany}, booktitle = {Proceedings of the 9th International MODELICA Conference; September 3-5; 2012; Munich; Germany}, editor = {Otter, Martin and Zimmer, Dirk}, publisher = {Link{\"o}ping University Electronic Press}, isbn = {978-91-7519-826-2}, issn = {1650-3686}, doi = {10.3384/ecp12076159}, pages = {159 -- 166}, abstract = {Two state-of-the-art machine designs are mainly used in recent electric and hybrid electric vehicles: asynchronous induction machines with squirrel cage which are robust but need a current component to excite the magnetic field; and permanent magnet synchronous machines which rely on somehow more sensible parts but the magnets are able to excite a magnetic field without current. However; if speed gets high enough to reach the field weakening range; for both machine the field oriented control has to prescribe a field current sufficient to reduce the field not to exceed the voltage limits of the stator circuit. Especially for the permanent magnet synchronous machine this paper investigates whether it is possible to determine an optimal field current for every operation point to minimize either total current consumption or losses.}, language = {en} } @inproceedings{KralHaumerBogomolovetal., author = {Kral, Christian and Haumer, Anton and Bogomolov, Maxim and Lomonova, Elena}, title = {Harmonic wave model of a permanent magnet synchronous machine for modeling partial demagnetization under short circuit conditions}, series = {2012 XXth International Conference on Electrical Machines (ICEM 2012) ; Marseille, France, 2 - 5 September 2012}, booktitle = {2012 XXth International Conference on Electrical Machines (ICEM 2012) ; Marseille, France, 2 - 5 September 2012}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4673-0142-8}, doi = {10.1109/ICElMach.2012.6349880}, pages = {295 -- 301}, abstract = {This paper proposes a multi domain physical model of permanent magnet synchronous machines, considering electrical, magnetic, thermal and mechanical effects. For each component of the model, the main wave as well as lower and higher harmonic wave components of the magnetic flux and the magnetic potential difference may be considered. The permanent magnets are modeled as discrete azimuthal segments in order to consider possible partial demagnetization effects. For each magnet segment a linearized temperature dependent B-H curve is considered. The main advantage of the presented model is that time transient operational behavior of a permanent magnet synchronous machine can be considered under various electrical, magnetic, thermal and mechanical conditions. The electromagnetic condition of surface magnet machine is compared with finite element analysis.}, language = {en} } @inproceedings{KralHaumerLee, author = {Kral, Christian and Haumer, Anton and Lee, Sang Bin}, title = {Robust thermal model for the estimation of rotor cage and stator winding temperatures of induction machines}, series = {2012 XXth International Conference on Electrical Machines ; Marseille, France, 02.- 05.09.2012}, booktitle = {2012 XXth International Conference on Electrical Machines ; Marseille, France, 02.- 05.09.2012}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4673-0142-8}, doi = {10.1109/ICElMach.2012.6350127}, pages = {1810 -- 1816}, abstract = {In this paper a new model for the estimation of the stator winding and rotor cage temperatures of induction machines is presented. This model can be used in series applications of machines operated under dynamic load conditions where stator and rotor temperature shall be monitored. The proposed model relies on a simplified lumped element thermal equivalent circuit model where the stator core temperature serves as input quantity. The great advantage of this model is that it covers ambient and cooling conditions inherently. This leads to great simplicity and robustness. The parametrization and validation of the model through experimental data is presented. Advantages, drawbacks and possible implementations are discussed.}, language = {en} } @inproceedings{KralHaumerLee, author = {Kral, Christian and Haumer, Anton and Lee, Sang Bin}, title = {Innovative thermal model for the estimation of permanent magnet and stator winding temperatures}, series = {2012 IEEE Energy Conversion Congress and Exposition (ECCE 2012) ; Raleigh, NC, USA 15.09.-20.09.2012}, booktitle = {2012 IEEE Energy Conversion Congress and Exposition (ECCE 2012) ; Raleigh, NC, USA 15.09.-20.09.2012}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4673-0803-8}, issn = {2329-3721}, doi = {10.1109/ECCE.2012.6342386}, pages = {2704 -- 2711}, abstract = {In this paper an innovative thermal model for the determination of the temperatures of the permanent magnets and stator windings is presented. This model relies on one temperature sensor located in the stator core of the machine. The estimated stator winding and permanent magnet temperatures are determined by a simplified thermal lumped element network model with only two time constants. Due to the structure of the model and the measured stator core temperature the proposed thermal model is very robust. Distortion of the cooling circuit are inherently sensed such that the model can be used for the online prediction of temperatures. Experimental results based on an interior permanent magnet synchronous machine are presented to validate the presented model.}, language = {en} } @techreport{MichaelSternerMareikeJentschUweHolzhammer, author = {Michael Sterner, and Mareike Jentsch, and Uwe Holzhammer,}, title = {Energiewirtschaftliche und {\"o}kologische Bewertung eines Windgas-Angebotes}, publisher = {Fraunhofer Institute for Energy Economics and Energy System Technology}, address = {Kassel}, doi = {10.13140/RG.2.2.25093.68328}, abstract = {In this technical report, (1) the benefits of the new technology for future energy supply are discussed, (2) the climate protection effect of wind gas is discussed, and (3) a reasonable use of wind energy for gas generation is analyzed. In particular, windgas in the heat market is discussed in the utilization cascade of wind energy. The new "power-to-gas" concept opens up completely new possibilities for the integration of renewable energies and for coupling the electricity and gas grids. The Sabatier process, which has been known for 100 years, was first developed for this purpose in 2008 under the leadership of the Center for Solar Energy and Hydrogen Research and Fraunhofer IWES (formerly ISET) with electrolysis to create the "power-to-gas" concept for energy storage. A first pilot plant was built by ZSW Stuttgart on behalf of SolarFuel in 2009. This plant proves the technical feasibility of the new technology. Renewable gas is stored, transported and used as required as control and reserve energy via reconversion, e.g. in combined cycle power plants. In this way, decentrally generated renewable electricity is converted into a CO2 -neutral energy carrier with high energy density. The key advantage of renewable methane is the use of existing infrastructure such as gas grids, gas storage and end-use equipment for the integration of renewable energy. Technologies for natural gas are state of the art and commercially available. Methane also has three times the energy density of hydrogen.}, language = {en} } @inproceedings{NonnKalwa, author = {Nonn, Aida and Kalwa, Christoph}, title = {The effect of microstructure, strain hardening and strain rate on the fracture behavior of high strength pipeline steels}, series = {2nd International Conference on Material Modelling (ICMM2), 31th August - 2nd September, 2011 at Mines Paris Tech, France}, booktitle = {2nd International Conference on Material Modelling (ICMM2), 31th August - 2nd September, 2011 at Mines Paris Tech, France}, language = {en} } @techreport{OPUS4-2062, title = {Energienutzungsplan f{\"u}r die Gemeinde Sinzing}, editor = {Neuleitner, Nikolaus and Steffens, Oliver}, organization = {Hochschule f{\"u}r ANgewandte Wissenschaften Regensburg}, language = {de} } @inproceedings{HongHyunKangetal., author = {Hong, Jongman and Hyun, Doosoo and Kang, Tae-june and Lee, Sang Bin and Kral, Christian and Haumer, Anton}, title = {Detection and classification of rotor demagnetization and eccentricity faults for PM synchronous motors}, series = {2011 IEEE Energy Conversion Congress and Exposition (ECCE 2011) : Energy conversion innovation for a clean energy future ; Phoenix, Arizona, USA, 17.-22.09.2011}, booktitle = {2011 IEEE Energy Conversion Congress and Exposition (ECCE 2011) : Energy conversion innovation for a clean energy future ; Phoenix, Arizona, USA, 17.-22.09.2011}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4577-0542-7}, issn = {2329-3721}, doi = {10.1109/ECCE.2011.6064103}, pages = {2512 -- 2519}, abstract = {Condition monitoring of rotor problems such as demagnetization and eccentricity in permanent magnet synchronous motors (PMSM) is essential for guaranteeing high motor performance, efficiency, and reliability. However, there are many limitations to the off-line and on-line methods currently used for PMSM rotor quality assessment. In this paper, an inverter-embedded technique for automated detection and classification of PMSM rotor faults is proposed as an alternative. The main concept is to use the inverter to perform a test whenever the motor is stopped, to detect rotor faults independent of operating conditions or load torque oscillations, which is not possible with motor current signature analysis (MCSA). The d-axis is excited with a dc+ac signal, and the variation in the inductance pattern due to the change in the degree of magnetic saturation caused by demagnetization or eccentricity is observed for fault detection. An experimental study on a 7.5kW PMSM verifies that demagnetization and eccentricity can be detected and classified independent of the load with high sensitivity.}, language = {en} } @inproceedings{HongLeeKraletal., author = {Hong, Jongman and Lee, Sang Bin and Kral, Christian and Haumer, Anton}, title = {Detection of airgap eccentricity for permanent magnet synchronous motors based on the d-axis inductance}, series = {8th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics \& Drives (SDEMPED), 2011 // 05. - 08.09.2011, Bologna, Italy}, booktitle = {8th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics \& Drives (SDEMPED), 2011 // 05. - 08.09.2011, Bologna, Italy}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-4244-9301-2}, doi = {10.1109/DEMPED.2011.6063651}, pages = {378 -- 384}, abstract = {The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous on-line monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance, L d , decreases with increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped, to measure L d for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An FE and experimental study on a 10hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability.}, language = {en} } @inproceedings{HaumerKral, author = {Haumer, Anton and Kral, Christian}, title = {Modeling a Mains connected PWM Converter with Voltage-Oriented Control}, series = {Proceedings of the 8th International Modelica Conference, Technical Univeristy, Dresden, Germany, 20.-22.03.2011}, booktitle = {Proceedings of the 8th International Modelica Conference, Technical Univeristy, Dresden, Germany, 20.-22.03.2011}, publisher = {Link{\"o}ping University Electronic Press}, doi = {10.3384/ecp11063388}, pages = {388 -- 397}, abstract = {The majority of industrial controlled induction machine drives are connected to the mains via a diode bridge. However; if reduction of harmonic currents and / or regenerative operation is desired; replacing the diode bridge by an active front-end (AFE) is required. This paper describes two models of an AFE: a power balance model disregarding switching effects; and an ideal switching model of a pulse width modulation (PWM) converter. Both models are controlled utilizing space phasors in a voltage oriented reference frame. Voltage oriented control (VOC) of the mains converter can be compared with field oriented control (FOC) of a machine converter. Design and parametrization of the main parts—synchronization with mains voltage; current controller and DC voltage controller—are described in detail. Additionally; simulation results proving the implementation and demonstrating possible investigations as well as an outlook on further enhancements are presented.}, language = {en} }