@inproceedings{GrauvoglKrabinskiStauderetal., author = {Grauvogl, Dominik and Krabinski, Jeffrey and Stauder, Peter and Hopfensperger, Bernhard and Gerling, Dieter}, title = {NVH Comparison of a Novel Wound Field Synchronous Machine with Magnetic Asymmetry with a PSM for a HV Electric Drive}, series = {2021 JSAE Annual Congress (Spring) Proceedings; online meeting (No.76-21)}, booktitle = {2021 JSAE Annual Congress (Spring) Proceedings; online meeting (No.76-21)}, publisher = {JSAE}, abstract = {This paper shows how magnetic noises can be reduced with a wound field synchronous machine (WFSM) with magnetic asymmetry compared to a permanent magnet synchronous machine (PSM), operating at base speed range and full load. In order to reproduce a real noise behavior, the two rotor types are operated in a complete electric drive unit (EDU) consisting of an electric motor, gearbox, inverter and overall housing. In the concept study, the noise characteristics of the two electric machines is evaluated and compared via mechanical finite element method (FEM) simulations using the equivalent radiated power (ERP) level and Campbell diagrams. Furthermore, it is shown that critical frequency orders can already be identified by the analysis of the magnetic force density from the electromagnetic design without computationally intensive ERP calculations. In this context, the ERP investigations have shown that the unique feature of the magnetically asymmetric WFSM is the reduction of the slot harmonics. At the current state of the art, the slot harmonics can only be reduced with a rotor skewing. The disadvantage of this is a reduction in performance and a more expensive production. It is also remarkable that the magnetic asymmetry reduces the slot harmonics more than the rotor skewing in the PSM. In addition, both machines are still considered with a short-pitched stator winding to optimize the overall noise level by reducing the 24th frequency order.}, subject = {Elektroantrieb}, language = {en} } @inproceedings{SteiningerGadererDawoud, author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal}, title = {Transient performance of a solar selective thermal insulation system}, series = {16th Advanced Building Skins Conference \& Expo, 21 - 22/10/2021, Bern, Switzerland}, booktitle = {16th Advanced Building Skins Conference \& Expo, 21 - 22/10/2021, Bern, Switzerland}, publisher = {Advanced Buidling Skins GmbH}, abstract = {A prototype of a thermal insulation system to offer high selectivity of the solar gain regarding the solar incidence angle (SATIS) was applied to a typical solid brick masonry for existing buildings in Germany. Light conducting elements (LCEs) inclined at 19 ° were incorporated in SATIS, which equals the average solar noon angle in southern Germany during winter. The entire wall construction was experimentally investigated in a differential climatic chamber test bench at four different irradiation angles according to a dynamic test procedure. In addition, a conventional wall construction (CWC) has been measured. At SATIS' design angle of 19 °, the SATIS wall construction shows a solar gain (SG) of 394.5 Wh/m², while the SG of the CWC amounts to only 25.4 Wh/m². The validated transient model of the SATIS wall construction showed that, at the end of the irradiation period of the dynamic test procedure (8 h), the solar heat penetrates to a depth of 253 mm and 111 mm inside the 385 mm thick brick wall masonry at the irradiation angles of 19 ° and 50 °, respectively. During the same time, the stored solar energy at 50 ° amounts to only 24.4 \% of that stored at 19 °.}, language = {en} } @article{BelyaevaKleppLemmeletal., author = {Belyaeva, Inna A. and Klepp, J{\"u}rgen and Lemmel, Hartmut and Shamonin (Chamonine), Mikhail}, title = {Feasibility of Probing the Filler Restructuring in Magnetoactive Elastomers by Ultra-Small-Angle Neutron Scattering}, series = {Applied Sciences}, volume = {11}, journal = {Applied Sciences}, number = {10}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/app11104470}, pages = {1 -- 9}, abstract = {Ultra-small-angle neutron scattering (USANS) experiments are reported on isotropic magnetoactive elastomer (MAE) samples with different concentrations of micrometer-sized iron particles in the presence of an in-plane magnetic field up to 350 mT. The effect of the magnetic field on the scattering curves is observed in the scattering vector range between 2.5 x 10(-5) and 1.85 x 10(-4) angstrom(-1). It is found that the neutron scattering depends on the magnetization history (hysteresis). The relation of the observed changes to the magnetic-field-induced restructuring of the filler particles is discussed. The perspectives of employing USANS for investigations of the internal microstructure and its changes in magnetic field are considered.}, language = {en} } @incollection{BauerGawlikSterneretal., author = {Bauer, Franz and Gawlik, Julia and Sterner, Michael and Hamacher, Thomas}, title = {{\"U}bergreifende Energiesystemmodellierung}, series = {Optionen f{\"u}r ein nachhaltiges Energiesystem mit Power-to-X-Technologien: Transformation - Anwendungen - Potentiale. 3. Roadmap des Kopernikus-Projektes P2X, Phase II}, booktitle = {Optionen f{\"u}r ein nachhaltiges Energiesystem mit Power-to-X-Technologien: Transformation - Anwendungen - Potentiale. 3. Roadmap des Kopernikus-Projektes P2X, Phase II}, editor = {Ausfelder, Florian and Dura, Hanna Ewy}, publisher = {DECHEMA Gesellschaft f{\"u}r Chemische Technik und Biotechnologie e.V.}, address = {Frankfurt a.M.}, isbn = {978-3-89746-236-6}, pages = {19 -- 33}, language = {de} } @article{LindnerPipaKarpenetal., author = {Lindner, Matthias and Pipa, Andrei V. and Karpen, Norbert and Hink, R{\"u}diger and Berndt, Dominik and Foest, R{\"u}diger and Bonaccurso, Elmar and Weichwald, Robert and Friedberger, Alois and Caspari, Ralf and Brandenburg, Ronny and Schreiner, Rupert}, title = {Icing Mitigation by MEMS-Fabricated Surface Dielectric Barrier Discharge}, series = {Applied Sciences}, volume = {11}, journal = {Applied Sciences}, number = {23}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/app112311106}, pages = {1 -- 17}, abstract = {Avoiding ice accumulation on aerodynamic components is of enormous importance to flight safety. Novel approaches utilizing surface dielectric barrier discharges (SDBDs) are expected to be more efficient and effective than conventional solutions for preventing ice accretion on aerodynamic components. In this work, the realization of SDBDs based on thin-film substrates by means of micro-electro-mechanical-systems (MEMS) technology is presented. The anti-icing performance of the MEMS SDBDs is presented and compared to SDBDs manufactured by printed circuit board (PCB) technology. It was observed that the 35 mu m thick electrodes of the PCB SDBDs favor surface icing with an initial accumulation of supercooled water droplets at the electrode impact edges. This effect was not observed for 0.3 mu m thick MEMS-fabricated electrodes indicating a clear advantage for MEMS-technology SDBDs for anti-icing applications. Titanium was identified as the most suitable material for MEMS electrodes. In addition, an optimization of the MEMS-SDBDs with respect to the dielectric materials as well as SDBD design is discussed.}, language = {en} } @techreport{MartererKemeterLangetal., author = {Marterer, Verena and Kemeter, Dominik and Lang, Andreas and Dischner, Alexander and Huber, Stephanie and Obermeier, Maximilian and Langer, Tobias}, title = {FMS-Berichte Sommersemester 2021}, editor = {Meier, Hans and Niemetz, Michael and Reindl, Andrea}, address = {Regensburg}, doi = {10.35096/othr/pub-2104}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-21040}, pages = {VI, 37}, abstract = {Dieser Bericht entstand auf Initiative der Studierenden des 2020 neu gegr{\"u}ndeten Masterstudiengangs „Elektro- und Informationstechnik (MEI)", die an der Pflichtlehrveranstaltung „Forschungsmethoden und Seminar (FMS)" im Sommersemester 2021 teilnahmen. Diese Lehrveranstaltung hat das Ziel, systematisch an das wissenschaftliche Arbeiten, speziell die Wissenschaftskommunikation, heranzuf{\"u}hren. Daher war geeignete Literatur zu einem individuellen Thema zu recherchieren, Ver{\"o}ffentlichungen auf ihre Relevanz hin zu beurteilen und letztendlich eine eigene Ausarbeitung basierend auf der Literaturrecherche zu erarbeiten und diese in einem Vortrag zu pr{\"a}sentieren. Parallel dazu erfolgte im Theorieteil die entsprechende Hinf{\"u}hrung zu den verschiedenen Elementen der Wissenschaftskommunikation: • Bedeutung der Wissenschaftskommunikation f{\"u}r die Arbeit der Ingenieure in Forschung und Entwicklung • Literaturrecherche, Suchmaschinen, Sichtung und Analyse vorhandener Publikationen, Bewertung der Qualit{\"a}t aufgefundener Fachliteratur, Auswahl geeigneter Materialien f{\"u}r die eigene Arbeit • Aufbereitung und Darstellung der recherchierten technischer Inhalte in Form einer seitenanzahlbegrenzten wissenschaftlichen Ausarbeitung • Einhalten formaler Randbedingungen bzgl. Strukturierung, einschl. Bildnachweise und Zitationsstile • Peer-review-Prozess bei wertsch{\"a}tzender Beurteilung der Leistung anderer • Publikumsangepasstes Aufbereiten komplexer fachlicher Inhalte mit hochschul{\"o}ffentlicher Pr{\"a}sentation der Ergebnisse • F{\"u}hren m{\"u}ndlicher wissenschaftlicher Diskurse Nachdem die Masterstudierenden in der Regel {\"u}ber noch keine eigene wissenschaftliche Forschungserfahrung bzw. -inhalte verf{\"u}gen, lag der w{\"a}hlbare Schwerpunkt der Literatursuche auf der Bearbeitung von vorgegeben aktuellen technischen oder gesellschaftspolitischen Forschungsthemen.}, subject = {Elektrotechnik}, language = {de} } @article{GaertnerRankHeberletal., author = {G{\"a}rtner, Sebastian and Rank, Daniel and Heberl, Michael and Gaderer, Matthias and Dawoud, Belal and Haumer, Anton and Sterner, Michael}, title = {Simulation and Techno-Economic Analysis of a Power-to-Hydrogen Process for Oxyfuel Glass Melting}, series = {Energies}, volume = {14}, journal = {Energies}, number = {24}, publisher = {MDPI}, doi = {10.3390/en14248603}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-22713}, abstract = {As an energy-intensive industry sector, the glass industry is strongly affected by the increasingly stringent climate protection targets. As established combustion-based production systems ensure high process stability and glass quality, an immediate switch to low greenhouse gas emission processes is difficult. To approach these challenges, this work investigates a step-by-step integration of a Power-to-Hydrogen concept into established oxyfuel glass melting processes using a simulation approach. This is complemented by a case study for economic analysis on a selected German glass industry site by simulating the power production of a nearby renewable energy park and subsequent optimization of the power-to-hydrogen plant performance and capacities. The results of this study indicate, that the proposed system can reduce specific carbon dioxide emissions by up to 60\%, while increasing specific energy demand by a maximum of 25\%. Investigations of the impact of altered combustion and furnace properties like adiabatic flame temperature (+25 °C), temperature efficiency (∆ξ = -0.003) and heat capacity flow ratio (∆zHL = -0.009) indicate that pure hydrogen-oxygen combustion has less impact on melting properties than assumed so far. Within the case study, high CO2 abatement costs of 295 €/t CO2-eq. were determined. This is mainly due to the insufficient performance of renewable energy sources. The correlations between process scaling and economic parameters presented in this study show promising potential for further economic optimization of the proposed energy system in the future.}, language = {en} } @inproceedings{GrabRauchGoetzetal., author = {Grab, Robin and Rauch, Johannes and G{\"o}tz, Rebekka and Br{\"u}ckl, Oliver and Eichner, Stefan and Engel, Bernd}, title = {Q-Dynamik: Blindleistungsstellgeschwindigkeiten im Verteilnetz}, series = {Zuk{\"u}nftige Stromnetze: 27.-28. Januar 2021, 03.-04. Februar 2021, Tagungsunterlagen}, booktitle = {Zuk{\"u}nftige Stromnetze: 27.-28. Januar 2021, 03.-04. Februar 2021, Tagungsunterlagen}, publisher = {Conexio-PSE GmbH}, address = {Pforzheim}, isbn = {978-3-948176-12-9}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-58762}, pages = {46 -- 55}, abstract = {Mit der Energiewende geht eine starke Dezentralisierung der Energieeinspeisung einher. So sind im Deutschland des Jahres 2020 rund 31.000 Windenergieanlagen (WEA) in Betrieb, w{\"a}hrend bei der Solarenergie vor kurzem die zweimillionste Photovoltaik-Anlage (PVA) installiert wurde. Fast alle diese dezentralen Energieressourcen (DER) sind nach den Einspeiserichtlinien der Vergangenheit und der Gegenwart in der Lage, Blindleistung bereitzustellen, um die Spannung im Netz zu regeln und zum Blindleistungsausgleich beizutragen. Weitere potentielle dezentrale Blindleistungsquellen wie Blockheizkraftwerke, Kompensationsanlagen und perspektivisch sogar Verbraucher und Speicher sind im Verteilnetz zu finden. Durch den stetigen R{\"u}ckbau konventioneller Großkraftwerke, welche dem {\"U}bertragungsnetz bisher als Blindleistungsquellen zur Verf{\"u}gung standen, bedarf es einer Untersuchung mit der Fragestellung, in welchem Maß die neue Erzeugungslandschaft auch in diesem Feld als Ersatz dienen kann. Ein m{\"o}gliches Hindernis f{\"u}r einen breitangelegten Einsatz von DER zu Zwecken des spannungsebenen{\"u}bergreifenden Blindleistungsmanagements ist mangelndes Wissen {\"u}ber die Regeldynamik dieser verteilten Blindleistungsquellen. {\"U}bertragungs- und Verteilnetzbetreiber, die DER aktiv f{\"u}r Blindleistungsausgleich oder statische Spannungsregelung einsetzen, geben in der Regel ihre Blindleistungsanforderungen in kleineren Stufen mit erheblichen Latenzzeiten zwischen zwei Schritten weiter. Bef{\"u}rchtet wird, dass schnellere Spr{\"u}nge in der Blindleistungsvorgabe zu instabilen Betriebszust{\"a}nden oder anderweitigen Fehlfunktionen im Netz f{\"u}hren k{\"o}nnen. Eine genauere Kenntnis der dynamischen F{\"a}higkeiten vorhandener Blindleistungsquellen sowie der Auswirkungen auf die Netzstabilit{\"a}t und den Netzschutz k{\"o}nnte dazu beitragen, die Geschwindigkeit der Blindleistungsbereitstellung zu optimieren und somit tempor{\"a}re Spannungsschwankungen und -verluste zu minimieren und die Spannungsstabilit{\"a}t insgesamt zu verbessern. Durch eine entsprechende Regelungs- und Einsatzstrategie kann ein optimales Zusammenspiel der verschiedenen Technologien zur Deckung der Blindleistungsbedarfe f{\"u}r unterschiedliche Zeitbereiche erzielt werden. Hierf{\"u}r ist eine genaue Kenntnis der Blindleistungsstellgeschwindigkeiten und des dynamischen Regelverhaltens erforderlich. Dieser Beitrag stellt dazu Ergebnisse aus dem Forschungsprojekt „Q-Integral" vor. Um die relevanten Zeitkonstanten der Blindleistungsbereitstellung vollst{\"a}ndig aufzuf{\"u}hren, werden zun{\"a}chst typische Kommunikationszeiten f{\"u}r die {\"U}bermittlung von Sollwerten diskutiert. Anschließend werden Untersuchungen zu theoretischen und praktischen Reaktionszeiten verschiedener Blindleistungsquellen vorgestellt. Daf{\"u}r werden verschiedene Technologien wie Umrichter f{\"u}r PVA, Batteriespeicher und WEA sowie Synchrongeneratoren, die bei thermischen Kraftwerken die dominierende Technologie sind, betrachtet. Abschließend werden diese Werte mit realen Blindleistungsstellgeschwindigkeiten von ausgedehnten Wind- und Solarkraftwerken verglichen.}, language = {de} } @incollection{Rill, author = {Rill, Georg}, title = {Vehicle Dynamics in Real-Time Simulation}, series = {The dynamics of vehicles on roads and on tracks}, booktitle = {The dynamics of vehicles on roads and on tracks}, editor = {Apetaur, Milan}, publisher = {CRC Press}, address = {Boca Raton}, isbn = {9781003210894}, doi = {10.1201/9781003210894-40}, pages = {337 -- 347}, abstract = {This paper presents some ideas on a new concept, named COMPACT (Computer Simulation of Passenger Cars and Trucks). COMPACT was developed for the mathematical description of vehicles in all driving situations. As COMPACT is completely adopted to the particular problems in road vehicle dynamics, it results in a computer code where execution time is minimized. Thus, even real-time application at the Daimler-Benz driving simulator is possible. Previous Chapter Next Chapter}, language = {en} } @article{SavelevFetisovChashinetal., author = {Savelev, Dmitrii V. and Fetisov, Leonid Y. and Chashin, Dmitri V. and Fetisov, Yuri K. and Khon, Anastasia and Shamonin (Chamonine), Mikhail}, title = {Effects of ferromagnetic-material thickness on magnetoelectric voltage transformation in a multiferroic heterostructure}, series = {Smart Materials and Structures}, volume = {30}, journal = {Smart Materials and Structures}, number = {6}, publisher = {IOP PUBLISHING}, doi = {10.1088/1361-665X/abf6c0}, abstract = {A magnetoelectric (ME) voltage transformer is fabricated on the basis of a ferromagnetic (FM)-piezoelectric (PE) heterostructure comprising two equally thick laminated layers of an amorphous FM alloy and a piezoceramic lead zirconate-titanate layer sandwiched between them. The structure, placed inside an excitation coil, is electrically poled and magnetized in the direction of the long axis. The primary voltage is applied to the coil and the secondary voltage is measured between the electrodes of the PE material. It is shown for the first time that the change in the total thickness of magnetic layers significantly influences the transformer ' s characteristics. At the largest total thickness of FM layers of 138 mu m, the open-circuit voltage transformation ratio K has a maximum value of about 20, and the power transfer efficiency eta at a matched resistive load of about 20 k omega reaches 45\%. The variation of the control magnetic field in the range of 0-21.6 kA m(-1) makes it possible to change the voltage transformation ratio K from zero to the maximum value. A simple model allows one to calculate the dependence of the characteristics of the ME transformer on the frequency of the primary voltage, thickness of the FM layers, control magnetic field, and the load.}, language = {en} }