@inproceedings{BirkenmaierKrenkel, author = {Birkenmaier, Clemens and Krenkel, Lars}, title = {Convolutional Neural Networks for Approximation of Internal Non-Newtonian Multiphase Flow Fields}, series = {14th World Congress on Computational Mechanics (WCCM), ECCOMAS Congress 2020: 19-24 July 2020, Paris, France}, booktitle = {14th World Congress on Computational Mechanics (WCCM), ECCOMAS Congress 2020: 19-24 July 2020, Paris, France}, editor = {Chinesta, F. and Abgrall, R. and Allix, O. and Kalistke, M}, publisher = {CIMNE}, doi = {10.23967/wccm-eccomas.2020.107}, abstract = {Neural networks (NNs) as an alternative method for universal approximation of differential equations have proven to be computationally efficient and still sufficiently accurate compared to established methods such as the finite volume method (FVM). Additionally, analysing weights and biases can give insights into the underlying physical laws. FVM and NNs are both based upon spacial discretisation. Since a Cartesian and equidistant grid is a raster graphics, image-to-image regression techniques can be used to predict phase velocity fields as well as particle and pressure distributions from simple mass flow boundary conditions. The impact of convolution layer depth and number of channels of a ConvolutionDeconvolution Regression Network (CDRN), on prediction performance of internal non-Newtownian multiphase flows is investigated. Parametric training data with 2055 sets is computed using FVM. To capture significant non-Newtownian effects of a particle-laden fluid (e.g. blood) flowing through small and non-straight channels, an Euler-Euler multiphase approach is used. The FVM results are normalized and mapped onto an equidistant grid as supervised learning target. The investigated NNs consist of n= {3, 5, 7} corresponding encoding/decoding blocks and different skip connections. Regardless of the convolution depth (i.e. number of blocks), the deepest spacial down-sampling via strided convolution is adjusted to result in a 1 × 1 × f · 2nfeature map, with f = {8, 16, 32}. The prediction performance expressed is as channel-averaged normalized root mean squared error (NRMSE). With a NRMSE of < 2 · 10-3, the best preforming NN has f = 32 initial feature maps, a kernel size of k = 4, n = 5 blocks and dense skip connections. Average inference time from this NN takes < 7 · 10-3s. Worst accuracy at NRMSE of approx 9 · 10-3is achieved without any skips, at k = 2, f = 16 and n = 3, but deployment takes only < 2 · 10-3s Given an adequate training, the prediction accuracy improves with convolution depth, where more features have higher impact on deeper NNs. Due to skip connections and batch normalisation, training is similarly efficient, regardless of the depth. This is further improved by blocks with dense connections, but at the price of a drastically larger model. Depending on geometrical complexity, spacial resolution is critical, as it increases the number of learnables and memory requirements massively.}, language = {en} } @inproceedings{KrenkelPennecotLenzetal., author = {Krenkel, Lars and Pennecot, Julien and Lenz, Christian and Feldmann, Daniel and Wagner, Claus}, title = {Optimierung der Hochfrequenz-Oszillationsventilation mittels str{\"o}mungsmechanischer Methoden und kontrastgasgest{\"u}tzter Magnetresonanztomografie - Teilprojekt: Rekonstruktion von Geometrien aus medizinischen Bilddaten und Erstellung von Modellen f{\"u}r experimentelle Str{\"o}mungsuntersuchungen}, series = {Laseranwendung in der Medizin, Erfassen und Verarbeiten kardiovaskul{\"a}rer Signale, protektive Beatmungskonzepte : 3. Dresdner Medizintechnik-Symposium - mit DFG-Forschungsschwerpunkt Protektive Beatmungskonzepte, 6. bis 9. Dezember 2010, Dresden}, booktitle = {Laseranwendung in der Medizin, Erfassen und Verarbeiten kardiovaskul{\"a}rer Signale, protektive Beatmungskonzepte : 3. Dresdner Medizintechnik-Symposium - mit DFG-Forschungsschwerpunkt Protektive Beatmungskonzepte, 6. bis 9. Dezember 2010, Dresden}, editor = {F{\"u}ssel, Jens and Koch, Edmund and Malberg, Hagen}, publisher = {TUDpress}, address = {Dresden}, isbn = {978-3-942710-02-2}, pages = {107 -- 114}, abstract = {Der vorliegende Artikel skizziert die neu entwickelte Prozesskette f{\"u}r detailgenaue Rekonstruktion von Geometrien anhand medizinischer Bilddaten sowie die Herstellung von transparenten Modellen f{\"u}r experimentelle Untersuchungen mit bildgebenden Str{\"o}mungsmessverfahren. Die Geometriedaten und Modelle werden f{\"u}r systematische Untersuchungen der komplexen Transportvorg{\"a}nge in den Atemwegen bei k{\"u}nstlicher Beatmung mittels Hochfrequenzoszillationsventilation (HFOV) verwendet.}, language = {en} } @misc{TauwaldQuadrioRuettenetal., author = {Tauwald, Sandra Melina and Quadrio, Maurizio and R{\"u}tten, Markus and Stemmer, Christian and Krenkel, Lars}, title = {High Spatial Resolution Tomo-PIV of the Nasopharynx Focussing on the Physiological Breathing Cycle}, series = {23. DGLR Fach-Symposium Str{\"o}mungen mit Abl{\"o}sung, 09./10. November 2022, Berlin, Deutschland}, journal = {23. DGLR Fach-Symposium Str{\"o}mungen mit Abl{\"o}sung, 09./10. November 2022, Berlin, Deutschland}, address = {G{\"o}ttingen}, organization = {Deutsche Gesellschaft f{\"u}r Luft- und Raumfahrt e.V. / Arbeitsgemeinschaft Str{\"o}mungen mit Abl{\"o}sung, AG STAB}, abstract = {Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person's head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras' double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field.}, language = {en} } @misc{StelzerTauwaldVielsmeieretal., author = {Stelzer, Vera and Tauwald, Sandra Melina and Vielsmeier, Veronika and Cieplik, Fabian and Kandulski, Arne and Schneider-Brachert, Wulf and Wuensch, Olaf and R{\"u}tten, Markus and Krenkel, Lars}, title = {Generation, Distribution, and Contagiousness of Surgical Smoke during Tracheotomies}, series = {23. DGLR Fach-Symposium Str{\"o}mungen mit Abl{\"o}sung, 09./10. November 2022, Berlin, Deutschland}, journal = {23. DGLR Fach-Symposium Str{\"o}mungen mit Abl{\"o}sung, 09./10. November 2022, Berlin, Deutschland}, address = {G{\"o}ttingen}, organization = {Deutsche Gesellschaft f{\"u}r Luft- und Raumfahrt e.V. / Arbeitsgemeinschaft Str{\"o}mungen mit Abl{\"o}sung, AG STAB}, abstract = {Surgical smoke has been a little discussed topic in the context of the current pandemic. Surgical smoke is generated during the cauterization of tissue with heat-generating devices and consists of 95\% water vapor and 5\% cellular debris in the form of particulate matter. In-vivo investigations are performed during tracheotomies where surgical smoke is produced during tissue electrocautery. Furthermore, in-vitro parametric studies to investigate the particle number and size distribution and the spatial distribution of surgical smoke with laser light sheet technique are conducted. The higher the power of the high-frequency-device the larger the particles in size and the higher the resulting particle counts. The images taken show the densest smoke at 40W with artificial saliva. The resulting characteristic size distribution, which may include viruses and bacterial components, confirms that the risk arising from surgical smoke should be considered. Furthermore, the experiments will provide the database for further numerical investigations.}, language = {en} } @misc{Krenkel, author = {Krenkel, Lars}, title = {Maskenpflicht f{\"u}r Aerosole - wie wir medizinisches Personal in der Pandemie sch{\"u}tzen}, series = {TRIOKON Digital 2021 : Zukunft Ostbayern, 29.09.2021, Weiden, Deutschland}, journal = {TRIOKON Digital 2021 : Zukunft Ostbayern, 29.09.2021, Weiden, Deutschland}, language = {de} } @misc{StelzerRuettenKrenkel, author = {Stelzer, Vera and R{\"u}tten, Markus and Krenkel, Lars}, title = {Numerical Investigation of a 3D Dragonfly Wing Captured with a High-Resolution Micro-CT}, series = {8th European Congress on Computational Methods in Applied Sciences and Engineering, ECCOMAS Congress 2022, 5-9 June 2022, Oslo, Norway}, journal = {8th European Congress on Computational Methods in Applied Sciences and Engineering, ECCOMAS Congress 2022, 5-9 June 2022, Oslo, Norway}, abstract = {The special wing geometry of dragonflies consisting of veins and a membrane forming a corrugated profile leads to special aerodynamic characteristics. To capture the governing flow regimes of a dragonfly wing in detail, a realistic wing model has to be investigated. Therefore, this study aimed to analyze the aerodynamic characteristics of a 3D dragonfly wing reconstructed from a high-resolution micro-CT scan. Afterwards, a spatially high discretized mesh was generated using the mesh generator CENTAUR™ 14.5.0.2 (CentaurSoft, Austin, TX, US) to finally conduct Computational Fluid Dynamics (CFD) investigations in Fluent® 2020 R2 (ANSYS, Inc., Canonsburg, PA, US). Due to the small dimensions of the wing membrane, only the vein structure of a Camacinia Gigantea was captured at a micro-CT voxel size of 7 microns. The membrane was adapted and connected to the vein structure using a Boolean union operation. Occurring nconsistencies after combining the veins and the membrane were corrected using an adapted pymesh script [1]. As an initial study, only one quarter of the wing (outer wing section) was investigated to reduce the required computational effort. The resulting hybrid mesh consisting of 10 pseudo-structured prism layers along the wing surface and tetrahedra in the farfield area has 43 mio. nodes. The flow around the wing was considered to be incompressible and laminar using transient calculations. When the flow passes the vein structures, steady vortices occur in the corrugation valleys leading to recirculation zones. Therefore, the dragonfly wing resembles the profile of an airfoil. This leads to comparable lift coefficients of dragonfly wings and airfoil profiles at significantly reduced structural weight. The reconstructed geometry also included naturally occurring triangular prismlike serrated structures at the leading edge of the wing, which have comparable effects to micro vortex generators and might stabilize the recirculation zones. Further work aims to investigate the aerodynamic properties of a complete dragonfly wing during wing flapping.}, language = {en} } @misc{BirkenmaierKrenkel, author = {Birkenmaier, Clemens and Krenkel, Lars}, title = {Towards a realistic model of blood viscosity and coagulation in membrane oxygenators}, series = {6th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems) - ECCM 6; 7th European Conference on Computational Fluid Dynamics - ECFD 7 : Glasgow, Scotland, UK, June 11-15, 2018}, journal = {6th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems) - ECCM 6; 7th European Conference on Computational Fluid Dynamics - ECFD 7 : Glasgow, Scotland, UK, June 11-15, 2018}, abstract = {Modelling blood flow an shear induced coagulation in membraene oxygenators (MO) is challenging. The relevant geometry of oxygenator fibers (OF) and chaining threads is complex and spans several length scales. In relevant scales and regimes blood shows several significant non-Newtonian effects. Existing models are only capable of accounting for some, but not all relevant effects. Additionally, coagulation processes are influencing fluid properties and geometry significantly. Due to the enormous size of the discretised geometries highly detailed viscosity and coagulation properties of blodd flow in MOs. First step is to find a gemoetry dependent viscosity representation on basis of parametric micro channel experiments with anti-coagulated blood. Next step is a statistic coagulation model, based on micro channel experiments with human (re-calcified citrated) whole blood an evaluation of clinically used osygenators. Since shear rate dependent (i.e. viscosity dependet) coagulation in return influences the viscosity, a combined model with suitable implementation in a RANS framework is necessary. Towards this end, micro channel experiments with new and used single OFs triggering coagulation are performed. Structures of multimeric von Willebrand fibers (vWF), as indicator for shear induced coagulation, are compared to computed and measured flow conditions, using immunofluorescence microscopy, RANS-computations and µPIV, respectively. Preliminary examinations in clinically used MOs show good agreement between occurring structures of vWF, cell depositions and computed flow patterns (geometry form µCT-Scans). However, computed shear rates might be to low to actually trigger activation of vWF. The complex geometry of MOs results in huge meshes, which makes RANS with statistical modelling of viscosity and coagulation a reasonable approach. Towards this end, experimental data on micro channel level with evaluation on real application level is crucial. Especially regarding clotting processes, micro fluidic experiments are powerful research tool.}, language = {en} } @inproceedings{BirkenmaierSteigerPhilippetal., author = {Birkenmaier, Clemens and Steiger, Tamara and Philipp, Alois and Lehle, Karla and Krenkel, Lars}, title = {Flow-induced accumulations of von Willebrand factor inside oxygenators during extracorporeal life support therapy}, series = {Proceedings of 12th International Conference BIOMDLORE 2018, June 28-30, 2018, Białystok, Poland}, booktitle = {Proceedings of 12th International Conference BIOMDLORE 2018, June 28-30, 2018, Białystok, Poland}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-5386-2396-1}, doi = {10.1109/BIOMDLORE.2018.8467205}, pages = {3}, abstract = {BACKGROUND: Shear-induced conformational changes of von Willebrand factor (vWF) may be responsible for coagulation disorder and clot formation inside membrane oxygenators (MOs) during extracorporeal membrane oxygenation (ECMO) therapy. OBJECTIVE: The aim was to identify vWF structures inside clinically used MOs and employ computational fluid dynamics to verify the corresponding flow conditions. METHODS: Samples from gas exchange membranes (GEM) from MOs were analysed for accumulations of vWF and P-selectin-positive platelets using immunofluorescence techniques. Streamlines and shear rates of the flow around GEMs were computed using a laminar steady Reynolds-Averaged-Navier-Stokes approach. RESULTS: Most samples were colonized with equally distributed leukocytes, integrated in thin cobweb-like vWF-structures. Only 25 \% of the samples showed extended accumulations of vWF. Computed streamlines showed considerable cross flow between interconnected neighbouring channels. Stagnation points were non-symmetric and contact faces were washed around closely. The occurring maximum shear rates ranged from 2,500 to 3,000 1/s. CONCLUSIONS: If pronounced vWF structures are present, shape and extent match the flow computations well. Computed shear rates bear a critical degree of uncertainty due to the improper viscosity model. If flow conditions inside the MO were sufficient to affect vWF, a more consistent distribution of vWF across the samples should be present.}, language = {en} } @inproceedings{MarkusRuettenKrenkelKessler, author = {Markus R{\"u}tten, and Krenkel, Lars and Kessler, Roland}, title = {Secondary Flow Effects as Physical Mechanism of Molecular Species Transport in Highly Oscillating Generic-Trachea Flows}, series = {83rd Annual Scientific Conference of the International Association of Applied Mathematics and Mechanics, 26.-30. M{\"a}rz 2012, Darmstadt, Germany}, booktitle = {83rd Annual Scientific Conference of the International Association of Applied Mathematics and Mechanics, 26.-30. M{\"a}rz 2012, Darmstadt, Germany}, abstract = {The high frequency oscillation artificial respiration technique is often the last hope for patients to survive highly damaged lung tissue. The mortality can significantly be reduced. In comparison to conventional artificial respiration the applied volume flow rate and pressure is significantly lowered in order to avoid further damaging of lung tissue and remaining intact alveolae. However, the physical mechanism of transport of oxygen to the aeriols under high frequency oscillation is not well understood. In the upper part of the lung convection is dominant, in contrast, the gas exchange in the lower parts of the lung is mainly driven by diffusion. It is not clear how associated gradients of concentrations of different molecular species are then achieved. Highly oscillating fluid flows has been a long research topic in fluid dynamics. It is known that oscillating pressure fluctuations are able to induce secondary flows, in particular, in curved ducts and pipes. The question is, whether the trachea enforces the generation of secondary flow by its kidney like cross section geometry. The influence of molecular species of different densities onto the formation of secondary flows and the convectional transport within the trachea is investigated. In order to clarify the physical mechanisms behind flow simulations have been conducted by using state of the art CFD techniques.}, language = {en} } @inproceedings{FriedrichFeldmannKrenkeletal., author = {Friedrich, Janet and Feldmann, Daniel and Krenkel, Lars and Wagner, Claus and Schreiber, Laura Maria}, title = {19F Gas Flow Measurement of C3F7H During Constant Flow and High Frequency Oscillatory Ventilation}, series = {Discovery, innovation \& application - advancing mr for improved health : ISMRM 21st Annual Meeting \& Exhibition ; SMRT 22nd Annual Meeting Salt Lake City, Utah, USA 20-26 April 2013}, volume = {21}, booktitle = {Discovery, innovation \& application - advancing mr for improved health : ISMRM 21st Annual Meeting \& Exhibition ; SMRT 22nd Annual Meeting Salt Lake City, Utah, USA 20-26 April 2013}, organization = {International Society for Magnetic Resonance in Medicine}, abstract = {The aim of the current study is the development of MRI methods that enable the investigation of gas flow mechanisms during high frequency oscillatory ventilation. This work includes flow measurements during three constant flows (19.9, 30.6 and 41.4 L min-1) and the comparison to direct numerical simulations (DNS) using a second-order-acurate finite-volume method and to data measured with a volume flow meter. 19F-MRI, DNS and flow meter data are in good agreement. Flow measurements during HFOV of 4 Hz were successfully performed and velocity profiles could be recorded at different phases of the ventilation cycle.}, language = {en} } @inproceedings{BirkenmaierKrenkel, author = {Birkenmaier, Clemens and Krenkel, Lars}, title = {Convolutional Neural Networks for Approximation of Blood Flow in Artificial Lungs}, series = {New Results in Numerical and Experimental Fluid Mechanics XIII: Contributions to the 22nd STAB/DGLR Symposium}, booktitle = {New Results in Numerical and Experimental Fluid Mechanics XIII: Contributions to the 22nd STAB/DGLR Symposium}, number = {1. Auflage}, editor = {Dillmann, Andreas and Heller, Gerd and Kr{\"a}mer, Ewald and Wagner, Claus}, publisher = {Springer International Publishing}, address = {Cham}, isbn = {978-3-030-79560-3}, doi = {10.1007/978-3-030-79561-0_43}, pages = {451 -- 460}, abstract = {Blood flow in channels of varying diameters <500μm exhibits strong non-linear effects. Multiphase finite volume approaches are feasible, but still computationally costly. Here, the feasibility of applying convolutional neural networks for blood flow prediction in artificial lungs is investigated. Training targets are precomputed using an Eulerian two-phase approach. To match with experimental data, the interphase drag and lift, as well as intraphase shear-thinning are adapted. A recursively branching regression network and convolution/deconvolution networks with plain skip connections and densely connected skips are investigated. A priori knowledge is incorporated in the loss functional to prevent the network from learning non-physical solutions. Inference from neural networks is approximately six orders of magnitude faster than the classical finite volume approach. Even if resulting in comparably coarse flow fields, the neural network predictions can be used as close to convergence initial solutions greatly accelerating classical flow computations.}, language = {en} } @inproceedings{TauwaldQuadrioRuettenetal., author = {Tauwald, Sandra Melina and Quadrio, Maurizio and R{\"u}tten, Markus and Stemmer, Christian and Krenkel, Lars}, title = {High Spatial Resolution Tomo-PIV of the Trachea Focussing on the Physiological Breathing Cycle}, series = {New Results in Numerical and Experimental Fluid Mechanics XIV - Contributions to the 23nd STAB/DGLR Symposium}, booktitle = {New Results in Numerical and Experimental Fluid Mechanics XIV - Contributions to the 23nd STAB/DGLR Symposium}, publisher = {Springer}, abstract = {Investigations of complex patient-specific flow in the nasopharynx requires high resolution numerical calculations validated by reliable experiments. When building the validation base and the benchmark of computational fluid dynamics, an experimental setup of the nasal airways was developed. The applied optical measurement technique of tomo-PIV supplies information on the governing flow field in three dimensions. This paper presents tomo-PIV measurements of the highly complex patient-specific geometry of the human trachea. A computertomographic scan of a person's head builds the basis of the experimental silicone model of the nasal airways. An optimised approach for precise refractive index matching avoids optical distortions even in highly complex non-free-of-sight 3D geometries. A linear-motor-driven pump generates breathing scenarios, based on measured breathing cycles. Adjusting of the CCD cameras' double-frame-rate PIV-Δt enables the detailed analysis of flow structures during different cycle phases. Merging regions of interest enables high spatial resolution acquisition of the flow field.}, language = {en} } @article{KrieglKrenkelShamoninChamonine, author = {Kriegl, Raphael and Krenkel, Lars and Shamonin (Chamonine), Mikhail}, title = {Preservation of wetting ridges using field-induced plasticity of magnetoactive elastomers}, series = {Journal of Colloid and Interface Science}, volume = {683}, journal = {Journal of Colloid and Interface Science}, publisher = {Elsevier}, issn = {0021-9797}, doi = {10.1016/j.jcis.2024.12.132}, pages = {1019 -- 1027}, abstract = {Hypothesis. The presence of a wetting ridge is crucial for many wetting phenomena on soft substrates. Conventional experimental observations of a wetting ridge require permanent presence of a droplet. The magnetic field-induced plasticity effect (FIPE) of soft magnetoative elastomers (MAEs) allows one to overcome this limitation. Depositing a droplet onto an MAE surface and applying a magnetic field fixes the wetting ridge in place due to the FIPE. The droplet can be removed to investigate the ridge with ease using conventional optical methods. Experiments. The wetting ridge is observed on MAEs with different shear moduli and different material thicknesses by confocal laser scanning microscopy (LSM). The preservation quality of the ridge is analyzed for several values of magnetic field from 10 mT to 270 mT. To verify the plausibilty of results obtained, the measured shape is compared to a theoretical model by Style \& Dufresne. Findings. Upon removal of the sessile droplet, the deformation remains embossed onto the MAE surface as long as the magnetic field remains applied. The height of the ridge peak on soft samples (effective shear modulus kPa) is close to the theoretical prediction for a magnetic flux density of 50 mT. The magnitude of the external magnetic field magnifies the height of the wetting ridge.}, language = {en} } @misc{BirkenmaierDorniaLehleetal., author = {Birkenmaier, Clemens and Dornia, Christian and Lehle, Karla and Krenkel, Lars}, title = {Feasibility of detecting thrombotic deposits in membrane oxygenators using micro computed tomography}, series = {25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria}, journal = {25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria}, language = {en} } @inproceedings{TschurtschenthalerKrenkelSchreiner, author = {Tschurtschenthaler, Karl and Krenkel, Lars and Schreiner, Rupert}, title = {Mechano-optical micro pillar sensor for biofluidmechanic wall shear stress measurements}, series = {25th Congress of the European Society of Biomechanics (ESB), July 7-10, 2019, Vienna, Austria}, booktitle = {25th Congress of the European Society of Biomechanics (ESB), July 7-10, 2019, Vienna, Austria}, language = {en} } @misc{TauwaldKrenkel, author = {Tauwald, Sandra Melina and Krenkel, Lars}, title = {Elementary experimental setup for flow visualization in upper human respiratory tract}, series = {25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria}, journal = {25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria}, language = {en} } @misc{WagnerKrenkelDoenitzetal., author = {Wagner, Thomas and Krenkel, Lars and D{\"o}nitz, Christian and Brawanski, Alexander}, title = {Influence of CFD Strategy on WSS and OSI Determination for Intracranial Aneurysm Rupture Assessment}, series = {25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria}, journal = {25th Congress of the European Society of Biomechanics, July 7-10, 2019, Vienna, Austria}, language = {en} } @misc{Krenkel, author = {Krenkel, Lars}, title = {Relevanz von Aerosolen im klinischen Kontext}, series = {Innovationstag Hygiene 2021, Continental Arena, Regensburg, Deutschland}, journal = {Innovationstag Hygiene 2021, Continental Arena, Regensburg, Deutschland}, language = {de} } @misc{KrenkelMichelKeiletal., author = {Krenkel, Lars and Michel, Johanna and Keil, Niklas and Daschner, Jan}, title = {Experimental Investigation of Logitudinal Folds in Endotracheal Tube Cuffs and their Correlation to Silent Breathing}, series = {23. DGLR Fach-Symposium Str{\"o}mungen mit Abl{\"o}sung, 09./10. November 2022, Berlin, Deutschland}, journal = {23. DGLR Fach-Symposium Str{\"o}mungen mit Abl{\"o}sung, 09./10. November 2022, Berlin, Deutschland}, address = {G{\"o}ttingen}, organization = {Deutsche Gesellschaft f{\"u}r Luft- und Raumfahrt e.V. / Arbeitsgemeinschaft Str{\"o}mungen mit Abl{\"o}sung, AG STAB}, abstract = {Air leakage past High-Volume-Low-Pressure (HVLP) endotracheal tube (ETT) cuffs creates a potential infection risk for health care professionals during ventilation of patients suffering from contagious airborne diseases. However, unlike silent aspiration, a phenomenon where fluids enter the airways of intubated patients, the aspect of aerosol emergence through cuff folds -what we called accordingly "silent breathing" (SB)- has not been investigated in detail so far. This study investigates air leakage past HVLP cuffs with varying cuff pressures under realistic artificial breathing scenarios experimentally and in addition numerically. The focus was laid on the parametric investigation of the occurrence and furthermore on different influencing factors of silent breathing. The morphology of the folds responsible for the leakage was captured using high-resolution 3D microcomputed tomography (μCT). For the numerical investigations (Com-putational Fluid Dynamics - CFD), the commercial CFD Software package FLUENT 2021 R2 (ANSYS, Inc., Canonsburg, PA, US), as well as the DLR in-house research code THETA has been used.}, language = {en} } @inproceedings{RuettenKrenkelQuadrio, author = {R{\"u}tten, Markus and Krenkel, Lars and Quadrio, Maurizio}, title = {Simulation and Analyis of the Unsteady Flow within Nasal Airways}, series = {9th European Congress on Computational Methods in Applied Sciences and Engineering - ECCOMAS Congress, 3-7 June 2024, Lisbon, Portugal}, booktitle = {9th European Congress on Computational Methods in Applied Sciences and Engineering - ECCOMAS Congress, 3-7 June 2024, Lisbon, Portugal}, language = {en} } @inproceedings{KrenkelWagnerWolfetal., author = {Krenkel, Lars and Wagner, Claus and Wolf, Ursula and Scholz, Alexander-Wigbert K. and Terekhov, Maxim and Rivoire, Julien and Schreiber, W.}, title = {Protective Artificial Lung Ventilation: Impact of an Endotracheal Tube on the Flow in a Generic Trachea}, series = {New Results in Numerical and Experimental Fluid Mechanics VII : Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008}, booktitle = {New Results in Numerical and Experimental Fluid Mechanics VII : Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008}, editor = {Hirschel, Ernst Heinrich and Schr{\"o}der, Wolfgang and Fujii, Kozo and Haase, Werner and Leer, Bram and Leschziner, Michael A. and Pandolfi, Maurizio and Periaux, Jacques and Rizzi, Arthur and Roux, Bernard and Shokin, Yurii I. and Dillmann, Andreas and Heller, Gerd and Klaas, Michael and Kreplin, Hans-Peter and Nitsche, Wolfgang}, publisher = {Springer Berlin Heidelberg}, address = {Berlin, Heidelberg}, isbn = {978-3-642-14242-0}, doi = {10.1007/978-3-642-14243-7_62}, pages = {505 -- 512}, abstract = {Computational Fluid Dynamics (CFD) and experimental investigations on a generic model of the trachea have been carried out focusing on the impact of an endotracheal tube (ETT) on the resulting flow regime. It could be shown that detailed modelling of the airway management devices is essential for proper flow prediction, but secondary details as Murphy Eyes can be neglected. Models with bending and connector promote the formation of stronger secondary flows and disturbances which persist for a longer time.}, language = {en} } @misc{FriedrichRivoireScholzetal., author = {Friedrich, Janet and Rivoire, Julien and Scholz, Alexander-Wigbert K. and Wiegbert, and Terekov, Maxim and Kbrich, Rainer and Krenkel, Lars and Wagner, Claus and Schreiber, Laura Maria}, title = {Exploration of Gas Flow During High Frequency Oscillated Ventilation by 19F-Gas-MRI}, series = {Proceedings of the International Society for Magnetic Resonance in Medicine}, volume = {18}, journal = {Proceedings of the International Society for Magnetic Resonance in Medicine}, abstract = {To detect convective gas flow inside the large airways during high frequency oscillated ventilation (HFOV) the fluorinated contrast gas Heptafluoropropane was used for 19F-MRI. In a first study the comparison between constant flow measurements and Computational Fluid Dynamics (CFD) simulations provided a good agreement. In a following experiment oscillated flow was applied to a lung phantom consisting of ventilation bag and long pipe. The pressure wave inside the pipe was explored point-by-point and corresponding velocities were determined. With these experiments it could be shown for the first time that flow measurement during HFOV using fluorinated contrast gas is feasible.}, language = {en} } @misc{KreftingZaunsederSaeringetal., author = {Krefting, Dagmar and Zaunseder, Sebastian and S{\"a}ring, Dennis and Wittenberg, Thomas and Palm, Christoph and Schiecke, Karin and Krenkel, Lars and Hennemuth, Anja and Schnell, Susanne and Spicher, Nicolai}, title = {Blutdruck, H{\"a}modynamik und Gef{\"a}ßzustand: Innovative Erfassung und Bewertung - Schwerpunkt bildbasierte Verfahren}, series = {66. Jahrestagung der Deutschen Gesellschaft f{\"u}r Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform f{\"u}r die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online}, journal = {66. Jahrestagung der Deutschen Gesellschaft f{\"u}r Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform f{\"u}r die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online}, doi = {10.3205/21gmds016}, url = {http://nbn-resolving.de/urn:nbn:de:0183-21gmds0167}, abstract = {Einleitung: Blutdruck gilt als sogenannter Vitalparameter als einer der grundlegenden Indikatoren f{\"u}r den Gesundheitszustand einer Person. Sowohl zu niedriger als auch zu hoher Blutdruck kann lebensbedrohend sein, letzerer ist dar{\"u}ber hinaus ein Risikofaktor insbesondere f{\"u}r Herz-Kreislauferkrankungen, die trotz wichtiger Fortschritte in der Behandlung immer noch die h{\"a}ufigste Todesursache in Deutschland darstellen. Die H{\"a}modynamik, also die raumzeitliche Dynamik des Blutflusses, und der Gef{\"a}ßzustand sind eng verbunden mit dem Blutdruck und ebenfalls von hoher klinischer Relevanz, u.a. zur Identifikation von Durchblutungsst{\"o}rungen und ung{\"u}nstigen Druckverteilungen der Gef{\"a}ßwand. Innovationen in der Messtechnik als auch in der Datenanalyse bieten heute neue M{\"o}glichkeiten der Erfassung und Bewertung von Blutdruck, H{\"a}modynamik und Gef{\"a}ßzustand [1], [2], [3], [4]. Methodik: In einer gemeinsamen Workshopserie der AG Medizinische Bild- und Signalverarbeitung der GMDS und des Fachausschusses Biosignale der DGBMT werden wir neue Ans{\"a}tze und L{\"o}sungen f{\"u}r Mess- und Analyseverfahren zu Blutdruck und -fluss sowie zum Gef{\"a}ßzustand vorstellen und diskutieren. Dabei stehen im ersten Workshop auf der GMDS Jahrestagung Bildbasierte Verfahren im Zentrum, w{\"a}hrend der zweite Workshop auf der DGBMT Jahrestagung den Fokus auf Biosignalbasierten Verfahren legt. Es werden aktuelle Forschungsergebnisse vorgestellt und diskutiert. Es sind jeweils mehrere Vortr{\"a}ge geplant mit ausreichend Zeit zur Diskussion. Folgende Vortr{\"a}ge sind geplant (Arbeitstitel): Sebastian Zaunseder: Videobasierte Erfassung des Blutdrucks Anja Hennemuth: A Visualization Toolkit for the Analysis of Aortic Anatomy and Pressure Distribution Lars Krenkel: Numerische Analyse der Rupturwahrscheinlichkeit zerebraler Aneurysmata Susanne Schnell: Messung des Blutflusses und h{\"a}modynamischer Parameter mit 4D flow MRI: M{\"o}glichkeiten und Herausforderungen Ergebnisse: Ziel des Workshops ist die Identifikation von innovativen Ans{\"a}tzen und neuen Methoden zur qualitativen und quantitativen Bestimmung von h{\"a}modynamischen Parametern sowie deren kritische Bewertung durch die Community f{\"u}r die Eignung in der klinischen Entscheidungsunterst{\"u}tzung. Diskussion: Der Workshop leistet inhaltlich einen Beitrag zu zentralen Aspekten f{\"u}r die Herz-Kreislauf-Medizin. Er bringt dabei Expertise aus verschiedenen Bereichen zusammen und schl{\"a}gt die Br{\"u}cke zwischen Kardiologie, Medizininformatik und Medizintechnik. Schlussfolgerung: Innovative Technologien aus Medizintechnik und Informatik erm{\"o}glichen zunehmend einfache und raumzeitlich aufgel{\"o}ste Erfassung und Bewertung wichtiger Informationen zur Unterst{\"u}tzung von Diagnose und Therapieverfolgung. [1] Zaunseder S, Trumpp A, Wedekind D, Malberg H. Cardiovascular assessment by imaging photoplethysmography - a review. Biomed Tech (Berl). 2018 Oct 25;63(5):617-34. [2] Huellebrand M, Messroghli D, Tautz L, Kuehne T, Hennemuth A. An extensible software platform for interdisciplinary cardiovascular imaging research. Comput Methods Programs Biomed. 2020 Feb;184:105277. [3] Schmitter S, Adriany G, Waks M, Moeller S, Aristova M, Vali A, et al. Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T. Magn Reson Med. 2020 Oct;84(4):1947-60. [4] Birkenmaier C, and Krenkel, L. Flow in Artificial Lungs. In: New Results in Numerical and Experimental Fluid Mechanics XIII. Contributions to the 22nd STAB/DGLR Symposium. Springer; 2021.}, subject = {Blutdruck}, language = {de} }