@article{ReichHornberger, author = {Reich, Sven and Hornberger, Helga}, title = {The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns}, series = {Journal of Prosthetic Dentistry}, volume = {88}, journal = {Journal of Prosthetic Dentistry}, number = {1}, pages = {44 -- 49}, abstract = {Statement of problems: Computer-aided design/computer-assisted machining systems offer the possibility of fabricating restorations from one machinable ceramic block. Whether multishaded blocks improve esthetic results and are a viable alternative to individually stained ceramics has not been fully determined. Purpose: The aim of this investigation was to examine the effect of multishaded blocks on the esthetic appearance of all-ceramic CEREC crowns and compare these crowns with single-shade and stained restorations. Material and methods: Ten subjects were included in this study. For each subject, 6 different crowns were milled with the use of a CEREC machine. One crown was milled from each of the following machinable ceramic materials: CEREC Vitablocs Mark II in classic colors; Vitablocs Mark II in 3D-Master colors; Vitablocs Mark II in either classic or 3D-Master colors, with additional staining; Megadenta Bloxx multishaded; Mark II experimental multilayer; and an experimental multilayer leucite ceramic. Three independent examiners assessed the esthetic appearance of crowns fabricated to match each subject's anterior tooth shade. A scale of 1 to 6 was used to score the shade match and esthetic adaptation of each crown, with 1 representing excellent characteristics and 3.5 serving as the threshold for clinical acceptability. The examiners' scores were averaged, and the mean values were analyzed with the Wilcoxon signed rank test (P=40 MPa as measured according to ISO 6 872; said second material is an organic material which at least partly fills the pores of said porous matrix; and said composite material has a modulus of elasticity, E, of >=25 GPa as measured according to ISO 10 477.}, language = {en} } @misc{MuerrleHornberger, author = {Muerrle, Ulrich and Hornberger, Helga}, title = {Method of making a ceramic restoration}, pages = {8}, abstract = {Production of a dental reconstruction comprises: (a) forming a mold (12) from a model (10); (b) using (12) to make an isotropically heat-expandable replica from a ceramic precursor (14); (c) oxidizing (14) to produce an enlarged ceramic replica; (d) forming a silicone mold from this replica; (e) using (d) to make a second ceramic replica; and (f) sintering the second replica with volume reduction to form a replica identical to (10).}, language = {en} } @article{HornbergerMarquisFranks, author = {Hornberger, Helga and Marquis, Peter M. and Franks, J.}, title = {The impact of diamond-like coatings on the strength of dental ceramics}, series = {Journal of Dental Research}, volume = {74}, journal = {Journal of Dental Research}, pages = {522}, language = {en} } @article{HornbergerMarquis, author = {Hornberger, Helga and Marquis, Peter M.}, title = {Mechanical properties and microstructure of In-Ceram}, series = {Glastechnische Berichte - Glass Science and Technology}, volume = {68}, journal = {Glastechnische Berichte - Glass Science and Technology}, number = {6}, pages = {188 -- 194}, language = {en} } @article{KloiberAnetsbergerSchultheissetal., author = {Kloiber, Jessica and Anetsberger, Viktoria and Schultheiß, Ulrich and Hornberger, Helga}, title = {High quality surfaces of magnesium alloy AZ31 by adjusting appropriate electropolishing parameters}, series = {Electrochimica Acta}, volume = {513}, journal = {Electrochimica Acta}, publisher = {Elsevier}, doi = {10.1016/j.electacta.2024.145547}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-79298}, language = {en} } @article{KloiberSchultheissHornberger, author = {Kloiber, Jessica and Schultheiß, Ulrich and Hornberger, Helga}, title = {Impact of heat treatment on the surface quality of electropolished WE43 alloy}, series = {Materials Letters}, volume = {397}, journal = {Materials Letters}, publisher = {Elsevier BV}, issn = {0167-577X}, doi = {10.1016/j.matlet.2025.138821}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-83512}, pages = {5}, abstract = {In this study, the Mg alloy WE43 was solution annealed and precipitation hardened prior to electropolishing to evaluate the effects of different microstructures on the electropolishing result. While coarsely distributed precipitates led to surfaces showing wavy structures and dents after electropolishing, a uniform microstructure resulted in an even finish of the surface. The homogenization and refinement of the microstructure by heat treatment is a method to ensure improved electropolished surfaces of Mg materials}, language = {en} } @article{ManarancheHornberger, author = {Manaranche, Claire and Hornberger, Helga}, title = {A proposal for the classification of precious dental alloys according to their resistance to corrosion based on the iso 10271 standard}, series = {European Cells and Materials}, volume = {5}, journal = {European Cells and Materials}, number = {SUPPL. 1}, publisher = {Univ. of Wales}, address = {Aberystwyth, Wales}, pages = {34 -- 36}, abstract = {A lot of dental alloys are available on the market. Among these alloys, there are the conventional alloys, the so called casting alloys used without ceramics, the bonding alloys used with high fusing ceramics and the universal alloys used without or with low fusing ceramics. It is im portant to know the physical and mechanical properties of these materials but also their biocompatibility and their resistance to corrosion. Dental alloys are generally placed in the mouth for many years, they must not induce adverse biological reactions such as gingival swelling and erythema, mucosal pain and lichenoid reactions. Although these troubles are often caused not by the materials itself (1, 2), they can be induced by the metallic ions released during their corrosion. In order to decrease the risks to the health, it is necessary to study the corrosion of the dental alloys. Currently, the ISO 10271 Standard (3), describes 3 different corrosion tests: a static immersion test (chemical corrosion), an electrochemic al test and a tarnish test. However, there are no indications yet about the possible interpretation of test results. In this paper, we propose a method to compare and classify the dental alloys in relation to their chemical and electrochemical corrosion results. METHODS: The material tested are pure metals such as gold, palladium, silver, copper and zinc as well as dental alloys which are commercially sold (see Table 1). 54 different materials have been tested. A minimum of four samples of each material were tested by electrochemic al corrosio n and a minimum of three in chemical test. The samples were cast and prepared as indicated by the manufacturer and by the ISO 10271. For the electrochemical test, the samples are in the form of disks 11 mm in diameter. They are tested with a potentiostat/galvanostat Voltalab Model 21. For the chemical test, the samples are rectangular with the dimensions 35X10X1.7 mm. The solution used and the operating conditions are described in the ISO 10271. The concentration of metallic ions released is measured by Induced Coupled Plasma}, language = {en} } @article{SchultheissHornberger, author = {Schultheiß, Ulrich and Hornberger, Helga}, title = {Comparison of etchants for corrosion-resistant stainless steels in medical engineering}, series = {Practical Metallography}, volume = {62}, journal = {Practical Metallography}, number = {1}, publisher = {de Gruyter}, doi = {10.1515/pm-2024-0094}, pages = {19 -- 30}, abstract = {Corrosion-resistant stainless steels are widely used in medical engineering. Today, additive manufacturing techniques are also used for this purpose, in particular for implant steels. Additively processed materials sometimes react differently to etching than conventionally processed ones. The use of etchants for contrasting the microstructure must therefore be adapted. Chemical etching using V2A etchant, Murakami, and anhydrous Kalling solutions, as well as electrochemical etching using nitric acid, sodium hydroxide, and oxalic acid were performed. Etched samples made of conventionally processed X2CrNi-Mo17-12-2 were compared to samples manufactured using selective laser melting and sintering, and the optimal contrast was developed in each case. It can be shown that the different etchants reveal different microstructural constituents and that etchants must therefore be selected as a function of the application.}, language = {en} }