@article{Herrmann, author = {Herrmann, Frank}, title = {The Smart Factory and Its Risks}, series = {Systems}, volume = {6}, journal = {Systems}, number = {4}, publisher = {MDPI}, doi = {10.3390/systems6040038}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-1793}, pages = {1 -- 15}, abstract = {In this paper, the risks of a Smart Factory are to be examined and structured in order to be able to evaluate the status of the Smart Factory. This thesis thus serves as an overview of the technical components of a Smart Factory and the associated risks. The study takes a holistic view of the smart factory. The results show that the greatest need for action lies in the technological field. Thus, the topics of standardization, information security, availability of IT infrastructure, availability of fast internet and complex systems were prioritized. The organizational and financial risks, which also play an important role in a Smart Factory transformation, are addressed.}, subject = {Smart Factory}, language = {en} } @article{SchmitzNeumannNeumannetal., author = {Schmitz, Paul and Neumann, Christoph Cornelius and Neumann, Carsten and Nerlich, Michael and Dendorfer, Sebastian}, title = {Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting}, series = {Journal of Orthopaedic Surgery and Research}, volume = {13}, journal = {Journal of Orthopaedic Surgery and Research}, number = {108}, publisher = {Springer Nature}, doi = {10.1186/s13018-018-0822-1}, pages = {1 -- 8}, abstract = {Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture.}, subject = {Beckenkammknochen}, language = {en} } @article{PhilippdeSomerFoltanetal., author = {Philipp, Alois and de Somer, Filip and Foltan, Maik and Bredthauer, Andre and Krenkel, Lars and Zeman, Florian and Lehle, Karla}, title = {Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice}, series = {PLOS ONE}, volume = {13}, journal = {PLOS ONE}, number = {6}, publisher = {PLOS}, doi = {10.1371/journal.pone.0198392}, pages = {1 -- 10}, abstract = {Over the past decade, veno-venous extracorporeal membrane oxygenation (vvECMO) has been increasingly utilized in respiratory failure in patients. This study presents our institution´s experience focusing on the life span of ECMO systems reflecting the performance of a particular system. A retrospective review of our ECMO database identified 461 adult patients undergoing vvECMO (2010-2017). Patients that required more than one system and survived the first exchange >24 hours (n = 139) were included. Life span until the first exchange and exchange criteria were analyzed for all systems (PLS, Cardiohelp HLS-set, both Maquet Cardiopulmonary, Rastatt, Germany; Deltastream/Hilite7000LT, iLA-activve, Xenios/NovaLung, Heilbronn, Germany; ECC.O5, LivaNova, Mirandola, Italy). At our ECMO center, the frequency of a system exchange was 30\%. The median (IQR) life span was 9 (6-12) days. There was no difference regarding the different systems (p = 0.145 and p = 0.108, respectively). However, the Deltastream systems were exchanged more frequently due to elective technical complications (e. g. worsened gas transfer, development of coagulation disorder, increased bleedings complications) compared to the other exchanged systems (p = 0.013). In summary, the used ECMO systems are safe and effective for acute respiratory failure. There is no evidence for the usage of a specific system. Only the increased predictability of an imminent exchange preferred the usage of a Deltastream system. However, the decision to use a particular system should not depend solely on the possible criteria for an exchange.}, language = {en} } @article{DiermeierSindersbergerKrenkeletal., author = {Diermeier, Andreas and Sindersberger, Dirk and Krenkel, Lars and Rosell, X. C. and Monkman, Gareth J.}, title = {Controllable Magnetoactive Polymer Conduit}, series = {The Open Mechanical Engineering Journal}, volume = {12}, journal = {The Open Mechanical Engineering Journal}, number = {1}, publisher = {Bentham}, pages = {192 -- 200}, abstract = {Objective: Magneto-active Polymers (MAP) are smart materials whose mechanical characteristics, such as elastic and shear moduli, may be controllable by means of an externally applied magnetic field. Methods: Various additives may be used to influence the characteristics of the polymer matrix whilst a suspension of soft and/or hard magnetic particles determine the magnetic properties of the composite. Both pre-cure and post-cure magnetization is possible. Results: A range of control strategies have been investigated for evaluation of the system using fluids of differing kinematic viscosity. Conclusion: Depending on the degree of magnetic field homogeneity, magneto-deformation and magnetostriction contribute to MAP actuation. This paper presents a novel application in the form of a peristaltic MAP tube system, applicable to flow control and pumping of hemorheological fluids in blood circulatory systems for biomedical research purposes.}, language = {en} } @inproceedings{SchmailzlQuandtSchmidtetal., author = {Schmailzl, Anton and Quandt, Benjamin and Schmidt, Michael and Hierl, Stefan}, title = {In-Situ Process Monitoring during Laser Transmission Welding of PA6-GF30}, series = {Procedia CIRP}, volume = {74}, booktitle = {Procedia CIRP}, doi = {10.1016/j.procir.2018.08.131}, pages = {524 -- 527}, abstract = {Quasi-simultaneous laser transmission welding is preferably used for packaging sensors and electronics. In order to protect the components from moisture, a hermetic encapsulation is needed. However, local weld seam interruptions cannot be identified with the commonly used set-path monitoring. By using a pyrometer, coaxially integrated into a 3D-scanner, gaps between the joining partners can be allocated on basis of the measured temperature. However, the scattering of the heat radiation, especially caused by the fiber reinforcement of the plastics, leads to a reduction of the accessible heat radiation, which makes the identification of gaps considerably more difficult. The herein used experimental setup is characterized by a small detection spot and only by a slight weakening of the heat radiation inside the scanner. Hence, for welding PA6-GF30, the detection of small sized gaps is possible, even if a glass fiber content of 30 percent (wt.) and a weld seam width with approximately 1 mm are given.}, language = {en} } @incollection{AltenbuchnerHaugKretschmeretal., author = {Altenbuchner, Amelie and Haug, Sonja and Kretschmer, Rainer and Weber, Karsten}, title = {How to Measure Physical Motion and the Impact of Individualized Feedback in the Field of Rehabilitation of Geriatric Trauma Patients}, series = {Health Informatics Meets eHealth}, booktitle = {Health Informatics Meets eHealth}, doi = {10.3233/978-1-61499-858-7-226}, pages = {226 -- 232}, abstract = {Background: This preparatory study accelerates an implementation of individualized monitoring and feedback of physical motion using conventional motion trackers in the rehabilitation process of geriatric trauma patients. Regaining mobility is accompanied with improved quality of life in persons of very advanced age recovering from fragility fractures. Objectives: Quantitative survey of regaining physical mobility provides recommendations for action on how to use motion trackers effectively in a clinical geriatric setting. Methods: Method mix of quantitative and qualitative interdisciplinary and mutual complementary research approaches (sociology, health research, philosophy/ethics, medical informatics, nursing science, gerontology and physical therapy). While validating motion tracker use in geriatric traumatology preliminary data are used to develop a target group oriented motion feedback. In addition measurement accuracy of a questionnaire about quality of life of multimorbid geriatric patients (FLQM) is tested. Conclusion: Implementing a new technology in a complex clinical setting needs to be based on a strong theoretical background but will not succeed without careful field testing.}, language = {en} } @article{Weber, author = {Weber, Karsten}, title = {Computers as omnipotent instruments of power}, series = {The ORBIT Journal - An Online Journal for Responsible Research and Innovation in ICT}, volume = {2}, journal = {The ORBIT Journal - An Online Journal for Responsible Research and Innovation in ICT}, number = {1}, publisher = {Elsevier}, doi = {10.29297/orbit.v2i1.97}, pages = {1 -- 19}, abstract = {With examples concerning the development and dissemination of computer technology in the Soviet Union, the U.S., and other Western countries it shall be demonstrated that computer development on the one hand and social change as well as changes in policy making and administration on the other hand are mingled with each other without a clear direction of causation being discernible.It also shall be shown that perceived social and political threats imposed by early computer technology sometimes actually helped to stop or at least slow down social change. One conclusion that can be drawn from the case studies described for RRI is that the conscious steering of innovations fails because of diffuse and uncoordinated resistance from very different stakeholders. The case studies also suggest that the effectiveness of RRI might be rather limited.}, language = {en} } @article{WeberHaug, author = {Weber, Karsten and Haug, Sonja}, title = {Ist automatisiertes Fahren nachhaltig?}, series = {TATuP - Zeitschrift f{\"u}r Technikfolgenabsch{\"a}tzung in Theorie und Praxis}, volume = {27}, journal = {TATuP - Zeitschrift f{\"u}r Technikfolgenabsch{\"a}tzung in Theorie und Praxis}, number = {2}, publisher = {Karlsruhe Institute of Technology (KIT)}, doi = {10.14512/tatup.27.2.16}, pages = {16 -- 22}, abstract = {Automatisiertes Fahren st{\"o}ßt derzeit noch auf große Skepsis. Eine disruptive Strategie bei der Einf{\"u}hrung (voll-)automatisierten Fahrens k{\"o}nnte daher auf fehlende Akzeptanz treffen. Um dem zu entgehen, laufen evolution{\"a}re Strategien darauf hinaus, durch die Entwicklung adaptiver Fahrassistenzsysteme Vertrautheit, Vertrauen und damit Akzeptanz bei den prospektiven NutzerInnen zu schaffen. Erste Ergebnisse einer Pilotstudie lassen jedoch Zweifel an der Nachhaltigkeit dieser Strategie aufkommen.}, language = {de} } @inproceedings{BerndtLindnerTschurtschenthaleretal., author = {Berndt, Dominik and Lindner, Matthias and Tschurtschenthaler, Karl and Langer, Christoph and Schreiner, Rupert}, title = {Miniaturized Plasma Actuator Flow Measurements by MEMS-Based Thermal Conductivity Sensors}, series = {MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz}, volume = {Vol.13}, booktitle = {MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz}, number = {2}, doi = {10.3390/proceedings2130939}, abstract = {The gasflow created by a minaturized dielectric barrier discharge (DBD) plasma actuator is measured by a MEMS-based thermal conductivity gas sensor giving an indication of flow velocity and flow direction. The possiblity of several sensors in a small area gives a far better accuracy of local flow phenomena compared to conventional sensors. This is important for a better understanding of plasma- induced flow characteristics.}, language = {en} } @article{HaugMilewski, author = {Haug, Sonja and Milewski, Nadja}, title = {Women's attitudes towards assisted reproductive technologies}, series = {Comparative Population Studies. Special Collection on "New aspects in fertility of migrant and minority populations in Europe: The role of attitudes and intentions in family planning"}, volume = {Vol. 43}, journal = {Comparative Population Studies. Special Collection on "New aspects in fertility of migrant and minority populations in Europe: The role of attitudes and intentions in family planning"}, organization = {Federal Institute for Population Research     }, doi = {10.12765/CPoS-2019-06}, pages = {343 -- 370}, abstract = {This study examines attitudes toward assisted reproductive technologies (ART) among immigrant women and non-migrants in Germany. The social relevance of ART is increasing in Western countries due to overall low birth rates, a high rate of childlessness, and a gap between the desired and the actual numbers of children. Previous literature has been scarce, however, on attitudes toward ART, and immigrant minorities have rarely been included in studies on ART. Our working hypotheses are drawn from theoretical considerations on political socialisation and cultural integration. The analysis is based on data collected in a pilot study in 2014 and 2015. The sample includes 960 women aged 18 to 50 living in Germany. About 81 percent of the sample are immigrants who originate from Turkey, Poland, the Balkan countries, or countries of the (Russian) Commonwealth of Independent States (CIS). We study the social norm to use ART to have a child, the personal attitude of whether a woman would use ART herself, and the methods that they would consider for their own use. Our results show that ART is overall socially acceptable, and the majority of women said that they would use it if necessary. There is significant variation between the origin groups, however. Non-migrants show the lowest acceptance rates and migrants from Poland and Turkey the highest approval. There is also variation in the ART procedures considered for use with the migrants more approving of heterologous methods than non-migrants. The differences between the origin groups diminish only partly when controlling for further explanatory variables, i.e. gender-role attitudes, religiosity, and socio-demographic characteristics of the respondents. We conclude that attitudes toward ART are shaped less by socio-demographic characteristics, but rather by cultural factors and the socialization in the migrants' countries of origin. The diversity in attitudes toward ART by cultural background should be acknowledged in research and public discourses on ART as well as in regulating policies.}, language = {en} }