@article{ReschkeAuburgerMarichalaretal., author = {Reschke, Johannes and Auburger, Marie-Theres and Marichalar, Rebeca and Neumann, Cornelius}, title = {Communication between automated vehicles and pedestrians}, series = {ATZ worldwide}, volume = {121}, journal = {ATZ worldwide}, number = {9}, publisher = {Springer Nature}, address = {Wiesbaden}, doi = {10.1007/s38311-019-0098-z}, pages = {16 -- 23}, language = {en} } @techreport{KrewerSchaepersAndersenetal., author = {Krewer, Carmen and Sch{\"a}pers, Barbara and Andersen, Henning Boje and Linner, Thomas and Steinb{\"o}ck, Martina and Hu, Rongbo and Zhao, Charlie and G{\"u}ttler, J{\"o}rg and Schlandt, Marcel and Valk, Carlijn and Lu, Yuan and Kulev, Igor and Salehzadeh Niksirat, Kavous and Larsen, Rasmus Tostrup and Schrader, Lisa and Partyga, P. and Kraul, M. and Kozak, Dominika and Schwarze, A.-K. and Rusu, Alexandru and Murali, S. and Ricon, F. and Lingeg{\aa}rd, H. and v. Zanten, B. and Lovei, Peter and Visser, Thomas and Seelinger, Anja and van den Boom, Camilla and Steenbakkers, J. and Henriksen, L. and Randrinambelonoro, M. and Perrine, C.}, title = {Formalized results of final testing and optimization activities: Summarization of testing and evaluation of final testing of continuously improved system in the form of prototypes in real world environments and presentation of optimization measures.}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-36195}, abstract = {Deliverable D28: Formalized results of final testing and optimization activities: Summarization of testing and evaluation of final testing of continuously improved system in the form of prototypes in real world environments and presentation of optimization measures (associated with tasks T6.5, T6.6, T6.7, T6.8). D28 is an update on D27. Additional associated deliverables are D12, D13, D23, D31, and D44. Abstract: In order to provide a comprehensive summary of all testing activities, the medical core group (DTU, HUG, SK, TUM) created a mini protocol template (which requested the outline of some methodological aspects of each study such as study designs, the recruitment phase, population under investigation, etc.), and ensured that data were submitted and provided by the trial manager to the core group. In this deliverable we present, structure, and interpret the formalized results of the final testing and optimization activities of all testing activities in REACH. The deliverable includes the summarization of testing and evaluation of final testing of a continuously improved system in the form of prototypes in real world environments and the presentation of optimization measures. The deliverable is an update on deliverable D27 and associated with tasks T6.5, T6.6, T6.7, T6.8. In reaction to the reviewers' comments we initiated additional trials focusing on practice cases. Those trials are specifically ladled and included in the updated overview. A review on factors, i.e., falling, frailty, cognitive decline , sarcopenia, social isolation, and malnutrician, was performed to show the most important cofactors. Addressed in this deliverable is also the role of privacy and the hierarchy of needs which are essential components of the acceptance and use of technology .}, language = {en} } @incollection{HeesePreger, author = {Heese, Carl and Preger, Rudolf}, title = {Die Konvergenz von neurologischer Rehabilitation und P{\"a}dagogik}, series = {Alltag wieder lernen : Berichte vom 7. Symposium der Neurochirurgischen und Neurologischen Fachklinik Kipfenberg. - (Eichst{\"a}tter sozialp{\"a}dagogische Arbeiten ; 9)}, booktitle = {Alltag wieder lernen : Berichte vom 7. Symposium der Neurochirurgischen und Neurologischen Fachklinik Kipfenberg. - (Eichst{\"a}tter sozialp{\"a}dagogische Arbeiten ; 9)}, editor = {Preger, Rudolf}, publisher = {BPB-Verl. diritto-Publikationen}, address = {Eichst{\"a}tt}, isbn = {978-3927728462}, pages = {65 -- 71}, language = {de} } @incollection{Scheffler, author = {Scheffler, Gabriele}, title = {Finanzielle Unterst{\"u}tzung f{\"u}r Alleinerziehende}, series = {Knaurs Handbuch Familie : Alles was Eltern wissen m{\"u}ssen}, booktitle = {Knaurs Handbuch Familie : Alles was Eltern wissen m{\"u}ssen}, editor = {Fthenakis, Wassilios E. and Textor, Martin R.}, publisher = {Droemer Knaur}, address = {M{\"u}nchen}, isbn = {978-3-426-66940-2}, pages = {482 -- 485}, language = {de} } @techreport{SeelingerVogtLinneretal., author = {Seelinger, Anja and Vogt, L. and Linner, Thomas and G{\"u}ttler, J{\"o}rg and Hu, Rongbo and Schlandt, Marcel and Zhao, Charlie and Sch{\"a}pers, Barbara and Andersen, Henning Boje and Brombacher, A. and Lu, Yuan}, title = {Standardization activities}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-36227}, abstract = {REACH has the ambition to influence and gain from standardization on national, European, and international level. We aim to create synergies between parallel work on these levels that will finally make a beneficial impact. Systematic parallel and synergeti cwork on these levels allow REACH to create a maximized impact for all involved stakeholders, and in particular, create better health and health care "ecosystems" for potential REACH end users.}, language = {en} } @inproceedings{Weber, author = {Weber, Karsten}, title = {Die andere Seite der Verteilungsgerechtigkeit}, series = {Philosophische Perspektiven. Beitr{\"a}ge zum VII. {\"O}sterreichischen Kongress f{\"u}r Philosophie}, booktitle = {Philosophische Perspektiven. Beitr{\"a}ge zum VII. {\"O}sterreichischen Kongress f{\"u}r Philosophie}, editor = {Neumaier, O. and Sedmak, Clemens and Zichy, M.}, publisher = {Ontos}, address = {Lancaster}, pages = {5}, language = {de} } @article{SchliermannKleinSchulze, author = {Schliermann, Rainer and Klein, Petra and Schulze, Annette}, title = {Deaflympischer Sport - die unbekannte Sportbewegung}, series = {Leistungssport : Zeitschrift f{\"u}r die Fortbildung von Trainern, {\"U}bungsleitern und Sportlehrern}, volume = {46}, journal = {Leistungssport : Zeitschrift f{\"u}r die Fortbildung von Trainern, {\"U}bungsleitern und Sportlehrern}, number = {4}, publisher = {Philippka-Verlag}, address = {M{\"u}nster}, organization = {Deutscher Olympischer Sportbund}, issn = {0341-7387}, pages = {39 -- 44}, abstract = {Der deaflympische Sport (Syn.: Geh{\"o}rlosensport) ist sowohl in der medialen als auch in der sportaktiven {\"O}ffentlichkeit weithin unbekannt. Der paralympische Behindertensport wird zunehmend st{\"a}rker beachtet, der deaflympische hingegen insgesamt wenig. Im vorliegenden Beitrag wird deshalb ein {\"U}berblick gegeben. Es wird zun{\"a}chst dessen geschichtliche Entwicklung n{\"a}her beschrieben und verdeutlicht, dass der institutionalisierte Sport von Athleten mit H{\"o}rbeeintr{\"a}chtigungen die l{\"a}ngste Tradition im Behindertensport aufweist. Außerdem erfolgt eine Beschreibung der institutionellen Rahmenbedingungen dieser Sportbewegung. Dabei ist hervorzuheben, dass f{\"u}r die Belange des Leistungssports von Menschen mit H{\"o}rbeeintr{\"a}chtigungen der Deutsche Geh{\"o}rlosenSportverband (DGS) und nicht der Deutsche Behindertensportverband (DBS) zust{\"a}ndig ist, da es sich beim deaflympischen Sport um eine historisch gewachsene, eigenst{\"a}ndige Sportbewegung handelt. Die weiteren Ausf{\"u}hrungen betreffen Aspekte zum Training und Wettkampf von Athleten mit H{\"o}rsch{\"a}digungen. Um an Wettk{\"a}mpfen im Geh{\"o}rlosensport teilnehmen zu d{\"u}rfen, muss ein Mindestmaß an H{\"o}rminderung vorliegen. Die Teilnahme an hochrangigen (internationalen) Wettk{\"a}mpfen (z. B. Deaflympics) erfordert dann - wie im Spitzensport generell - ein systematisches und regelm{\"a}ßiges Training. In Bezug auf Athleten mit H{\"o}rminderungen bedeutet dies insbesondere eine bestimmte Art der Kommunikation, des Vermittelns bzw. Erlernens (neuer) Bewegungen sowie die Beachtung etwaiger Einschr{\"a}nkungen der Gleichgewichtsf{\"a}higkeit. Auf diese Aspekte wird in diesem {\"U}bersichtsbeitrag ausf{\"u}hrlich eingegangen. Es wird unter anderem verdeutlicht, dass „geh{\"o}rlose" Sportler h{\"a}ufig durchaus noch {\"u}ber ein Resth{\"o}rverm{\"o}gen verf{\"u}gen. Außerdem erfordert das Training eine bestimmte Art der Kommunikation zwischen Trainer und Athlet, um effektiv im Sinne einer Leistungsentwicklung sein zu k{\"o}nnen. Schließlich gehen mit H{\"o}reinschr{\"a}nkungen h{\"a}ufig auch Defizite der Gleichgewichtsf{\"a}higkeit einher, die jedoch nicht a priori vorhanden sind und sich durch Training verbessern lassen. Im Res{\"u}mee wird nochmals herausgestellt, weshalb Grundkenntnisse {\"u}ber den deaflympischen Sport nicht nur zur Leistungsentwicklung h{\"o}rgesch{\"a}digter Spitzenathleten beitragen, sondern auch Trainern und Vereinen des Regelsportsystems des Deutschen Olympischen Sportbundes (DOSB) n{\"u}tzlich sein k{\"o}nnen.}, language = {de} } @inproceedings{SchulzSchwarz, author = {Schulz, Carsten and Schwarz, Colin}, title = {Indirect Model Predictive Control and its Impact on the Fatigue Strength of the Drivetrain}, series = {10. VDI-Fachtagung Schwingungen von Windenergieanlagen 2019 : Bremen, 04.-05. Juni 2019}, booktitle = {10. VDI-Fachtagung Schwingungen von Windenergieanlagen 2019 : Bremen, 04.-05. Juni 2019}, isbn = {978-3-18-092346-8}, language = {en} } @inproceedings{SchwarzSchulz, author = {Schwarz, Colin and Schulz, Carsten}, title = {Indirekte nichtlineare Modellpr{\"a}diktive Regelung von Windkraftanlagen und deren Einfluss auf die Betriebsfestigkeit beteiligter Maschinenelemente}, series = {DMK - Dresdner Maschinenelemente Kolloquium, 2017, Dresden}, booktitle = {DMK - Dresdner Maschinenelemente Kolloquium, 2017, Dresden}, editor = {Schlecht, Berthold}, publisher = {sierke-Verlag}, language = {de} } @inproceedings{SchwarzSchulz, author = {Schwarz, Colin and Schulz, Carsten}, title = {Moderne, sch{\"a}digungsreduzierende Ans{\"a}tze zur Regelung einer Windenergieanlage in einem breiten Lastspektrum}, series = {Dresdner Maschinenelemente Kolloquium : DMK 2019 : 26.-27. Nov.}, booktitle = {Dresdner Maschinenelemente Kolloquium : DMK 2019 : 26.-27. Nov.}, publisher = {Sierke Verlag}, address = {G{\"o}ttingen}, isbn = {978-3-96548-055-1}, pages = {601 -- 616}, language = {de} } @article{BeyerWeigertQuicketal., author = {Beyer, Thomas and Weigert, Markus and Quick, Harald H. and Pietrzyk, Uwe and Vogt, Florian and Palm, Christoph and Antoch, Gerald and M{\"u}ller, Stefan P. and Bockisch, Andreas}, title = {MR-based attenuation correction for torso-PET/MR imaging}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {35}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {6}, doi = {10.1007/s00259-008-0734-0}, pages = {1142 -- 1146}, abstract = {Purpose MR-based attenuation correction (AC) will become an integral part of combined PET/MR systems. Here, we propose a toolbox to validate MR-AC of clinical PET/MRI data sets. Methods Torso scans of ten patients were acquired on a combined PET/CT and on a 1.5-T MRI system. MR-based attenuation data were derived from the CT following MR-CT image co-registration and subsequent histogram matching. PET images were reconstructed after CT- (PET/CT) and MR-based AC (PET/MRI). Lesion-to-background (L/B) ratios were estimated on PET/CT and PET/MRI. Results MR-CT histogram matching leads to a mean voxel intensity difference in the CT- and MR-based attenuation images of 12\% (max). Mean differences between PET/MRI and PET/CT were 19\% (max). L/B ratios were similar except for the lung where local misregistration and intensity transformation leads to a biased PET/MRI. Conclusion Our toolbox can be used to study pitfalls in MR-AC. We found that co-registration accuracy and pixel value transformation determine the accuracy of PET/MRI.}, subject = {Kernspintomografie}, language = {en} } @article{WeigertPietrzykMuelleretal., author = {Weigert, Markus and Pietrzyk, Uwe and M{\"u}ller, Stefan P. and Palm, Christoph and Beyer, Thomas}, title = {Whole-body PET/CT imaging}, series = {Zeitschrift f{\"u}r Medizinische Physik}, volume = {18}, journal = {Zeitschrift f{\"u}r Medizinische Physik}, number = {1}, doi = {10.1016/j.zemedi.2007.07.004}, pages = {59 -- 66}, abstract = {Aim Combined whole-body (WB) PET/CT imaging provides better overall co-registration compared to separate CT and PET. However, in clinical routine local PET-CT mis-registration cannot be avoided. Thus, the reconstructed PET tracer distribution may be biased when using the misaligned CT transmission data for CT-based attenuation correction (CT-AC). We investigate the feasibility of retrospective co-registration techniques to align CT and PET images prior to CT-AC, thus improving potentially the quality of combined PET/CT imaging in clinical routine. Methods First, using a commercial software registration package CT images were aligned to the uncorrected PET data by rigid and non-rigid registration methods. Co-registration accuracy of both alignment approaches was assessed by reviewing the PET tracer uptake patterns (visual, linked cursor display) following attenuation correction based on the original and co-registered CT. Second, we investigated non-rigid registration based on a prototype ITK implementation of the B-spline algorithm on a similar targeted MR-CT registration task, there showing promising results. Results Manual rigid, landmark-based co-registration introduced unacceptable misalignment, in particular in peripheral areas of the whole-body images. Manual, non-rigid landmark-based co-registration prior to CT-AC was successful with minor loco-regional distortions. Nevertheless, neither rigid nor non-rigid automatic co-registration based on the Mutual Information image to image metric succeeded in co-registering the CT and noAC-PET images. In contrast to widely available commercial software registration our implementation of an alternative automated, non-rigid B-spline co-registration technique yielded promising results in this setting with MR-CT data. Conclusion In clinical PET/CT imaging, retrospective registration of CT and uncorrected PET images may improve the quality of the AC-PET images. As of today no validated and clinically viable commercial registration software is in routine use. This has triggered our efforts in pursuing new approaches to a validated, non-rigid co-registration algorithm applicable to whole-body PET/CT imaging of which first results are presented here. This approach appears suitable for applications in retrospective WB-PET/CT alignment. Ziel Kombinierte PET/CT-Bildgebung erm{\"o}glicht verbesserte Koregistrierung von PET- und CT-Daten gegen{\"u}ber separat akquirierten Bildern. Trotzdem entstehen in der klinischen Anwendung lokale Fehlregistrierungen, die zu Fehlern in der rekonstruierten PET- Tracerverteilung f{\"u}hren k{\"o}nnen, falls die unregistrierten CT-Daten zur Schw{\"a}chungskorrektur (AC) der Emissionsdaten verwendet werden. Wir untersuchen daher die Anwendung von Bildregistrierungsalgorithmen vor der CT-basierten AC zur Verbesserung der PET-Aufnahmen. Methoden Mittels einer kommerziellen Registrierungssoftware wurden die CT-Daten eines PET/CT- Tomographen durch landmarken- und intensit{\"a}tsbasierte rigide (starre) und nicht-rigide Registrierungsverfahren r{\"a}umlich an die unkorrigierten PET-Emissionsdaten angepasst und zur AC verwendet. Zur Bewertung wurden die Tracerverteilungen in den PET-Bildern (vor AC, CT-AC, CT-AC nach Koregistrierung) visuell und mit Hilfe korrelierter Fadenkreuze verglichen. Zus{\"a}tzlich untersuchten wir die ITK-Implementierung der bekannten B-spline basierten, nicht-rigiden Registrierungsans{\"a}tze im Hinblick auf ihre Verwendbarkeit f{\"u}r die multimodale PET/CT-Ganzk{\"o}rperregistrierung. Ergebnisse Mittels landmarkenbasierter, nicht-rigider Registrierung konnte die Tracerverteilung in den PET-Daten lokal verbessert werden. Landmarkenbasierte rigide Registrierung f{\"u}hrte zu starker Fehlregistrierung in entfernten K{\"o}rperregionen. Automatische rigide und nicht-rigide Registrierung unter Verwendung der Mutual-Information-{\"A}hnlichkeitsmetrik versagte auf allen verwendeten Datens{\"a}tzen. Die automatische Registrierung mit B-spline-Funktionen zeigte vielversprechende Resultate in der Anwendung auf einem {\"a}hnlich gelagerten CT-MR-Registrierungsproblem. Fazit Retrospektive, nicht-rigide Registrierung unkorrigierter PET- und CT-Aufnahmen aus kombinierten Aufnahmensystemen vor der AC kann die Qualit{\"a}t von PET-Aufnahmen im klinischen Einsatz verbessern. Trotzdem steht bis heute im klinischen Alltag keine validierte, automatische Registrierungssoftware zur Verf{\"u}gung. Wir verfolgen dazu Ans{\"a}tze f{\"u}r validierte, nicht-rigide Bildregistrierung f{\"u}r den klinischen Einsatz und pr{\"a}sentieren erste Ergebnisse.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{DehnhardtPalmVietenetal., author = {Dehnhardt, Markus and Palm, Christoph and Vieten, Andrea and Bauer, Andreas and Pietrzyk, Uwe}, title = {Quantifying the A1AR distribution in peritumoral zones around experimental F98 and C6 rat brain tumours}, series = {Journal of Neuro-Oncology}, volume = {85}, journal = {Journal of Neuro-Oncology}, doi = {10.1007/s11060-007-9391-6}, pages = {49 -- 63}, abstract = {Quantification of growth in experimental F98 and C6 rat brain tumours was performed on 51 rat brains, 17 of which have been further assessed by 3D tumour reconstruction. Brains were cryosliced and radio-labelled with a ligand of the peripheral type benzodiazepine-receptor (pBR), 3H-Pk11195 [(1-(2-chlorophenyl)-N-methyl-N-(1-methyl-propylene)-3-isoquinoline-carboxamide)] by receptor autoradiography. Manually segmented and automatically registered tumours have been 3D-reconstructed for volumetric comparison on the basis of 3H-Pk11195-based tumour recognition. Furthermore automatically computed areas of -300 μm inner (marginal) zone as well as 300 μm and 600 μm outer tumour space were quantified. These three different regions were transferred onto other adjacent slices that had been labelled by receptor autoradiography with the A1 Adenosine receptor (A1AR)-ligand 3H-CPFPX (3H-8-cyclopentyl-3-(3-fluorpropyl)-1-propylxanthine) for quantitative assessment of A1AR in the three different tumour zones. Hence, a method is described for quantifying various receptor protein systems in the tumour as well as in the marginal invasive zones around experimentally implanted rat brain tumours and their representation in the tumour microenvironment as well as in 3D space. Furthermore, a tool for automatically reading out radio-labelled rat brain slices from auto radiographic films was developed, reconstructed into a consistent 3D-tumour model and the zones around the tumour were visualized. A1AR expression was found to depend upon the tumour volume in C6 animals, but is independent on the time of tumour development. In F98 animals, a significant increase in A1AR receptor protein was found in the Peritumoural zone as a function of time of tumour development and tumour volume.}, subject = {Hirntumor}, language = {en} } @article{MangSchnabelCrumetal., author = {Mang, Andreas and Schnabel, Julia A. and Crum, William R. and Modat, Marc and Camara-Rey, Oscar and Palm, Christoph and Caseiras, Gisele Brasil and J{\"a}ger, H. Rolf and Ourselin, S{\´e}bastien and Buzug, Thorsten M. and Hawkes, David J.}, title = {Consistency of parametric registration in serial MRI studies of brain tumor progression}, series = {International Journal of Computer Assisted Radiology and Surgery}, volume = {3}, journal = {International Journal of Computer Assisted Radiology and Surgery}, number = {3-4}, doi = {10.1007/s11548-008-0234-5}, pages = {201 -- 211}, abstract = {Object The consistency of parametric registration in multi-temporal magnetic resonance (MR) imaging studies was evaluated. Materials and methods Serial MRI scans of adult patients with a brain tumor (glioma) were aligned by parametric registration. The performance of low-order spatial alignment (6/9/12 degrees of freedom) of different 3D serial MR-weighted images is evaluated. A registration protocol for the alignment of all images to one reference coordinate system at baseline is presented. Registration results were evaluated for both, multimodal intra-timepoint and mono-modal multi-temporal registration. The latter case might present a challenge to automatic intensity-based registration algorithms due to ill-defined correspondences. The performance of our algorithm was assessed by testing the inverse registration consistency. Four different similarity measures were evaluated to assess consistency. Results Careful visual inspection suggests that images are well aligned, but their consistency may be imperfect. Sub-voxel inconsistency within the brain was found for allsimilarity measures used for parametric multi-temporal registration. T1-weighted images were most reliable for establishing spatial correspondence between different timepoints. Conclusions The parametric registration algorithm is feasible for use in this application. The sub-voxel resolution mean displacement error of registration transformations demonstrates that the algorithm converges to an almost identical solution for forward and reverse registration.}, subject = {Kernspintomografie}, language = {en} } @inproceedings{PalmGraemeCrumetal., author = {Palm, Christoph and Graeme, Penny P. and Crum, William R. and Schnabel, Julia A. and Pietrzyk, Uwe and Hawkes, David J.}, title = {Fusion of Rat Brain Histology and MRI using Weighted Multi-Image Mutual Information}, series = {Proceedings of the SPIE Medical Imaging 6914: Image Processing 69140M}, booktitle = {Proceedings of the SPIE Medical Imaging 6914: Image Processing 69140M}, number = {6914}, doi = {10.1117/12.770605}, pages = {69140M-1 -- 69140M-9}, abstract = {Fusion of histology and MRI is frequently demanded in biomedical research to study in vitro tissue properties in an in vivo reference space. Distortions and artifacts caused by cutting and staining of histological slices as well as differences in spatial resolution make even the rigid fusion a difficult task. State-of- the-art methods start with a mono-modal restacking yielding a histological pseudo-3D volume. The 3D information of the MRI reference is considered subsequently. However, consistency of the histology volume and consistency due to the corresponding MRI seem to be diametral goals. Therefore, we propose a novel fusion framework optimizing histology/histology and histology/MRI consistency at the same time finding a balance between both goals. Method - Direct slice-to-slice correspondence even in irregularly-spaced cutting sequences is achieved by registration-based interpolation of the MRI. Introducing a weighted multi-image mutual information metric (WI), adjacent histology and corresponding MRI are taken into account at the same time. Therefore, the reconstruction of the histological volume as well as the fusion with the MRI is done in a single step. Results - Based on two data sets with more than 110 single registrations in all, the results are evaluated quantitatively based on Tanimoto overlap measures and qualitatively showing the fused volumes. In comparison to other multi-image metrics, the reconstruction based on WI is significantly improved. We evaluated different parameter settings with emphasis on the weighting term steering the balance between intra- and inter-modality consistency.}, subject = {Kernspintomografie}, language = {en} } @inproceedings{EibenKunzPietrzyketal., author = {Eiben, Bj{\"o}rn and Kunz, Dietmar and Pietrzyk, Uwe and Palm, Christoph}, title = {Level-Set-Segmentierung von Rattenhirn MRTs}, series = {Bildverarbeitung f{\"u}r die Medizin 2009; Algorithmen - Systeme - Anwendungen ; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2009; Algorithmen - Systeme - Anwendungen ; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, publisher = {Springer}, address = {Berlin}, pages = {167 -- 171}, abstract = {In dieser Arbeit wird die Segmentierung von Gehirngewebe aus Kopfaufnahmen von Ratten mittels Level-Set-Methoden vorgeschlagen. Dazu wird ein zweidimensionaler, kontrastbasierter Ansatz zu einem dreidimensionalen, lokal an die Bildintensit{\"a}t adaptierten Segmentierer erweitert. Es wird gezeigt, dass mit diesem echten 3D-Ansatz die lokalen Bildstrukturen besser ber{\"u}cksichtigt werden k{\"o}nnen. Insbesondere Magnet-Resonanz-Tomographien (MRTs) mit globalen Helligkeitsgradienten, beispielsweise bedingt durch Oberfl{\"a}chenspulen, k{\"o}nnen auf diese Weise zuverl{\"a}ssiger und ohne weitere Vorverarbeitungsschritte segmentiert werden. Die Leistungsf{\"a}higkeit des Algorithmus wird experimentell an Hand dreier Rattenhirn-MRTs demonstriert.}, subject = {Dreidimensionale Bildverarbeitung}, language = {de} } @inproceedings{PietrzykPalmBeyer, author = {Pietrzyk, Uwe and Palm, Christoph and Beyer, Thomas}, title = {Investigation of fusion strategies of multi-modality images}, series = {IEEE Nuclear Science Symposium Conference Record}, volume = {4}, booktitle = {IEEE Nuclear Science Symposium Conference Record}, doi = {10.1109/NSSMIC.2004.1462740}, pages = {2399 -- 2401}, abstract = {Presenting images from different modalities seems to be a trivial task considering the challenges to obtain registered images as a pre-requisite for image fusion. In combined tomographs like PET/CT, image registration is intrinsic. However, informative image fusion mandates careful preparation owing to the large amount of information that is presented to the observer. In complex imaging situations it is required to provide tools that are easy to handle and still powerful enough to help the observer discriminating important details from background patterns. We investigated several options for color tables applied to brain and non-brain images obtained with PET, MRI and CT.}, language = {en} } @misc{BauerStoffelsPauleitetal., author = {Bauer, Dagmar and Stoffels, Gabriele and Pauleit, Dirk and Palm, Christoph and Hamacher, Kurt and Coenen, Heinz H. and Langen, Karl}, title = {Uptake of F-18-fluoroethyl-L-tyrosine and H-3-L-methionine in focal cortical ischemia}, series = {The Journal of Nuclear Medicine}, volume = {47}, journal = {The Journal of Nuclear Medicine}, number = {Suppl. 1}, pages = {284P}, abstract = {Objectives: C-11-methionine (MET) is particularly useful in brain tumor diagnosis but unspecific uptake e.g. in cerebral ischemia has been reported (1). The F-18-labeled amino acid O-(2-[F-18]fluoroethyl)-L-tyrosine (FET) shows a similar clinical potential as MET in brain tumor diagnosis but is applicable on a wider clinical scale. The aim of this study was to evaluate the uptake of FET and H-3-MET in focal cortical ischemia in rats by dual tracer autoradiography. Methods: Focal cortical ischemia was induced in 12 Fisher CDF rats using the photothrombosis model (PT). One day (n=3) , two days (n=5) and 7 days (n=4) after induction of the lesion FET and H-3-MET were injected intravenously. One hour after tracer injection animals were killed, the brains were removed immediately and frozen in 2-methylbutane at -50°C. Brains were cut in coronal sections (thickness: 20 µm) and exposed first to H-3 insensitive photoimager plates to measure FET distribution. After decay of F-18 the distribution of H-3-MET was determined. The autoradiograms were evaluated by regions of interest (ROIs) placed on areas with increased tracer uptake in the PT and the contralateral brain. Lesion to brain ratios (L/B) were calculated by dividing the mean uptake in the lesion and the brain. Based on previous studies in gliomas a L/B ratio > 1.6 was considered as pathological for FET. Results: Variable increased uptake of both tracers was observed in the PT and its demarcation zone at all stages after PT. The cut-off level of 1.6 for FET was exceeded in 9/12 animals. One day after PT the L/B ratios were 2.0 ± 0.6 for FET vs. 2.1 ± 1.0 for MET (mean ± SD); two days after lesion 2.2 ± 0.7 for FET vs. 2.7 ± 1.0 for MET and 7 days after lesion 2.4 ± 0.4 for FET vs. 2.4 ± 0.1 for MET. In single cases discrepancies in the uptake pattern of FET and MET were observed. Conclusions: FET like MET may exhibit significant uptake in infarcted areas or the immediate vincinity which has to be considered in the differential diagnosis of unkown brain lesions. The discrepancies in the uptake pattern of FET and MET in some cases indicates either differences in the transport mechanisms of both amino acids or a different affinity for certain cellular components.}, language = {en} } @article{MatuschDepboyluPalmetal., author = {Matusch, Andreas and Depboylu, Candan and Palm, Christoph and Wu, Bei and H{\"o}glinger, G{\"u}nter U. and Sch{\"a}fer, Martin K.-H. and Becker, Johanna Sabine}, title = {Cerebral bio-imaging of Cu, Fe, Zn and Mn in the MPTP mouse model of Parkinsons disease using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)}, series = {Journal of the American Society for Mass Spectrometry}, volume = {21}, journal = {Journal of the American Society for Mass Spectrometry}, number = {1}, doi = {10.1016/j.jasms.2009.09.022}, pages = {161 -- 171}, abstract = {Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a powerful technique for the determination of metal and nonmetal distributions within biological systems with high sensitivity. An imaging LA-ICP-MS technique for Fe, Cu, Zn, and Mn was developed to produce large series of quantitative element maps in native brain sections of mice subchronically intoxicated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridin (MPTP) as a model of Parkinson's disease. Images were calibrated using matrix-matched laboratory standards. A software solution allowing a precise delineation of anatomical structures was implemented. Coronal brain sections were analyzed crossing the striatum and the substantia nigra, respectively. Animals sacrificed 2 h, 7 d, or 28 d after the last MPTP injection and controls were investigated. We observed significant decreases of Cu concentrations in the periventricular zone and the fascia dentata at 2 h and 7d and a recovery or overcompensation at 28 d, most pronounced in the rostral periventricular zone (+40\%). In the cortex Cu decreased slightly to -10\%. Fe increased in the interpeduncular nucleus (+40\%) but not in the substantia nigra. This pattern is in line with a differential regulation of periventricular and parenchymal Cu, and with the histochemical localization of Fe, and congruent to regions of preferential MPTP binding described in the rodent brain. The LA-ICP-MS technique yielded valid and statistically robust results in the present study on 39 slices from 19 animals. Our findings underline the value of routine micro-local analytical techniques in the life sciences and affirm a role of Cu availability in Parkinson's disease.}, subject = {ICP-Massenspektrometrie}, language = {en} } @article{BeckerMatuschPalmetal., author = {Becker, Johanna Sabine and Matusch, Andreas and Palm, Christoph and Salber, Dagmar and Morton, Kathryn A. and Becker, Julia Susanne}, title = {Bioimaging of metals in brain tissue by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and metallomics}, series = {Metallomics}, journal = {Metallomics}, number = {2}, publisher = {Oxford Academic Press}, doi = {10.1039/b916722f}, pages = {104 -- 111}, abstract = {Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been developed and established as an emerging technique in the generation of quantitative images of metal distributions in thin tissue sections of brain samples (such as human, rat and mouse brain), with applications in research related to neurodegenerative disorders. A new analytical protocol is described which includes sample preparation by cryo-cutting of thin tissue sections and matrix-matched laboratory standards, mass spectrometric measurements, data acquisition, and quantitative analysis. Specific examples of the bioimaging of metal distributions in normal rodent brains are provided. Differences to the normal were assessed in a Parkinson's disease and a stroke brain model. Furthermore, changes during normal aging were studied. Powerful analytical techniques are also required for the determination and characterization of metal-containing proteins within a large pool of proteins, e.g., after denaturing or non-denaturing electrophoretic separation of proteins in one-dimensional and two-dimensional gels. LA-ICP-MS can be employed to detect metalloproteins in protein bands or spots separated after gel electrophoresis. MALDI-MS can then be used to identify specific metal-containing proteins in these bands or spots. The combination of these techniques is described in the second section.}, subject = {ICP-Massenspektrometrie}, language = {en} } @inproceedings{PalmPietrzyk, author = {Palm, Christoph and Pietrzyk, Uwe}, title = {Time-Dependent Joint Probability Speed Function for Level-Set Segmentation of Rat-Brain Slices}, series = {Proceedings of the SPIE Medical Imaging 6914: Image Processing 69143U}, booktitle = {Proceedings of the SPIE Medical Imaging 6914: Image Processing 69143U}, number = {6914}, doi = {10.1117/12.770673}, pages = {69143U-1 -- 69143U-8}, abstract = {The segmentation of rat brain slices suffers from illumination inhomogeneities and staining effects. State-of-the-art level-set methods model slice and background with intensity mixture densities defining the speed function as difference between the respective probabilites. Nevertheless, the overlap of these distributions causes an inaccurate stopping at the slice border. In this work, we propose the characterisation of the border area with intensity pairs for inside and outside estimating joint intensity probabilities. Method - In contrast to global object and background models, we focus on the object border characterised by a joint mixture density. This specifies the probability of the occurance of an inside and an outside value in direct adjacency. These values are not known beforehand, because inside and outside depend on the level-set evolution and change during time. Therefore, the speed function is computed time-dependently at the position of the current zero level-set. Along this zero level-set curve, the inside and outside values are derived as mean along the curvature normal directing inside and outside the object. Advantage of the joint probability distribution is to resolve the distribution overlaps, because these are assumed to be not located at the same border position. Results - The novel time-dependent joint probability based speed function is compared expermimentally with single probability based speed functions. Two rat brains with about 40 slices are segmented and the results analysed using manual segmentations and the Tanimoto overlap measure. Improved results are recognised for both data sets.}, subject = {Kernspintomografie}, language = {en} } @inproceedings{SchubertPietrzykReisseletal., author = {Schubert, Nicole and Pietrzyk, Uwe and Reißel, Martin and Palm, Christoph}, title = {Reduktion von Rissartefakten durch nicht-lineare Registrierung in histologischen Schnittbildern}, series = {Bildverarbeitung f{\"u}r die Medizin 2009; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2009; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, publisher = {Springer}, address = {Berlin}, pages = {410 -- 414}, abstract = {In dieser Arbeit wird ein Verfahren vorgestellt, das Rissartefakte, die in histologischen Rattenhirnschnitten vorkommen k{\"o}nnen, durch nicht-lineare Registrierung reduziert. Um die Optimierung in der Rissregion zu leiten, wird der Curvature Registrierungsansatz um eine Metrik basierend auf der Segmentierung der Bilder erweitert. Dabei erzielten Registrierungen mit der ausschließlichen Segmentierung des Risses bessere Ergebnisse als Registrierungen mit einer Segmentierung des gesamten Hirnschnitts. Insgesamt zeigt sich eine deutliche Verbesserung in der Rissregion, wobei der verbleibende reduzierte Riss auf die Glattheitsbedingungen des Regularisierers zur{\"u}ckzuf{\"u}hren ist.}, subject = {Registrierung }, language = {de} } @article{BeckerZoriyMatuschetal., author = {Becker, Johanna Sabine and Zoriy, Miroslav and Matusch, Andreas and Wu, Bei and Salber, Dagmar and Palm, Christoph and Becker, Julia Susanne}, title = {Bioimaging of Metals by Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS)}, series = {Mass Spectrometry Reviews}, volume = {29}, journal = {Mass Spectrometry Reviews}, doi = {10.1002/mas.20239}, pages = {156 -- 175}, abstract = {The distribution analysis of (essential, beneficial, or toxic) metals (e.g., Cu, Fe, Zn, Pb, and others), metalloids, and non-metals in biological tissues is of key interest in life science. Over the past few years, the development and application of several imaging mass spectrometric techniques has been rapidly growing in biology and medicine. Especially, in brain research metalloproteins are in the focus of targeted therapy approaches of neurodegenerative diseases such as Alzheimer's and Parkinson's disease, or stroke, or tumor growth. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) using double-focusing sector field (LA-ICP-SFMS) or quadrupole-based mass spectrometers (LA-ICP-QMS) has been successfully applied as a powerful imaging (mapping) technique to produce quantitative images of detailed regionally specific element distributions in thin tissue sections of human or rodent brain. Imaging LA-ICP-QMS was also applied to investigate metal distributions in plant and animal sections to study, for example, the uptake and transport of nutrient and toxic elements or environmental contamination. The combination of imaging LA-ICP-MS of metals with proteomic studies using biomolecular mass spectrometry identifies metal-containing proteins and also phosphoproteins. Metal-containing proteins were imaged in a two-dimensional gel after electrophoretic separation of proteins (SDS or Blue Native PAGE). Recent progress in LA-ICP-MS imaging as a stand-alone technique and in combination with MALDI/ESI-MS for selected life science applications is summarized.}, subject = {Bildgebendes Verfahren}, language = {en} } @article{IlgnerPalmSchuetzetal., author = {Ilgner, Justus F. R. and Palm, Christoph and Sch{\"u}tz, Andreas G. and Spitzer, Klaus and Westhofen, Martin and Lehmann, Thomas M.}, title = {Colour Texture Analysis for Quantitative Laryngoscopy}, series = {Acta Otolaryngologica}, volume = {123}, journal = {Acta Otolaryngologica}, doi = {10.1080/00016480310000412}, pages = {730 -- 734}, abstract = {Whilst considerable progress has been made in enhancing the quality of indirect laryngoscopy and image processing, the evaluation of clinical findings is still based on the clinician's judgement. The aim of this paper was to examine the feasibility of an objective computer-based method for evaluating laryngeal disease. Digitally recorded images obtained by 90 degree- and 70 degree-angled indirect rod laryngoscopy using standardized white balance values were made of 16 patients and 19 healthy subjects. The digital images were evaluated manually by the clinician based on a standardized questionnaire, and suspect lesions were marked and classified on the image. Following colour separation, normal vocal cord areas as well as suspect lesions were analyzed automatically using co-occurrence matrices, which compare colour differences between neighbouring pixels over a predefined distance. Whilst colour histograms did not provide sufficient information for distinguishing between healthy and diseased tissues, consideration of the blue content of neighbouring pixels enabled a correct classification in 81.4\% of cases. If all colour channels (red, green and blue) were regarded simultaneously, the best classification correctness obtained was 77.1\%. Although only a very basic classification differentiating between healthy and diseased tissue was attempted, the results showed progress compared to grey-scale histograms, which have been evaluated before. The results document a first step towards an objective, machine-based classification of laryngeal images, which could provide the basis for further development of an expert system for use in indirect laryngoscopy.}, language = {en} } @article{PalmVietenSalberetal., author = {Palm, Christoph and Vieten, Andrea and Salber, Dagmar and Pietrzyk, Uwe}, title = {Evaluation of Registration Strategies for Multi-modality Images of Rat Brain Slices}, series = {Physics in Medicine and Biology}, volume = {54}, journal = {Physics in Medicine and Biology}, number = {10}, doi = {10.1088/0031-9155/54/10/021}, pages = {3269 -- 3289}, abstract = {In neuroscience, small-animal studies frequently involve dealing with series of images from multiple modalities such as histology and autoradiography. The consistent and bias-free restacking of multi-modality image series is obligatory as a starting point for subsequent non-rigid registration procedures and for quantitative comparisons with positron emission tomography (PET) and other in vivo data. Up to now, consistency between 2D slices without cross validation using an inherent 3D modality is frequently presumed to be close to the true morphology due to the smooth appearance of the contours of anatomical structures. However, in multi-modality stacks consistency is difficult to assess. In this work, consistency is defined in terms of smoothness of neighboring slices within a single modality and between different modalities. Registration bias denotes the distortion of the registered stack in comparison to the true 3D morphology and shape. Based on these metrics, different restacking strategies of multi-modality rat brain slices are experimentally evaluated. Experiments based on MRI-simulated and real dual-tracer autoradiograms reveal a clear bias of the restacked volume despite quantitatively high consistency and qualitatively smooth brain structures. However, different registration strategies yield different inter-consistency metrics. If no genuine 3D modality is available, the use of the so-called SOP (slice-order preferred) or MOSOP (modality-and-slice-order preferred) strategy is recommended.}, subject = {Histologie}, language = {en} } @inproceedings{EibenPalmPietrzyketal., author = {Eiben, Bj{\"o}rn and Palm, Christoph and Pietrzyk, Uwe and Davatzikos, Christos and Amunts, Katrin}, title = {Error Correction using Registration for Blockface Volume Reconstruction of Serial Histological Sections of the Human Brain}, series = {Bildverarbeitung f{\"u}r die Medizin 2010; Algorithmen - Systeme - Anwendungen ; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2010; Algorithmen - Systeme - Anwendungen ; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, publisher = {Springer}, address = {Berlin}, pages = {301 -- 305}, abstract = {For accurate registration of histological sections blockface images are frequently used as three dimensional reference. However, due to the use of endocentric lenses the images suffer from perspective errors such as scaling and seemingly relative movement of planes which are located in different distances parallel to the imaging sensor. The suggested correction of those errors is based on the estimation of scaling factors derived from image registration of regions characterized by differing distances to the point of view in neighboring sections. The correction allows the generation of a consistent three dimensional blockface volume.}, subject = {Histologie}, language = {en} } @misc{BeyerWeigertPalmetal., author = {Beyer, Thomas and Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Vogt, Florian and Martinez, M.J. and Bockisch, Andreas}, title = {Towards MR-based attenuation correction for whole-body PET/MR imaging}, series = {The Journal of Nuclear Medicine}, volume = {47}, journal = {The Journal of Nuclear Medicine}, number = {Suppl. 1}, pages = {384P}, subject = {Kernspintomografie}, language = {en} } @misc{GraesselAxerPalmetal., author = {Gr{\"a}ßel, David and Axer, Markus and Palm, Christoph and Dammers, J{\"u}rgen and Amunts, Katrin and Pietrzyk, Uwe and Zilles, Karl}, title = {Visualization of Fiber Tracts in the Postmortem Human Brain by Means of Polarized Light}, series = {NeuroImage}, volume = {47}, journal = {NeuroImage}, number = {Suppl. 1}, doi = {10.1016/S1053-8119(09)71415-6}, pages = {142}, subject = {Gehirn}, language = {en} } @misc{WeigertBeyerQuicketal., author = {Weigert, Markus and Beyer, Thomas and Quick, Harald H. and Pietrzyk, Uwe and Palm, Christoph and M{\"u}ller, Stefan P.}, title = {Generation of a MRI reference data set for the validation of automatic, non-rigid image co-registration algorithms}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A116}, subject = {Kernspintomografie}, language = {en} } @inproceedings{PietrzykBauerVietenetal., author = {Pietrzyk, Uwe and Bauer, Dagmar and Vieten, Andrea and Bauer, Andreas and Langen, Karl-Josef and Zilles, Karl and Palm, Christoph}, title = {Creating consistent 3D multi-modality data sets from autoradiographic and histological images of the rat brain}, series = {IEEE Nuclear Science Symposium Conference Record}, volume = {6}, booktitle = {IEEE Nuclear Science Symposium Conference Record}, doi = {10.1109/NSSMIC.2004.1466754}, pages = {4001 -- 4003}, abstract = {Volumetric representations of autoradiographic and histological images gain ever more interest as a base to interpret data obtained with /spl mu/-imaging devices like microPET. Beyond supporting spatial orientation within rat brains especially autoradiographic images may serve as a base to quantitatively evaluate the complex uptake patterns of microPET studies with receptor ligands or tumor tracers. They may also serve for the development of rat brain atlases or data models, which can be explored during further image analysis or simulation studies. In all cases a consistent spatial representation of the rat brain, i.e. its anatomy and the corresponding quantitative uptake pattern, is required. This includes both, a restacking of the individual two-dimensional images and the exact registration of the respective volumes. We propose strategies how these volumes can be created in a consistent way and trying to limit the requirements on the circumstances during data acquisition, i.e. being independent from other sources like video imaging of the block face prior to cutting or high resolution micro-X-ray CT or micro MRI.}, language = {en} } @article{BauerHamacherBroeeretal., author = {Bauer, Dagmar and Hamacher, Kurt and Br{\"o}er, Stefan and Pauleit, Dirk and Palm, Christoph and Zilles, Karl and Coenen, Heinz H. and Langen, Karl-Josef}, title = {Preferred stereoselective brain uptake of D-serine}, series = {Nuclear Medicine and Biology}, volume = {32}, journal = {Nuclear Medicine and Biology}, number = {8}, doi = {10.1016/j.nucmedbio.2005.07.004}, pages = {793 -- 797}, abstract = {Although it has long been presumed that d-amino acids are uncommon in mammalians, substantial amounts of free d-serine have been detected in the mammalian brain. d-Serine has been demonstrated to be an important modulator of glutamatergic neurotransmission and acts as an agonist at the strychnine-insensitive glycine site of N-methyl-d-aspartate receptors. The blood-to-brain transfer of d-serine is thought to be extremely low, and it is assumed that d-serine is generated by isomerization of l-serine in the brain. Stimulated by the observation of a preferred transport of the d-isomer of proline at the blood-brain barrier, we investigated the differential uptake of [3H]-d-serine and [3H]-l-serine in the rat brain 1 h after intravenous injection using quantitative autoradiography. Surprisingly, brain uptake of [3H]-d-serine was significantly higher than that of [3H]-l-serine, indicating a preferred transport of the d-enantiomer of serine at the blood-brain barrier. This finding indicates that exogenous d-serine may have a direct influence on glutamatergic neurotransmission and associated diseases.}, subject = {Aminos{\"a}uren}, language = {en} } @article{LehmannPalm, author = {Lehmann, Thomas M. and Palm, Christoph}, title = {Color Line Search for Illuminant Estimation in Real World Scenes}, series = {Journal of the Optical Society of America (JOSA) A}, volume = {18}, journal = {Journal of the Optical Society of America (JOSA) A}, number = {11}, doi = {10.1364/JOSAA.18.002679}, pages = {2679 -- 2691}, abstract = {The estimation of illuminant color is mandatory for many applications in the field of color image quantification. However, it is an unresolved problem if no additional heuristics or restrictive assumptions apply. Assuming uniformly colored and roundly shaped objects, Lee has presented a theory and a method for computing the scene-illuminant chromaticity from specular highlights [H. C. Lee, J. Opt. Soc. Am. A 3, 1694 (1986)]. However, Lee's method, called image path search, is less robust to noise and is limited in the handling of microtextured surfaces. We introduce a novel approach to estimate the color of a single illuminant for noisy and microtextured images, which frequently occur in real-world scenes. Using dichromatic regions of different colored surfaces, our approach, named color line search, reverses Lee's strategy of image path search. Reliable color lines are determined directly in the domain of the color diagrams by three steps. First, regions of interest are automatically detected around specular highlights, and local color diagrams are computed. Second, color lines are determined according to the dichromatic reflection model by Hough transform of the color diagrams. Third, a consistency check is applied by a corresponding path search in the image domain. Our method is evaluated on 40 natural images of fruit and vegetables. In comparison with those of Lee's method, accuracy and stability are substantially improved. In addition, the color line search approach can easily be extended to scenes of objects with macrotextured surfaces.}, language = {en} } @article{Palm, author = {Palm, Christoph}, title = {Color Texture Classification by Integrative Co-Occurrence Matrices}, series = {Pattern Recognition}, volume = {37}, journal = {Pattern Recognition}, number = {5}, doi = {10.1016/j.patcog.2003.09.010}, pages = {965 -- 976}, abstract = {Integrative Co-occurrence matrices are introduced as novel features for color texture classification. The extended Co-occurrence notation allows the comparison between integrative and parallel color texture concepts. The information profit of the new matrices is shown quantitatively using the Kolmogorov distance and by extensive classification experiments on two datasets. Applying them to the RGB and the LUV color space the combined color and intensity textures are studied and the existence of intensity independent pure color patterns is demonstrated. The results are compared with two baselines: gray-scale texture analysis and color histogram analysis. The novel features improve the classification results up to 20\% and 32\% for the first and second baseline, respectively.}, language = {en} } @inproceedings{PalmVietenBaueretal., author = {Palm, Christoph and Vieten, Andrea and Bauer, Dagmar and Pietrzyk, Uwe}, title = {Evaluierung von Registrierungsstrategien zur multimodalen 3D-Rekonstruktion von Rattenhirnschnitten}, series = {Bildverarbeitung f{\"u}r die Medizin 2006}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2006}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/3-540-32137-3_51}, pages = {251 -- 255}, abstract = {In dieser Arbeit werden drei Strategien zur 3D Stapelung von multimodalen Schnittbildern vorgestellt. Die Strategien werden experimentell anhand von Dualtracer-Autoradiographien evaluiert. Dazu werden neue Maße zur Beschreibung der Konsistenz innerhalb einer Modalit{\"a}t und der Konsistenz der Modalit{\"a}ten untereinander entwickelt, die auf bekannten Registrierungsmetriken basieren. Gerade bez{\"u}glich der Konsistenz der Modalit{\"a}ten untereinander zeigen zwei Strategien die besten Resultate: (1) abwechselnde multimodale Registrierung (2) monomodale Rekonstruktion einer Modalit{\"a}t und multimodale 2D Registrierung der zweiten Modalit{\"a}t.}, subject = {Registrierung }, language = {de} } @inproceedings{PietrzykPalmBeyer, author = {Pietrzyk, Uwe and Palm, Christoph and Beyer, Thomas}, title = {Fusion strategies in multi-modality imaging}, series = {Medical Physics, Vol 2. Proceedings of the jointly held Congresses: ICMP 2005, 14th International Conference of Medical Physics of the International Organization for Medical Physics (IOMP), the European Federation of Organizations in Medical Physics (EFOMP) and the German Society of Medical Physics (DGMP) ; BMT 2005, 39th Annual Congress of the German Society for Biomedical Engineering (DGBMT) within VDE ; 14th - 17th September 2005, Nuremberg, Germany}, booktitle = {Medical Physics, Vol 2. Proceedings of the jointly held Congresses: ICMP 2005, 14th International Conference of Medical Physics of the International Organization for Medical Physics (IOMP), the European Federation of Organizations in Medical Physics (EFOMP) and the German Society of Medical Physics (DGMP) ; BMT 2005, 39th Annual Congress of the German Society for Biomedical Engineering (DGBMT) within VDE ; 14th - 17th September 2005, Nuremberg, Germany}, pages = {1446 -- 1447}, subject = {Bildgebendes Verfahren}, language = {en} } @misc{WeigertPalmQuicketal., author = {Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Beyer, Thomas}, title = {Template for MR-based attenuation correction for whole-body PET/MR imaging}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A115}, subject = {Kernspintomografie}, language = {en} } @misc{AxerAxerPalmetal., author = {Axer, Markus and Axer, Hubertus and Palm, Christoph and Gr{\"a}ßel, David and Zilles, Karl and Pietrzyk, Uwe}, title = {Visualization of Nerve Fibre Orientation in the Visual Cortex of the Human Brain by Means of Polarized Light}, series = {Biomedizinische Technik}, volume = {52}, journal = {Biomedizinische Technik}, number = {Suppl.}, pages = {1569048-041}, subject = {Sehrinde}, language = {en} } @inproceedings{PalmDehnhardtVietenetal., author = {Palm, Christoph and Dehnhardt, Markus and Vieten, Andrea and Pietrzyk, Uwe}, title = {3D rat brain tumor reconstruction}, series = {Biomedizinische Technik}, volume = {50}, booktitle = {Biomedizinische Technik}, number = {Suppl. 1, Part 1}, pages = {597 -- 598}, subject = {Dreidimensionale Rekonstruktion}, language = {en} } @misc{PalmCrumPietrzyketal., author = {Palm, Christoph and Crum, William R. and Pietrzyk, Uwe and Hawkes, David J.}, title = {Application of Fluid and Elastic Registration Methods to Histological Rat Brain Sections}, series = {Biomedizinische Technik}, volume = {52}, journal = {Biomedizinische Technik}, number = {Suppl.}, pages = {1569048-859}, subject = {Registrierung }, language = {en} } @inproceedings{PalmLehmannBrednoetal., author = {Palm, Christoph and Lehmann, Thomas M. and Bredno, J. and Neuschaefer-Rube, C. and Klajman, S. and Spitzer, Klaus}, title = {Automated Analysis of Stroboscopic Image Sequences by Vibration Profiles}, series = {Advances in Quantitative Laryngoscopy, Voice and Speech Research, Procs. 5th International Workshop}, booktitle = {Advances in Quantitative Laryngoscopy, Voice and Speech Research, Procs. 5th International Workshop}, abstract = {A method for automated segmentation of vocal cords in stroboscopic video sequences is presented. In contrast to earlier approaches, the inner and outer contours of the vocal cords are independently delineated. Automatic segmentation of the low contrasted images is carried out by connecting the shape constraint of a point distribution model to a multi-channel regionbased balloon model. This enables us to robustly compute a vibration profile that is used as a new diagnostic tool to visualize several vibration parameters in only one graphic. The vibration profiles are studied in two cases: one physiological vibration and one functional pathology.}, language = {en} } @inproceedings{PalmFischerLehmannetal., author = {Palm, Christoph and Fischer, B. and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Hierarchische Wasserscheiden-Transformation zur Lippensegmentierung in Farbbildern}, series = {Bildverarbeitung f{\"u}r die Medizin 2000}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2000}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/978-3-642-59757-2_20}, pages = {106 -- 110}, abstract = {Zur L{\"o}sung komplexer Segmentierungsprobleme wird eine hierarchische und farbbasierte Wasserscheidentransformation vorgestellt. Geringe Modifikationen bez{\"u}glich Startpunktwahl und Flutungsprozess resultieren in signifikanten Verbesserungen der Segmentierung. Das Verfahren wurde zur Lippendetektion in Farbbildsequenzen eingesetzt, die zur quantitativen Beschreibung von Sprechbewegungsabl{\"a}ufen automatisch ausgewertet werden. Die Experimente mit 245 Bildern aus 6 Sequenzen zeigten eine Fehlerrate von 13\%.}, language = {de} } @inproceedings{PalmLehmannSpitzer, author = {Palm, Christoph and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Color Texture Analysis of Moving Vocal Cords Using Approaches from Statistics and Signal Theory}, series = {Advances in Quantitative Laryngoscopy, Voice and Speech Research, Procs. 4th International Workshop, Friedrich Schiller University, Jena}, booktitle = {Advances in Quantitative Laryngoscopy, Voice and Speech Research, Procs. 4th International Workshop, Friedrich Schiller University, Jena}, pages = {49 -- 56}, abstract = {Textural features are applied for detection of morphological pathologies of vocal cords. Cooccurrence matrices as statistical features are presented as well as filter bank analysis by Gabor filters. Both methods are extended to handle color images. Their robustness against camera movement and vibration of vocal cords is evaluated. Classification results due to three in vivo sequences are in between 94.4 \% and 98.9\%. The classification errors decrease if color features are used instead of grayscale features for both statistical and Fourier features}, language = {en} } @article{NeuschaeferRubeLehmannPalmetal., author = {Neuschaefer-Rube, C. and Lehmann, Thomas M. and Palm, Christoph and Bredno, J. and Klajman, S. and Spitzer, Klaus}, title = {3D-Visualisierung glottaler Abduktionsbewegungen}, series = {Aktuelle phoniatrisch-p{\"a}daudiologische Aspekte}, volume = {2001/2002}, journal = {Aktuelle phoniatrisch-p{\"a}daudiologische Aspekte}, number = {9}, publisher = {Median}, isbn = {3-922766-76-5}, pages = {58 -- 61}, language = {de} } @inproceedings{FischerPalmLehmannetal., author = {Fischer, B. and Palm, Christoph and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Selektion von Farbtexturmerkmalen zur Tumorklassifikation dermatoskopischer Fotografien}, series = {Bildverarbeitung f{\"u}r die Medizin 2002}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2002}, publisher = {Springer}, address = {Berlin}, pages = {238 -- 241}, language = {de} } @book{Palm, author = {Palm, Christoph}, title = {Integrative Auswertung von Farbe und Textur}, publisher = {Der Andere Verlag}, language = {de} } @article{PalmDehnhardtVietenetal., author = {Palm, Christoph and Dehnhardt, Markus and Vieten, Andrea and Pietrzyk, Uwe and Bauer, Andreas and Zilles, Karl}, title = {3D rat brain tumors}, series = {Naunyn-Schmiedebergs Archives of Pharmacology}, volume = {371}, journal = {Naunyn-Schmiedebergs Archives of Pharmacology}, number = {R103}, language = {en} } @inproceedings{PalmSchollLehmannetal., author = {Palm, Christoph and Scholl, Ingrid and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Nutzung eines Farbkonstanz-Algorithmus zur Entfernung von Glanzlichtern in laryngoskopischen Bildern}, series = {Methoden der Medizinischen Informatik, Biometrie und Epidemiologie in der modernen Informationsgesellschaft}, booktitle = {Methoden der Medizinischen Informatik, Biometrie und Epidemiologie in der modernen Informationsgesellschaft}, editor = {Greiser, E. and Wischnewsky, M.}, publisher = {MMV Medien und Medizin}, address = {M{\"u}nchen}, isbn = {9783820813357}, pages = {300 -- 303}, abstract = {1 Einf{\"u}hrung Funktionelle und organische St{\"o}rungen im Larynx beeintr{\"a}chtigen die Ausdrucksf{\"a}higkeit des Menschen. Zur Diagnostik und Verlaufkontrolle werden die Stimmlippen im Larynx mit Hilfe der Video-Laryngoskopie aufgenommen. Zur optimalen Farbmessung wird dazu an das Lupenendoskop eine 3-Chip-CCD-Kamera angeschlossen, die eine unabh{\"a}ngige Aufnahme der drei Farbkan{\"a}le erlaubt. Die bisherige subjektive Befundung ist von der Erfahrung des Untersuchers abh{\"a}ngig und l{\"a}ßt nur eine grobe Klassifikation der Krankheitsbilder zu. Zur Objektivierung werden daher quantitative Parameter f{\"u}r Farbe, Textur und Schwingung entwickelt. Neben dem Einfluß der wechselnden Lichtquellenfarbe auf den Farbeindruck ist die Sekretauflage auf den Stimmlippen ein Problem bei der Farb-und Texturanalyse. Sie kann zu ausgedehnten Glanzlichtern f{\"u}hren und so weite Bereiche der Stimmlippen f{\"u}r die Farb-und Texturanalyse unbrauchbar machen. Dieser Beitrag stellt einen Farbkonstanz-Algorithmus vor, der unabh{\"a}ngig von der Lichtquelle quantitative Farbwerte des Gewebes liefert und die Glanzlichtdetektion und -elimination erm{\"o}glicht. 2 Methodik Ziel des Farbkonstanz-Algorithmus ist die Trennung von Lichtquellen-und Gewebefarbe. Unter Verwendung des dichromatischen Reflexionsmodells [1] kann die Oberfl{\"a}chenreflexion mit der Farbe der Lichtquelle und die K{\"o}rperreflexion mit der Gewebefarbe identifiziert werden. Der Farbeindruck entsteht aus der Linearkombination beider Farbkomponenten. Ihre Gewichtung ist von der Aufnahmegeometrie abh{\"a}ngig, insbesondere vom Winkel zwischen Oberfl{\"a}chennormalen und dem Positionsvektor der Lichtquelle. In einem zweistufigen Verfahren wird zun{\"a}chst die Lichtquellenfarbe gesch{\"a}tzt, dann die Gewebefarbe ermittelt. Hieraus k{\"o}nnen beide Farbanteile durch die Berechnung der Gewichtsfaktoren pixelweise getrennt werden.}, language = {de} } @inproceedings{PalmLehmannSpitzer, author = {Palm, Christoph and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Bestimmung der Lichtquellenfarbe bei der Endoskopie mikrotexturierter Oberfl{\"a}chen des Kehlkopfes}, series = {5. Workshop Farbbildverarbeitung, Ilmenau, 1999}, booktitle = {5. Workshop Farbbildverarbeitung, Ilmenau, 1999}, pages = {3 -- 10}, abstract = {Zur Unterst{\"u}tzung der Diagnose von Stimmlippenerkrankungen werden innerhalb des Forschungsprojektes Quantitative Digitale Laryngoskopie objektive Parameter zur Beschreibung der Bewegung, der Farbe sowie der Form der Stimmlippen entwickelt und klinisch evaluiert. W{\"a}hrend die Bewegungsanalyse Aufschluß {\"u}ber funktionelle Stimmst{\"o}rungen gibt, beschreiben Parameter der Farb- und Formanalyse morphologische Ver{\"a}nderungen des Stimmlippengewebes. In diesem Beitrag werden die Methoden und bisherigen Ergebnisse zur Bewegungs- und Farbanalyse vorgestellt. Die Bewegungsanalyse wurde mit einem erweiterten Konturmodell (Snakes) durchgef{\"u}hrt. Aufgrund des modifizierten Konturmodells konnten die Konturen der Stimmlippen automatisch {\"u}ber die gesmate Bildsequenz zuverl{\"a}ssig detektiert werden. Die Vermssung der Konturen liefert neue quantitative Parameter zur Befundung von laryngoskopischen Stimmlippenaufnahmen. Um die Farbeigenschaften der Stimmlippen zu bestimmen, wurde ausgehend vom RGB-Bild die Objektfarbe unabh{\"a}ngig von der Farbe der Lichtquelle durch Verwendung von Clusterverfahren und der Viertelkreisanalyse berechnet. Mit dieser Farbanalyse konnte die Farbe der Lichtquelle ermittelt und das beleuchtungsunabh{\"a}ngige Farbbild berechnet werden. Die Quanitifizierung der R{\"o}tung der Stimmlippen ist z.B. ein entscheidendes Kriterium zur Diagnostik der akuten Laryngitis.}, language = {de} } @inproceedings{PalmKeysersLehmannetal., author = {Palm, Christoph and Keysers, Daniel and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Gabor Filtering of Complex Hue/Saturation Images for Color Texture Classification}, series = {Proceedings of the 5th Joint Conference on Information Science (JCIS) 2, The Association for Intelligent Machinery, Atlantic City, NJ, 2000}, booktitle = {Proceedings of the 5th Joint Conference on Information Science (JCIS) 2, The Association for Intelligent Machinery, Atlantic City, NJ, 2000}, pages = {45 -- 49}, abstract = {Objective: Complex hue/saturation images as a new approach for color texture classification using Gabor filters are introduced and compared with common techniques. Method: The interpretation of hue and saturationas polar coordinates allows direct use of the HSV-colorspace for Fourier transform. This technique is applied for Gabor feature extraction of color textures. In contrast to other color features based on the RGB-colorspace [1] the combination of color bands is done previous to the filtering. Results: The performance of the new HS-featuresis compared with that of RGB based as well as grayscale Gabor features by evaluating the classifi-cation of 30 natural textures. The new HS-featuresshow same results like the best RGB features but allow a more compact representation. On the averagethe color features improve the results of grayscale features. Conclusion: The consideration of the color information enhances the classification of color texture. The choice of colorspace cannot be adjudged finally, but the introduced features suggest the use of the HSV-colorspace with less features than RGB.}, language = {en} } @article{PalmLehmann, author = {Palm, Christoph and Lehmann, Thomas M.}, title = {Classification of Color Textures by Gabor Filtering}, series = {Machine GRAPHICS \& VISION}, volume = {11}, journal = {Machine GRAPHICS \& VISION}, number = {2/3}, pages = {195 -- 219}, language = {en} } @inproceedings{PalmMetzlerMohametal., author = {Palm, Christoph and Metzler, V. and Moham, B. and Dieker, O. and Lehmann, Thomas M. and Spitzer, Klaus}, title = {Co-Occurrence Matrizen zur Texturklassifikation in Vektorbildern}, series = {Bildverarbeitung f{\"u}r die Medizin}, booktitle = {Bildverarbeitung f{\"u}r die Medizin}, editor = {Evers, H. and Glombitza, G. and Lehmann, Thomas M. and Meinzer, H.-P.}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/978-3-642-60125-5_69}, pages = {367 -- 371}, abstract = {Statistische Eigenschaften nat{\"u}rlicher Grauwerttexturen werden mit Co-Occurrence Matrizen, basierend auf der Grauwertstatistik zweiter Ordnung, modelliert. Die Matrix gibt dann die apriori Wahrscheinlichkeiten aller Grauwertpaare an. Da in der medizinischen Bildverarbeitung verst{\"a}rkt Multispektralbilder ausgewertet werden, wird das bekannte Konzept hier auf beliebige Vektorbilder erweitert. Dadurch kann bei der Texturklassifikation die zur Verf{\"u}gung stehende Information vollst{\"a}ndig genutzt werden. Insbesondere zur Detektion von Farbtexturen ist dieser Ansatz geeignet, da Wertepaare unterschiedlicher Spektralebenen ausgewertet werden k{\"o}nnen. Ebenso kann die Methode auch bei der Multiskalendekomposition von Intensit{\"a}tsbildern zur Verbesserung der Texturerkennung beitragen. Die in den Matrizen entstehenden Muster lassen dann {\"u}ber die Extraktion geeigneter Texturdeskriptoren R{\"u}ckschl{\"u}sse auf die Texturen des Bildes zu.}, language = {de} }