@misc{BirkenmaierKrenkelLehle, author = {Birkenmaier, Clemens and Krenkel, Lars and Lehle, Karla}, title = {Linking flow conditions in membrane oxygenators to arrangements of multimeric von-Willebrand-factor as indication for coagulation}, series = {World Congress of Biomechanics 2018, Convention Centre Dublin, 8.-12. Juli 2018}, journal = {World Congress of Biomechanics 2018, Convention Centre Dublin, 8.-12. Juli 2018}, abstract = {Introduction Shear induced multimerisation of von-Willebrand-factor (vWF) is supposed to play an important role in coagulation inside extracorporeal membrane oxygenators. However, there is no proof that links observed vWF structures to computed or measured flow conditions. Methods The structures of multimeric vWF fibers, observed in clinically used membrane oxygenators is examined using immunofluorescence microscopy (IFM) using Carstairs' staining method (positive ethics committee vote). The flow around the membrane fibres inside the oxygenator is investigated in terms of shear rate, wall shear velocity and streamlines by using CFD (RANS, Carreau-Yasuda viscosity, geometry remodelled after high-resolution µCT-scans). By interpreting the histological and numerical results in this common context, indications for shear induced coagulation mechanisms can be identified. Results The fibre structures of multimeric vWF build regular but not exactly symmetric formations around the contact face (CF) between the crosswise stacked oxygenator fibres (OF), see fig.1B, vWF marked red. Annular around the CF arranged, cells are likely to be found, see fig.1B, nuclei marked blue. The computed streamlines around the OF show attached flow around the circular fibres. However, the irregular arrangement of real OF produce considerable cross flow between the interconnected neighbouring channels, in contrast to previous 2D-simulations. Thus, the CF are washed around closely by blood, also from neighbouring channels. The wall shear velocity streamlines form regular, slightly asymmetric shapes around the contact faces. The occurring maximum shear rates are in the range of 1,000 1/s. Discussion The shapes of vWF structures found in clinically used oxygenators match the computational results in terms of wall shear velocity and streamlines well. The accumulation of cells close to the CF can also be explained by fluid mechanics, as there are small shear gradients and slow velocities. However, occurring shear rates between OFs are too low to trigger multimerisation of vWF. That raises the question where in the circuit the actual activation of vWF is started and how, at least partly chained, vWF multimeres are attracted towards the OF surface. A next step will be the investigation of the actual shear rate triggered (or mediated) multimerisation of vWF. Towards this end, microfluidic experiments with shear triggered coagulation will be performed. Also of big interest is the computation of the flow situation in the oxygenator in proximity to chaining threads, which have been ignored in computations so far. However, first a realistic representation of the effective viscosity in computations is needed, which is not available yet.}, language = {en} } @article{SchmitzNeumannNeumannetal., author = {Schmitz, Paul and Neumann, Christoph Cornelius and Neumann, Carsten and Nerlich, Michael and Dendorfer, Sebastian}, title = {Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting}, series = {Journal of Orthopaedic Surgery and Research}, volume = {13}, journal = {Journal of Orthopaedic Surgery and Research}, number = {108}, publisher = {Springer Nature}, doi = {10.1186/s13018-018-0822-1}, pages = {1 -- 8}, abstract = {Background Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Methods Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Results Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. Conclusion A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture.}, subject = {Beckenkammknochen}, language = {en} } @article{BenditzAuerSpoerreretal., author = {Benditz, Achim and Auer, Simon and Sp{\"o}rrer, J.F. and Wolkerstorfer, S. and Grifka, Joachim and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Regarding loads after spinal fusion, every level should be seen separately: a musculoskeletal analysis}, series = {European Spine Journal}, volume = {27}, journal = {European Spine Journal}, number = {8}, publisher = {Springer-Verlag}, doi = {10.1007/s00586-018-5476-5}, pages = {1905 -- 1910}, abstract = {The number of spinal fusion surgeries is steadily increasing and biomechanical consequences are still in debate. The aim of this study is to provide biomechanical insights into the sagittal balance of the spine and to compare spinal load before and after spinal fusion. METHOD: The joint reaction forces of 52 patients were analyzed in proximo-distal and antero-posterior direction from the levels T12-L1 to L5-S1 using musculoskeletal simulations. RESULTS: In 104 simulations, pre-surgical forces were equal to post-surgical. The levels L4-L5 and T12-L1, however, showed increased spinal forces compression forces with higher sagittal displacement. Improved restauration of sagittal balance was accompanied by lower spinal load. AP shear stress, interestingly decreased with sagittal imbalance. CONCLUSION: Imbalanced spines have a risk of increased compression forces at Th12-L1. L4-L5 always has increased spinal loads. These slides can be retrieved under Electronic Supplementary Material.}, subject = {Biomechanische Analyse}, language = {en} } @article{PhilippdeSomerFoltanetal., author = {Philipp, Alois and de Somer, Filip and Foltan, Maik and Bredthauer, Andre and Krenkel, Lars and Zeman, Florian and Lehle, Karla}, title = {Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice}, series = {PLOS ONE}, volume = {13}, journal = {PLOS ONE}, number = {6}, publisher = {PLOS}, doi = {10.1371/journal.pone.0198392}, pages = {1 -- 10}, abstract = {Over the past decade, veno-venous extracorporeal membrane oxygenation (vvECMO) has been increasingly utilized in respiratory failure in patients. This study presents our institution´s experience focusing on the life span of ECMO systems reflecting the performance of a particular system. A retrospective review of our ECMO database identified 461 adult patients undergoing vvECMO (2010-2017). Patients that required more than one system and survived the first exchange >24 hours (n = 139) were included. Life span until the first exchange and exchange criteria were analyzed for all systems (PLS, Cardiohelp HLS-set, both Maquet Cardiopulmonary, Rastatt, Germany; Deltastream/Hilite7000LT, iLA-activve, Xenios/NovaLung, Heilbronn, Germany; ECC.O5, LivaNova, Mirandola, Italy). At our ECMO center, the frequency of a system exchange was 30\%. The median (IQR) life span was 9 (6-12) days. There was no difference regarding the different systems (p = 0.145 and p = 0.108, respectively). However, the Deltastream systems were exchanged more frequently due to elective technical complications (e. g. worsened gas transfer, development of coagulation disorder, increased bleedings complications) compared to the other exchanged systems (p = 0.013). In summary, the used ECMO systems are safe and effective for acute respiratory failure. There is no evidence for the usage of a specific system. Only the increased predictability of an imminent exchange preferred the usage of a Deltastream system. However, the decision to use a particular system should not depend solely on the possible criteria for an exchange.}, language = {en} } @article{Raptis, author = {Raptis, Georgios}, title = {Technischer Datenschutz in der telemedizinischen Versorgung}, series = {Der Krankenhaus-JUSTITIAR}, volume = {7}, journal = {Der Krankenhaus-JUSTITIAR}, number = {4}, pages = {105 -- 107}, abstract = {Die fortschreitende Digitalisierung des Gesundheitswesens ebnet auch den Weg einer st{\"a}rkeren Verbreitung der telemedizinischen Versorgung in Deutschland. Die Politik erleichtert diesen Weg, z.B. mit dem eHealth-Gesetz oder mit der Lockerung des "Fernbehandlungsverbots" durch den Deutschen {\"A}rztetag. Dabei wird schon aus der Definition (siehe z.B. die unten stehende Definition der AG Telemedizin) klar, dass Telemedizin keine neue medizinische Disziplin begr{\"u}ndet. Bei Telemedizin handelt es sich nur um ein technisches Werkzeug in Kombination mit geeigneten klinischen Prozessen, damit bestehende medizinische Expertise unter Einsatz von Informations- und Kommunikationstechnologien r{\"a}umliche Entfernungen oder einen zeitlichen Versatz {\"u}berbr{\"u}cken kann. Patientinnen und Patienten k{\"o}nnen also behandelt werden, auch wenn sie vom Arzt r{\"a}umlich entfernt sind.}, subject = {Telemedizin}, language = {de} } @misc{BirkenmaierKrenkel, author = {Birkenmaier, Clemens and Krenkel, Lars}, title = {Towards a realistic model of blood viscosity and coagulation in membrane oxygenators}, series = {6th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems) - ECCM 6; 7th European Conference on Computational Fluid Dynamics - ECFD 7 : Glasgow, Scotland, UK, June 11-15, 2018}, journal = {6th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems) - ECCM 6; 7th European Conference on Computational Fluid Dynamics - ECFD 7 : Glasgow, Scotland, UK, June 11-15, 2018}, abstract = {Modelling blood flow an shear induced coagulation in membraene oxygenators (MO) is challenging. The relevant geometry of oxygenator fibers (OF) and chaining threads is complex and spans several length scales. In relevant scales and regimes blood shows several significant non-Newtonian effects. Existing models are only capable of accounting for some, but not all relevant effects. Additionally, coagulation processes are influencing fluid properties and geometry significantly. Due to the enormous size of the discretised geometries highly detailed viscosity and coagulation properties of blodd flow in MOs. First step is to find a gemoetry dependent viscosity representation on basis of parametric micro channel experiments with anti-coagulated blood. Next step is a statistic coagulation model, based on micro channel experiments with human (re-calcified citrated) whole blood an evaluation of clinically used osygenators. Since shear rate dependent (i.e. viscosity dependet) coagulation in return influences the viscosity, a combined model with suitable implementation in a RANS framework is necessary. Towards this end, micro channel experiments with new and used single OFs triggering coagulation are performed. Structures of multimeric von Willebrand fibers (vWF), as indicator for shear induced coagulation, are compared to computed and measured flow conditions, using immunofluorescence microscopy, RANS-computations and µPIV, respectively. Preliminary examinations in clinically used MOs show good agreement between occurring structures of vWF, cell depositions and computed flow patterns (geometry form µCT-Scans). However, computed shear rates might be to low to actually trigger activation of vWF. The complex geometry of MOs results in huge meshes, which makes RANS with statistical modelling of viscosity and coagulation a reasonable approach. Towards this end, experimental data on micro channel level with evaluation on real application level is crucial. Especially regarding clotting processes, micro fluidic experiments are powerful research tool.}, language = {en} } @inproceedings{BirkenmaierSteigerPhilippetal., author = {Birkenmaier, Clemens and Steiger, Tamara and Philipp, Alois and Lehle, Karla and Krenkel, Lars}, title = {Flow-induced accumulations of von Willebrand factor inside oxygenators during extracorporeal life support therapy}, series = {Proceedings of 12th International Conference BIOMDLORE 2018, June 28-30, 2018, Białystok, Poland}, booktitle = {Proceedings of 12th International Conference BIOMDLORE 2018, June 28-30, 2018, Białystok, Poland}, publisher = {IEEE}, address = {Piscataway, NJ}, isbn = {978-1-5386-2396-1}, doi = {10.1109/BIOMDLORE.2018.8467205}, pages = {3}, abstract = {BACKGROUND: Shear-induced conformational changes of von Willebrand factor (vWF) may be responsible for coagulation disorder and clot formation inside membrane oxygenators (MOs) during extracorporeal membrane oxygenation (ECMO) therapy. OBJECTIVE: The aim was to identify vWF structures inside clinically used MOs and employ computational fluid dynamics to verify the corresponding flow conditions. METHODS: Samples from gas exchange membranes (GEM) from MOs were analysed for accumulations of vWF and P-selectin-positive platelets using immunofluorescence techniques. Streamlines and shear rates of the flow around GEMs were computed using a laminar steady Reynolds-Averaged-Navier-Stokes approach. RESULTS: Most samples were colonized with equally distributed leukocytes, integrated in thin cobweb-like vWF-structures. Only 25 \% of the samples showed extended accumulations of vWF. Computed streamlines showed considerable cross flow between interconnected neighbouring channels. Stagnation points were non-symmetric and contact faces were washed around closely. The occurring maximum shear rates ranged from 2,500 to 3,000 1/s. CONCLUSIONS: If pronounced vWF structures are present, shape and extent match the flow computations well. Computed shear rates bear a critical degree of uncertainty due to the improper viscosity model. If flow conditions inside the MO were sufficient to affect vWF, a more consistent distribution of vWF across the samples should be present.}, language = {en} } @misc{WiesentHupkeBalketal., author = {Wiesent, Lisa and Hupke, Constantin and Balk, Christian and Schultheiss, Ulrich and Schratzenstaller, Thomas}, title = {Optimization of the cardiovascular stent design towards improved expansion behaviour and radial stiffness properties}, series = {Biomedizinische Technik}, volume = {63}, journal = {Biomedizinische Technik}, number = {s1}, doi = {10.1515/bmt-2018-6031}, abstract = {- Development of a FEA Tool for a realistic stent simulation - investigation on minor modification on the stent design on the expansion behaviour - analysis of three stent designs: classical stent design with pronounced dogbone effect, two modified stent design (non-dogbone-design)}, subject = {Kardiovaskul{\"a}res System}, language = {en} } @misc{GeithSwidergalSchratzenstalleretal., author = {Geith, Markus A. and Swidergal, Krzysztof and Schratzenstaller, Thomas and Holzapfel, Gerhard A. and Wagner, Marcus}, title = {Numerical analysis of stent delivery systems during pre- and intraoperative processes}, series = {15. Deutsches LS-DYNA Forum, 15.-17.10.2018, Bamberg}, journal = {15. Deutsches LS-DYNA Forum, 15.-17.10.2018, Bamberg}, language = {en} } @inproceedings{GrossVerkerkeDendorfer, author = {Gross, Simon and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Combined Experimental and Numerical Approach to Investigate Changes in Muscle Recruitment Pattern of the Back Muscles during Exhausting Exercise}, series = {World Congress Biomechanics Dublin, 2018}, booktitle = {World Congress Biomechanics Dublin, 2018}, abstract = {In recent years, musculoskeletal computation has become a widely used tool to investigate joint and muscle forces within the human body. However, the issue of muscle fatigue is not considered adequately in most models and is a challenging task. One aspect that needs to be examined is the interaction of muscles during an exhausting task. Therefore, an experimental study was designed to analyze the changes of back muscle recruitment pattern during such exercises. In this study 38 subjects (27 male, 11 female, height = 177±8.5 cm, weight = 74.0±13.6 kg) participated. Each subject had to perform three static and three dynamic exhausting exercises where the back muscles were loaded with subject specific forces using a dynamometer adapter especially designed for the trunk muscles. To collect the muscle activity, twelve surface electromyography sensors were applied on the back, and four on the abdominal muscles. Muscle activity and fatigue were analyzed by calculating the maximum voluntary contraction normalized signal and the median frequency. At first the fatigue of m. erector spinae and m. multifidi was analyzed, since these muscles carry the main load during the exercises. Subsequently the activity of the m. trapezius, m. rectus abdominis and m. obliquus externus were investigated to determine recruitment patterns. To gain more detailed information of these patterns a numerical model was built using the AnyBody Modeling System™. Analyzing the measurements, we can observe an increasing muscle activity during isokinetic exercises while the force is constant. Since the activity in the simulation is defined as the current force output divided by the strength of the muscle, the strength parameter was scaled down based on the measured data, assuming a linear force - activity correlation, and using a numerical algorithm considering the influence of cross talk. The results show, that changes in recruitment pattern can be divided into three major subgroups. Prior to total exhaustion, some of the subjects show additional activation of muscles in the trapezius region, while other subjects show an additional activation of abdominal muscles, increasing the intra-abdominal pressure which supports the spine. In the third group an activation in both regions can be observed. The numerical simulations show an increasing activity of abdominal muscles as well as muscles in the upper back. Especially the m. latissimus dorsi shows a significantly higher activity. The results lead to the conclusion that prior to total exhaustion, additional muscles are recruited to support the main muscles. It was shown that abdominal muscles are activated to support back muscles by pressurizing the trunk cavity to delay total exhaustion as long as possible. In conclusion, the results show that changes in muscle recruitment pattern need to be considered when introducing muscle fatigue to musculoskeletal models.}, language = {en} } @inproceedings{JungtaeublAurbachMelzneretal., author = {Jungt{\"a}ubl, Dominik and Aurbach, Maximilian and Melzner, Maximilian and Spicka, Jan and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {EMG-Based Validation of Musculoskeletal Models Considering Crosstalk}, series = {International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland}, booktitle = {International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland}, doi = {10.1109/BIOMDLORE.2018.8467211}, abstract = {BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.}, language = {en} } @inproceedings{SuessKubowitschVerkerkeetal., author = {S{\"u}ß, Franz and Kubowitsch, Simone and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Investigation of cognitive stress induced changes in spinal disc forces due to altered kinematics and muscle activity}, series = {World Congress Biomechanics, Dublin, 2018}, booktitle = {World Congress Biomechanics, Dublin, 2018}, language = {en} } @inproceedings{KubowitschSuessJansenetal., author = {Kubowitsch, Simone and S{\"u}ß, Franz and Jansen, Petra and Dendorfer, Sebastian}, title = {Comparison of dynamic muscular imbalances in back pain patients and healthy controls}, series = {World Congress Biomechanics Dublin, 2018}, booktitle = {World Congress Biomechanics Dublin, 2018}, language = {en} } @inproceedings{SeefriedAurbachWyssetal., author = {Seefried, C. and Aurbach, Maximilian and Wyss, C. and Dendorfer, Sebastian}, title = {Achilles tendon lengthening alters stresses in the growth plate}, series = {International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland}, booktitle = {International Conference BIOMDLORE, June 28 - 30 2018, Białystok, Poland}, language = {en} } @inproceedings{KubowitschDendorfer, author = {Kubowitsch, Simone and Dendorfer, Sebastian}, title = {Psychologie und Biomechanik - Integrierte Betrachtung von Muskelrekrutierung}, series = {Jahrestagung der Deutschen Gesellschaft f{\"u}r Biofeedback e. V., Regensburg, 2018}, booktitle = {Jahrestagung der Deutschen Gesellschaft f{\"u}r Biofeedback e. V., Regensburg, 2018}, language = {de} } @incollection{SinghCapanni, author = {Singh, Max Diamond and Capanni, Felix}, title = {Medizintechnik-Spin-offs aus der Hochschule - Ein Prozessbeispiel}, series = {Entrepreneurship im Gesundheitswesen II}, booktitle = {Entrepreneurship im Gesundheitswesen II}, editor = {Pfannstiel Mario A., and Da-Cruz, Patrick and Rasche, Christoph}, publisher = {Springer Gabler}, address = {Wiesbaden}, isbn = {978-3-658-14781-5}, abstract = {Die Aufmerksamkeit f{\"u}r Unternehmensgr{\"u}ndungen hat in den letzten Jahren extrem zugenommen. Grunds{\"a}tzlich muss ein Start-up in einem kompetitiven Umfeld erfolgreich sein, um bestehen zu k{\"o}nnen. Der Weg dorthin wird maßgeblich beeinflusst durch Planung und finanzielle Ressourcen, die die Gr{\"u}nder bereitstellen m{\"u}ssen. In der Medizinprodukteindustrie kommen zus{\"a}tzlich große H{\"u}rden hinzu, die u. a. einen kurzen Produktlebenszyklus, lange Projektlaufzeiten, aufwendige klinische Studien und aktuell neue gesetzliche Verordnungen betreffen. Dieser Beitrag konzentriert sich zun{\"a}chst auf m{\"o}gliche F{\"o}rdermittel und Beratung von Start-up-Projekten aus dem Hochschulbereich. Aus einer Analyse derzeit existierender Gr{\"u}nderwettbewerbe im Hinblick auf das Gesundheitswesen werden dem Leser entsprechende Adressen zum Einwerben von F{\"o}rdermitteln geliefert. Dar{\"u}ber hinaus wird ein Pilot-Prozess vorgestellt, wie eine Ausgr{\"u}ndungsberatung an der Hochschule Ulm im Studiengang Medizintechnik derzeit verl{\"a}uft. Dies kann m{\"o}glicherweise ein Ankn{\"u}pfungspunkt f{\"u}r eine zuk{\"u}nftige Institutionalisierung von Spin-off-Vorhaben aus dem Hochschulbereich sein.}, language = {de} } @article{SellmerStanglBeyeretal., author = {Sellmer, Andreas and Stangl, Hubert and Beyer, Mandy and Gr{\"u}nstein, Elisabeth and Leonhardt, Michel and Pongratz, Herwig and Eichhorn, Emerich and Elz, Sigurd and Striegl, Birgit and Jenei-Lanzl, Zsuzsa and Dove, Stefan and Straub, Rainer H. and Kr{\"a}mer, Oliver H. and Mahboobi, Siavosh}, title = {Marbostat-100 Defines a New Class of Potent and Selective Antiinflammatory and Antirheumatic Histone Deacetylase 6 Inhibitors}, series = {Journal of medicinal chemistry}, volume = {61}, journal = {Journal of medicinal chemistry}, number = {8}, publisher = {ACS Publications}, doi = {10.1021/acs.jmedchem.7b01593}, pages = {3454 -- 3477}, abstract = {Epigenetic modifiers of the histone deacetylase (HDAC) family contribute to autoimmunity, cancer, HIV infection, inflammation, and neurodegeneration. Hence, histone deacetylase inhibitors (HDACi), which alter protein acetylation, gene expression patterns, and cell fate decisions, represent promising new drugs for the therapy of these diseases. Whereas pan-HDACi inhibit all 11 Zn2+-dependent histone deacetylases (HDACs) and cause a broad spectrum of side effects, specific inhibitors of histone deacetylase 6 (HDAC6i) are supposed to have less side effects. We present the synthesis and biological evaluation of Marbostats, novel HDAC6i that contain the hydroxamic acid moiety linked to tetrahydro-β-carboline derivatives. Our lead compound Marbostat-100 is a more potent and more selective HDAC6i than previously established well-characterized compounds in vitro as well as in cells. Moreover, Marbostat-100 is well tolerated by mice and effective against collagen type II induced arthritis. Thus, Marbostat-100 represents a most selective known HDAC6i and the possibility for clinical evaluation of a HDAC isoform-specific drug.}, language = {en} } @article{SchroederPolzerSlažanskyetal., author = {Schroeder, Florian and Polzer, Stanislav and Slažansk{\´y}, Martin and Man, Vojtěch and Sk{\´a}cel, Pavel}, title = {Predictive capabilities of various constitutive models for arterial tissue}, series = {Journal of the Mechanical Behavior of Biomedical Materials}, volume = {78}, journal = {Journal of the Mechanical Behavior of Biomedical Materials}, number = {February}, publisher = {Elsevier}, doi = {10.1016/j.jmbbm.2017.11.035}, pages = {369 -- 380}, abstract = {Introduction Aim of this study is to validate some constitutive models by assessing their capabilities in describing and predicting uniaxial and biaxial behavior of porcine aortic tissue. Methods 14 samples from porcine aortas were used to perform 2 uniaxial and 5 biaxial tensile tests. Transversal strains were furthermore stored for uniaxial data. The experimental data were fitted by four constitutive models: Holzapfel-Gasser-Ogden model (HGO), model based on generalized structure tensor (GST), Four-Fiber-Family model (FFF) and Microfiber model. Fitting was performed to uniaxial and biaxial data sets separately and descriptive capabilities of the models were compared. Their predictive capabilities were assessed in two ways. Firstly each model was fitted to biaxial data and its accuracy (in term of R2 and NRMSE) in prediction of both uniaxial responses was evaluated. Then this procedure was performed conversely: each model was fitted to both uniaxial tests and its accuracy in prediction of 5 biaxial responses was observed. Results Descriptive capabilities of all models were excellent. In predicting uniaxial response from biaxial data, microfiber model was the most accurate while the other models showed also reasonable accuracy. Microfiber and FFF models were capable to reasonably predict biaxial responses from uniaxial data while HGO and GST models failed completely in this task. Conclusions HGO and GST models are not capable to predict biaxial arterial wall behavior while FFF model is the most robust of the investigated constitutive models. Knowledge of transversal strains in uniaxial tests improves robustness of constitutive models.}, language = {en} } @misc{Singh, author = {Singh, Max Diamond}, title = {Zus{\"a}tzliche Anforderungen an Produktdaten und technische Dokumentation durch die MDR}, series = {Medizintechnik Kongress 2018: Effizienz in der Medizinprodukteentwicklung vor dem Hintergrund von MDR und IVDR ; Frankfurt am Main, 08.11.2018, [Veranstalter: Velten Consulting \& ILC Consulting]}, journal = {Medizintechnik Kongress 2018: Effizienz in der Medizinprodukteentwicklung vor dem Hintergrund von MDR und IVDR ; Frankfurt am Main, 08.11.2018, [Veranstalter: Velten Consulting \& ILC Consulting]}, language = {de} } @misc{Singh, author = {Singh, Max Diamond}, title = {Notified Body Viewpoint : Preparing for MDR/IVDR}, series = {MDR/IVDR - Status Report from Stakeholders. Where are we now in November 2018? - Bern, 22.11.2018 - [Veranstalter: RAPS : Regulatory Affairs Professionals Society]}, journal = {MDR/IVDR - Status Report from Stakeholders. Where are we now in November 2018? - Bern, 22.11.2018 - [Veranstalter: RAPS : Regulatory Affairs Professionals Society]}, language = {en} }