@inproceedings{WeihererZornWittenbergetal., author = {Weiherer, Maximilian and Zorn, Martin and Wittenberg, Thomas and Palm, Christoph}, title = {Retrospective Color Shading Correction for Endoscopic Images}, series = {Bildverarbeitung f{\"u}r die Medizin 2020. Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 15. bis 17. M{\"a}rz 2020 in Berlin}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2020. Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 15. bis 17. M{\"a}rz 2020 in Berlin}, editor = {Tolxdorff, Thomas and Deserno, Thomas M. and Handels, Heinz and Maier, Andreas and Maier-Hein, Klaus H. and Palm, Christoph}, publisher = {Springer Vieweg}, address = {Wiesbaden}, isbn = {978-3-658-29266-9}, doi = {10.1007/978-3-658-29267-6}, pages = {14 -- 19}, abstract = {In this paper, we address the problem of retrospective color shading correction. An extension of the established gray-level shading correction algorithm based on signal envelope (SE) estimation to color images is developed using principal color components. Compared to the probably most general shading correction algorithm based on entropy minimization, SE estimation does not need any computationally expensive optimization and thus can be implemented more effciently. We tested our new shading correction scheme on artificial as well as real endoscopic images and observed promising results. Additionally, an indepth analysis of the stop criterion used in the SE estimation algorithm is provided leading to the conclusion that a fixed, user-defined threshold is generally not feasible. Thus, we present new ideas how to develop a non-parametric version of the SE estimation algorithm using entropy.}, subject = {Endoskopie}, language = {en} } @unpublished{WeihererEigenbergerBrebantetal., author = {Weiherer, Maximilian and Eigenberger, Andreas and Br{\´e}bant, Vanessa and Prantl, Lukas and Palm, Christoph}, title = {Learning the shape of female breasts: an open-access 3D statistical shape model of the female breast built from 110 breast scans}, pages = {15}, abstract = {We present the Regensburg Breast Shape Model (RBSM) - a 3D statistical shape model of the female breast built from 110 breast scans, and the first ever publicly available. Together with the model, a fully automated, pairwise surface registration pipeline used to establish correspondence among 3D breast scans is introduced. Our method is computationally efficient and requires only four landmarks to guide the registration process. In order to weaken the strong coupling between breast and thorax, we propose to minimize the variance outside the breast region as much as possible. To achieve this goal, a novel concept called breast probability masks (BPMs) is introduced. A BPM assigns probabilities to each point of a 3D breast scan, telling how likely it is that a particular point belongs to the breast area. During registration, we use BPMs to align the template to the target as accurately as possible inside the breast region and only roughly outside. This simple yet effective strategy significantly reduces the unwanted variance outside the breast region, leading to better statistical shape models in which breast shapes are quite well decoupled from the thorax. The RBSM is thus able to produce a variety of different breast shapes as independently as possible from the shape of the thorax. Our systematic experimental evaluation reveals a generalization ability of 0.17 mm and a specificity of 2.8 mm for the RBSM. Ultimately, our model is seen as a first step towards combining physically motivated deformable models of the breast and statistical approaches in order to enable more realistic surgical outcome simulation.}, language = {en} } @article{HartmannWeihererSchiltzetal., author = {Hartmann, Robin and Weiherer, Maximilian and Schiltz, Daniel and Seitz, Stephan and Lotter, Luisa and Anker, Alexandra and Palm, Christoph and Prantl, Lukas and Br{\´e}bant, Vanessa}, title = {A Novel Method of Outcome Assessment in Breast Reconstruction Surgery: Comparison of Autologous and Alloplastic Techniques Using Three-Dimensional Surface Imaging}, series = {Aesthetic Plastic Surgery}, volume = {44}, journal = {Aesthetic Plastic Surgery}, publisher = {Springer}, address = {Heidelberg}, doi = {10.1007/s00266-020-01749-4}, pages = {1980 -- 1987}, abstract = {Background Breast reconstruction is an important coping tool for patients undergoing a mastectomy. There are numerous surgical techniques in breast reconstruction surgery (BRS). Regardless of the technique used, creating a symmetric outcome is crucial for patients and plastic surgeons. Three-dimensional surface imaging enables surgeons and patients to assess the outcome's symmetry in BRS. To discriminate between autologous and alloplastic techniques, we analyzed both techniques using objective optical computerized symmetry analysis. Software was developed that enables clinicians to assess optical breast symmetry using three-dimensional surface imaging. Methods Twenty-seven patients who had undergone autologous (n = 12) or alloplastic (n = 15) BRS received three-dimensional surface imaging. Anthropomorphic data were collected digitally using semiautomatic measurements and automatic measurements. Automatic measurements were taken using the newly developed software. To quantify symmetry, a Symmetry Index is proposed. Results Statistical analysis revealed that there is no dif- ference in the outcome symmetry between the two groups (t test for independent samples; p = 0.48, two-tailed). Conclusion This study's findings provide a foundation for qualitative symmetry assessment in BRS using automatized digital anthropometry. In the present trial, no difference in the outcomes' optical symmetry was detected between autologous and alloplastic approaches.}, subject = {Mammoplastik}, language = {en} } @article{HartmannWeihererSchiltzetal., author = {Hartmann, Robin and Weiherer, Maximilian and Schiltz, Daniel and Baringer, Magnus and Noisser, Vivien and H{\"o}sl, Vanessa and Eigenberger, Andreas and Seitz, Stefan and Palm, Christoph and Prantl, Lukas and Br{\´e}bant, Vanessa}, title = {New aspects in digital breast assessment: further refinement of a method for automated digital anthropometry}, series = {Archives of Gynecology and Obstetrics}, volume = {303}, journal = {Archives of Gynecology and Obstetrics}, publisher = {Springer Nature}, address = {Heidelberg}, issn = {1432-0711}, doi = {10.1007/s00404-020-05862-2}, pages = {721 -- 728}, abstract = {Purpose: In this trial, we used a previously developed prototype software to assess aesthetic results after reconstructive surgery for congenital breast asymmetry using automated anthropometry. To prove the consensus between the manual and automatic digital measurements, we evaluated the software by comparing the manual and automatic measurements of 46 breasts. Methods: Twenty-three patients who underwent reconstructive surgery for congenital breast asymmetry at our institution were examined and underwent 3D surface imaging. Per patient, 14 manual and 14 computer-based anthropometric measurements were obtained according to a standardized protocol. Manual and automatic measurements, as well as the previously proposed Symmetry Index (SI), were compared. Results: The Wilcoxon signed-rank test revealed no significant differences in six of the seven measurements between the automatic and manual assessments. The SI showed robust agreement between the automatic and manual methods. Conclusion: The present trial validates our method for digital anthropometry. Despite the discrepancy in one measurement, all remaining measurements, including the SI, showed high agreement between the manual and automatic methods. The proposed data bring us one step closer to the long-term goal of establishing robust instruments to evaluate the results of breast surgery.}, language = {en} } @article{HartmannWeihererNieberleetal., author = {Hartmann, Robin and Weiherer, Maximilian and Nieberle, Felix and Palm, Christoph and Br{\´e}bant, Vanessa and Prantl, Lukas and Lamby, Philipp and Reichert, Torsten E. and Taxis, J{\"u}rgen and Ettl, Tobias}, title = {Evaluating smartphone-based 3D imaging techniques for clinical application in oral and maxillofacial surgery: A comparative study with the vectra M5}, series = {Oral and Maxillofacial Surgery}, volume = {29}, journal = {Oral and Maxillofacial Surgery}, publisher = {Springer Nature}, doi = {10.1007/s10006-024-01322-2}, pages = {17}, abstract = {PURPOSE This study aimed to clarify the applicability of smartphone-based three-dimensional (3D) surface imaging for clinical use in oral and maxillofacial surgery, comparing two smartphone-based approaches to the gold standard. METHODS Facial surface models (SMs) were generated for 30 volunteers (15 men, 15 women) using the Vectra M5 (Canfield Scientific, USA), the TrueDepth camera of the iPhone 14 Pro (Apple Inc., USA), and the iPhone 14 Pro with photogrammetry. Smartphone-based SMs were superimposed onto Vectra-based SMs. Linear measurements and volumetric evaluations were performed to evaluate surface-to-surface deviation. To assess inter-observer reliability, all measurements were performed independently by a second observer. Statistical analyses included Bland-Altman analyses, the Wilcoxon signed-rank test for paired samples, and Intraclass correlation coefficients. RESULTS Photogrammetry-based SMs exhibited an overall landmark-to-landmark deviation of M = 0.8 mm (SD =  ± 0.58 mm, n = 450), while TrueDepth-based SMs displayed a deviation of M = 1.1 mm (SD =  ± 0.72 mm, n = 450). The mean volumetric difference for photogrammetry-based SMs was M = 1.8 cc (SD =  ± 2.12 cc, n = 90), and M = 3.1 cc (SD =  ± 2.64 cc, n = 90) for TrueDepth-based SMs. When comparing the two approaches, most landmark-to-landmark measurements demonstrated 95\% Bland-Altman limits of agreement (LoA) of ≤ 2 mm. Volumetric measurements revealed LoA > 2 cc. Photogrammetry-based measurements demonstrated higher inter-observer reliability for overall landmark-to-landmark deviation. CONCLUSION Both approaches for smartphone-based 3D surface imaging exhibit potential in capturing the face. Photogrammetry-based SMs demonstrated superior alignment and volumetric accuracy with Vectra-based SMs than TrueDepth-based SMs.}, language = {en} } @article{RueweEigenbergerKleinetal., author = {Ruewe, Marc and Eigenberger, Andreas and Klein, Silvan and von Riedheim, Antonia and Gugg, Christine and Prantl, Lukas and Palm, Christoph and Weiherer, Maximilian and Zeman, Florian and Anker, Alexandra}, title = {Precise Monitoring of Returning Sensation in Digital Nerve Lesions by 3-D Imaging: A Proof-of-Concept Study}, series = {Plastic and Reconstructive Surgery}, volume = {152}, journal = {Plastic and Reconstructive Surgery}, number = {4}, publisher = {Lippincott Williams \& Wilkins}, address = {Philadelphia, Pa.}, organization = {American Society of Plastic Surgeons}, issn = {1529-4242}, doi = {10.1097/PRS.0000000000010456}, pages = {670e -- 674e}, abstract = {Digital nerve lesions result in a loss of tactile sensation reflected by an anesthetic area (AA) at the radial or ulnar aspect of the respective digit. Yet, available tools to monitor the recovery of tactile sense have been criticized for their lack of validity. However, the precise quantification of AA dynamics by three-dimensional (3-D) imaging could serve as an accurate surrogate to monitor recovery following digital nerve repair. For validation, AAs were marked on digits of healthy volunteers to simulate the AA of an impaired cutaneous innervation. Three dimensional models were composed from raw images that had been acquired with a 3-D camera (Vectra H2) to precisely quantify relative AA for each digit (3-D models, n= 80). Operator properties varied regarding individual experience in 3-D imaging and image processing. Additionally, the concept was applied in a clinical case study. Images taken by experienced photographers were rated better quality (p< 0.001) and needed less processing time (p= 0.020). Quantification of the relative AA was neither altered significantly by experience levels of the photographer (p= 0.425) nor the image assembler (p= 0.749). The proposed concept allows precise and reliable surface quantification of digits and can be performed consistently without relevant distortion by lack of examiner experience. Routine 3-D imaging of the AA has the great potential to provide visual evidence of various returning states of sensation and to convert sensory nerve recovery into a metric variable with high responsiveness to temporal progress.}, language = {en} } @unpublished{WeiherervonRiedheimBrebantetal., author = {Weiherer, Maximilian and von Riedheim, Antonia and Br{\´e}bant, Vanessa and Egger, Bernhard and Palm, Christoph}, title = {iRBSM: A Deep Implicit 3D Breast Shape Model}, doi = {10.48550/arXiv.2412.13244}, pages = {6}, abstract = {We present the first deep implicit 3D shape model of the female breast, building upon and improving the recently proposed Regensburg Breast Shape Model (RBSM). Compared to its PCA-based predecessor, our model employs implicit neural representations; hence, it can be trained on raw 3D breast scans and eliminates the need for computationally demanding non-rigid registration -- a task that is particularly difficult for feature-less breast shapes. The resulting model, dubbed iRBSM, captures detailed surface geometry including fine structures such as nipples and belly buttons, is highly expressive, and outperforms the RBSM on different surface reconstruction tasks. Finally, leveraging the iRBSM, we present a prototype application to 3D reconstruct breast shapes from just a single image. Model and code publicly available at this https URL.}, language = {en} } @misc{MaierWeihererHuberetal., author = {Maier, Johannes and Weiherer, Maximilian and Huber, Michaela and Palm, Christoph}, title = {Abstract: Imitating Human Soft Tissue with Dual-Material 3D Printing}, series = {Bildverarbeitung f{\"u}r die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. M{\"a}rz 2019 in L{\"u}beck}, journal = {Bildverarbeitung f{\"u}r die Medizin 2019, Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 17. bis 19. M{\"a}rz 2019 in L{\"u}beck}, editor = {Handels, Heinz and Deserno, Thomas M. and Maier, Andreas and Maier-Hein, Klaus H. and Palm, Christoph and Tolxdorff, Thomas}, publisher = {Springer Vieweg}, address = {Wiesbaden}, isbn = {978-3-658-25325-7}, doi = {10.1007/978-3-658-25326-4_48}, pages = {218}, abstract = {Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand.}, subject = {Handchirurgie}, language = {en} } @article{WeihererEigenbergerEggeretal., author = {Weiherer, Maximilian and Eigenberger, Andreas and Egger, Bernhard and Br{\´e}bant, Vanessa and Prantl, Lukas and Palm, Christoph}, title = {Learning the shape of female breasts: an open-access 3D statistical shape model of the female breast built from 110 breast scans}, series = {The Visual Computer}, volume = {39}, journal = {The Visual Computer}, number = {4}, publisher = {Springer Nature}, doi = {10.1007/s00371-022-02431-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-30506}, pages = {1597 -- 1616}, abstract = {We present the Regensburg Breast Shape Model (RBSM)—a 3D statistical shape model of the female breast built from 110 breast scans acquired in a standing position, and the first publicly available. Together with the model, a fully automated, pairwise surface registration pipeline used to establish dense correspondence among 3D breast scans is introduced. Our method is computationally efficient and requires only four landmarks to guide the registration process. A major challenge when modeling female breasts from surface-only 3D breast scans is the non-separability of breast and thorax. In order to weaken the strong coupling between breast and surrounding areas, we propose to minimize the variance outside the breast region as much as possible. To achieve this goal, a novel concept called breast probability masks (BPMs) is introduced. A BPM assigns probabilities to each point of a 3D breast scan, telling how likely it is that a particular point belongs to the breast area. During registration, we use BPMs to align the template to the target as accurately as possible inside the breast region and only roughly outside. This simple yet effective strategy significantly reduces the unwanted variance outside the breast region, leading to better statistical shape models in which breast shapes are quite well decoupled from the thorax. The RBSM is thus able to produce a variety of different breast shapes as independently as possible from the shape of the thorax. Our systematic experimental evaluation reveals a generalization ability of 0.17 mm and a specificity of 2.8 mm. To underline the expressiveness of the proposed model, we finally demonstrate in two showcase applications how the RBSM can be used for surgical outcome simulation and the prediction of a missing breast from the remaining one. Our model is available at https://www.rbsm.re-mic.de/.}, language = {en} } @article{BrebantWeihererNoisseretal., author = {Br{\´e}bant, Vanessa and Weiherer, Maximilian and Noisser, Vivien and Seitz, Stephan and Prantl, Lukas and Eigenberger, Andreas}, title = {Implants Versus Lipograft: Analysis of Long-Term Results Following Congenital Breast Asymmetry Correction}, series = {Aesthetic Plastic Surgery}, volume = {46}, journal = {Aesthetic Plastic Surgery}, publisher = {Springer Nature}, doi = {10.1007/s00266-022-02843-5}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-32404}, pages = {2228 -- 2236}, abstract = {Aims Congenital breast asymmetry represents a particular challenge to the classic techniques of plastic surgery given the young age of patients at presentation. This study reviews and compares the long-term results of traditional breast augmentation using silicone implants and the more innovative technique of lipografting. Methods To achieve this, we not only captured subjective parameters such as satisfaction with outcome and symmetry, but also objective parameters including breast vol-ume and anthropometric measurements. The objective examination was performed manually and by using the Vectra H2 photogrammetry scanning system. Results Differences between patients undergoing either implant augmentation or lipograft were revealed not to be significant with respect to patient satisfaction with surgical outcome (p= 0.55) and symmetry (p= 0.69). Furthermore, a breast symmetry of 93 \% was reported in both groups. Likewise, no statistically significant volume difference between the left and right breasts was observed in both groups (p\0.41). However, lipograft patients needed on average 2.9 procedures to achieve the desired result, compared with 1.3 for implant augmentation. In contrast, patients treated with implant augmentation may require anumber of implant changes during their lifetime. Conclusion Both methods may be considered for patients presenting with congenital breast asymmetry.}, language = {en} } @article{MaierWeihererHuberetal., author = {Maier, Johannes and Weiherer, Maximilian and Huber, Michaela and Palm, Christoph}, title = {Imitating human soft tissue on basis of a dual-material 3D print using a support-filled metamaterial to provide bimanual haptic for a hand surgery training system}, series = {Quantitative Imaging in Medicine and Surgery}, volume = {9}, journal = {Quantitative Imaging in Medicine and Surgery}, number = {1}, publisher = {AME Publishing Company}, doi = {10.21037/qims.2018.09.17}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-979}, pages = {30 -- 42}, abstract = {Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand. Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed. Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure. Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue.}, subject = {Handchirurgie}, language = {en} } @article{MaierWeihererHuberetal., author = {Maier, Johannes and Weiherer, Maximilian and Huber, Michaela and Palm, Christoph}, title = {Optically tracked and 3D printed haptic phantom hand for surgical training system}, series = {Quantitative Imaging in Medicine and Surgery}, volume = {10}, journal = {Quantitative Imaging in Medicine and Surgery}, number = {02}, publisher = {AME Publishing Company}, address = {Hong Kong, China}, doi = {10.21037/qims.2019.12.03}, pages = {340 -- 455}, abstract = {Background: For surgical fixation of bone fractures of the human hand, so-called Kirschner-wires (K-wires) are drilled through bone fragments. Due to the minimally invasive drilling procedures without a view of risk structures like vessels and nerves, a thorough training of young surgeons is necessary. For the development of a virtual reality (VR) based training system, a three-dimensional (3D) printed phantom hand is required. To ensure an intuitive operation, this phantom hand has to be realistic in both, its position relative to the driller as well as in its haptic features. The softest 3D printing material available on the market, however, is too hard to imitate human soft tissue. Therefore, a support-material (SUP) filled metamaterial is used to soften the raw material. Realistic haptic features are important to palpate protrusions of the bone to determine the drilling starting point and angle. An optical real-time tracking is used to transfer position and rotation to the training system. Methods: A metamaterial already developed in previous work is further improved by use of a new unit cell. Thus, the amount of SUP within the volume can be increased and the tissue is softened further. In addition, the human anatomy is transferred to the entire hand model. A subcutaneous fat layer and penetration of air through pores into the volume simulate shiftability of skin layers. For optical tracking, a rotationally symmetrical marker attached to the phantom hand with corresponding reference marker is developed. In order to ensure trouble-free position transmission, various types of marker point applications are tested. Results: Several cuboid and forearm sample prints lead to a final 30 centimeter long hand model. The whole haptic phantom could be printed faultless within about 17 hours. The metamaterial consisting of the new unit cell results in an increased SUP share of 4.32\%. Validated by an expert surgeon study, this allows in combination with a displacement of the uppermost skin layer a good palpability of the bones. Tracking of the hand marker in dodecahedron design works trouble-free in conjunction with a reference marker attached to the worktop of the training system. Conclusions: In this work, an optically tracked and haptically correct phantom hand was developed using dual-material 3D printing, which can be easily integrated into a surgical training system.}, subject = {Handchirurgie}, language = {en} }