@incollection{WeiglMuellerPangerletal., author = {Weigl, Stefan and M{\"u}ller, Max and Pangerl, Jonas and R{\"u}ck, Thomas}, title = {Scopes and Limits of Photoacoustic Spectroscopy in Modern Breath Analysis}, series = {Breath Analysis}, booktitle = {Breath Analysis}, publisher = {Springer nature}, isbn = {978-3-031-18526-7}, doi = {10.1007/11663_2022_22}, pages = {101 -- 159}, abstract = {Photoacoustic spectroscopy is a viable tool for trace gas detection in various application fields. In recent years, this technique has been exploited more and more for modern breath analysis as well. Within this chapter, a holistic overview of photoacoustic spectroscopy is presented, while maintaining the relationship to breath analysis. Therefore, a concise description of the fundamentals of photoacoustic spectroscopy is provided. This is essential for understanding the scopes and limits of this outstanding measurement technique being described within this chapter. In the past several different types of photoacoustic measurement setups for trace gas detection have emerged, including different light sources, modulation techniques, and detection schemes. These are described shortly and advantages as well as disadvantages, especially in relation to breath analysis, are highlighted. Though being a promising sensor principle, measurement devices based on photoacoustic spectroscopy are still rare on the sensor market, especially when it comes to trace gas detection in complex gas matrices, e.g., human breath exhale. One main reason is due to possible molecular interactions influencing the relaxational behavior of the analyte altering the sensor signal. Recent results shedding light on the intricate relaxational processes within complex gas matrices are discussed in detail, providing approaches to overcome this issue. Finally, various applications of photoacoustic spectroscopy in breath analysis are described demonstrating the great potential of this technology.}, language = {en} } @article{SteigerFoltanPhilippetal., author = {Steiger, Tamara and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Gruber, Michael and Bredthauer, Andre and Krenkel, Lars and Birkenmaier, Clemens and Lehle, Karla}, title = {Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients?}, series = {Artificial Organs}, volume = {43}, journal = {Artificial Organs}, number = {11}, publisher = {Wiley}, address = {Hoboken}, issn = {1525-1594}, doi = {10.1111/aor.13513}, pages = {1065 -- 1076}, abstract = {Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots-in particular, the presence of von Willebrand factor (vWF)-may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4 ',6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.}, language = {en} } @unpublished{PangerlMoserMuelleretal., author = {Pangerl, Jonas and Moser, Elisabeth and M{\"u}ller, Max and Weigl, Stefan and Jobst, Simon and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A Highly Sensitive Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor: Characterization and Multi-Component Spectra Recording in Synthetic Breath}, series = {SSRN Electronic Journal}, journal = {SSRN Electronic Journal}, publisher = {Elsevier}, doi = {10.2139/ssrn.4305376}, abstract = {Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8260 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbV in terms of ethanol and 250 pptV regarding acetone, our system is among the best performing presented so far.}, language = {en} } @article{HausFoltanPhilippetal., author = {Haus, Moritz and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Lingel, Maximilian P. and Krenkel, Lars and Gruber, Michael and Lehle, Karla}, title = {Neutrophil extracellular traps -a potential trigger for the development of thrombocytopenia during extracorporeal membrane oxygenation}, volume = {15}, publisher = {frontiers}, doi = {10.3389/fimmu.2024.1339235}, abstract = {Neutrophil extracellular traps (NETs) have recently emerged as a potential link between inflammation, immunity, and thrombosis, as well as other coagulation disorders which present a major challenge in the context of extracorporeal membrane oxygenation (ECMO). By examining blood from ECMO patients for NETs and their precursors and correlating them with clinical and laboratory biomarkers of coagulation and inflammation, this study aims to evaluate the association between the presence of NETs in the bloodstream of ECMO patients and the development of potentially severe coagulation disorders during ECMO therapy. Therefore, blood samples were collected from healthy volunteers (n=13) and patients receiving veno-venous (VV) ECMO therapy (n=10). To identify NETs and their precursors, DNA and myeloperoxidase as well as granulocyte marker CD66b were visualized simultaneously by immunofluorescence staining in serial blood smears. Differentiation of DNA-containing objects and identification of NETs and their precursors was performed semiautomatically by a specific algorithm using the shape and size of DNA staining and the intensity of MPO and CD66b signal. Neutrophil extracellular traps and their precursors could be detected in blood smears from patients requiring VV ECMO. Compared to volunteers, ECMO patients presented significantly higher rates of NETs and NET precursors as well as an increased proportion of neutrophil granulocytes in all detected nucleated cells. A high NET rate prior to the initiation of ECMO therapy was associated with both increased iL-6 and TNF-α levels as an expression of a high cytokine burden. These patients with increased NET release also presented an earlier and significantly more pronounced decrease in platelet counts and ATIII activity following initiation of therapy compared with patients with less elevated NETs. These findings provide further indications for the development of immune-mediated acquired thrombocytopenia in ECMO patients.}, language = {en} } @article{KleinNabbefeldHattabetal., author = {Klein, C. and Nabbefeld, T. and Hattab, H. and Meyer, D. and Jnawali, G. and Kammler, Martin and Meyer zu Heringdorf, Frank-Joachim and Golla-Franz, A. and M{\"u}ller, B. H. and Schmidt, Thomas and Henzler, M. and Horn-von Hoegen, Michael}, title = {Lost in reciprocal space? Determination of the scattering condition in spot profile analysis low-energy electron diffraction}, series = {Review of scientific instruments}, volume = {82}, journal = {Review of scientific instruments}, number = {3}, publisher = {American Institute of Physics}, doi = {10.1063/1.3554305}, abstract = {The precise knowledge of the diffraction condition, i.e., the angle of incidence and electron energy, is crucial for the study of surface morphology through spot profile analysis low-energy electron diffraction (LEED). We demonstrate four different procedures to determine the diffraction condition: employing the distortion of the LEED pattern under large angles of incidence, the layer-by-layer growth oscillations during homoepitaxial growth, a G(S) analysis of a rough surface, and the intersection of facet rods with 3D Bragg conditions.}, language = {en} } @misc{WeberSonarGerhardsetal., author = {Weber, Karsten and Sonar, Arne and Gerhards, Helene and Bittner, Uta and Krug, Henriette and Reuter-Oppermann, Melanie and Pumplun, Luisa and M{\"u}ller, Helene and Buxmann, Peter and Schneider, Diana and Zoglauer, Thomas}, title = {K{\"u}nstliche Intelligenz und Gesundheit}, editor = {Sonar, Arne and Weber, Karsten}, publisher = {Franz Steiner}, address = {Stuttgart}, isbn = {978-3-515-12977-0}, doi = {10.25162/9783515129770}, abstract = {Der Einsatz von k{\"u}nstlicher Intelligenz im Gesundheitsbereich verspricht besonders großen Nutzen durch eine bessere Versorgung sowie effizientere Abl{\"a}ufe und bietet damit letztlich auch {\"o}konomische Vorteile. Dem stehen unter anderem Bef{\"u}rchtungen entgegen, dass sich durch den Einsatz von k{\"u}nstlicher Intelligenz das Arzt-Patienten-Verh{\"a}ltnis ver{\"a}ndern k{\"o}nnte, Arbeitspl{\"a}tze gef{\"a}hrdet seien oder die {\"O}konomisierung des Gesundheitswesens einen weiteren Schub erfahren k{\"o}nnte. Zuweilen wird die Debatte um diese Technologie, zumal in der {\"O}ffentlichkeit, emotional und fern sachlicher Argumente gef{\"u}hrt. Die Autorinnen und Autoren untersuchen die Geschichte des KI-Einsatzes in der Medizin, deren {\"o}ffentliche Wahrnehmung, Governance der KI, die M{\"o}glichkeiten und Grenzen der Technik sowie Einsatzgebiete, die bisher noch nicht oder nur wenig im Fokus der Aufmerksamkeit waren. Dabei erweist sich die KI als leistungsf{\"a}higes Werkzeug, das zahlreiche ethische und soziale Fragen aufwirft, die bei der Einf{\"u}hrung anderer Technologien bereits gestellt wurden; allerdings gibt es auch neue Herausforderungen, denen sich Professionen, Politik und Gesellschaft stellen m{\"u}ssen.}, language = {de} } @article{BeyerWeigertQuicketal., author = {Beyer, Thomas and Weigert, Markus and Quick, Harald H. and Pietrzyk, Uwe and Vogt, Florian and Palm, Christoph and Antoch, Gerald and M{\"u}ller, Stefan P. and Bockisch, Andreas}, title = {MR-based attenuation correction for torso-PET/MR imaging}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {35}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {6}, doi = {10.1007/s00259-008-0734-0}, pages = {1142 -- 1146}, abstract = {Purpose MR-based attenuation correction (AC) will become an integral part of combined PET/MR systems. Here, we propose a toolbox to validate MR-AC of clinical PET/MRI data sets. Methods Torso scans of ten patients were acquired on a combined PET/CT and on a 1.5-T MRI system. MR-based attenuation data were derived from the CT following MR-CT image co-registration and subsequent histogram matching. PET images were reconstructed after CT- (PET/CT) and MR-based AC (PET/MRI). Lesion-to-background (L/B) ratios were estimated on PET/CT and PET/MRI. Results MR-CT histogram matching leads to a mean voxel intensity difference in the CT- and MR-based attenuation images of 12\% (max). Mean differences between PET/MRI and PET/CT were 19\% (max). L/B ratios were similar except for the lung where local misregistration and intensity transformation leads to a biased PET/MRI. Conclusion Our toolbox can be used to study pitfalls in MR-AC. We found that co-registration accuracy and pixel value transformation determine the accuracy of PET/MRI.}, subject = {Kernspintomografie}, language = {en} } @article{WeigertPietrzykMuelleretal., author = {Weigert, Markus and Pietrzyk, Uwe and M{\"u}ller, Stefan P. and Palm, Christoph and Beyer, Thomas}, title = {Whole-body PET/CT imaging}, series = {Zeitschrift f{\"u}r Medizinische Physik}, volume = {18}, journal = {Zeitschrift f{\"u}r Medizinische Physik}, number = {1}, doi = {10.1016/j.zemedi.2007.07.004}, pages = {59 -- 66}, abstract = {Aim Combined whole-body (WB) PET/CT imaging provides better overall co-registration compared to separate CT and PET. However, in clinical routine local PET-CT mis-registration cannot be avoided. Thus, the reconstructed PET tracer distribution may be biased when using the misaligned CT transmission data for CT-based attenuation correction (CT-AC). We investigate the feasibility of retrospective co-registration techniques to align CT and PET images prior to CT-AC, thus improving potentially the quality of combined PET/CT imaging in clinical routine. Methods First, using a commercial software registration package CT images were aligned to the uncorrected PET data by rigid and non-rigid registration methods. Co-registration accuracy of both alignment approaches was assessed by reviewing the PET tracer uptake patterns (visual, linked cursor display) following attenuation correction based on the original and co-registered CT. Second, we investigated non-rigid registration based on a prototype ITK implementation of the B-spline algorithm on a similar targeted MR-CT registration task, there showing promising results. Results Manual rigid, landmark-based co-registration introduced unacceptable misalignment, in particular in peripheral areas of the whole-body images. Manual, non-rigid landmark-based co-registration prior to CT-AC was successful with minor loco-regional distortions. Nevertheless, neither rigid nor non-rigid automatic co-registration based on the Mutual Information image to image metric succeeded in co-registering the CT and noAC-PET images. In contrast to widely available commercial software registration our implementation of an alternative automated, non-rigid B-spline co-registration technique yielded promising results in this setting with MR-CT data. Conclusion In clinical PET/CT imaging, retrospective registration of CT and uncorrected PET images may improve the quality of the AC-PET images. As of today no validated and clinically viable commercial registration software is in routine use. This has triggered our efforts in pursuing new approaches to a validated, non-rigid co-registration algorithm applicable to whole-body PET/CT imaging of which first results are presented here. This approach appears suitable for applications in retrospective WB-PET/CT alignment. Ziel Kombinierte PET/CT-Bildgebung erm{\"o}glicht verbesserte Koregistrierung von PET- und CT-Daten gegen{\"u}ber separat akquirierten Bildern. Trotzdem entstehen in der klinischen Anwendung lokale Fehlregistrierungen, die zu Fehlern in der rekonstruierten PET- Tracerverteilung f{\"u}hren k{\"o}nnen, falls die unregistrierten CT-Daten zur Schw{\"a}chungskorrektur (AC) der Emissionsdaten verwendet werden. Wir untersuchen daher die Anwendung von Bildregistrierungsalgorithmen vor der CT-basierten AC zur Verbesserung der PET-Aufnahmen. Methoden Mittels einer kommerziellen Registrierungssoftware wurden die CT-Daten eines PET/CT- Tomographen durch landmarken- und intensit{\"a}tsbasierte rigide (starre) und nicht-rigide Registrierungsverfahren r{\"a}umlich an die unkorrigierten PET-Emissionsdaten angepasst und zur AC verwendet. Zur Bewertung wurden die Tracerverteilungen in den PET-Bildern (vor AC, CT-AC, CT-AC nach Koregistrierung) visuell und mit Hilfe korrelierter Fadenkreuze verglichen. Zus{\"a}tzlich untersuchten wir die ITK-Implementierung der bekannten B-spline basierten, nicht-rigiden Registrierungsans{\"a}tze im Hinblick auf ihre Verwendbarkeit f{\"u}r die multimodale PET/CT-Ganzk{\"o}rperregistrierung. Ergebnisse Mittels landmarkenbasierter, nicht-rigider Registrierung konnte die Tracerverteilung in den PET-Daten lokal verbessert werden. Landmarkenbasierte rigide Registrierung f{\"u}hrte zu starker Fehlregistrierung in entfernten K{\"o}rperregionen. Automatische rigide und nicht-rigide Registrierung unter Verwendung der Mutual-Information-{\"A}hnlichkeitsmetrik versagte auf allen verwendeten Datens{\"a}tzen. Die automatische Registrierung mit B-spline-Funktionen zeigte vielversprechende Resultate in der Anwendung auf einem {\"a}hnlich gelagerten CT-MR-Registrierungsproblem. Fazit Retrospektive, nicht-rigide Registrierung unkorrigierter PET- und CT-Aufnahmen aus kombinierten Aufnahmensystemen vor der AC kann die Qualit{\"a}t von PET-Aufnahmen im klinischen Einsatz verbessern. Trotzdem steht bis heute im klinischen Alltag keine validierte, automatische Registrierungssoftware zur Verf{\"u}gung. Wir verfolgen dazu Ans{\"a}tze f{\"u}r validierte, nicht-rigide Bildregistrierung f{\"u}r den klinischen Einsatz und pr{\"a}sentieren erste Ergebnisse.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @misc{BeyerWeigertPalmetal., author = {Beyer, Thomas and Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Vogt, Florian and Martinez, M.J. and Bockisch, Andreas}, title = {Towards MR-based attenuation correction for whole-body PET/MR imaging}, series = {The Journal of Nuclear Medicine}, volume = {47}, journal = {The Journal of Nuclear Medicine}, number = {Suppl. 1}, pages = {384P}, subject = {Kernspintomografie}, language = {en} } @misc{WeigertBeyerQuicketal., author = {Weigert, Markus and Beyer, Thomas and Quick, Harald H. and Pietrzyk, Uwe and Palm, Christoph and M{\"u}ller, Stefan P.}, title = {Generation of a MRI reference data set for the validation of automatic, non-rigid image co-registration algorithms}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A116}, subject = {Kernspintomografie}, language = {en} } @misc{WeigertPalmQuicketal., author = {Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Beyer, Thomas}, title = {Template for MR-based attenuation correction for whole-body PET/MR imaging}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A115}, subject = {Kernspintomografie}, language = {en} } @article{LehlePhilippKrenkeletal., author = {Lehle, Karla and Philipp, Alois and Krenkel, Lars and Gruber, Michael and Hiller, Karl-Anton and M{\"u}ller, Thomas and Lubnow, Matthias}, title = {Thrombocytopenia During Venovenous Extracorporeal Membrane Oxygenation in Adult Patients With Bacterial, Viral, and COVID-19 Pneumonia}, series = {ASAIO Journal}, journal = {ASAIO Journal}, publisher = {Wolters Kluwer}, issn = {1058-2916}, doi = {10.1097/MAT.0000000000002383}, abstract = {Contact of blood with artificial surfaces triggers platelet activation. The aim was to compare platelet kinetics after venovenous extracorporeal membrane oxygenation (V-V ECMO) start and after system exchange in different etiologies of acute lung failure. Platelet counts and coagulation parameters were analyzed from adult patients with long and exchange-free (≥8 days) ECMO runs (n = 330) caused by bacterial (n = 142), viral (n = 76), or coronavirus disease 2019 (COVID-19) (n = 112) pneumonia. A subpopulation requiring a system exchange and with long, exchange-free runs of the second oxygenator (≥7 days) (n = 110) was analyzed analogously. Patients with COVID-19 showed the highest platelet levels before ECMO implantation. Independent of the underlying disease and ECMO type, platelet counts decreased significantly within 24 hours and reached a steady state after 5 days. In the subpopulation, at the day of a system exchange, platelet counts were lower compared with ECMO start, but without differences between underlying diseases. Subsequently, platelets remained unchanged in the bacterial pneumonia group, but increased in the COVID-19 and viral pneumonia groups within 2-4 days, whereas D-dimers decreased and fibrinogen levels increased. Thus, overall platelet counts on V-V ECMO show disease-specific initial dynamics followed by an ongoing consumption by the ECMO device, which is not boosted by new artificial surfaces after a system exchange.}, language = {en} } @misc{KranzWagnerPointneretal., author = {Kranz, Michael and Wagner, Maria Stella and Pointner, Daniel and Waldbauer, Selina and M{\"u}ller, Thomas and Lubnow, Matthias and Foltan, Maik and Krenkel, Lars and Lehle, Karla}, title = {Polymeric Embedding of Membrane Lungs: A Novel Method for Histological Investigations of Intra-Device Clot Formation}, series = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, journal = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, language = {en} } @misc{KranzWagnerKrenkeletal., author = {Kranz, Michael and Wagner, Maria Stella and Krenkel, Lars and M{\"u}ller, Thomas and Lubnow, Matthias and Philipp, Alois and Lehle, Karla}, title = {Clot Localization within Membrane Lungs using different Imaging Methods and Histological Clot Characterization as a way to prevent Thrombosis in Extracorporeal Membrane Oxygenation}, volume = {2023}, language = {en} } @misc{KoesterKranzWagneretal., author = {K{\"o}ster, Leonie and Kranz, Michael and Wagner, Maria Stella and Foltan, Maik and M{\"u}ller, Thomas and Lubnow, Matthias and Krenkel, Lars and Lehle, Karla}, title = {Histological Investigations of Intra-Device Clot Formation in ECMO Pumps}, series = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, journal = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, language = {en} }