@incollection{KahledReichlingBruhnsetal., author = {Kahled, W. and Reichling, S. and Bruhns, Otto T. and B{\"o}se, Holger and Baumann, Michael and Egersd{\"o}rfer, Stefan and Klein, Dagmar and Tunayer, A. and Freimuth, Herbert and Lorenz, A. and Pessavento, A. and Ermert, Helmut}, title = {Palpation Imaging using a Haptic System for Virtual Reality applications in Medicine}, series = {Medicine meets virtual reality 12}, booktitle = {Medicine meets virtual reality 12}, editor = {Westwood, James D. and Haluck, Randy S.}, publisher = {IOS Press}, pages = {147 -- 153}, language = {en} } @inproceedings{KhaledBruhnsReichlingetal., author = {Khaled, W. and Bruhns, Otto T. and Reichling, S. and B{\"o}se, Holger and Baumann, Michael and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Meier, Alexander and Klein, Dagmar and Freimuth, Herbert and Ermert, Helmut}, title = {A haptic system for virtual reality applications based on ultrasound elastography and electrorheological fluids}, series = {Acoustical Imaging (ACIM)}, volume = {27}, booktitle = {Acoustical Imaging (ACIM)}, publisher = {Springer}, address = {Dordrecht}, isbn = {978-90-481-6652-7}, issn = {0270-5117}, doi = {10.1007/978-1-4020-2402-3_85}, pages = {667 -- 674}, abstract = {Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. Malignant tumors are significantly stiffer and more immobile than surrounding healthy tissue. Hard calcifications in vessels occur due to arteriosclerosis. The problem is, that such information is usually not available or can only be obtained by manual palpation, which is subjective and limited in sensitivity. It requires intuitive assessment and does not allow quantitative documentation. Unfortunately, none of the established medical imaging equipment such as magnetic resonance imaging (MRI) or X-ray computed tomography (CT) can provide direct measure of tissue elasticity. On the one hand a suitable sensor is required for quantitative measurement of mechanical tissue properties. On the other hand there is also some need for a realistic haptic display of such tissue properties. Suitable actuator arrays with high spatial resolution acting in real time are required. A haptic sensor actuator system is presented in this paper including a sensitive sensor part and an actuator array for different applications. The mechanical consistency of an object is to be locally specified using a sensor system and represented perceptibly in a remote position on an actuator system for the user. The sensor system uses ultrasound (US) elastography, whereas the actuator array is based on electrorheological (ER) fluids.}, language = {en} } @inproceedings{KhaledBruhnsReichlingetal., author = {Khaled, W. and Bruhns, Otto T. and Reichling, S. and B{\"o}se, Holger and Baumann, Michael and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Meier, Alexander and Klein, Dagmar and Freimuth, Herbert and Ermert, Helmut}, title = {A haptic sensor-actuator-system based on ultrasound elastography and electrorheological fluids for virtual reality applications in medicine}, series = {CARS 2003 : computer assisted radiology and surgery ; proceedings of the 17th International Congress and Exhibition London, June 25 - 28, 2003}, booktitle = {CARS 2003 : computer assisted radiology and surgery ; proceedings of the 17th International Congress and Exhibition London, June 25 - 28, 2003}, publisher = {Elsevier}, address = {Amsterdam}, pages = {1354}, abstract = {Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication.}, language = {en} } @article{KhaledErmertBruhnsetal., author = {Khaled, W. and Ermert, Helmut and Bruhns, Otto T. and Reichling, S. and B{\"o}se, Holger and Baumann, Michael and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Meier, Alexander and Klein, Dagmar and Freimuth, Herbert}, title = {Haptic sensor-actuator-system based on ultrasound elastography and electrorheological fluids for virtual reality applications in medicine}, series = {Studies in health technology and informatics, Medicine Meets Virtual Reality (MMVR)}, volume = {11}, journal = {Studies in health technology and informatics, Medicine Meets Virtual Reality (MMVR)}, number = {94}, publisher = {IOS Press}, pages = {144 -- 150}, abstract = {Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication.}, language = {de} } @inproceedings{KhaledReichlingBruhnsetal., author = {Khaled, W. and Reichling, S. and Bruhns, Otto T. and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Baumann, Michael and B{\"o}se, Holger and Klein, Dagmar and Freimuth, Herbert and Tunayar, A. and Lorenz, A. and Pessavento, A. and Ermert, Helmut}, title = {Palpation imaging using a haptic system for virtual reality applications in medicine}, series = {Perspective in image-guided surgery : proceedings of the Scientific Workshop on Medical Robotics, Navigation, and Visualization : RheinAhrCampus Remagen, Germany, 11-12 March}, booktitle = {Perspective in image-guided surgery : proceedings of the Scientific Workshop on Medical Robotics, Navigation, and Visualization : RheinAhrCampus Remagen, Germany, 11-12 March}, publisher = {World Scientific Publ.}, address = {Singapore}, pages = {407 -- 414}, language = {en} } @inproceedings{KhaledReichlingBruhnsetal., author = {Khaled, W. and Reichling, S. and Bruhns, Otto T. and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Baumann, Michael and B{\"o}se, Holger and Klein, Dagmar and Freimuth, Herbert and Tunayar, A. and Lorenz, A. and Pessavento, A. and Ermert, Helmut}, title = {Palpation Imaging using a Haptic System for Virtual Reality Applications in Medicine}, series = {Proceedings of the 12th Annual Medicine Meets Virtual Reality Conference: - Building a Better You: The Next Tools for Medical Education, Diagnosis, and Care. - Medicine Meets Virtual Reality (MMVR) - Newport Beach (California, USA). 2004}, booktitle = {Proceedings of the 12th Annual Medicine Meets Virtual Reality Conference: - Building a Better You: The Next Tools for Medical Education, Diagnosis, and Care. - Medicine Meets Virtual Reality (MMVR) - Newport Beach (California, USA). 2004}, language = {en} } @article{KhaledBruhnsReichlingetal., author = {Khaled, W. and Bruhns, Otto T. and Reichling, S. and B{\"o}se, Holger and Baumann, Michael and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Meier, Alexander and Klein, Dagmar and Freimuth, Herbert and Ermert, Helmut}, title = {A haptic system for virtual reality applications based on ultrasound elastography and electrorheological fluids}, series = {Acoustical Imaging}, journal = {Acoustical Imaging}, number = {27}, publisher = {Kluver Academic}, address = {Dordrecht \& New York}, doi = {10.1007/978-1-4020-2402-3_85}, pages = {667 -- 675}, language = {en} }