@misc{vanderWeerdBierlMatysik, author = {van der Weerd, Bastiaan and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A Conductivity Probe for Determination of the Carbon Dioxide Tension at the Oxygenator Exhaust Outlet during Extracorporeal Membrane Oxygenation (ECMO)}, series = {Proceedings of the 9th ISC Modern Analytical Chemistry 2013, Prag}, journal = {Proceedings of the 9th ISC Modern Analytical Chemistry 2013, Prag}, language = {en} } @misc{RueckHofmannBierl, author = {R{\"u}ck, Thomas and Hofmann, Matthias and Bierl, Rudolf}, title = {Development of a miniaturized photoacoustic multigas sensing system for trace gas measurement}, series = {17th International Conference on Photoacoustic and Photothermal Phenomena, Oct. 20-24, 2013, Suzhou China}, journal = {17th International Conference on Photoacoustic and Photothermal Phenomena, Oct. 20-24, 2013, Suzhou China}, language = {en} } @misc{RueckMatysikBierl, author = {R{\"u}ck, Thomas and Matysik, Frank-Michael and Bierl, Rudolf}, title = {Development of a miniaturized photoacoustic multigas sensing system for trace gas measurement}, series = {analytica conference 2014, 1. bis 4. April, M{\"u}nchen}, journal = {analytica conference 2014, 1. bis 4. April, M{\"u}nchen}, language = {en} } @misc{RueckMatysikBierl, author = {R{\"u}ck, Thomas and Matysik, Frank-Michael and Bierl, Rudolf}, title = {Comparison of acoustic detectors for use in miniaturized photoacoustic devices designed for nitrogen dioxide trace gas measurement}, series = {ANAKON, 23.-26.3.2015, Graz}, journal = {ANAKON, 23.-26.3.2015, Graz}, language = {en} } @article{PangerlSukulRuecketal., author = {Pangerl, Jonas and Sukul, Pritam and R{\"u}ck, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone}, series = {Photoacoustics}, volume = {38}, journal = {Photoacoustics}, publisher = {Elsevier}, issn = {2213-5979}, doi = {10.1016/j.pacs.2024.100604}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-71279}, pages = {12}, abstract = {n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.}, language = {en} } @article{EscherRueckJobstetal., author = {Escher, Lukas and R{\"u}ck, Thomas and Jobst, Simon and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Photodissociation-Driven Photoacoustic Spectroscopy with UV-LEDs for Ozone Detection}, series = {Photoacoustics}, volume = {43}, journal = {Photoacoustics}, publisher = {Elsevier BV}, issn = {2213-5979}, doi = {10.1016/j.pacs.2025.100718}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-80076}, pages = {16}, abstract = {This study presents the development and evaluation of a UV-LED based photoacoustic (PA) measurement system for ozone (O3) detection to demonstrate its potential for low-cost and accurate sensing while for the first time addressing the importance of photodissociation for PA signal generation for O3 in the UV range. With a detection limit of 7.9 ppbV, the system exhibits a significant advancement over state-of-the-art UV-PA O3 detection and is on par with laser-based setups. Following a novel discussion of the PA signal arising from photodissociation and its products, cross-sensitivity effects due to environmental factors such as temperature and gas composition were systematically analyzed. A digital twin driven compensation for these influences was implemented and evaluated. Despite the challenges associated with modeling the effects of H2O and CO2, the PA system shows considerable potential, though further studies in real world applications must be conducted.}, language = {en} } @article{HauslerHolznerEhrnspergeretal., author = {Hausler, Peter and Holzner, Lukas and Ehrnsperger, Matthias and Bierl, Rudolf}, title = {Evaluation of the creep strength of samples produced by fused deposition modeling}, series = {Open Engineering}, volume = {14}, journal = {Open Engineering}, number = {1}, publisher = {de Gruyter}, doi = {10.1515/eng-2024-0084}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-79760}, pages = {10}, abstract = {Data sheets for 3D printing materials typically include softening temperature, impact strength, tensile strength, and stiffness. However, creep strength, an important parameter for components used over an extended period, is usually not included. Nevertheless, this parameter is of significant importance for components that are used over an extended period of time.This study compares the long-term creep behavior of a selection of materials that are commonly used in fused deposition modeling 3D printing. The materials under investigation are acrylonitrile butadiene styrene, acrylonitrile styrene acrylate, polylactic acid, and polycarbonate. In addition, the influence of fiber reinforcements on these materials is also examined. A simple, reproducible test procedure is proposed for users to determine and compare creep resistance of materials. This enables developers to select materials suitable for their own requirements on creep resistance and allows 3D-printing users to compare different materials. Results suggest that fiber reinforcement generally improves creep stability in 3D-printing materials, with GreenTEC Pro Carbon and add:north PC Blend HT LCF showing the most promise in this study.}, language = {en} } @article{ReinkerBlaesingBierletal., author = {Reinker, Lukas and Bl{\"a}sing, Dominic and Bierl, Rudolf and Ulbricht, Sabina and Dendorfer, Sebastian}, title = {Correlation of Acceleration Curves in Gravitational Direction for Different Body Segments during High-Impact Jumping Exercises}, series = {sensors}, volume = {23}, journal = {sensors}, number = {4}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/s23042276}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-58217}, abstract = {Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83-0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20-0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs.}, language = {en} } @inproceedings{BierlBoehmFraunhofferetal., author = {Bierl, Rudolf and Boehm, M. and Fraunhoffer, Judith and Gardeia, Armin and Mottok, J{\"u}rgen and Schneider, Ralph and Streubel, J.}, title = {"Regensburger Modell zu den P-Seminaren" - Ein Konzept zur Gestaltung der Schnittstelle Gymnasium - Hochschule und zur Praxis einer kooperativen Lehr-Lern-Didaktik f{\"u}r Informationstechnik}, series = {3rd Embedded Software Engineering Congress, 7. bis 9. Dezember, Sindelfingen}, booktitle = {3rd Embedded Software Engineering Congress, 7. bis 9. Dezember, Sindelfingen}, publisher = {Vogel Business Media}, address = {W{\"u}rzburg}, language = {de} } @article{WeiglFeldmeierBierletal., author = {Weigl, Stefan and Feldmeier, Florian and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Photoacoustic detection of acetone in N2 and synthetic air using a high power UV LED}, series = {Sensors Actuators B Chemical}, volume = {316}, journal = {Sensors Actuators B Chemical}, number = {August}, publisher = {Elsevier}, doi = {10.1016/j.snb.2020.128109}, pages = {1 -- 11}, abstract = {The performance of a photoacoustic trace gas sensor for the detection of acetone in N2 and synthetic air is reported. The sensor system utilises an amplitude modulated UV LED. The light source has an emission maximum at 278 nm and a maximum CW output power of 300 mW according to the datasheet. Three different collimating and focusing approaches have been investigated to guide the highly divergent LED light into the acoustic resonator of the photoacoustic measurement cell. A 3D printed aluminium cell was designed to optimize light coupling by simultaneously minimizing the photoacoustic background signal generation. Hence, the diameter of the resonator was set to a comparable large diameter of 10 mm and the inner walls of the resonator were mirror polished. The additive manufacturing procedure allowed for integration of a spirally formed gas channel, enabling gas heating prior to detection. The sensor performance was investigated by measuring acetone in N2 and synthetic air at different concentrations. The UV LED current was set to 86 \% of the maximum value according to the datasheet of the light source in order to increase the lifetime and thermal stability. An Allan-Werle deviation analysis validates a stable sensor performance. The limit of detection (LoD) was determined at a 3σ noise level with a 10 s lock-in amplifier time constant by sampling data points over 20 s with a data acquisition rate of 5 Hz. LoDs of 80.8 ppbV and 19.6 ppbV were obtained for acetone in N2 and synthetic air, respectively.}, language = {en} } @article{WeiglWittmannRuecketal., author = {Weigl, Stefan and Wittmann, Elisabeth and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Effects of ambient parameters and cross-sensitivities from O2, CO2 and H2O on the photoacoustic detection of acetone in the UV region}, series = {Sensors Actuators B Chemical}, journal = {Sensors Actuators B Chemical}, number = {328}, publisher = {Elsevier}, issn = {0925-4005}, doi = {10.1016/j.snb.2020.129001}, abstract = {We present a sensitive UV LED photoacoustic setup for the detection of gaseous acetone and discuss its applicability towards breath analysis. We investigated the performance of the sensor for low acetone concentrations down to 0.1 parts per million (ppmV). The influences of temperature, flow, pressure, optical power and LED duty cycle on the measured signal have been examined. To gain a better understanding of the different effects on the photoacoustic signal, correlation analysis was applied and feature importance was determined using a large measured dataset. Furthermore, the cross-sensitivities towards O2, CO2 and H2O have been studied extensively. Finally, the sensor's performance to detect acetone between 0.1-1 ppmV within gas mixtures simulating breath exhale conditions has been investigated, too. With a limit of detection (LoD) of 12.5 parts per billion (ppbV) (3σ) measured under typical breath exhale gas mixture conditions, the sensor demonstrated a high potential for the application of acetone detection in human breath analysis.}, language = {en} } @inproceedings{HauslerJobstFischeretal., author = {Hausler, Peter and Jobst, Simon and Fischer, Johannes and Roth, Carina and Bierl, Rudolf}, title = {Homogeneous Light Source for Surface Plasmon Resonance Imaging}, series = {PHOTOPTICS 2020: proceedings of the 8th International Conference on Photonics, Optics and Laser Technology, Valletta, Malta, February 27-29, 2020}, booktitle = {PHOTOPTICS 2020: proceedings of the 8th International Conference on Photonics, Optics and Laser Technology, Valletta, Malta, February 27-29, 2020}, publisher = {SCITEPRESS - Science and Technology Publications}, doi = {10.5220/0009168701630167}, pages = {163 -- 167}, abstract = {We describe how to build a homogeneous light source for Surface Plasmon Resonance Imaging (SPRi) which mainly finds its applications in pharmaceutical screening and biotechnology so far. SPR spectroscopy is a label-free, non-destructive and highly sensitive measurement principle for detecting changes in the refractive index in close vicinity of a gold surface. A transfer of this technology to a miniaturized sensor will broaden the range of possible applications. Commercial SPR assays are mainly working with a small number of sensing spots. In contrast, the SPR imaging system shown here will allow the use of an array of many sensing spots. In combination with chemical receptors designed as an artificial nose or an electronic tongue, the simultaneous detection of many analytes is envisioned. So far, lasers or other inhomogeneous light sources were used to illuminate the sensing surface, which is decreasing the systems sensitivity. We show a compact ( 300mm2) homogeneous top hat profile. The combination of a high bit-resolution camera with our new light source enables a reflectivity based surface plasmon resonance imaging system with a high refractive index unit (RIU) resolution.}, language = {en} } @inproceedings{GschossmannJobstMottoketal., author = {Gschossmann, Andreas and Jobst, Simon and Mottok, J{\"u}rgen and Bierl, Rudolf}, title = {A Measure of Confidence of Artificial Neural Network Classifiers}, series = {ARCS Workshop 2019; 32nd International Conference on Architecture of Computing Systems, 20-21 May 2019, Copenhagen, Denmark}, booktitle = {ARCS Workshop 2019; 32nd International Conference on Architecture of Computing Systems, 20-21 May 2019, Copenhagen, Denmark}, publisher = {VDE-Verlag}, address = {Berlin}, pages = {153 -- 157}, abstract = {Confidence in results of an Artificial Neural Networks (ANNs) is increased by preferring to reject data, that is not trustful, instead of risking a misclassification. For this purpose a model is proposed that is able to recognize data, which differs significantly from the training data, during inference. The proposed model observes all activations of the hidden layers, as well as input and output layers of an ANN in a grey-box view. To make ANNs more robust in safety critical applications, this model can be used to reject flawed data, that is suspected to decrease the accuracy of the model. If this information is logged during inference, it can be used to improve the model, by training it specifically with the missing information. An experiment on the MNIST dataset is conducted and its results are discussed.}, language = {en} }