@article{PangerlSukulRuecketal., author = {Pangerl, Jonas and Sukul, Pritam and R{\"u}ck, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone}, series = {Photoacoustics}, volume = {38}, journal = {Photoacoustics}, publisher = {Elsevier}, issn = {2213-5979}, doi = {10.1016/j.pacs.2024.100604}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-71279}, pages = {12}, abstract = {n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.}, language = {en} } @article{EscherRueckJobstetal., author = {Escher, Lukas and R{\"u}ck, Thomas and Jobst, Simon and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Photodissociation-Driven Photoacoustic Spectroscopy with UV-LEDs for Ozone Detection}, series = {Photoacoustics}, volume = {43}, journal = {Photoacoustics}, publisher = {Elsevier BV}, issn = {2213-5979}, doi = {10.1016/j.pacs.2025.100718}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-80076}, pages = {16}, abstract = {This study presents the development and evaluation of a UV-LED based photoacoustic (PA) measurement system for ozone (O3) detection to demonstrate its potential for low-cost and accurate sensing while for the first time addressing the importance of photodissociation for PA signal generation for O3 in the UV range. With a detection limit of 7.9 ppbV, the system exhibits a significant advancement over state-of-the-art UV-PA O3 detection and is on par with laser-based setups. Following a novel discussion of the PA signal arising from photodissociation and its products, cross-sensitivity effects due to environmental factors such as temperature and gas composition were systematically analyzed. A digital twin driven compensation for these influences was implemented and evaluated. Despite the challenges associated with modeling the effects of H2O and CO2, the PA system shows considerable potential, though further studies in real world applications must be conducted.}, language = {en} } @unpublished{PangerlSukulRuecketal., author = {Pangerl, Jonas and Sukul, Pritam and R{\"u}ck, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An Inexpensive Uv-Led Photoacoustic Based Real-Time Sensor-System Detecting Exhaled Trace-Acetone}, publisher = {Elsevier}, doi = {10.2139/ssrn.4724198}, abstract = {In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 6.4 ppbV and an NNEA of 1.1E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.}, language = {en} }