@misc{NeidhartHallasHinrichsenetal., author = {Neidhart, Thomas and Hallas, Martin and Hinrichsen, Volker and Tenzer, Michael and Neumann, Claus}, title = {Langzeitversuche an einer direkt erdverlegten DC GIL: Bodenmechanische und thermische Wechselwirkungen bei Bettung in zeitweise fließf{\"a}higem Verf{\"u}llbaustoff}, series = {22. Fachtagung Hochspannungsschaltanlagen: Anwendungen, Betrieb und Erfahrungen am 6. Okt. 2020, TU Darmstadt}, journal = {22. Fachtagung Hochspannungsschaltanlagen: Anwendungen, Betrieb und Erfahrungen am 6. Okt. 2020, TU Darmstadt}, language = {de} } @techreport{NeidhartSchuster, author = {Neidhart, Thomas and Schuster, Markus}, title = {Feldversuch zur Untersuchung des Bodenverbesserungseffekts durch Hybridinjektionsk{\"o}rper®}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg, Fakult{\"a}t Bauingenieurwesen, Labor f{\"u}r Geotechnik}, doi = {10.35096/othr/pub-2172}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-21723}, pages = {94}, abstract = {Die Bodenverbesserung mit HybridInjection® der Firma URETEK Deutschland GmbH ist ein Injektionsverfahren, das speziell unter bestehenden Bauwerken als Nachgr{\"u}ndung oder Gr{\"u}ndungsverst{\"a}rkung zum Einsatz kommt, welche auf sehr schlecht tragf{\"a}higem Untergrund gegr{\"u}ndet sind. Dabei werden d{\"u}nne, mit einem Geotextil umwickelte Stangen (Injektionslanzen {\O} = 12 mm) in den Untergrund eingebracht und anschließend das Textil mit Hilfe eines speziellen Harzes expandiert. Dadurch wird der umliegende Boden durch Verdr{\"a}ngung {\"u}berwiegend radial verdr{\"a}ngt und verdichtet. Zudem wirken die moderat steifen, s{\"a}ulenartigen Expansionsk{\"o}rpern als Lastabtragungselemente und entlasten den Boden dazwischen, womit sie als Bodenverbesserungss{\"a}ulen eingeordnet werden k{\"o}nnen. Ziel der gemeinsamen Forschungsarbeit ist es diesen Verbesserungseffekt messtechnisch zu erfassen und zu beziffern, um dadurch das Produkt wirtschaftlicher und auf die jeweilige Lastsituation anbieten zu k{\"o}nnen. Dazu wurde auf einem Versuchsfeld eine 6,0 m² große Stahlbetonplatte, welche das Fundament eines Geb{\"a}udes darstellen soll, mit Hilfe eines 1,5 MN-Hydraulikzylinders in verschiedenen Stufen belastet und die daraus resultierenden Setzungen des Bodens gemessen. Dies geschah zun{\"a}chst ohne und anschließend mit vier, rechteckig unter der Betonplatte angeordneten Expansionsk{\"o}rpern der Firma URETEK. Der Vorher-Nachher-Vergleich der verschiedenen Auswertungen zeigte, dass der Boden nach dem Einbau der HybridInjection® insgesamt deutlich steifer reagiert. Verglichen wurden daf{\"u}r das Maß der Setzungen, die Kriechzahl in Anlehnung an die EA-Pf{\"a}hle, der Verformungsmodul in Anlehnung an den Lastplattendruckversuch, Setzungen und E-Moduln in der Tiefe ermittelt aus Extensometermessungen und zuletzt die Schlagzahlen leichter Rammsondierungen. Die Verbesserungsfaktoren fallen recht unterschiedlich aus und belaufen sich auf {\"A}nderungen um bis zu + 68\% im Vergleich zum Ausgangszustand ohne Bodenverbesserung.}, subject = {Baugrund}, language = {de} } @misc{GoemmelNeidhart, author = {G{\"o}mmel, Roland and Neidhart, Thomas}, title = {Ber{\"u}cksichtigung von StS beim Nachweis der Gesamtstandsicherheit}, address = {Regensburg}, language = {de} } @article{LerchNeidhartBubeniceketal., author = {Lerch, Maximilian and Neidhart, Thomas and Bubenicek, Michal and Pandrea, Paul}, title = {Ableitung der Tragf{\"a}higkeit aus Probebelastungen an Betonstopfs{\"a}ulen}, series = {geotechnik}, volume = {43}, journal = {geotechnik}, number = {4}, publisher = {Ernst \& Sohn}, doi = {10.1002/gete.202000030}, pages = {298 -- 306}, abstract = {Neben den konventionellen Pfahlgr{\"u}ndungen werden bei ung{\"u}nstigen Baugrundverh{\"a}ltnissen oft pfahlartige Tragglieder verwendet, um den Anforderungen an Gebrauchstauglichkeit und Standsicherheit bei der Gr{\"u}ndung von Bauwerken gerecht zu werden. Um Erkenntnisse {\"u}ber das Tragverhalten der S{\"a}ulen zu erlangen, wurden Probebelastungen durchgef{\"u}hrt. Hierbei kamen statische und dynamische Probebelastungen zum Einsatz. Die Tragglieder wurden mit faseroptischer Messtechnik ausgestattet, um eine getrennte Ermittlung der Mantel- und Spitzenwiderst{\"a}nde zu erm{\"o}glichen. Die aus den Messungen gewonnenen Erkenntnisse zum Lastabtragungsverhalten zeigen, dass die pfahlartigen Tragglieder aufgrund ihrer Herstellung h{\"o}here Gesamt- und insbesondere Mantelwiderst{\"a}nde als Schneckenortbetonpf{\"a}hle, die als Referenz mit gleichem Durchmesser und gleicher Einbindel{\"a}nge in identischen Baugrundverh{\"a}ltnissen gefertigt wurden, aufweisen. Es wird gezeigt, dass praxis{\"u}bliche Bemessungsverfahren das gemessene Last-Setzungs-Verhalten nur bedingt wiedergeben. Die Versuchsergebnisse stellen die Grundlage f{\"u}r zuk{\"u}nftige Anpassungen der Bemessungsverfahren f{\"u}r pfahlartige Tragglieder dar.}, language = {de} } @inproceedings{LerchNeidhartBubenicek, author = {Lerch, Maximilian and Neidhart, Thomas and Bubenicek, Michal}, title = {Fibre optic instrumentation of vibro concrete columns and surrounding ground for static and dynamic load tests}, series = {Zbornik Radova GEO-EXPO 2020: Proceedings - Scientific and expert conference GEO-EXPO 2020}, booktitle = {Zbornik Radova GEO-EXPO 2020: Proceedings - Scientific and expert conference GEO-EXPO 2020}, publisher = {Društvo za geotehniku u Bosni i Hercegovini}, doi = {10.35123/GEO-EXPO_2020_6}, pages = {40 -- 49}, abstract = {Instrumentation of full displacement pile like elements - at Keller called as vibro concrete columns (VCC) - is practically impossible due to utilisation of heavy deep vibro technique during the production and absence of any steel reinforcement. Thanks to cooperation between Keller and Faculty of Civil Engineering of OTH Regensburg a special procedure for post-instrumentation was developed that allows for the axial strain measurement in VCC during the loading tests. The instrumentation comprises among others optical fibre components. The procedure has been deployed on a test site during static as well as dynamic load tests. There were two different types of instrumentation implemented according to art of the load tests. Further there were robust piezometers installed in the soil in advance next to the VCC that allowed for continuous pore water pressure measurements during the load tests. Purpose of the instrumentation deployed is above all to obtain data for effective design of VCC.}, language = {en} } @inproceedings{NeidhartLerchWiesingeretal., author = {Neidhart, Thomas and Lerch, Maximilian and Wiesinger, Doris and Hallas, Martin and Hinrichsen, Volker and Tenzer, Michael}, title = {Long-Term Tests of a DC Gas Insulated Transmission Line (DC GIL) embedded in Temporally Flowable Backfill: Soil-Mechanical and Thermic Interaction}, series = {VDE Hochspannungstechnik: ETG-Fachtagung, 9. - 11. November 2020, Online-Veranstaltung}, booktitle = {VDE Hochspannungstechnik: ETG-Fachtagung, 9. - 11. November 2020, Online-Veranstaltung}, edition = {CD-ROM}, publisher = {VDE-Verlag}, address = {Berlin}, isbn = {978-3-8007-5353-6}, pages = {518 -- 524}, abstract = {At present DC transmission systems for long distance transmission are of special interest, particularly with regard to transmission systems that proved ability for directly buried installation. Some service experience has been collected with directly buried AC GIL technology, but none with directly buried DC GIL. First pilot projects with directly buried AC GIL were designed conservative regarding the mechanical GIL support and the maximum allowable current. The aim is to optimize the mechanical and thermal design of directly buried DC GIL to offer cost efficient transmission line solutions. Therefore, a ±550 kV DC GIL prototype with a current carrying capacity of 5000 A is currently investigated in a HVDC test facility, both in above-ground installation and a buried installation. This report presents results gained on the embedded installation for studying the soil mechanics and long-term thermic interaction with the backfill material and the adjacent soil. A DC GIL with a total length of 130 m is embedded in a temporarily flowable backfill ("TFB") as re-use of the excavated soil on site, which minimizes transportation costs and energy use. TFB is characterized by high contact forces that restrain the DC GIL displacements and by stable thermal conductivity, which optimizes the heat transfer. In order to monitor the mechanical soil-structure-interaction ("SSI"), various temperatures and moisture content sensors were installed inside and around the DC GIL, in the TFB and the adjacent soil as well down to 4 m below the ground surface. Displacement and strain sensors measured the elongations and dilatations of the embedded enclosure tube. Compressive stresses caused by restrained displacements are monitored with load cells. A fiber optical cable is used to monitor the temperatures in the aluminum conductor, on top and at the base of the enclosure tube, as well as in the TFB and the sand cover layer and the adjacent soil. The measurements were completed with some single sensors for temperature, moisture content and porewater-tensions which were mainly concentrated nearby the DC GIL in the TFB and the cover layer. During 15 months, several load cycles impact on the embedded DC GIL. Each load cycle consists of a DC current feed of 5000 A for 4 weeks followed by another 4 weeks without current. Since the SSI is independent of voltage stress, this test is carried out with current only. After 4 load cycles only moderate temperatures are monitored at the enclosure tube and in the TFB, much lower as expected. Seasonal effects predominate the temperatures of the TFB, the cover layer and the adjacent soil, while the DC GIL generates only marginal increases. Moisture contents and porewater-tensions remain constant apart from some variations caused by rainfalls and vegetation cover. The elongation of the enclosure tube is shorter than 5 mm and the forces are lower than 500 kN. It can be concluded that the DC GIL with a current carrying capacity of 5000 A DC embedded in TFB shows temperature-rises far below the technical GIL limits after 4 load cycles. The TFB ensures high and stable heat conductivity and contact forces, thus restraining the GIL movement. The temperature-rises of the natural soil due to GIL heating are comparatively low in comparison to other effects like sun radiation. The TFB shows a good thermal and mechanical performance.}, language = {en} } @inproceedings{LerchNeidhart, author = {Lerch, Maximilian and Neidhart, Thomas}, title = {Messtechnische Ausr{\"u}stung von Betonstopfs{\"a}ulen bei Probebelastungen}, series = {Messen in der Geotechnik 2020, Fachseminar am 20./21. Februar 2020 in Braunschweig}, volume = {110}, booktitle = {Messen in der Geotechnik 2020, Fachseminar am 20./21. Februar 2020 in Braunschweig}, editor = {Stahlmann, Joachim and Hinzmann, Nils and Stein, Philipp and Gattermann, J{\"o}rg}, publisher = {Selbstverlag}, address = {Braunschweig}, isbn = {978-3-948141-02-8}, doi = {10.24355/dbbs.084-201912181435-0}, pages = {275 -- 296}, abstract = {Die Ausr{\"u}stung vollverdr{\"a}ngter pfahlartiger Elemente - bei Keller Betonstopfs{\"a}ulen (BSS) genannt - mit Messtechnik ist w{\"a}hrend der Herstellung wegen des Einsatzes schwerer R{\"u}tteltechnik und fehlender Stahlbewehrung praktisch unm{\"o}glich. In Zusammenarbeit von Keller und der Fakult{\"a}t Bauingenieurwesen der Ostbayerischen Technischen Hochschule Regensburg wurde ein Verfahren zur nachtr{\"a}glichen Installation der Messtechnik entwickelt, das axiale Dehnungsmessungen in den BSS w{\"a}hrend der Probebelastungen erm{\"o}glicht. Die Ausr{\"u}stung besteht u. a. aus faseroptischen Komponenten. Das Verfahren wurde in situ an 1:1 Versuchen auf einem Testfeld sowohl bei statischen als auch dynamischen Probebelastungen umgesetzt. Es wurden zwei unterschiedliche Messtechniken gem{\"a}ß der jeweiligen Art der Probebelastungen eingesetzt. Daneben wurden robuste Piezometer in den Boden eingebracht, die kontinuierliche Porenwasserdruckmessungen nahe der S{\"a}ulen erm{\"o}glichen. Zweck der verwendeten Messtechnik war es vor allem belastbarere Ergebnisse f{\"u}r effektive Bemessungen der Stopfs{\"a}ulen zu liefern.}, language = {de} }