@inproceedings{SerbunPorshynMuelleretal., author = {Serbun, Pavel and Porshyn, Vitali and M{\"u}ller, G{\"u}nter and Mingels, Stephan and L{\"u}tzenkirchen-Hecht, Dirk and Bachmann, Michael and D{\"u}sberg, Felix and Dams, Florian and Hofmann, Martin and Pahlke, Andreas and Prommesberger, Christian and Langer, Christoph and Ławrowski, Robert Damian and Schreiner, Rupert}, title = {Field emission behavior of Au-tip-coated p-type Si pillar structures}, series = {29th International Vacuum Nanoelectronics Conference (IVNC), 2016, 11-15 July, Vancouver, BC, Canada}, booktitle = {29th International Vacuum Nanoelectronics Conference (IVNC), 2016, 11-15 July, Vancouver, BC, Canada}, publisher = {IEEE}, issn = {2380-6311}, doi = {10.1109/IVNC.2016.7551516}, pages = {181 -- 182}, abstract = {Precisely aligned high-aspect-ratio (HAR) silicon tip arrays were fabricated using enhanced reactive ion etching with an inductively-coupled-plasma followed by a sharpening oxidation. A gold thin film was then sputtered only on the tips of the HAR structures. Field-emission (FE) properties from Au-coated HAR p-Si tip array cathodes have been systematically investigated by means of field emission scanning microscopy (FESM). A rather high efficiency of the HAR Si structures (71\% at 550 V), but limited homogeneous FE with currents of 1-600 nA might be correlated with the varying geometry of the tips and the presence of oxides. I-V measurements of single Au-coated HAR emitters revealed activation effects and the saturation current region at 3 nA. An increase of the saturation current by 4 orders of magnitude was observed during 20 hours of conditioning at constant voltage, which finally resulted in nearly reproducible FN curves with a ß-factor of 473. An excellent stability of the emission current of less than 1 \% was obtained during the additional long-time conditioning at constant voltage. Optical switching under halogen lamp illumination resulted in at least 2 times higher saturation currents and showed a linear dependence of the FE current on the light color temperature.}, language = {en} } @inproceedings{SchreinerLangerPrommesbergeretal., author = {Schreiner, Rupert and Langer, Christoph and Prommesberger, Christian and Ławrowski, Robert Damian and Dams, Florian and Bachmann, Michael and D{\"u}sberg, F. and Hofmann, Martin and Pahlke, Andreas and Serbun, Pavel and Mingels, Stephan and M{\"u}ller, G{\"u}nter}, title = {Semiconductor field emission electron sources using a modular system concept for application in sensors and x-ray-sources}, series = {2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China}, booktitle = {2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China}, publisher = {IEEE}, doi = {10.1109/IVNC.2015.7225572}, pages = {178 -- 179}, abstract = {Semiconductor field emitters are suitable candidates for applications, which require a very stable field emission (FE) current and a high emission uniformity over the entire emission area. By using different materials and geometries, we are able to vary the FE characteristics within a wide range. Each specific application requires its own optimized design for the cathode as well as for the other parts of the FE electron source. To meet as many of these requirements as possible while using only a limited number of different prefabricated components, we established a modular system concept for our FE electron source. This allows the implementation of almost every cathode material. For first characterizations, we used gated p-type Si cathodes with 16 tips. We obtained stable FE currents of 0.4 μA for a grid-potential of 400 V and a gate potential of 100 V. Almost 100\% of the electrons are emitted towards the grid-electrode. Parasitic leakage paths, as well as the electron emission towards the gate-electrode can be neglected. Approximately 10\% of the electrons are transmitted through the grid and reach the external anode. This is in good agreement with the optical transmission through the grid-mesh.}, language = {en} } @article{SteigerFoltanPhilippetal., author = {Steiger, Tamara and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Gruber, Michael and Bredthauer, Andre and Krenkel, Lars and Birkenmaier, Clemens and Lehle, Karla}, title = {Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients?}, series = {Artificial Organs}, volume = {43}, journal = {Artificial Organs}, number = {11}, publisher = {Wiley}, address = {Hoboken}, issn = {1525-1594}, doi = {10.1111/aor.13513}, pages = {1065 -- 1076}, abstract = {Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots-in particular, the presence of von Willebrand factor (vWF)-may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4 ',6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.}, language = {en} } @unpublished{PangerlMoserMuelleretal., author = {Pangerl, Jonas and Moser, Elisabeth and M{\"u}ller, Max and Weigl, Stefan and Jobst, Simon and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A Highly Sensitive Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor: Characterization and Multi-Component Spectra Recording in Synthetic Breath}, series = {SSRN Electronic Journal}, journal = {SSRN Electronic Journal}, publisher = {Elsevier}, doi = {10.2139/ssrn.4305376}, abstract = {Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8260 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbV in terms of ethanol and 250 pptV regarding acetone, our system is among the best performing presented so far.}, language = {en} } @article{HausFoltanPhilippetal., author = {Haus, Moritz and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Lingel, Maximilian P. and Krenkel, Lars and Gruber, Michael and Lehle, Karla}, title = {Neutrophil extracellular traps -a potential trigger for the development of thrombocytopenia during extracorporeal membrane oxygenation}, volume = {15}, publisher = {frontiers}, doi = {10.3389/fimmu.2024.1339235}, abstract = {Neutrophil extracellular traps (NETs) have recently emerged as a potential link between inflammation, immunity, and thrombosis, as well as other coagulation disorders which present a major challenge in the context of extracorporeal membrane oxygenation (ECMO). By examining blood from ECMO patients for NETs and their precursors and correlating them with clinical and laboratory biomarkers of coagulation and inflammation, this study aims to evaluate the association between the presence of NETs in the bloodstream of ECMO patients and the development of potentially severe coagulation disorders during ECMO therapy. Therefore, blood samples were collected from healthy volunteers (n=13) and patients receiving veno-venous (VV) ECMO therapy (n=10). To identify NETs and their precursors, DNA and myeloperoxidase as well as granulocyte marker CD66b were visualized simultaneously by immunofluorescence staining in serial blood smears. Differentiation of DNA-containing objects and identification of NETs and their precursors was performed semiautomatically by a specific algorithm using the shape and size of DNA staining and the intensity of MPO and CD66b signal. Neutrophil extracellular traps and their precursors could be detected in blood smears from patients requiring VV ECMO. Compared to volunteers, ECMO patients presented significantly higher rates of NETs and NET precursors as well as an increased proportion of neutrophil granulocytes in all detected nucleated cells. A high NET rate prior to the initiation of ECMO therapy was associated with both increased iL-6 and TNF-α levels as an expression of a high cytokine burden. These patients with increased NET release also presented an earlier and significantly more pronounced decrease in platelet counts and ATIII activity following initiation of therapy compared with patients with less elevated NETs. These findings provide further indications for the development of immune-mediated acquired thrombocytopenia in ECMO patients.}, language = {en} } @article{KleinNabbefeldHattabetal., author = {Klein, C. and Nabbefeld, T. and Hattab, H. and Meyer, D. and Jnawali, G. and Kammler, Martin and Meyer zu Heringdorf, Frank-Joachim and Golla-Franz, A. and M{\"u}ller, B. H. and Schmidt, Thomas and Henzler, M. and Horn-von Hoegen, Michael}, title = {Lost in reciprocal space? Determination of the scattering condition in spot profile analysis low-energy electron diffraction}, series = {Review of scientific instruments}, volume = {82}, journal = {Review of scientific instruments}, number = {3}, publisher = {American Institute of Physics}, doi = {10.1063/1.3554305}, abstract = {The precise knowledge of the diffraction condition, i.e., the angle of incidence and electron energy, is crucial for the study of surface morphology through spot profile analysis low-energy electron diffraction (LEED). We demonstrate four different procedures to determine the diffraction condition: employing the distortion of the LEED pattern under large angles of incidence, the layer-by-layer growth oscillations during homoepitaxial growth, a G(S) analysis of a rough surface, and the intersection of facet rods with 3D Bragg conditions.}, language = {en} } @article{LehlePhilippKrenkeletal., author = {Lehle, Karla and Philipp, Alois and Krenkel, Lars and Gruber, Michael and Hiller, Karl-Anton and M{\"u}ller, Thomas and Lubnow, Matthias}, title = {Thrombocytopenia During Venovenous Extracorporeal Membrane Oxygenation in Adult Patients With Bacterial, Viral, and COVID-19 Pneumonia}, series = {ASAIO Journal}, journal = {ASAIO Journal}, publisher = {Wolters Kluwer}, issn = {1058-2916}, doi = {10.1097/MAT.0000000000002383}, abstract = {Contact of blood with artificial surfaces triggers platelet activation. The aim was to compare platelet kinetics after venovenous extracorporeal membrane oxygenation (V-V ECMO) start and after system exchange in different etiologies of acute lung failure. Platelet counts and coagulation parameters were analyzed from adult patients with long and exchange-free (≥8 days) ECMO runs (n = 330) caused by bacterial (n = 142), viral (n = 76), or coronavirus disease 2019 (COVID-19) (n = 112) pneumonia. A subpopulation requiring a system exchange and with long, exchange-free runs of the second oxygenator (≥7 days) (n = 110) was analyzed analogously. Patients with COVID-19 showed the highest platelet levels before ECMO implantation. Independent of the underlying disease and ECMO type, platelet counts decreased significantly within 24 hours and reached a steady state after 5 days. In the subpopulation, at the day of a system exchange, platelet counts were lower compared with ECMO start, but without differences between underlying diseases. Subsequently, platelets remained unchanged in the bacterial pneumonia group, but increased in the COVID-19 and viral pneumonia groups within 2-4 days, whereas D-dimers decreased and fibrinogen levels increased. Thus, overall platelet counts on V-V ECMO show disease-specific initial dynamics followed by an ongoing consumption by the ECMO device, which is not boosted by new artificial surfaces after a system exchange.}, language = {en} }