@techreport{BackesBalkeBenerjeeetal., type = {Working Paper}, author = {Backes, Judith and Balke, Maurice and Benerjee, Marc and Beitzel, Knut and B{\"o}hm, Elisabeth and Brandt, Hanna and Brunner, Ulrich and B{\"u}ttner, Carl Christopher and Dyrna, Felix and Grossmann, Irmgard and G{\"u}hring, Thorsten and H{\"u}nnebeck, Sophia and K{\"a}hler, Michael and Kl{\"o}ckner, Nicole and Kopkow, Christian and Lehmann, Lars and Martetschl{\"a}ger, Frank and Mauch, Frieder and Michalk, Katrin and M{\"u}ller, Maike and M{\"u}ller-Rath, Ralf and Nolte, Philip and Pfingsten, Andrea and Prill, Robert and Schnetzke, Marc and Seckler, Martina}, title = {Subacromiales Impingment}, edition = {1. Aufl./Version 1.0 (02.05.2021)}, organization = {Deutsche Vereinigung f{\"u}r Schulter- und Ellbogenchirurgie e.V. und Deutsche Gesellschaft f{\"u}r Orthop{\"a}die und Orthop{\"a}dische Chirurgie, e.V.}, pages = {47}, language = {de} } @unpublished{MuellerWeiglMuellerWilliamsetal., author = {M{\"u}ller, Max and Weigl, Stefan and M{\"u}ller-Williams, Jennifer and Lindauer, Matthias and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Ambient methane monitoring at Hohenpeißenberg utilizing photoacoustic spectroscopy and cavity ring down spectroscopy}, doi = {10.5194/egusphere-2023-1010}, abstract = {With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10-9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 \% from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.}, language = {en} } @article{MuellerWeiglMuellerWilliamsetal., author = {M{\"u}ller, Max and Weigl, Stefan and M{\"u}ller-Williams, Jennifer and Lindauer, Matthias and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Comparison of photoacoustic spectroscopy and cavity ring-down spectroscopy for ambient methane monitoring at Hohenpeißenberg}, series = {Atmospheric Measurement Techniques}, volume = {16}, journal = {Atmospheric Measurement Techniques}, number = {18}, publisher = {Copernicus Publications}, issn = {1867-8548}, doi = {10.5194/amt-16-4263-2023}, pages = {4263 -- 4270}, abstract = {With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10-9), methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a 5 d period at Hohenpeißenberg, Germany. As a reference device, a calibrated cavity ring-down spectrometer, Picarro G2301, from the meteorological observatory of the German Weather Service (DWD) was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to fluctuating environmental conditions, e.g. ambient humidity. The obtained results show that for PA sensor systems non-radiative relaxation effects induced by varying humidity are a non-negligible factor. Applying algorithm compensation techniques, which are capable of calculating the influence of non-radiative relaxation effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 \% from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.}, language = {en} } @article{BachmannDamsDuesbergetal., author = {Bachmann, Michael and Dams, Florian and D{\"u}sberg, Felix and Hofmann, Martin and Pahlke, Andreas and Langer, Christoph and Ławrowski, Robert Damian and Prommesberger, Christian and Schreiner, Rupert and Serbun, Pavel and L{\"u}tzenkirchen-Hecht, Dirk and M{\"u}ller, G{\"u}nter}, title = {Extraction of the characteristics of current-limiting elements from field emission measurement data}, series = {Journal of Vacuum Science \& Technology B}, volume = {35}, journal = {Journal of Vacuum Science \& Technology B}, number = {2}, doi = {10.1116/1.4971768}, abstract = {In this contribution, the authors will present an algorithm to extract the characteristics of nonideal field emission circuit elements from saturation-limited field emission measurement data. The method for calculating the voltage drop on current-limiting circuit elements is based on circuit theory as well as Newton's method. Since the only assumption the authors make on the current-limiting circuit is a connection in series, this method is applicable to most field emission data showing saturation. To be able to determine the significance of any parameter output, the uncertainties of data and extracted parameters as well as the parameter correlations are fully taken into account throughout the algorithm. N-type silicon samples with varying external serial resistors are analyzed. All results show a good agreement to the nominal resistor values. Additionally, several p-type samples are analyzed, showing a diodelike behavior. The extracted current-limiting characteristics of the p-type samples are in good agreement with a pn-junction model. The stability of the emission current of the p-type samples is measured by constant voltage measurements and compared to the extracted current-limiting characteristics. The application of the algorithm to measurement data shows that the given algorithm is a valuable tool to analyze field emission measurement data influenced by nonemissive processes.}, language = {en} } @inproceedings{LangerŁawrowskiPrommesbergeretal., author = {Langer, Christoph and Ławrowski, Robert Damian and Prommesberger, Christian and Dams, Florian and Serbun, Pavel and Bachmann, Michael and M{\"u}ller, G{\"u}nter and Schreiner, Rupert}, title = {High aspect ratio silicon tip cathodes for application in field emission electron sources}, series = {2014 27th International Vacuum Nanoelectronics Conference (IVNC), 6-10 July 2014, Engelberg, Switzerland}, booktitle = {2014 27th International Vacuum Nanoelectronics Conference (IVNC), 6-10 July 2014, Engelberg, Switzerland}, publisher = {IEEE}, doi = {10.1109/IVNC.2014.6894824}, pages = {222 -- 223}, abstract = {Precisely aligned arrays of sharp tip structures on top of elongated pillars were realized by using an improved fabrication process including an additional inductively-coupled-plasma reactive-ion etching step. Arrays of n-type and p-type silicon with 271 tips have been fabricated and investigated. Those structures have a total height of 5-6 µm and apex radii less than 20nm. Integral field emission measurements of the arrays yielded low onset-fields in the range of 8-12V=µm and field enhancement factors between 300 and 700. The I-E curves of n-type structures showed the usual Fowler-Nordheim behaviour, whereas p-type structures revealed a significant saturation region due to the limited number of electrons in the conduction band and a further carrier depletion effect caused by the pillar. The maximum integral current in the saturation region was 150 nA at fields above 30V=µm. An excellent stability of the emission current of less than ± 2\% fluctuation was observed in the saturation region. For n-type Si a maximum integral current of 10 µA at 24V=µm and an average current stability with a fluctuation of ± 50\% were measured.}, language = {en} } @article{EnglertAngeleFierlbecketal., author = {Englert, Carsten and Angele, Peter and Fierlbeck, J. and Dendorfer, Sebastian and Schubert, T. and M{\"u}ller, R. and Lienhard, S. and Zellner, J. and Nerlich, Michael and Neumann, Carsten}, title = {Conductive bone substitute material with variable antibiotic delivery}, series = {Der Unfallchirurg}, volume = {110}, journal = {Der Unfallchirurg}, number = {5}, publisher = {Springer}, doi = {10.1007/s00113-007-1229-3}, pages = {408 -- 413}, abstract = {A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis.}, subject = {Knochenersatz}, language = {en} } @inproceedings{SchreinerLangerPrommesbergeretal., author = {Schreiner, Rupert and Langer, Christoph and Prommesberger, Christian and Ławrowski, Robert Damian and Dams, Florian and Bachmann, Michael and D{\"u}sberg, F. and Hofmann, M. and Pahlke, A. and Serbun, Pavel and Mingels, S. and M{\"u}ller, G{\"u}nter}, title = {Semiconductor field emission electron sources using a modular system concept for application in sensors and x-ray-sources}, series = {2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China}, booktitle = {2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China}, publisher = {IEEE}, doi = {10.1109/IVNC.2015.7225572}, pages = {178 -- 179}, abstract = {Semiconductor field emitters are suitable candidates for applications, which require a very stable field emission (FE) current and a high emission uniformity over the entire emission area. By using different materials and geometries, we are able to vary the FE characteristics within a wide range. Each specific application requires its own optimized design for the cathode as well as for the other parts of the FE electron source. To meet as many of these requirements as possible while using only a limited number of different prefabricated components, we established a modular system concept for our FE electron source. This allows the implementation of almost every cathode material. For first characterizations, we used gated p-type Si cathodes with 16 tips. We obtained stable FE currents of 0.4 μA for a grid-potential of 400 V and a gate potential of 100 V. Almost 100\% of the electrons are emitted towards the grid-electrode. Parasitic leakage paths, as well as the electron emission towards the gate-electrode can be neglected. Approximately 10\% of the electrons are transmitted through the grid and reach the external anode. This is in good agreement with the optical transmission through the grid-mesh.}, language = {en} } @article{KleinNabbefeldHattabetal., author = {Klein, C. and Nabbefeld, T. and Hattab, H. and Meyer, D. and Jnawali, G. and Kammler, Martin and Meyer zu Heringdorf, Frank-Joachim and Golla-Franz, A. and M{\"u}ller, B. H. and Schmidt, Th and Henzler, M. and Horn-von Hoegen, Michael}, title = {Lost in reciprocal space? Determination of the scattering condition in spot profile analysis low-energy electron diffraction}, series = {Review of scientific instruments}, volume = {82}, journal = {Review of scientific instruments}, number = {3}, publisher = {American Institute of Physics}, doi = {10.1063/1.3554305}, abstract = {The precise knowledge of the diffraction condition, i.e., the angle of incidence and electron energy, is crucial for the study of surface morphology through spot profile analysis low-energy electron diffraction (LEED). We demonstrate four different procedures to determine the diffraction condition: employing the distortion of the LEED pattern under large angles of incidence, the layer-by-layer growth oscillations during homoepitaxial growth, a G(S) analysis of a rough surface, and the intersection of facet rods with 3D Bragg conditions.}, language = {en} } @article{PfeiferMuellerPrantletal., author = {Pfeifer, Christian and M{\"u}ller, Michael and Prantl, Lukas and Berner, Arne and Dendorfer, Sebastian and Englert, Carsten}, title = {Cartilage labelling for mechanical testing in T-peel configuration}, series = {International Orthopaedics}, volume = {36}, journal = {International Orthopaedics}, number = {7}, publisher = {Springer}, doi = {10.1007/s00264-011-1468-3}, pages = {1493 -- 1499}, abstract = {PURPOSE: The purpose of this study was to find a suitable method of labelling cartilage samples for the measurement of distraction distances in biomechanical testing. METHODS: Samples of bovine cartilage were labelled using five different methods: hydroquinone and silver nitrate (AgNO3), potassium permanganate (KMnO4) with sodium thiosulphate (Na2S2O3), India ink, heat, and laser energy. After the labelling, we analysed the cartilage samples with regard to cytotoxity by histochemical staining with ethidiumbromide homodimer (EthD-1) and calcein AM. Furthermore, we tested cartilages labelled with India ink and heat in a T-peel test configuration to analyse possible changes in the mechanical behaviour between marked and unlabelled samples. RESULTS: Only the labelling methods with Indian ink or a heated needle showed acceptable results in the cytotoxity test with regard to labelling persistence, accuracy, and the influence on consistency and viability of the chondrocytes. In the biomechanical T-peel configuration, heat-labelled samples collapsed significantly earlier than unlabelled samples. CONCLUSION: Labelling bovine cartilage samples with Indian ink in biomechanical testing is a reliable, accurate, inexpensive, and easy-to-perform method. This labelling method influenced neither the biomechanical behaviour nor the viability of the tissue compared to untreated bovine cartilage.}, subject = {Knorpel}, language = {en} } @inproceedings{PangerlWittmannWeigletal., author = {Pangerl, Jonas and Wittmann, Elisabeth and Weigl, Stefan and M{\"u}ller, Max and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Using a Modulated Quantum Cascade Laser for Photoacoustic Spectra Recording of Exhaled Acetone and Main Breath Components}, series = {Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES)}, booktitle = {Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES)}, publisher = {Optica Publishing Group}, doi = {10.1364/AIS.2022.ATu3G.1}, abstract = {Photoacoustic spectra of main breath components together with acetone are presented demonstrating spectral linearity towards different concentrations and compositions. The acetone 3σ detection limit at 1209 cm-1 is 0.28 ppbV}, language = {en} }