@inproceedings{SchreinerLangerPrommesbergeretal., author = {Schreiner, Rupert and Langer, Christoph and Prommesberger, Christian and Ławrowski, Robert Damian and Dams, Florian and Bachmann, Michael and D{\"u}sberg, F. and Hofmann, Martin and Pahlke, Andreas and Serbun, Pavel and Mingels, Stephan and M{\"u}ller, G{\"u}nter}, title = {Semiconductor field emission electron sources using a modular system concept for application in sensors and x-ray-sources}, series = {2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China}, booktitle = {2015 28th International Vacuum Nanoelectronics Conference (IVNC), 13-17 July 2015, Guangzhou, China}, publisher = {IEEE}, doi = {10.1109/IVNC.2015.7225572}, pages = {178 -- 179}, abstract = {Semiconductor field emitters are suitable candidates for applications, which require a very stable field emission (FE) current and a high emission uniformity over the entire emission area. By using different materials and geometries, we are able to vary the FE characteristics within a wide range. Each specific application requires its own optimized design for the cathode as well as for the other parts of the FE electron source. To meet as many of these requirements as possible while using only a limited number of different prefabricated components, we established a modular system concept for our FE electron source. This allows the implementation of almost every cathode material. For first characterizations, we used gated p-type Si cathodes with 16 tips. We obtained stable FE currents of 0.4 μA for a grid-potential of 400 V and a gate potential of 100 V. Almost 100\% of the electrons are emitted towards the grid-electrode. Parasitic leakage paths, as well as the electron emission towards the gate-electrode can be neglected. Approximately 10\% of the electrons are transmitted through the grid and reach the external anode. This is in good agreement with the optical transmission through the grid-mesh.}, language = {en} } @article{KnoedlerBaecherKaukeNavarroetal., author = {Kn{\"o}dler, Leonard and Baecher, Helena and Kauke-Navarro, Martin and Prantl, Lukas and Machens, Hans-G{\"u}nther and Scheuermann, Philipp and Palm, Christoph and Baumann, Raphael and Kehrer, Andreas and Panayi, Adriana C. and Knoedler, Samuel}, title = {Towards a Reliable and Rapid Automated Grading System in Facial Palsy Patients: Facial Palsy Surgery Meets Computer Science}, series = {Journal of Clinical Medicine}, volume = {11}, journal = {Journal of Clinical Medicine}, number = {17}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/jcm11174998}, abstract = {Background: Reliable, time- and cost-effective, and clinician-friendly diagnostic tools are cornerstones in facial palsy (FP) patient management. Different automated FP grading systems have been developed but revealed persisting downsides such as insufficient accuracy and cost-intensive hardware. We aimed to overcome these barriers and programmed an automated grading system for FP patients utilizing the House and Brackmann scale (HBS). Methods: Image datasets of 86 patients seen at the Department of Plastic, Hand, and Reconstructive Surgery at the University Hospital Regensburg, Germany, between June 2017 and May 2021, were used to train the neural network and evaluate its accuracy. Nine facial poses per patient were analyzed by the algorithm. Results: The algorithm showed an accuracy of 100\%. Oversampling did not result in altered outcomes, while the direct form displayed superior accuracy levels when compared to the modular classification form (n = 86; 100\% vs. 99\%). The Early Fusion technique was linked to improved accuracy outcomes in comparison to the Late Fusion and sequential method (n = 86; 100\% vs. 96\% vs. 97\%). Conclusions: Our automated FP grading system combines high-level accuracy with cost- and time-effectiveness. Our algorithm may accelerate the grading process in FP patients and facilitate the FP surgeon's workflow.}, language = {en} } @article{MatuschDepboyluPalmetal., author = {Matusch, Andreas and Depboylu, Candan and Palm, Christoph and Wu, Bei and H{\"o}glinger, G{\"u}nter U. and Sch{\"a}fer, Martin K.-H. and Becker, Johanna Sabine}, title = {Cerebral bio-imaging of Cu, Fe, Zn and Mn in the MPTP mouse model of Parkinsons disease using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)}, series = {Journal of the American Society for Mass Spectrometry}, volume = {21}, journal = {Journal of the American Society for Mass Spectrometry}, number = {1}, doi = {10.1016/j.jasms.2009.09.022}, pages = {161 -- 171}, abstract = {Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a powerful technique for the determination of metal and nonmetal distributions within biological systems with high sensitivity. An imaging LA-ICP-MS technique for Fe, Cu, Zn, and Mn was developed to produce large series of quantitative element maps in native brain sections of mice subchronically intoxicated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridin (MPTP) as a model of Parkinson's disease. Images were calibrated using matrix-matched laboratory standards. A software solution allowing a precise delineation of anatomical structures was implemented. Coronal brain sections were analyzed crossing the striatum and the substantia nigra, respectively. Animals sacrificed 2 h, 7 d, or 28 d after the last MPTP injection and controls were investigated. We observed significant decreases of Cu concentrations in the periventricular zone and the fascia dentata at 2 h and 7d and a recovery or overcompensation at 28 d, most pronounced in the rostral periventricular zone (+40\%). In the cortex Cu decreased slightly to -10\%. Fe increased in the interpeduncular nucleus (+40\%) but not in the substantia nigra. This pattern is in line with a differential regulation of periventricular and parenchymal Cu, and with the histochemical localization of Fe, and congruent to regions of preferential MPTP binding described in the rodent brain. The LA-ICP-MS technique yielded valid and statistically robust results in the present study on 39 slices from 19 animals. Our findings underline the value of routine micro-local analytical techniques in the life sciences and affirm a role of Cu availability in Parkinson's disease.}, subject = {ICP-Massenspektrometrie}, language = {en} } @inproceedings{SchubertPietrzykReisseletal., author = {Schubert, Nicole and Pietrzyk, Uwe and Reißel, Martin and Palm, Christoph}, title = {Reduktion von Rissartefakten durch nicht-lineare Registrierung in histologischen Schnittbildern}, series = {Bildverarbeitung f{\"u}r die Medizin 2009; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2009; Algorithmen - Systeme - Anwendungen; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, publisher = {Springer}, address = {Berlin}, pages = {410 -- 414}, abstract = {In dieser Arbeit wird ein Verfahren vorgestellt, das Rissartefakte, die in histologischen Rattenhirnschnitten vorkommen k{\"o}nnen, durch nicht-lineare Registrierung reduziert. Um die Optimierung in der Rissregion zu leiten, wird der Curvature Registrierungsansatz um eine Metrik basierend auf der Segmentierung der Bilder erweitert. Dabei erzielten Registrierungen mit der ausschließlichen Segmentierung des Risses bessere Ergebnisse als Registrierungen mit einer Segmentierung des gesamten Hirnschnitts. Insgesamt zeigt sich eine deutliche Verbesserung in der Rissregion, wobei der verbleibende reduzierte Riss auf die Glattheitsbedingungen des Regularisierers zur{\"u}ckzuf{\"u}hren ist.}, subject = {Registrierung }, language = {de} } @article{IlgnerPalmSchuetzetal., author = {Ilgner, Justus F. R. and Palm, Christoph and Sch{\"u}tz, Andreas G. and Spitzer, Klaus and Westhofen, Martin and Lehmann, Thomas M.}, title = {Colour Texture Analysis for Quantitative Laryngoscopy}, series = {Acta Otolaryngologica}, volume = {123}, journal = {Acta Otolaryngologica}, doi = {10.1080/00016480310000412}, pages = {730 -- 734}, abstract = {Whilst considerable progress has been made in enhancing the quality of indirect laryngoscopy and image processing, the evaluation of clinical findings is still based on the clinician's judgement. The aim of this paper was to examine the feasibility of an objective computer-based method for evaluating laryngeal disease. Digitally recorded images obtained by 90 degree- and 70 degree-angled indirect rod laryngoscopy using standardized white balance values were made of 16 patients and 19 healthy subjects. The digital images were evaluated manually by the clinician based on a standardized questionnaire, and suspect lesions were marked and classified on the image. Following colour separation, normal vocal cord areas as well as suspect lesions were analyzed automatically using co-occurrence matrices, which compare colour differences between neighbouring pixels over a predefined distance. Whilst colour histograms did not provide sufficient information for distinguishing between healthy and diseased tissues, consideration of the blue content of neighbouring pixels enabled a correct classification in 81.4\% of cases. If all colour channels (red, green and blue) were regarded simultaneously, the best classification correctness obtained was 77.1\%. Although only a very basic classification differentiating between healthy and diseased tissue was attempted, the results showed progress compared to grey-scale histograms, which have been evaluated before. The results document a first step towards an objective, machine-based classification of laryngeal images, which could provide the basis for further development of an expert system for use in indirect laryngoscopy.}, language = {en} } @inproceedings{WeihererZornWittenbergetal., author = {Weiherer, Maximilian and Zorn, Martin and Wittenberg, Thomas and Palm, Christoph}, title = {Retrospective Color Shading Correction for Endoscopic Images}, series = {Bildverarbeitung f{\"u}r die Medizin 2020. Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 15. bis 17. M{\"a}rz 2020 in Berlin}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2020. Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 15. bis 17. M{\"a}rz 2020 in Berlin}, editor = {Tolxdorff, Thomas and Deserno, Thomas M. and Handels, Heinz and Maier, Andreas and Maier-Hein, Klaus H. and Palm, Christoph}, publisher = {Springer Vieweg}, address = {Wiesbaden}, isbn = {978-3-658-29266-9}, doi = {10.1007/978-3-658-29267-6}, pages = {14 -- 19}, abstract = {In this paper, we address the problem of retrospective color shading correction. An extension of the established gray-level shading correction algorithm based on signal envelope (SE) estimation to color images is developed using principal color components. Compared to the probably most general shading correction algorithm based on entropy minimization, SE estimation does not need any computationally expensive optimization and thus can be implemented more effciently. We tested our new shading correction scheme on artificial as well as real endoscopic images and observed promising results. Additionally, an indepth analysis of the stop criterion used in the SE estimation algorithm is provided leading to the conclusion that a fixed, user-defined threshold is generally not feasible. Thus, we present new ideas how to develop a non-parametric version of the SE estimation algorithm using entropy.}, subject = {Endoskopie}, language = {en} } @inproceedings{HassanIlgnerPalmetal., author = {Hassan, H. and Ilgner, Justus F. R. and Palm, Christoph and Lehmann, Thomas M. and Spitzer, Klaus and Westhofen, Martin}, title = {Objective Judgement of Endoscopic Laryngeal Images}, series = {Advances in Quantitative Laryngoscopy, Voice and Speech Research, Proceedings of the 3rd International Workshop, RWTH Aachen}, booktitle = {Advances in Quantitative Laryngoscopy, Voice and Speech Research, Proceedings of the 3rd International Workshop, RWTH Aachen}, editor = {Lehmann, Thomas M. and Spitzer, Klaus and Tolxdorff, Thomas}, pages = {135 -- 142}, abstract = {Video Documentation of endoscopic findings simplifies diagnostic counseling of the patient and aids pre-operative discussion among the medical team. Judgment of such images is still subjective and can not give a quantitative evaluation of the disease process regarding diagnosis or response to treatment. Modern treatment of early laryngeal cancer with laserablation requires intensive follow up and frequent direct laryngoscopy under general anesthesia with blind biopsies to detect any tumor residual or recurrence. Inflammatory conditions of the larynx are frequently confused with other causes of dysphonia. Mapping anddigital analysis of the documented image will suggest the tumor site and avoids undue blind biopsies under anesthesia. However, varying illumination results in different colors reflected from the same object. To achieve quantitative analysis, color constancy has to be assured. Inthis paper, the environment is presented which allow the objective judgment of larngoscopies.}, language = {en} } @article{HuttererHattingenPalmetal., author = {Hutterer, Markus and Hattingen, Elke and Palm, Christoph and Proescholdt, Martin Andreas and Hau, Peter}, title = {Current standards and new concepts in MRI and PET response assessment of antiangiogenic therapies in high-grade glioma patients}, series = {Neuro-Oncology}, volume = {17}, journal = {Neuro-Oncology}, number = {6}, doi = {10.1093/neuonc/nou322}, pages = {784 -- 800}, abstract = {Despite multimodal treatment, the prognosis of high-grade gliomas is grim. As tumor growth is critically dependent on new blood vessel formation, antiangiogenic treatment approaches offer an innovative treatment strategy. Bevacizumab, a humanized monoclonal antibody, has been in the spotlight of antiangiogenic approaches for several years. Currently, MRI including contrast-enhanced T1-weighted and T2/fluid-attenuated inversion recovery (FLAIR) images is routinely used to evaluate antiangiogenic treatment response (Response Assessment in Neuro-Oncology criteria). However, by restoring the blood-brain barrier, bevacizumab may reduce T1 contrast enhancement and T2/FLAIR hyperintensity, thereby obscuring the imaging-based detection of progression. The aim of this review is to highlight the recent role of imaging biomarkers from MR and PET imaging on measurement of disease progression and treatment effectiveness in antiangiogenic therapies. Based on the reviewed studies, multimodal imaging combining standard MRI with new physiological MRI techniques and metabolic PET imaging, in particular amino acid tracers, may have the ability to detect antiangiogenic drug susceptibility or resistance prior to morphological changes. As advances occur in the development of therapies that target specific biochemical or molecular pathways and alter tumor physiology in potentially predictable ways, the validation of physiological and metabolic imaging biomarkers will become increasingly important in the near future.}, subject = {Gliom}, language = {en} } @inproceedings{FranzDreherPrinzenetal., author = {Franz, Daniela and Dreher, Maria and Prinzen, Martin and Teßmann, Matthias and Palm, Christoph and Katzky, Uwe and Perret, Jerome and Hofer, Mathias and Wittenberg, Thomas}, title = {CT-basiertes virtuelles Fr{\"a}sen am Felsenbein}, series = {Bildverarbeitung f{\"u}r die Medizin 2018; Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 11. bis 13. M{\"a}rz 2018 in Erlangen}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2018; Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 11. bis 13. M{\"a}rz 2018 in Erlangen}, publisher = {Springer}, address = {Berlin}, isbn = {978-3-662-56537-7}, doi = {10.1007/978-3-662-56537-7_51}, pages = {176 -- 181}, abstract = {Im Rahmen der Entwicklung eines haptisch-visuellen Trainingssystems f{\"u}r das Fr{\"a}sen am Felsenbein werden ein Haptikarm und ein autostereoskopischer 3D-Monitor genutzt, um Chirurgen die virtuelle Manipulation von kn{\"o}chernen Strukturen im Kontext eines sog. Serious Game zu erm{\"o}glichen. Unter anderem sollen Assistenz{\"a}rzte im Rahmen ihrer Ausbildung das Fr{\"a}sen am Felsenbein f{\"u}r das chirurgische Einsetzen eines Cochlea-Implantats {\"u}ben k{\"o}nnen. Die Visualisierung des virtuellen Fr{\"a}sens muss daf{\"u}r in Echtzeit und m{\"o}glichst realistisch modelliert, implementiert und evaluiert werden. Wir verwenden verschiedene Raycasting Methoden mit linearer und Nearest Neighbor Interpolation und vergleichen die visuelle Qualit{\"a}t und die Bildwiederholfrequenzen der Methoden. Alle verglichenen Verfahren sind sind echtzeitf{\"a}hig, unterscheiden sich aber in ihrer visuellen Qualit{\"a}t.}, subject = {Felsenbein}, language = {de} } @inproceedings{FranzKatzkyNeumannetal., author = {Franz, Daniela and Katzky, Uwe and Neumann, Sabine and Perret, Jerome and Hofer, Mathias and Huber, Michaela and Schmitt-R{\"u}th, Stephanie and Haug, Sonja and Weber, Karsten and Prinzen, Martin and Palm, Christoph and Wittenberg, Thomas}, title = {Haptisches Lernen f{\"u}r Cochlea Implantationen}, series = {15. Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer- und Roboterassistierte Chirurgie (CURAC2016), Tagungsband, 2016, Bern, 29.09. - 01.10.}, booktitle = {15. Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer- und Roboterassistierte Chirurgie (CURAC2016), Tagungsband, 2016, Bern, 29.09. - 01.10.}, pages = {21 -- 26}, abstract = {Die Implantation eines Cochlea Implantates ben{\"o}tigt einen chirurgischen Zugang im Felsenbein und durch die Paukenh{\"o}hle des Patienten. Der Chirurg hat eine eingeschr{\"a}nkte Sicht im Operationsgebiet, die weiterhin viele Risikostrukturen enth{\"a}lt. Um eine Cochlea Implantation sicher und fehlerfrei durchzuf{\"u}hren, ist eine umfangreiche theoretische und praktische (teilweise berufsbegleitende) Fortbildung sowie langj{\"a}hrige Erfahrung notwendig. Unter Nutzung von realen klinischen CT/MRT Daten von Innen- und Mittelohr und der interaktiven Segmentierung der darin abgebildeten Strukturen (Nerven, Cochlea, Geh{\"o}rkn{\"o}chelchen,...) wird im HaptiVisT Projekt ein haptisch-visuelles Trainingssystem f{\"u}r die Implantation von Innen- und Mittelohr-Implantaten realisiert, das als sog. „Serious Game" mit immersiver Didaktik gestaltet wird. Die Evaluierung des Demonstrators hinsichtlich Zweckm{\"a}ßigkeit erfolgt prozessbegleitend und ergebnisorientiert, um m{\"o}gliche technische oder didaktische Fehler vor Fertigstellung des Systems aufzudecken. Drei zeitlich versetzte Evaluationen fokussieren dabei chirurgisch-fachliche, didaktische sowie haptisch-ergonomische Akzeptanzkriterien.}, subject = {Cochlea-Implantat}, language = {de} } @inproceedings{MaierHaugHuberetal., author = {Maier, Johannes and Haug, Sonja and Huber, Michaela and Katzky, Uwe and Neumann, Sabine and Perret, J{\´e}r{\^o}me and Prinzen, Martin and Weber, Karsten and Wittenberg, Thomas and W{\"o}hl, Rebecca and Scorna, Ulrike and Palm, Christoph}, title = {Development of a haptic and visual assisted training simulation concept for complex bone drilling in minimally invasive hand surgery}, series = {CARS Conference, 5.10.-7.10.2017}, booktitle = {CARS Conference, 5.10.-7.10.2017}, language = {en} } @techreport{VolkenhoffGerstenbergerBreitbarthetal., author = {Volkenhoff, Tobias and Gerstenberger, Marcus and Breitbarth, Lutz and Carstensen, Christian and D{\"o}lger, Reiner and Feldges, Michael and Hegewald, Jessica and Mutzbauer, Johannes and Rose, Martin and Schopf, Hans J{\"u}rgen and Schroth, Max and Schwietering, Christoph and Seidel, Christian and Sievers, Ariane and Spangler, Matthias and Trupat, Stefan and {\"U}st{\"u}n, Ellen}, title = {H NBA - Hinweise zum Einsatz von Netzbeeinflussungsanlagen}, number = {310/1}, edition = {Ausgabe 2025}, publisher = {FGSV}, address = {K{\"o}ln}, isbn = {978-3-86646-434-8}, pages = {94}, language = {de} } @article{WolfgrammAbbSampetal., author = {Wolfgramm, Alex and Abb, Valerius and Samp, Artur and Samp, Rafal and Hoffmann, Jens Christoph and M{\"u}ller, Rainer and Kammler, Martin}, title = {Structural and functional evolution of HKUST-1 nanoparticles induced by ball milling}, series = {Next Materials}, volume = {10}, journal = {Next Materials}, publisher = {Elsevier}, doi = {10.1016/j.nxmate.2025.101544}, pages = {7}, abstract = {In this study, the effect of post-synthetic ball milling on the structural and functional properties of as-synthesized nanoparticles of the copper-based metal-organic framework (MOF) HKUST-1 was investigated for the first time. Nanoparticles were synthesized using sodium formate as a capping agent. The crystalline particles were subjected to a controlled ball milling process, which induced significant structural changes. Powder X-ray diffraction (PXRD) revealed a reduction in crystallite size from 91 nm to 21 nm and the introduction of microstrain, partially disrupting the MOF's long-range crystalline order, as evidenced by peak broadening and the diminished intensity of high-angle reflections. Particle morphology pre- and post-milling was further studied with scanning electron microscopy (SEM) imaging, verifying a narrow particle size distribution of ± 22 nm after milling. Fourier-transform infrared spectroscopy (FTIR) indicated protonation of carboxylate groups in the larger pores of the framework, likely due to moisture incorporation during milling. Brunauer-Emmett-Teller (BET) surface area analysis showed a substantial decrease in specific surface area from 521 m²/g to 226 m²/g, suggesting a partial collapse of the porous framework. We discuss the applicability of ball milling as a versatile means of post-synthetic approach to reduce MOF particle sizes, a key element in the preparation of MOF-based thin films using inks or polymers.}, language = {en} }