@article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {Experimental Investigation of the Adsorption and Desorption Kinetics on an Open-Structured Asymmetric Plate Heat Exchanger; Matching Between Small-Scale and Full-Scale Results}, series = {Frontiers in Energy Research}, volume = {10}, journal = {Frontiers in Energy Research}, publisher = {Frontiers}, doi = {10.3389/fenrg.2022.818486}, pages = {1 -- 15}, abstract = {This paper introduces the results of an experimental study on the adsorption and desorption kinetics of a commercially available, open-structured asymmetric plate heat exchanger adapted to act as an adsorber/desorber for the application in adsorption heat transformation processes. In addition, a volumetric large temperature jump (V-LTJ) kinetic setup was applied to measure the adsorption and desorption kinetics of a small-scale adsorbent sample prepared dedicatedly to be representative for the adsorbent domain inside the investigated adsorber plate heat exchanger (APHE). All kinetic results of the small-scale adsorbent sample and the APHE were fitted into exponential forms with a single characteristic time constant (τ) with a coefficient of determination (R2) better than 0.9531. A very good matching between the small-scale and full-scale adsorption kinetic measurements was obtained, with an average relative deviation of 12.3\% in the obtained τ-values. In addition, the kinetic data of the small-scale adsorbent sample were utilized for estimating the expected specific instantaneous and moving average powers of the evaporator/condenser heat exchanger. The average relative deviation (ARD) between the moving average specific evaporator powers obtained from the small-scale and the full-scale measurements amounts between 5.4 and 15.1\%.}, language = {en} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {On the development of an innovative adsorber plate heat exchanger for adsorption heat transformation processes; an experimental and numerical study}, series = {Energy}, volume = {207}, journal = {Energy}, number = {September}, publisher = {Elsevier}, doi = {10.1016/j.energy.2020.118272}, pages = {1 -- 13}, abstract = {An innovative adsorber plate heat exchanger (APHE), which is developed for application in adsorption heat pumps, chillers and thermal energy storage systems, is introduced. A test frame has been constructed as a representative segment of the introduced APHE for applying loose grains of AQSOA-Z02. Adsorption kinetic measurements have been carried out in a volumetric large-temperature-jump setup under typical operating conditions of adsorption processes. A transient 2-D model is developed for the tested sample inside the setup. The measured temporal uptake variations with time have been fed to the model, through which a micro-pore diffusion coefficient at infinite temperature of 2 E-4 [m2s-1] and an activation energy of 42.1 [kJ mol-1] have been estimated. A 3-D model is developed to simulate the combined heat and mass transfer inside the APHE and implemented in a commercial software. Comparing the obtained results with the literature values for an extruded aluminium adsorber heat exchanger coated with a 500 μm layer of the same adsorbent, the differential water uptake obtained after 300 s of adsorption (8.2 g/100 g) implies a sound enhancement of 310\%. This result proves the great potential of the introduced APHE to remarkably enhance the performance of adsorption heat transformation appliances.}, language = {en} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {On the application of adsorber plate heat exchangers in thermally driven chillers}, series = {Applied Thermal Engineering}, volume = {220}, journal = {Applied Thermal Engineering}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2022.119713}, abstract = {The effect of both heat and mass transfer characteristic lengths (HTCL, MTCL) of two different adsorber plate heat exchangers (APHE), for application in an adsorption chiller, on the adsorption and desorption kinetics is investigated. Three representative test frames (TF1-TF3) are prepared to examine small-scale adsorbent samples of the microporous silica gel (Siogel of Oker-Chemie, Germany) applying the volumetric large-temperature-jump methodology at different operating conditions. Based on the obtained kinetic data, an analytical model has been developed to predict the specific cooling power (SCP) and the coefficient of performance (COP) of a single-bed adsorption chiller comprising the studied APHEs. It turned out that, within the tested range of HTCL and MTCL, it can be concluded that, the adsorption kinetics are mainly influenced by the MTCL, while the desorption kinetics are dominated by the HTCL of the adsorbent domain. Applying Siogel as loose pellets inside a newly introduced APHE results in of 423.3 and 182.7 W⋅kg-1, at the evaporator temperatures of 15 °C and 5 °C, respectively. Herein, the condenser and adsorber-end temperatures amount to 30 °C and the desorption-end temperature to 90 °C. The corresponding s amount to 0.50 and 0.40, respectively, which represent quite promising results for further design optimizations.}, language = {en} }