@unpublished{MuellerWeiglMuellerWilliamsetal., author = {M{\"u}ller, Max and Weigl, Stefan and M{\"u}ller-Williams, Jennifer and Lindauer, Matthias and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Ambient methane monitoring at Hohenpeißenberg utilizing photoacoustic spectroscopy and cavity ring down spectroscopy}, doi = {10.5194/egusphere-2023-1010}, abstract = {With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10-9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 \% from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.}, language = {en} } @article{MuellerWeiglMuellerWilliamsetal., author = {M{\"u}ller, Max and Weigl, Stefan and M{\"u}ller-Williams, Jennifer and Lindauer, Matthias and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Comparison of photoacoustic spectroscopy and cavity ring-down spectroscopy for ambient methane monitoring at Hohenpeißenberg}, series = {Atmospheric Measurement Techniques}, volume = {16}, journal = {Atmospheric Measurement Techniques}, number = {18}, publisher = {Copernicus Publications}, issn = {1867-8548}, doi = {10.5194/amt-16-4263-2023}, pages = {4263 -- 4270}, abstract = {With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10-9), methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a 5 d period at Hohenpeißenberg, Germany. As a reference device, a calibrated cavity ring-down spectrometer, Picarro G2301, from the meteorological observatory of the German Weather Service (DWD) was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to fluctuating environmental conditions, e.g. ambient humidity. The obtained results show that for PA sensor systems non-radiative relaxation effects induced by varying humidity are a non-negligible factor. Applying algorithm compensation techniques, which are capable of calculating the influence of non-radiative relaxation effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 \% from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.}, language = {en} } @inproceedings{CantalloubeGomezGonzalezAbsiletal., author = {Cantalloube, Faustine and Gomez-Gonzalez, Carlos and Absil, Olivier and Cantero, Carles and Bacher, Regis and Bonse, Markus and Bottom, Michael and Dahlqvist, Carl-Henrik and Desgrange, C{\´e}lia and Flasseur, Olivier and Fuhrmann, Thomas and Henning, Thomas H. and Jensen-Clem, Rebecca and Kenworthy, Matthew and Mawet, Dimitri and Mesa, Dino and Meshkat, Tiffany and Mouillet, David and M{\"u}ller, Andr{\´e} and Nasedkin, Evert and Pairet, Benoit and Pi{\´e}rard, S{\´e}bastien and Ruffio, Jean-Baptiste and Samland, Matthias and Stone, Jordan and van Droogenbroeck, Marc}, title = {Exoplanet imaging data challenge: benchmarking the various image processing methods for exoplanet detection}, series = {Adaptive Optics Systems VII : 14-22 December 2020, online only, United States}, booktitle = {Adaptive Optics Systems VII : 14-22 December 2020, online only, United States}, editor = {Schmidt, Dirk and Schreiber, Laura and Vernet, Elise}, publisher = {SPIE}, isbn = {9781510636835}, doi = {10.1117/12.2574803}, pages = {321}, abstract = {The Exoplanet Imaging Data Challenge is a community-wide effort meant to offer a platform for a fair and common comparison of image processing methods designed for exoplanet direct detection. For this purpose, it gathers on a dedicated repository (Zenodo), data from several high-contrast ground-based instruments worldwide in which we injected synthetic planetary signals. The data challenge is hosted on the CodaLab competition platform, where participants can upload their results. The specifications of the data challenge are published on our website https://exoplanet-imaging-challenge.github.io/. The first phase, launched on the 1st of September 2019 and closed on the 1st of October 2020, consisted in detecting point sources in two types of common data-set in the field of high-contrast imaging: data taken in pupil-tracking mode at one wavelength (subchallenge 1, also referred to as ADI) and multispectral data taken in pupil-tracking mode (subchallenge 2, also referred to as ADI+mSDI). In this paper, we describe the approach, organisational lessons-learnt and current limitations of the data challenge, as well as preliminary results of the participants' submissions for this first phase. In the future, we plan to provide permanent access to the standard library of data sets and metrics, in order to guide the validation and support the publications of innovative image processing algorithms dedicated to high-contrast imaging of planetary systems.}, language = {en} } @article{PangerlMuellerRuecketal., author = {Pangerl, Jonas and M{\"u}ller, Max and R{\"u}ck, Thomas and Weigl, Stefan and Bierl, Rudolf}, title = {Characterizing a sensitive compact mid-infrared photoacoustic sensor for methane, ethane and acetylene detection considering changing ambient parameters and bulk composition (N2, O2 and H2O)}, series = {Sensors and Actuators B: Chemical}, volume = {352,1}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, doi = {10.1016/j.snb.2021.130962}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-25868}, pages = {1 -- 12}, abstract = {We present a sensitive and compact interband cascade laser (ICL) based photoacoustic setup for the detection of gaseous hydrocarbons and discuss its applicability towards trace gas analysis. We investigated the performance of the sensor for trace concentrations of methane, ethane and acetylene diluted in nitrogen. The excitation of methane and ethane was accomplished using one tunable diode laser, covering a range from 3360 to 3372 nm, which was replaced by a separate ICL at 3025 nm for acetylene detection. The influence of ambient parameters such as temperature, flow rate and pressure as well as potential cross-sensitivities towards O2 and H2O have been examined in terms of methane and acetylene detection. A series of simulations proved several of these influences to be attributed to relaxation effects. With a 3σ limit of detection (LoD) of 6.8 parts per billion (ppbV) in case of methane, 2.3 ppbV regarding ethane and 3.6 ppbV in terms of acetylene, the sensor demonstrates a great potential for applications in the field of trace gas analysis.}, language = {en} } @article{MuellerRueckJobstetal., author = {M{\"u}ller, Max and R{\"u}ck, Thomas and Jobst, Simon and Pangerl, Jonas and Weigl, Stefan and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An Algorithmic Approach to Compute the Effect of Non-Radiative Relaxation Processes in Photoacoustic Spectroscopy}, series = {Photoacoustics}, volume = {26}, journal = {Photoacoustics}, publisher = {Elsevier}, doi = {10.1016/j.pacs.2022.100371}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-39935}, abstract = {Successful transfer of photoacoustic gas sensors from laboratory to real-life applications requires knowledge about potential cross-sensitivities towards environmental and gas matrix changes. Multi-dimensional calibration in case of cross-sensitivities can become very complex or even unfeasible. To address this challenge, we present a novel algorithm to compute the collision based non-radiative efficiency and phase lag of energy relaxation on a molecular level (CoNRad) for photoacoustic signal calculation. This algorithmic approach allows to calculate the entire elaxation cascade of arbitrarily complex systems, yielding a theoretical photoacoustic signal. In this work the influence of varying bulk compositions, i.e. nitrogen (N2), oxygen (O2) and water (H2O) on the photoacoustic signal during methane (CH4) detection is demonstrated. The applicability of the algorithm to other photoacoustic setups is shown exemplary by applying it to the relaxational system investigated in [1]. Hayden et al. examined the effect of water on photoacoustic carbon monoxide (CO) detection.}, language = {en} } @techreport{SteigerFoltanPhilippetal., type = {Working Paper}, author = {Steiger, Tamara and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Gruber, Michael and Bredthauer, Andre and Krenkel, Lars and Birkenmaier, Clemens and Lehle, Karla}, title = {Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients?}, abstract = {Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots—in particular, the presence of von Willebrand factor (vWF)—may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4′,6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.}, language = {en} } @article{BirkenmaierDorniaLehleetal., author = {Birkenmaier, Clemens and Dornia, Christian and Lehle, Karla and M{\"u}ller, Thomas and Gruber, Michael and Philipp, Alois and Krenkel, Lars}, title = {Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study}, series = {ASAIO Journal / American Society for Artificial Internal Organs}, volume = {66}, journal = {ASAIO Journal / American Society for Artificial Internal Organs}, number = {8}, publisher = {Lippincott Williams \& Wilkins}, issn = {1538-943X}, doi = {10.1097/MAT.0000000000001089}, pages = {922 -- 928}, abstract = {Coagulative disorders, especially clotting during extracorporeal membrane oxygenation, are frequent complications. Direct visualization and analysis of deposits in membrane oxygenators using computed tomography (CT) may provide an insight into the underlying mechanisms causing thrombotic events. However, the already established multidetector CT1 (MDCT) method shows major limitations. Here, we demonstrate the feasibility of applying industrial micro-CT (μCT) to circumvent these restrictions. Three clinically used membrane oxygenators were investigated applying both MDCT and μCT. The scans were analyzed in terms of clot volume and local clot distribution. As validation, the clot volume was also determined from the fluid volume, which could be filled into the respective used oxygenator compared to a new device. In addition, cross-sectional CT images were compared with crosscut oxygenators. Based on the μCT findings, a morphological measure (sphericity) for assessing clot structures in membrane oxygenators is introduced. Furthermore, by comparing MDCT and μCT results, an augmentation of the MDCT method is proposed, which allows for improved clot volume determination in a clinical setting.}, language = {en} } @incollection{MuellerFalter, author = {M{\"u}ller, Andreas and Falter, Thomas}, title = {Sechs F{\"u}hrungsperspektiven f{\"u}r die digitale Transformation - Welche Dashboards das Ver{\"a}nderungsmanagement in digitalen Zeiten unterst{\"u}tzen k{\"o}nnen}, series = {Arbeitskulturen im Wandel}, booktitle = {Arbeitskulturen im Wandel}, editor = {W{\"o}rwag, Sebastian and Cloots, Alexandra}, publisher = {Springer Gabler}, address = {Wiesbaden}, isbn = {978-3-658-30450-8}, doi = {10.1007/978-3-658-30451-5_12}, pages = {239 -- 257}, abstract = {W{\"a}hrend KPIs und Dashboards in großer Zahl f{\"u}r den Betrieb eines Unternehmens im eingeschwungenen Zustand zur Verf{\"u}gung stehen, scheint es insbesondere in der digitalen Transformation besonders schwierig zu sein, Orientierung zu behalten und zu vermitteln. Welche Aspekte sind dabei wichtig? Was ist der Einfluss der Unternehmenskultur? In welcher Reihenfolge sollen wir vorgehen? Wie k{\"o}nnen wir die wichtigen Parameter messen und visualisieren? Auf diese Fragen geben wir unter Ber{\"u}cksichtigung unterschiedlicher Modelle und Perspektiven Antworten und zeigen am hypothetischen Beispiel eines Autohauses m{\"o}gliche konkrete Aktionen exemplarisch auf.}, language = {de} } @techreport{BurlonEmdeHoenigetal., author = {Burlon, Thomas and Emde, Markus and H{\"o}nig, Tobias and M{\"u}ller, Cornelia and Neznanow, Arthur and Rampl, Markus and Sammut, Alexine and Schl{\"u}ßler, Kristof and Sievert Asmussen, Eva}, title = {0169 Karl-Hammerschmidt-Straße, Architekturkultur}, language = {de} } @unpublished{RueckMuellerJobstetal., author = {R{\"u}ck, Thomas and M{\"u}ller, Max and Jobst, Simon and Weigl, Stefan and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions}, publisher = {Elsevier / SSRN}, doi = {10.2139/ssrn.4215170}, pages = {22}, abstract = {The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 \% the accuracy of the sensor after DT compensation significantly exceeds the 24 \% achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species.}, language = {en} } @inproceedings{MuellerRueckJobstetal., author = {M{\"u}ller, Max and R{\"u}ck, Thomas and Jobst, Simon and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Creating a Digital Twin of a Photoacoustic Gas Sensor for Methane Detection in Complex Gas Matrices}, series = {Proceedings Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES): 11-15 July 2022, Vancouver, British Columbia, Canada}, booktitle = {Proceedings Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES): 11-15 July 2022, Vancouver, British Columbia, Canada}, publisher = {Optica Publishing Group}, isbn = {978-1-957171-10-4}, doi = {10.1364/LACSEA.2022.LW4D.2}, abstract = {We present the calculation results from a digital twin (DT) of our photoacoustic (PA) sensor for methane detection, regarding gas composition, temperature and pressure variations.}, language = {en} } @article{SchrollDeckerMuellerWesemann, author = {Schroll-Decker, Irmgard and M{\"u}ller, Thomas and Wesemann, Anna}, title = {Wohlbefinden von Kindern und Jugendlichen im Heim}, series = {Unsere Jugend}, volume = {61}, journal = {Unsere Jugend}, number = {11+12}, publisher = {Reinhardt}, issn = {0342-5258}, pages = {490 -- 504}, language = {de} } @unpublished{MuellerFalter, author = {M{\"u}ller, Andreas and Falter, Thomas}, title = {When Work (Re)releases Energy: Five steps towards regenerative people management}, doi = {10.13140/RG.2.2.10446.57928}, abstract = {In this article, we explore the innovative concept of regenerative work, which positions itself as a response to the challenges of the modern working world. At the core of our discussion are five phases of work design: from conventional (degenerative) work, often perceived as burdensome, through employee-oriented work, human-centeredness, restorative work, and finally to regenerative work, which can return energy to employees (and the environment). We examine the influence that leaders, employees, and HR professionals can have on designing working conditions, jobs, and teams. Practical examples illustrate how companies can achieve a positive energy balance for employees and teams through energy analysis. We emphasize that regenerative work is not a distant ideal but an achievable goal that can be realized through the conscious design of the workplace.}, language = {en} } @article{RueckMuellerJobstetal., author = {R{\"u}ck, Thomas and M{\"u}ller, Max and Jobst, Simon and Weigl, Stefan and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {378}, doi = {10.1016/j.snb.2022.133119}, abstract = {The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 \% the accuracy of the sensor after DT compensation significantly exceeds the 24 \% achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species.}, language = {en} } @inproceedings{MuellerDannerBreidbachetal., author = {M{\"u}ller, Stefan and Danner, Christian and Breidbach, J{\"o}rg and Seidl, Markus and Hußlein, Thomas and Lauf, Wolfgang}, title = {Stochastic Modeling of Throughput Times of Supplier Parts for an Automotive Plant}, series = {Angewandte Forschung in der Wirtschaftsinformatik - Prozesse, Technologie, Anwendungen, Systeme und Management 2014: Tagungsband zur 27. AKWI-Jahrestagung vom 07. bis zum 10.09.2014 an der Oberbayerischen Technischen Hochschule Regensburg}, booktitle = {Angewandte Forschung in der Wirtschaftsinformatik - Prozesse, Technologie, Anwendungen, Systeme und Management 2014: Tagungsband zur 27. AKWI-Jahrestagung vom 07. bis zum 10.09.2014 an der Oberbayerischen Technischen Hochschule Regensburg}, publisher = {News \& Media}, isbn = {978-3-936527-38-4}, doi = {10.15771/978-3-936527-38-4}, pages = {35 -- 43 S}, abstract = {For modern production industries optimized supply of parts is a critical success factor. Especially in the automotive industry, the reliable supply of painted bodies for the fi nal assembly is essential for OEMs considering just in time or just in sequence processes. Additionally one central cost target is the avoidance of resorting for JIT/JIS processes. An essential workfl ow analysis is therefore the basis for making strategic or operational decisions such as the adjustment of the plant structure or increasing the number of products and variants manufactured simultaneously. In order to support strategic planning using simulation and planning systems, the modeling of the production process is required. This is particularly important for scheduling as no real manufacturing data is available and therefore prognosis based on the model are essential. Due to the short time and the limited human resources for a detailed modeling, it is essential to create a robust model with good accuracy and reduced complexity}, language = {en} } @inproceedings{EscherMuellerRuecketal., author = {Escher, Lukas and M{\"u}ller, Max and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf}, title = {Digitaler Zwilling photoakustischer Spurengassensoren zur Prozess{\"u}berwachung}, series = {16. Dresdner Sensor-Symposium 2022: Vortr{\"a}ge}, booktitle = {16. Dresdner Sensor-Symposium 2022: Vortr{\"a}ge}, publisher = {AMA (Association for Sensors + Measurement)}, isbn = {978-3-9819376-7-1}, doi = {10.5162/16dss2022/3.3}, abstract = {Stickstoffdioxid (NO2) wird haupts{\"a}chlich durch anthropogene Verbrennungsprozesse in Verkehr und Industrie in die Umgebungsluft eingebracht [1]. Die stark reaktive, oxidative Wirkung von NO2 kann bei Exposition mit h{\"o}heren Konzentrationen Reizungen und allergische Reaktionen in den Atemwegen hervorrufen. Weiter f{\"u}hrt NO2 zur Bildung von saurem Regen, Smog und Ozon (O3) die sich ebenso negativ auf die menschliche Gesundheit und Umwelt auswirken [2,3]. Aufgrund dieser Effekte wird die Spurengaskonzentration von NO2 in der Luft in Deutschland an ausgew{\"a}hlten, verkehrsreichen Orten gemessen.}, language = {de} } @article{RueckPangerlEscheretal., author = {R{\"u}ck, Thomas and Pangerl, Jonas and Escher, Lukas and Jobst, Simon and M{\"u}ller, Max and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Kinetic cooling in mid-infrared methane photoacoustic spectroscopy: A quantitative analysis via digital twin verification}, series = {Photoacoustics}, volume = {40}, journal = {Photoacoustics}, publisher = {Elsevier}, doi = {10.1016/j.pacs.2024.100652}, abstract = {This study presents a detailed quantitative analysis of kinetic cooling in methane photoacoustic spectroscopy, leveraging the capabilities of a digital twin model. Using a quantum cascade laser tuned to 1210.01 cm⁻¹, we investigated the effects of varying nitrogen-oxygen matrix compositions on the photoacoustic signals of 15 ppmV methane. Notably, the photoacoustic signal amplitude decreased with increasing oxygen concentration, even falling below the background signal at oxygen levels higher than approximately 6 \%V. This phenomenon was attributed to kinetic cooling, where thermal energy is extracted from the surrounding gas molecules rather than added, as validated by complex vector analysis using a previously published digital twin model. The model accurately reproduced complex signal patterns through simulations, providing insights into the underlying molecular mechanisms by quantifying individual collision contributions. These findings underscore the importance of digital twins in understanding the fundamentals of photoacoustic signal generation at the molecular level.}, language = {en} } @misc{LautenschlaegerLeisDendorferetal., author = {Lautenschl{\"a}ger, Toni and Leis, Alexander and Dendorfer, Sebastian and Palm, Christoph and Schreiner, Rupert and Langer, Christoph and Prommesberger, Christian and Ławrowski, Robert Damian and Dams, Florian and Bornmann, Benjamin and Navitski, Aliaksandr and Serbun, Pavel and M{\"u}ller, G{\"u}nter and Liebetruth, Thomas and Kohlert, Dieter and Pernsteiner, Jochen and Schreier, Franz and Heerklotz, Sabrina and Heerklotz, Allwin and Boos, Alexander and Herwald, Dominik and Monkman, Gareth J. and Treiber, Daniel and Mayer, Matthias and H{\"o}rner, Eva and Bentz, Alexander and Shamonin (Chamonine), Mikhail and Johansen, S{\o}ren Peter and Reichel, Marco and Stoll, Andrea and Briem, Ulrich and Dullien, Silvia and Renkawitz, Tobias and Weber, Tim and Dendorfer, Sebastian and Grifka, Joachim and Penzkofer, Rainer and Barnsteiner, K. and Jovanovik, M. and Wernecke, P. and V{\"o}gele, A. and Bachmann, T. and Pl{\"o}tz, Martin and Schliekmann, Claus and Wels, Harald and Helmberger, Paul and Kaspar, Marcel and H{\"o}nicka, M. and Schrammel, Siegfried and Enser, Markus and Schmidmeier, Monika and Schroll-Decker, Irmgard and Haug, Sonja and Gelfert, Verena and Vernim, Matthias}, title = {Forschungsbericht 2012}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, doi = {10.35096/othr/pub-783}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-7834}, pages = {64}, language = {de} } @article{FoltanDinhGruberetal., author = {Foltan, Maik and Dinh, D. and Gruber, Michael and M{\"u}ller, Thomas and Hart, C. and Krenkel, Lars and Schmid, C. and Lehle, Karla}, title = {Incidence of neutrophil extracellular traps (NETs) in different membrane oxygenators: pilot in vitro experiments in commercially available coated membranes}, series = {Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs}, journal = {Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs}, doi = {10.1007/s10047-024-01486-4}, abstract = {Neutrophil extracellular traps (NETs) were detected in blood samples and in cellular deposits of oxygenator membranes during extracorporeal membrane oxygenation (ECMO) therapy and may be responsible for thrombogenesis. The aim was to evaluate the effect of the base material of gas fiber (GF, polymethylpentene) and heat exchange (HE) membranes and different antithrombogenic coatings on isolated granulocytes from healthy volunteers under static culture conditions. Contact of granulocytes with membranes from different ECMO oxygenators (with different surface coatings) and uncoated-GFs allowed detection of adherent cells and NETotic nuclear structures (normal, swollen, ruptured) using nuclear staining. Flow cytometry was used to identify cell activation (CD11b/CD62L, oxidative burst) of non-adherent cells. Uncoated-GFs were used as a reference. Within 3 h, granulocytes adhered to the same extent on all surfaces. In contrast, the ratio of normal to NETotic cells was significantly higher for uncoated-GFs (56-83\%) compared to all coated GFs (34-72\%) (p < 0.001) with no difference between the coatings. After material contact, non-adherent cells remained vital with unchanged oxidative burst function and the proportion of activated cells remained low. The expression of activation markers was independent of the origin of the GF material. In conclusion, the polymethylpentene surfaces of the GFs already induce NET formation. Antithrombogenic coatings can already reduce the proportion of NETotic nuclei. However, it cannot be ruled out that NET formation can induce thrombotic events. Therefore, new surfaces or coatings are required for future ECMO systems and long-term implantable artificial lungs.}, language = {en} } @article{PangerlMoserMuelleretal., author = {Pangerl, Jonas and Moser, Elisabeth and M{\"u}ller, Max and Weigl, Stefan and Jobst, Simon and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A sub-ppbv-level Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor- Characterization and Multi-Component Spectra Recording in Synthetic Breath}, series = {Photoacoustics}, volume = {30}, journal = {Photoacoustics}, publisher = {Elsevier}, issn = {2213-5979}, doi = {10.1016/j.pacs.2023.100473}, pages = {1 -- 12}, abstract = {Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far.}, language = {en} } @incollection{WeiglMuellerPangerletal., author = {Weigl, Stefan and M{\"u}ller, Max and Pangerl, Jonas and R{\"u}ck, Thomas}, title = {Scopes and Limits of Photoacoustic Spectroscopy in Modern Breath Analysis}, series = {Breath Analysis}, booktitle = {Breath Analysis}, publisher = {Springer nature}, isbn = {978-3-031-18526-7}, doi = {10.1007/11663_2022_22}, pages = {101 -- 159}, abstract = {Photoacoustic spectroscopy is a viable tool for trace gas detection in various application fields. In recent years, this technique has been exploited more and more for modern breath analysis as well. Within this chapter, a holistic overview of photoacoustic spectroscopy is presented, while maintaining the relationship to breath analysis. Therefore, a concise description of the fundamentals of photoacoustic spectroscopy is provided. This is essential for understanding the scopes and limits of this outstanding measurement technique being described within this chapter. In the past several different types of photoacoustic measurement setups for trace gas detection have emerged, including different light sources, modulation techniques, and detection schemes. These are described shortly and advantages as well as disadvantages, especially in relation to breath analysis, are highlighted. Though being a promising sensor principle, measurement devices based on photoacoustic spectroscopy are still rare on the sensor market, especially when it comes to trace gas detection in complex gas matrices, e.g., human breath exhale. One main reason is due to possible molecular interactions influencing the relaxational behavior of the analyte altering the sensor signal. Recent results shedding light on the intricate relaxational processes within complex gas matrices are discussed in detail, providing approaches to overcome this issue. Finally, various applications of photoacoustic spectroscopy in breath analysis are described demonstrating the great potential of this technology.}, language = {en} } @article{SteigerFoltanPhilippetal., author = {Steiger, Tamara and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Gruber, Michael and Bredthauer, Andre and Krenkel, Lars and Birkenmaier, Clemens and Lehle, Karla}, title = {Accumulations of von Willebrand factor within ECMO oxygenators: Potential indicator of coagulation abnormalities in critically ill patients?}, series = {Artificial Organs}, volume = {43}, journal = {Artificial Organs}, number = {11}, publisher = {Wiley}, address = {Hoboken}, issn = {1525-1594}, doi = {10.1111/aor.13513}, pages = {1065 -- 1076}, abstract = {Clot formation within membrane oxygenators (MOs) remains a critical problem during extracorporeal membrane oxygenation (ECMO). The composition of the clots-in particular, the presence of von Willebrand factor (vWF)-may be an indicator for prevalent nonphysiological flow conditions, foreign body reactions, or coagulation abnormalities in critically ill patients. Mats of interwoven gas exchange fibers from randomly collected MOs (PLS, Maquet, Rastatt, Germany) of 21 patients were stained with antibodies (anti-vWF and anti-P-selectin) and counterstained with 4 ',6-diamidino-2-phenylindole. The extent of vWF-loading was correlated with patient and technical data. While 12 MOs showed low vWF-loadings, 9 MOs showed high vWF-loading with highest accumulations close to crossing points of adjacent gas fibers. The presence and the extent of vWF-fibers/"cobwebs," leukocytes, platelet-leukocyte aggregates (PLAs), and P-selectin-positive platelet aggregates were independent of the extent of vWF-loading. However, the highly loaded MOs were obtained from patients with a significantly elevated SOFA score, severe thrombocytopenia, and persistent liver dysfunction. The coagulation abnormalities of these critically ill patients may cause an accumulation of the highly thrombogenic and elongated high-molecular-weight vWF multimers in the plasma which will be trapped in the MOs during the ECMO therapy.}, language = {en} } @unpublished{PangerlMoserMuelleretal., author = {Pangerl, Jonas and Moser, Elisabeth and M{\"u}ller, Max and Weigl, Stefan and Jobst, Simon and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A Highly Sensitive Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor: Characterization and Multi-Component Spectra Recording in Synthetic Breath}, series = {SSRN Electronic Journal}, journal = {SSRN Electronic Journal}, publisher = {Elsevier}, doi = {10.2139/ssrn.4305376}, abstract = {Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8260 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbV in terms of ethanol and 250 pptV regarding acetone, our system is among the best performing presented so far.}, language = {en} } @article{HausFoltanPhilippetal., author = {Haus, Moritz and Foltan, Maik and Philipp, Alois and M{\"u}ller, Thomas and Lingel, Maximilian P. and Krenkel, Lars and Gruber, Michael and Lehle, Karla}, title = {Neutrophil extracellular traps -a potential trigger for the development of thrombocytopenia during extracorporeal membrane oxygenation}, volume = {15}, publisher = {frontiers}, doi = {10.3389/fimmu.2024.1339235}, abstract = {Neutrophil extracellular traps (NETs) have recently emerged as a potential link between inflammation, immunity, and thrombosis, as well as other coagulation disorders which present a major challenge in the context of extracorporeal membrane oxygenation (ECMO). By examining blood from ECMO patients for NETs and their precursors and correlating them with clinical and laboratory biomarkers of coagulation and inflammation, this study aims to evaluate the association between the presence of NETs in the bloodstream of ECMO patients and the development of potentially severe coagulation disorders during ECMO therapy. Therefore, blood samples were collected from healthy volunteers (n=13) and patients receiving veno-venous (VV) ECMO therapy (n=10). To identify NETs and their precursors, DNA and myeloperoxidase as well as granulocyte marker CD66b were visualized simultaneously by immunofluorescence staining in serial blood smears. Differentiation of DNA-containing objects and identification of NETs and their precursors was performed semiautomatically by a specific algorithm using the shape and size of DNA staining and the intensity of MPO and CD66b signal. Neutrophil extracellular traps and their precursors could be detected in blood smears from patients requiring VV ECMO. Compared to volunteers, ECMO patients presented significantly higher rates of NETs and NET precursors as well as an increased proportion of neutrophil granulocytes in all detected nucleated cells. A high NET rate prior to the initiation of ECMO therapy was associated with both increased iL-6 and TNF-α levels as an expression of a high cytokine burden. These patients with increased NET release also presented an earlier and significantly more pronounced decrease in platelet counts and ATIII activity following initiation of therapy compared with patients with less elevated NETs. These findings provide further indications for the development of immune-mediated acquired thrombocytopenia in ECMO patients.}, language = {en} } @article{KleinNabbefeldHattabetal., author = {Klein, C. and Nabbefeld, T. and Hattab, H. and Meyer, D. and Jnawali, G. and Kammler, Martin and Meyer zu Heringdorf, Frank-Joachim and Golla-Franz, A. and M{\"u}ller, B. H. and Schmidt, Thomas and Henzler, M. and Horn-von Hoegen, Michael}, title = {Lost in reciprocal space? Determination of the scattering condition in spot profile analysis low-energy electron diffraction}, series = {Review of scientific instruments}, volume = {82}, journal = {Review of scientific instruments}, number = {3}, publisher = {American Institute of Physics}, doi = {10.1063/1.3554305}, abstract = {The precise knowledge of the diffraction condition, i.e., the angle of incidence and electron energy, is crucial for the study of surface morphology through spot profile analysis low-energy electron diffraction (LEED). We demonstrate four different procedures to determine the diffraction condition: employing the distortion of the LEED pattern under large angles of incidence, the layer-by-layer growth oscillations during homoepitaxial growth, a G(S) analysis of a rough surface, and the intersection of facet rods with 3D Bragg conditions.}, language = {en} } @misc{WeberSonarGerhardsetal., author = {Weber, Karsten and Sonar, Arne and Gerhards, Helene and Bittner, Uta and Krug, Henriette and Reuter-Oppermann, Melanie and Pumplun, Luisa and M{\"u}ller, Helene and Buxmann, Peter and Schneider, Diana and Zoglauer, Thomas}, title = {K{\"u}nstliche Intelligenz und Gesundheit}, editor = {Sonar, Arne and Weber, Karsten}, publisher = {Franz Steiner}, address = {Stuttgart}, isbn = {978-3-515-12977-0}, doi = {10.25162/9783515129770}, abstract = {Der Einsatz von k{\"u}nstlicher Intelligenz im Gesundheitsbereich verspricht besonders großen Nutzen durch eine bessere Versorgung sowie effizientere Abl{\"a}ufe und bietet damit letztlich auch {\"o}konomische Vorteile. Dem stehen unter anderem Bef{\"u}rchtungen entgegen, dass sich durch den Einsatz von k{\"u}nstlicher Intelligenz das Arzt-Patienten-Verh{\"a}ltnis ver{\"a}ndern k{\"o}nnte, Arbeitspl{\"a}tze gef{\"a}hrdet seien oder die {\"O}konomisierung des Gesundheitswesens einen weiteren Schub erfahren k{\"o}nnte. Zuweilen wird die Debatte um diese Technologie, zumal in der {\"O}ffentlichkeit, emotional und fern sachlicher Argumente gef{\"u}hrt. Die Autorinnen und Autoren untersuchen die Geschichte des KI-Einsatzes in der Medizin, deren {\"o}ffentliche Wahrnehmung, Governance der KI, die M{\"o}glichkeiten und Grenzen der Technik sowie Einsatzgebiete, die bisher noch nicht oder nur wenig im Fokus der Aufmerksamkeit waren. Dabei erweist sich die KI als leistungsf{\"a}higes Werkzeug, das zahlreiche ethische und soziale Fragen aufwirft, die bei der Einf{\"u}hrung anderer Technologien bereits gestellt wurden; allerdings gibt es auch neue Herausforderungen, denen sich Professionen, Politik und Gesellschaft stellen m{\"u}ssen.}, language = {de} } @article{BeyerWeigertQuicketal., author = {Beyer, Thomas and Weigert, Markus and Quick, Harald H. and Pietrzyk, Uwe and Vogt, Florian and Palm, Christoph and Antoch, Gerald and M{\"u}ller, Stefan P. and Bockisch, Andreas}, title = {MR-based attenuation correction for torso-PET/MR imaging}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {35}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {6}, doi = {10.1007/s00259-008-0734-0}, pages = {1142 -- 1146}, abstract = {Purpose MR-based attenuation correction (AC) will become an integral part of combined PET/MR systems. Here, we propose a toolbox to validate MR-AC of clinical PET/MRI data sets. Methods Torso scans of ten patients were acquired on a combined PET/CT and on a 1.5-T MRI system. MR-based attenuation data were derived from the CT following MR-CT image co-registration and subsequent histogram matching. PET images were reconstructed after CT- (PET/CT) and MR-based AC (PET/MRI). Lesion-to-background (L/B) ratios were estimated on PET/CT and PET/MRI. Results MR-CT histogram matching leads to a mean voxel intensity difference in the CT- and MR-based attenuation images of 12\% (max). Mean differences between PET/MRI and PET/CT were 19\% (max). L/B ratios were similar except for the lung where local misregistration and intensity transformation leads to a biased PET/MRI. Conclusion Our toolbox can be used to study pitfalls in MR-AC. We found that co-registration accuracy and pixel value transformation determine the accuracy of PET/MRI.}, subject = {Kernspintomografie}, language = {en} } @article{WeigertPietrzykMuelleretal., author = {Weigert, Markus and Pietrzyk, Uwe and M{\"u}ller, Stefan P. and Palm, Christoph and Beyer, Thomas}, title = {Whole-body PET/CT imaging}, series = {Zeitschrift f{\"u}r Medizinische Physik}, volume = {18}, journal = {Zeitschrift f{\"u}r Medizinische Physik}, number = {1}, doi = {10.1016/j.zemedi.2007.07.004}, pages = {59 -- 66}, abstract = {Aim Combined whole-body (WB) PET/CT imaging provides better overall co-registration compared to separate CT and PET. However, in clinical routine local PET-CT mis-registration cannot be avoided. Thus, the reconstructed PET tracer distribution may be biased when using the misaligned CT transmission data for CT-based attenuation correction (CT-AC). We investigate the feasibility of retrospective co-registration techniques to align CT and PET images prior to CT-AC, thus improving potentially the quality of combined PET/CT imaging in clinical routine. Methods First, using a commercial software registration package CT images were aligned to the uncorrected PET data by rigid and non-rigid registration methods. Co-registration accuracy of both alignment approaches was assessed by reviewing the PET tracer uptake patterns (visual, linked cursor display) following attenuation correction based on the original and co-registered CT. Second, we investigated non-rigid registration based on a prototype ITK implementation of the B-spline algorithm on a similar targeted MR-CT registration task, there showing promising results. Results Manual rigid, landmark-based co-registration introduced unacceptable misalignment, in particular in peripheral areas of the whole-body images. Manual, non-rigid landmark-based co-registration prior to CT-AC was successful with minor loco-regional distortions. Nevertheless, neither rigid nor non-rigid automatic co-registration based on the Mutual Information image to image metric succeeded in co-registering the CT and noAC-PET images. In contrast to widely available commercial software registration our implementation of an alternative automated, non-rigid B-spline co-registration technique yielded promising results in this setting with MR-CT data. Conclusion In clinical PET/CT imaging, retrospective registration of CT and uncorrected PET images may improve the quality of the AC-PET images. As of today no validated and clinically viable commercial registration software is in routine use. This has triggered our efforts in pursuing new approaches to a validated, non-rigid co-registration algorithm applicable to whole-body PET/CT imaging of which first results are presented here. This approach appears suitable for applications in retrospective WB-PET/CT alignment. Ziel Kombinierte PET/CT-Bildgebung erm{\"o}glicht verbesserte Koregistrierung von PET- und CT-Daten gegen{\"u}ber separat akquirierten Bildern. Trotzdem entstehen in der klinischen Anwendung lokale Fehlregistrierungen, die zu Fehlern in der rekonstruierten PET- Tracerverteilung f{\"u}hren k{\"o}nnen, falls die unregistrierten CT-Daten zur Schw{\"a}chungskorrektur (AC) der Emissionsdaten verwendet werden. Wir untersuchen daher die Anwendung von Bildregistrierungsalgorithmen vor der CT-basierten AC zur Verbesserung der PET-Aufnahmen. Methoden Mittels einer kommerziellen Registrierungssoftware wurden die CT-Daten eines PET/CT- Tomographen durch landmarken- und intensit{\"a}tsbasierte rigide (starre) und nicht-rigide Registrierungsverfahren r{\"a}umlich an die unkorrigierten PET-Emissionsdaten angepasst und zur AC verwendet. Zur Bewertung wurden die Tracerverteilungen in den PET-Bildern (vor AC, CT-AC, CT-AC nach Koregistrierung) visuell und mit Hilfe korrelierter Fadenkreuze verglichen. Zus{\"a}tzlich untersuchten wir die ITK-Implementierung der bekannten B-spline basierten, nicht-rigiden Registrierungsans{\"a}tze im Hinblick auf ihre Verwendbarkeit f{\"u}r die multimodale PET/CT-Ganzk{\"o}rperregistrierung. Ergebnisse Mittels landmarkenbasierter, nicht-rigider Registrierung konnte die Tracerverteilung in den PET-Daten lokal verbessert werden. Landmarkenbasierte rigide Registrierung f{\"u}hrte zu starker Fehlregistrierung in entfernten K{\"o}rperregionen. Automatische rigide und nicht-rigide Registrierung unter Verwendung der Mutual-Information-{\"A}hnlichkeitsmetrik versagte auf allen verwendeten Datens{\"a}tzen. Die automatische Registrierung mit B-spline-Funktionen zeigte vielversprechende Resultate in der Anwendung auf einem {\"a}hnlich gelagerten CT-MR-Registrierungsproblem. Fazit Retrospektive, nicht-rigide Registrierung unkorrigierter PET- und CT-Aufnahmen aus kombinierten Aufnahmensystemen vor der AC kann die Qualit{\"a}t von PET-Aufnahmen im klinischen Einsatz verbessern. Trotzdem steht bis heute im klinischen Alltag keine validierte, automatische Registrierungssoftware zur Verf{\"u}gung. Wir verfolgen dazu Ans{\"a}tze f{\"u}r validierte, nicht-rigide Bildregistrierung f{\"u}r den klinischen Einsatz und pr{\"a}sentieren erste Ergebnisse.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @misc{BeyerWeigertPalmetal., author = {Beyer, Thomas and Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Vogt, Florian and Martinez, M.J. and Bockisch, Andreas}, title = {Towards MR-based attenuation correction for whole-body PET/MR imaging}, series = {The Journal of Nuclear Medicine}, volume = {47}, journal = {The Journal of Nuclear Medicine}, number = {Suppl. 1}, pages = {384P}, subject = {Kernspintomografie}, language = {en} } @misc{WeigertBeyerQuicketal., author = {Weigert, Markus and Beyer, Thomas and Quick, Harald H. and Pietrzyk, Uwe and Palm, Christoph and M{\"u}ller, Stefan P.}, title = {Generation of a MRI reference data set for the validation of automatic, non-rigid image co-registration algorithms}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A116}, subject = {Kernspintomografie}, language = {en} } @misc{WeigertPalmQuicketal., author = {Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Beyer, Thomas}, title = {Template for MR-based attenuation correction for whole-body PET/MR imaging}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A115}, subject = {Kernspintomografie}, language = {en} } @article{LehlePhilippKrenkeletal., author = {Lehle, Karla and Philipp, Alois and Krenkel, Lars and Gruber, Michael and Hiller, Karl-Anton and M{\"u}ller, Thomas and Lubnow, Matthias}, title = {Thrombocytopenia During Venovenous Extracorporeal Membrane Oxygenation in Adult Patients With Bacterial, Viral, and COVID-19 Pneumonia}, series = {ASAIO Journal}, journal = {ASAIO Journal}, publisher = {Wolters Kluwer}, issn = {1058-2916}, doi = {10.1097/MAT.0000000000002383}, abstract = {Contact of blood with artificial surfaces triggers platelet activation. The aim was to compare platelet kinetics after venovenous extracorporeal membrane oxygenation (V-V ECMO) start and after system exchange in different etiologies of acute lung failure. Platelet counts and coagulation parameters were analyzed from adult patients with long and exchange-free (≥8 days) ECMO runs (n = 330) caused by bacterial (n = 142), viral (n = 76), or coronavirus disease 2019 (COVID-19) (n = 112) pneumonia. A subpopulation requiring a system exchange and with long, exchange-free runs of the second oxygenator (≥7 days) (n = 110) was analyzed analogously. Patients with COVID-19 showed the highest platelet levels before ECMO implantation. Independent of the underlying disease and ECMO type, platelet counts decreased significantly within 24 hours and reached a steady state after 5 days. In the subpopulation, at the day of a system exchange, platelet counts were lower compared with ECMO start, but without differences between underlying diseases. Subsequently, platelets remained unchanged in the bacterial pneumonia group, but increased in the COVID-19 and viral pneumonia groups within 2-4 days, whereas D-dimers decreased and fibrinogen levels increased. Thus, overall platelet counts on V-V ECMO show disease-specific initial dynamics followed by an ongoing consumption by the ECMO device, which is not boosted by new artificial surfaces after a system exchange.}, language = {en} } @misc{KranzWagnerPointneretal., author = {Kranz, Michael and Wagner, Maria Stella and Pointner, Daniel and Waldbauer, Selina and M{\"u}ller, Thomas and Lubnow, Matthias and Foltan, Maik and Krenkel, Lars and Lehle, Karla}, title = {Polymeric Embedding of Membrane Lungs: A Novel Method for Histological Investigations of Intra-Device Clot Formation}, series = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, journal = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, language = {en} } @misc{KranzWagnerKrenkeletal., author = {Kranz, Michael and Wagner, Maria Stella and Krenkel, Lars and M{\"u}ller, Thomas and Lubnow, Matthias and Philipp, Alois and Lehle, Karla}, title = {Clot Localization within Membrane Lungs using different Imaging Methods and Histological Clot Characterization as a way to prevent Thrombosis in Extracorporeal Membrane Oxygenation}, volume = {2023}, language = {en} } @misc{KoesterKranzWagneretal., author = {K{\"o}ster, Leonie and Kranz, Michael and Wagner, Maria Stella and Foltan, Maik and M{\"u}ller, Thomas and Lubnow, Matthias and Krenkel, Lars and Lehle, Karla}, title = {Histological Investigations of Intra-Device Clot Formation in ECMO Pumps}, series = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, journal = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, language = {en} }