@unpublished{MuellerWeiglMuellerWilliamsetal., author = {M{\"u}ller, Max and Weigl, Stefan and M{\"u}ller-Williams, Jennifer and Lindauer, Matthias and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Ambient methane monitoring at Hohenpeißenberg utilizing photoacoustic spectroscopy and cavity ring down spectroscopy}, doi = {10.5194/egusphere-2023-1010}, abstract = {With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10-9) methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective, is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a five day period at Hohenpeißenberg, Germany. As a reference device a calibrated cavity ringdown spectrometer Picarro G2301 from the meteorological observatory was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to environmental influences. The obtained results show that relaxation effects due to fluctuating environmental conditions, e.g. ambient humidity, are a non-negligible factor in PA sensor systems. Applying algorithm compensation techniques, which are capable of calculating the influence of relaxational effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 \% from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.}, language = {en} } @article{MuellerWeiglMuellerWilliamsetal., author = {M{\"u}ller, Max and Weigl, Stefan and M{\"u}ller-Williams, Jennifer and Lindauer, Matthias and R{\"u}ck, Thomas and Jobst, Simon and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Comparison of photoacoustic spectroscopy and cavity ring-down spectroscopy for ambient methane monitoring at Hohenpeißenberg}, series = {Atmospheric Measurement Techniques}, volume = {16}, journal = {Atmospheric Measurement Techniques}, number = {18}, publisher = {Copernicus Publications}, issn = {1867-8548}, doi = {10.5194/amt-16-4263-2023}, pages = {4263 -- 4270}, abstract = {With an atmospheric concentration of approximately 2000 parts per billion (ppbV, 10-9), methane (CH4) is the second most abundant greenhouse gas (GHG) in the atmosphere after carbon dioxide (CO2). The task of long-term and spatially resolved GHG monitoring to verify whether climate policy actions are effective is becoming more crucial as climate change progresses. In this paper we report the CH4 concentration readings of our photoacoustic (PA) sensor over a 5 d period at Hohenpeißenberg, Germany. As a reference device, a calibrated cavity ring-down spectrometer, Picarro G2301, from the meteorological observatory of the German Weather Service (DWD) was employed. Trace gas measurements with photoacoustic instruments promise to provide low detection limits at comparably low costs. However, PA devices are often susceptible to cross-sensitivities related to fluctuating environmental conditions, e.g. ambient humidity. The obtained results show that for PA sensor systems non-radiative relaxation effects induced by varying humidity are a non-negligible factor. Applying algorithm compensation techniques, which are capable of calculating the influence of non-radiative relaxation effects on the photoacoustic signal, increase the accuracy of the photoacoustic sensor significantly. With an average relative deviation of 1.11 \% from the G2301, the photoacoustic sensor shows good agreement with the reference instrument.}, language = {en} } @article{PangerlMuellerRuecketal., author = {Pangerl, Jonas and M{\"u}ller, Max and R{\"u}ck, Thomas and Weigl, Stefan and Bierl, Rudolf}, title = {Characterizing a sensitive compact mid-infrared photoacoustic sensor for methane, ethane and acetylene detection considering changing ambient parameters and bulk composition (N2, O2 and H2O)}, series = {Sensors and Actuators B: Chemical}, volume = {352,1}, journal = {Sensors and Actuators B: Chemical}, publisher = {Elsevier}, doi = {10.1016/j.snb.2021.130962}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-25868}, pages = {1 -- 12}, abstract = {We present a sensitive and compact interband cascade laser (ICL) based photoacoustic setup for the detection of gaseous hydrocarbons and discuss its applicability towards trace gas analysis. We investigated the performance of the sensor for trace concentrations of methane, ethane and acetylene diluted in nitrogen. The excitation of methane and ethane was accomplished using one tunable diode laser, covering a range from 3360 to 3372 nm, which was replaced by a separate ICL at 3025 nm for acetylene detection. The influence of ambient parameters such as temperature, flow rate and pressure as well as potential cross-sensitivities towards O2 and H2O have been examined in terms of methane and acetylene detection. A series of simulations proved several of these influences to be attributed to relaxation effects. With a 3σ limit of detection (LoD) of 6.8 parts per billion (ppbV) in case of methane, 2.3 ppbV regarding ethane and 3.6 ppbV in terms of acetylene, the sensor demonstrates a great potential for applications in the field of trace gas analysis.}, language = {en} } @article{MuellerRueckJobstetal., author = {M{\"u}ller, Max and R{\"u}ck, Thomas and Jobst, Simon and Pangerl, Jonas and Weigl, Stefan and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An Algorithmic Approach to Compute the Effect of Non-Radiative Relaxation Processes in Photoacoustic Spectroscopy}, series = {Photoacoustics}, volume = {26}, journal = {Photoacoustics}, publisher = {Elsevier}, doi = {10.1016/j.pacs.2022.100371}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-39935}, abstract = {Successful transfer of photoacoustic gas sensors from laboratory to real-life applications requires knowledge about potential cross-sensitivities towards environmental and gas matrix changes. Multi-dimensional calibration in case of cross-sensitivities can become very complex or even unfeasible. To address this challenge, we present a novel algorithm to compute the collision based non-radiative efficiency and phase lag of energy relaxation on a molecular level (CoNRad) for photoacoustic signal calculation. This algorithmic approach allows to calculate the entire elaxation cascade of arbitrarily complex systems, yielding a theoretical photoacoustic signal. In this work the influence of varying bulk compositions, i.e. nitrogen (N2), oxygen (O2) and water (H2O) on the photoacoustic signal during methane (CH4) detection is demonstrated. The applicability of the algorithm to other photoacoustic setups is shown exemplary by applying it to the relaxational system investigated in [1]. Hayden et al. examined the effect of water on photoacoustic carbon monoxide (CO) detection.}, language = {en} } @unpublished{RueckMuellerJobstetal., author = {R{\"u}ck, Thomas and M{\"u}ller, Max and Jobst, Simon and Weigl, Stefan and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions}, publisher = {Elsevier / SSRN}, doi = {10.2139/ssrn.4215170}, pages = {22}, abstract = {The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 \% the accuracy of the sensor after DT compensation significantly exceeds the 24 \% achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species.}, language = {en} } @article{RueckMuellerJobstetal., author = {R{\"u}ck, Thomas and M{\"u}ller, Max and Jobst, Simon and Weigl, Stefan and Pangerl, Jonas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Digital Twin of a Photoacoustic Trace Gas Sensor for Monitoring Methane in Complex Gas Compositions}, series = {Sensors and Actuators B: Chemical}, journal = {Sensors and Actuators B: Chemical}, number = {378}, doi = {10.1016/j.snb.2022.133119}, abstract = {The digitalization of industrial processes requires smart sensor systems. Photoacoustic spectroscopy is well suited for this purpose as it allows for small-sized and low-cost trace gas analysis. However, the method is susceptible to changes in measurement conditions and standard calibration routines often fail to correct for all changes. We therefore created a Digital Twin (DT) of a photoacoustic trace gas sensor for methane and evaluated it regarding variations in gas composition (CH4, N2, O2, CO2, H2O), temperature and pressure. With a mean absolute percentage error of 0.8 \% the accuracy of the sensor after DT compensation significantly exceeds the 24 \% achieved based on standard calibration in nitrogen. For the first time, we can fully analytically compute the photoacoustic signal under moderate ambient conditions with an error in the ppbV range by taking a holistic approach. Assuming knowledge of the underlying energy transfer processes, the model of this Digital Twin can be adapted to any microphone based photoacoustic sensor for monitoring any analyte species.}, language = {en} } @inproceedings{PangerlWittmannWeigletal., author = {Pangerl, Jonas and Wittmann, Elisabeth and Weigl, Stefan and M{\"u}ller, Max and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Using a Modulated Quantum Cascade Laser for Photoacoustic Spectra Recording of Exhaled Acetone and Main Breath Components}, series = {Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES)}, booktitle = {Optical Sensors and Sensing Congress 2022 (AIS, LACSEA, Sensors, ES)}, publisher = {Optica Publishing Group}, doi = {10.1364/AIS.2022.ATu3G.1}, abstract = {Photoacoustic spectra of main breath components together with acetone are presented demonstrating spectral linearity towards different concentrations and compositions. The acetone 3σ detection limit at 1209 cm-1 is 0.28 ppbV}, language = {en} } @inproceedings{MuellerDannerBreidbachetal., author = {M{\"u}ller, Stefan and Danner, Christian and Breidbach, J{\"o}rg and Seidl, Markus and Hußlein, Thomas and Lauf, Wolfgang}, title = {Stochastic Modeling of Throughput Times of Supplier Parts for an Automotive Plant}, series = {Angewandte Forschung in der Wirtschaftsinformatik - Prozesse, Technologie, Anwendungen, Systeme und Management 2014: Tagungsband zur 27. AKWI-Jahrestagung vom 07. bis zum 10.09.2014 an der Oberbayerischen Technischen Hochschule Regensburg}, booktitle = {Angewandte Forschung in der Wirtschaftsinformatik - Prozesse, Technologie, Anwendungen, Systeme und Management 2014: Tagungsband zur 27. AKWI-Jahrestagung vom 07. bis zum 10.09.2014 an der Oberbayerischen Technischen Hochschule Regensburg}, publisher = {News \& Media}, isbn = {978-3-936527-38-4}, doi = {10.15771/978-3-936527-38-4}, pages = {35 -- 43 S}, abstract = {For modern production industries optimized supply of parts is a critical success factor. Especially in the automotive industry, the reliable supply of painted bodies for the fi nal assembly is essential for OEMs considering just in time or just in sequence processes. Additionally one central cost target is the avoidance of resorting for JIT/JIS processes. An essential workfl ow analysis is therefore the basis for making strategic or operational decisions such as the adjustment of the plant structure or increasing the number of products and variants manufactured simultaneously. In order to support strategic planning using simulation and planning systems, the modeling of the production process is required. This is particularly important for scheduling as no real manufacturing data is available and therefore prognosis based on the model are essential. Due to the short time and the limited human resources for a detailed modeling, it is essential to create a robust model with good accuracy and reduced complexity}, language = {en} } @article{PangerlMoserMuelleretal., author = {Pangerl, Jonas and Moser, Elisabeth and M{\"u}ller, Max and Weigl, Stefan and Jobst, Simon and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A sub-ppbv-level Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor- Characterization and Multi-Component Spectra Recording in Synthetic Breath}, series = {Photoacoustics}, volume = {30}, journal = {Photoacoustics}, publisher = {Elsevier}, issn = {2213-5979}, doi = {10.1016/j.pacs.2023.100473}, pages = {1 -- 12}, abstract = {Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far.}, language = {en} } @incollection{WeiglMuellerPangerletal., author = {Weigl, Stefan and M{\"u}ller, Max and Pangerl, Jonas and R{\"u}ck, Thomas}, title = {Scopes and Limits of Photoacoustic Spectroscopy in Modern Breath Analysis}, series = {Breath Analysis}, booktitle = {Breath Analysis}, publisher = {Springer nature}, isbn = {978-3-031-18526-7}, doi = {10.1007/11663_2022_22}, pages = {101 -- 159}, abstract = {Photoacoustic spectroscopy is a viable tool for trace gas detection in various application fields. In recent years, this technique has been exploited more and more for modern breath analysis as well. Within this chapter, a holistic overview of photoacoustic spectroscopy is presented, while maintaining the relationship to breath analysis. Therefore, a concise description of the fundamentals of photoacoustic spectroscopy is provided. This is essential for understanding the scopes and limits of this outstanding measurement technique being described within this chapter. In the past several different types of photoacoustic measurement setups for trace gas detection have emerged, including different light sources, modulation techniques, and detection schemes. These are described shortly and advantages as well as disadvantages, especially in relation to breath analysis, are highlighted. Though being a promising sensor principle, measurement devices based on photoacoustic spectroscopy are still rare on the sensor market, especially when it comes to trace gas detection in complex gas matrices, e.g., human breath exhale. One main reason is due to possible molecular interactions influencing the relaxational behavior of the analyte altering the sensor signal. Recent results shedding light on the intricate relaxational processes within complex gas matrices are discussed in detail, providing approaches to overcome this issue. Finally, various applications of photoacoustic spectroscopy in breath analysis are described demonstrating the great potential of this technology.}, language = {en} } @unpublished{PangerlMoserMuelleretal., author = {Pangerl, Jonas and Moser, Elisabeth and M{\"u}ller, Max and Weigl, Stefan and Jobst, Simon and R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {A Highly Sensitive Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor: Characterization and Multi-Component Spectra Recording in Synthetic Breath}, series = {SSRN Electronic Journal}, journal = {SSRN Electronic Journal}, publisher = {Elsevier}, doi = {10.2139/ssrn.4305376}, abstract = {Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8260 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbV in terms of ethanol and 250 pptV regarding acetone, our system is among the best performing presented so far.}, language = {en} } @article{BeyerWeigertQuicketal., author = {Beyer, Thomas and Weigert, Markus and Quick, Harald H. and Pietrzyk, Uwe and Vogt, Florian and Palm, Christoph and Antoch, Gerald and M{\"u}ller, Stefan P. and Bockisch, Andreas}, title = {MR-based attenuation correction for torso-PET/MR imaging}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {35}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {6}, doi = {10.1007/s00259-008-0734-0}, pages = {1142 -- 1146}, abstract = {Purpose MR-based attenuation correction (AC) will become an integral part of combined PET/MR systems. Here, we propose a toolbox to validate MR-AC of clinical PET/MRI data sets. Methods Torso scans of ten patients were acquired on a combined PET/CT and on a 1.5-T MRI system. MR-based attenuation data were derived from the CT following MR-CT image co-registration and subsequent histogram matching. PET images were reconstructed after CT- (PET/CT) and MR-based AC (PET/MRI). Lesion-to-background (L/B) ratios were estimated on PET/CT and PET/MRI. Results MR-CT histogram matching leads to a mean voxel intensity difference in the CT- and MR-based attenuation images of 12\% (max). Mean differences between PET/MRI and PET/CT were 19\% (max). L/B ratios were similar except for the lung where local misregistration and intensity transformation leads to a biased PET/MRI. Conclusion Our toolbox can be used to study pitfalls in MR-AC. We found that co-registration accuracy and pixel value transformation determine the accuracy of PET/MRI.}, subject = {Kernspintomografie}, language = {en} } @article{WeigertPietrzykMuelleretal., author = {Weigert, Markus and Pietrzyk, Uwe and M{\"u}ller, Stefan P. and Palm, Christoph and Beyer, Thomas}, title = {Whole-body PET/CT imaging}, series = {Zeitschrift f{\"u}r Medizinische Physik}, volume = {18}, journal = {Zeitschrift f{\"u}r Medizinische Physik}, number = {1}, doi = {10.1016/j.zemedi.2007.07.004}, pages = {59 -- 66}, abstract = {Aim Combined whole-body (WB) PET/CT imaging provides better overall co-registration compared to separate CT and PET. However, in clinical routine local PET-CT mis-registration cannot be avoided. Thus, the reconstructed PET tracer distribution may be biased when using the misaligned CT transmission data for CT-based attenuation correction (CT-AC). We investigate the feasibility of retrospective co-registration techniques to align CT and PET images prior to CT-AC, thus improving potentially the quality of combined PET/CT imaging in clinical routine. Methods First, using a commercial software registration package CT images were aligned to the uncorrected PET data by rigid and non-rigid registration methods. Co-registration accuracy of both alignment approaches was assessed by reviewing the PET tracer uptake patterns (visual, linked cursor display) following attenuation correction based on the original and co-registered CT. Second, we investigated non-rigid registration based on a prototype ITK implementation of the B-spline algorithm on a similar targeted MR-CT registration task, there showing promising results. Results Manual rigid, landmark-based co-registration introduced unacceptable misalignment, in particular in peripheral areas of the whole-body images. Manual, non-rigid landmark-based co-registration prior to CT-AC was successful with minor loco-regional distortions. Nevertheless, neither rigid nor non-rigid automatic co-registration based on the Mutual Information image to image metric succeeded in co-registering the CT and noAC-PET images. In contrast to widely available commercial software registration our implementation of an alternative automated, non-rigid B-spline co-registration technique yielded promising results in this setting with MR-CT data. Conclusion In clinical PET/CT imaging, retrospective registration of CT and uncorrected PET images may improve the quality of the AC-PET images. As of today no validated and clinically viable commercial registration software is in routine use. This has triggered our efforts in pursuing new approaches to a validated, non-rigid co-registration algorithm applicable to whole-body PET/CT imaging of which first results are presented here. This approach appears suitable for applications in retrospective WB-PET/CT alignment. Ziel Kombinierte PET/CT-Bildgebung erm{\"o}glicht verbesserte Koregistrierung von PET- und CT-Daten gegen{\"u}ber separat akquirierten Bildern. Trotzdem entstehen in der klinischen Anwendung lokale Fehlregistrierungen, die zu Fehlern in der rekonstruierten PET- Tracerverteilung f{\"u}hren k{\"o}nnen, falls die unregistrierten CT-Daten zur Schw{\"a}chungskorrektur (AC) der Emissionsdaten verwendet werden. Wir untersuchen daher die Anwendung von Bildregistrierungsalgorithmen vor der CT-basierten AC zur Verbesserung der PET-Aufnahmen. Methoden Mittels einer kommerziellen Registrierungssoftware wurden die CT-Daten eines PET/CT- Tomographen durch landmarken- und intensit{\"a}tsbasierte rigide (starre) und nicht-rigide Registrierungsverfahren r{\"a}umlich an die unkorrigierten PET-Emissionsdaten angepasst und zur AC verwendet. Zur Bewertung wurden die Tracerverteilungen in den PET-Bildern (vor AC, CT-AC, CT-AC nach Koregistrierung) visuell und mit Hilfe korrelierter Fadenkreuze verglichen. Zus{\"a}tzlich untersuchten wir die ITK-Implementierung der bekannten B-spline basierten, nicht-rigiden Registrierungsans{\"a}tze im Hinblick auf ihre Verwendbarkeit f{\"u}r die multimodale PET/CT-Ganzk{\"o}rperregistrierung. Ergebnisse Mittels landmarkenbasierter, nicht-rigider Registrierung konnte die Tracerverteilung in den PET-Daten lokal verbessert werden. Landmarkenbasierte rigide Registrierung f{\"u}hrte zu starker Fehlregistrierung in entfernten K{\"o}rperregionen. Automatische rigide und nicht-rigide Registrierung unter Verwendung der Mutual-Information-{\"A}hnlichkeitsmetrik versagte auf allen verwendeten Datens{\"a}tzen. Die automatische Registrierung mit B-spline-Funktionen zeigte vielversprechende Resultate in der Anwendung auf einem {\"a}hnlich gelagerten CT-MR-Registrierungsproblem. Fazit Retrospektive, nicht-rigide Registrierung unkorrigierter PET- und CT-Aufnahmen aus kombinierten Aufnahmensystemen vor der AC kann die Qualit{\"a}t von PET-Aufnahmen im klinischen Einsatz verbessern. Trotzdem steht bis heute im klinischen Alltag keine validierte, automatische Registrierungssoftware zur Verf{\"u}gung. Wir verfolgen dazu Ans{\"a}tze f{\"u}r validierte, nicht-rigide Bildregistrierung f{\"u}r den klinischen Einsatz und pr{\"a}sentieren erste Ergebnisse.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @misc{BeyerWeigertPalmetal., author = {Beyer, Thomas and Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Vogt, Florian and Martinez, M.J. and Bockisch, Andreas}, title = {Towards MR-based attenuation correction for whole-body PET/MR imaging}, series = {The Journal of Nuclear Medicine}, volume = {47}, journal = {The Journal of Nuclear Medicine}, number = {Suppl. 1}, pages = {384P}, subject = {Kernspintomografie}, language = {en} } @misc{WeigertBeyerQuicketal., author = {Weigert, Markus and Beyer, Thomas and Quick, Harald H. and Pietrzyk, Uwe and Palm, Christoph and M{\"u}ller, Stefan P.}, title = {Generation of a MRI reference data set for the validation of automatic, non-rigid image co-registration algorithms}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A116}, subject = {Kernspintomografie}, language = {en} } @misc{WeigertPalmQuicketal., author = {Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Beyer, Thomas}, title = {Template for MR-based attenuation correction for whole-body PET/MR imaging}, series = {Nuklearmedizin}, volume = {46}, journal = {Nuklearmedizin}, number = {2}, pages = {A115}, subject = {Kernspintomografie}, language = {en} }