@misc{BroserFalterŁawrowskietal., author = {Broser, Christian and Falter, Thomas and Ławrowski, Robert Damian and Altenbuchner, Amelie and V{\"o}gele, Daniel and Koss, Claus and Schlamp, Matthias and Dunnweber, Jan and Steffens, Oliver and Heckner, Markus and Jaritz, Sabine and Schiegl, Thomas and Corsten, Sabine and Lauer, Norina and Guertler, Katherine and Koenig, Eric and Haug, Sonja and Huber, Dominik and Birkenmaier, Clemens and Krenkel, Lars and Wagner, Thomas and Justus, Xenia and Saßmannshausen, Sean Patrick and Kleine, Nadine and Weber, Karsten and Braun, Carina N. and Giacoppo, Giuliano and Heinrich, Michael and Just, Tobias and Schreck, Thomas and Schnabl, Andreas and Gilmore, Amador T{\´e}ran and Roeslin, Samuel and Schmid, Sandra and Wellnitz, Felix and Malz, Sebastian and Maurial, Andreas and Hauser, Florian and Mottok, J{\"u}rgen and Klettke, Meike and Scherzinger, Stefanie and St{\"o}rl, Uta and Heckner, Markus and Bazo, Alexander and Wolff, Christian and Kopper, Andreas and Westner, Markus and Pongratz, Christian and Ehrlich, Ingo and Briem, Ulrich and Hederer, Sebastian and Wagner, Marcus and Schillinger, Moritz and G{\"o}rlach, Julien and Hierl, Stefan and Siegl, Marco and Langer, Christoph and Hausladen, Matthias and Schreiner, Rupert and Haslbeck, Matthias and Kreuzer, Reinhard and Br{\"u}ckl, Oliver and Dawoud, Belal and Rabl, Hans-Peter and Gamisch, Bernd and Schmidt, Ottfried and Heberl, Michael and G{\"a}nsbauer, Bianca and Bick, Werner and Ellermeier, Andreas and Monkman, Gareth J. and Prem, Nina and Sindersberger, Dirk and Tschurtschenthaler, Karl and Aurbach, Maximilian and Dendorfer, Sebastian and Betz, Michael A. and Szecsey, Tamara and Mauerer, Wolfgang and Murr, Florian}, title = {Forschung 2018}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-9818209-5-9}, doi = {10.35096/othr/pub-1382}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-13826}, pages = {98}, subject = {Forschung}, language = {de} } @article{DeuterHajBrawanskietal., author = {Deuter, Daniel and Haj, Amer and Brawanski, Alexander and Krenkel, Lars and Schmidt, Nils Ole and Doenitz, Christian}, title = {Fast simulation of hemodynamics in intracranial aneurysms for clinical use}, series = {Acta Neurochirurgica}, volume = {167}, journal = {Acta Neurochirurgica}, publisher = {Springer}, doi = {10.1007/s00701-025-06469-9}, pages = {14}, abstract = {BACKGROUND: A widely accepted tool to assess hemodynamics, one of the most important factors in aneurysm pathophysiology, is Computational Fluid Dynamics (CFD). As current workflows are still time consuming and difficult to operate, CFD is not yet a standard tool in the clinical setting. There it could provide valuable information on aneurysm treatment, especially regarding local risks of rupture, which might help to optimize the individualized strategy of neurosurgical dissection during microsurgical aneurysm clipping. METHOD: We established and validated a semi-automated workflow using 3D rotational angiographies of 24 intracranial aneurysms from patients having received aneurysm treatment at our centre. Reconstruction of vessel geometry and generation of volume meshes was performed using AMIRA 6.2.0 and ICEM 17.1. For solving ANSYS CFX was used. For validational checks, tests regarding the volumetric impact of smoothing operations, the impact of mesh sizes on the results (grid convergence), geometric mesh quality and time tests for the time needed to perform the workflow were conducted in subgroups. RESULTS: Most of the steps of the workflow were performed directly on the 3D images requiring no programming experience. The workflow led to final CFD results in a mean time of 22 min 51.4 s (95\%-CI 20 min 51.562 s-24 min 51.238 s, n = 5). Volume of the geometries after pre-processing was in mean 4.46\% higher than before in the analysed subgroup (95\%-CI 3.43-5.50\%). Regarding mesh sizes, mean relative aberrations of 2.30\% (95\%-CI 1.51-3.09\%) were found for surface meshes and between 1.40\% (95\%-CI 1.07-1.72\%) and 2.61\% (95\%-CI 1.93-3.29\%) for volume meshes. Acceptable geometric mesh quality of volume meshes was found. CONCLUSIONS: We developed a semi-automated workflow for aneurysm CFD to benefit from hemodynamic data in the clinical setting. The ease of handling opens the workflow to clinicians untrained in programming. As previous studies have found that the distribution of hemodynamic parameters correlates with thin-walled aneurysm areas susceptible to rupture, these data might be beneficial for the operating neurosurgeon during aneurysm surgery, even in acute cases.}, language = {en} } @inproceedings{RuettenKrenkelQuadrio, author = {R{\"u}tten, Markus and Krenkel, Lars and Quadrio, Maurizio}, title = {Simulation and Analyis of the Unsteady Flow within Nasal Airways}, series = {9th European Congress on Computational Methods in Applied Sciences and Engineering - ECCOMAS Congress, 3-7 June 2024, Lisbon, Portugal}, booktitle = {9th European Congress on Computational Methods in Applied Sciences and Engineering - ECCOMAS Congress, 3-7 June 2024, Lisbon, Portugal}, language = {en} } @inproceedings{KrenkelWagnerWolfetal., author = {Krenkel, Lars and Wagner, Claus and Wolf, Ursula and Scholz, Alexander-Wigbert K. and Terekhov, Maxim and Rivoire, Julien and Schreiber, W.}, title = {Protective Artificial Lung Ventilation: Impact of an Endotracheal Tube on the Flow in a Generic Trachea}, series = {New Results in Numerical and Experimental Fluid Mechanics VII : Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008}, booktitle = {New Results in Numerical and Experimental Fluid Mechanics VII : Contributions to the 16th STAB/DGLR Symposium Aachen, Germany 2008}, editor = {Hirschel, Ernst Heinrich and Schr{\"o}der, Wolfgang and Fujii, Kozo and Haase, Werner and Leer, Bram and Leschziner, Michael A. and Pandolfi, Maurizio and Periaux, Jacques and Rizzi, Arthur and Roux, Bernard and Shokin, Yurii I. and Dillmann, Andreas and Heller, Gerd and Klaas, Michael and Kreplin, Hans-Peter and Nitsche, Wolfgang}, publisher = {Springer Berlin Heidelberg}, address = {Berlin, Heidelberg}, isbn = {978-3-642-14242-0}, doi = {10.1007/978-3-642-14243-7_62}, pages = {505 -- 512}, abstract = {Computational Fluid Dynamics (CFD) and experimental investigations on a generic model of the trachea have been carried out focusing on the impact of an endotracheal tube (ETT) on the resulting flow regime. It could be shown that detailed modelling of the airway management devices is essential for proper flow prediction, but secondary details as Murphy Eyes can be neglected. Models with bending and connector promote the formation of stronger secondary flows and disturbances which persist for a longer time.}, language = {en} } @misc{FriedrichRivoireScholzetal., author = {Friedrich, Janet and Rivoire, Julien and Scholz, Alexander-Wigbert K. and Wiegbert, and Terekov, Maxim and Kbrich, Rainer and Krenkel, Lars and Wagner, Claus and Schreiber, Laura Maria}, title = {Exploration of Gas Flow During High Frequency Oscillated Ventilation by 19F-Gas-MRI}, series = {Proceedings of the International Society for Magnetic Resonance in Medicine}, volume = {18}, journal = {Proceedings of the International Society for Magnetic Resonance in Medicine}, abstract = {To detect convective gas flow inside the large airways during high frequency oscillated ventilation (HFOV) the fluorinated contrast gas Heptafluoropropane was used for 19F-MRI. In a first study the comparison between constant flow measurements and Computational Fluid Dynamics (CFD) simulations provided a good agreement. In a following experiment oscillated flow was applied to a lung phantom consisting of ventilation bag and long pipe. The pressure wave inside the pipe was explored point-by-point and corresponding velocities were determined. With these experiments it could be shown for the first time that flow measurement during HFOV using fluorinated contrast gas is feasible.}, language = {en} } @misc{KreftingZaunsederSaeringetal., author = {Krefting, Dagmar and Zaunseder, Sebastian and S{\"a}ring, Dennis and Wittenberg, Thomas and Palm, Christoph and Schiecke, Karin and Krenkel, Lars and Hennemuth, Anja and Schnell, Susanne and Spicher, Nicolai}, title = {Blutdruck, H{\"a}modynamik und Gef{\"a}ßzustand: Innovative Erfassung und Bewertung - Schwerpunkt bildbasierte Verfahren}, series = {66. Jahrestagung der Deutschen Gesellschaft f{\"u}r Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform f{\"u}r die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online}, journal = {66. Jahrestagung der Deutschen Gesellschaft f{\"u}r Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform f{\"u}r die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online}, doi = {10.3205/21gmds016}, url = {http://nbn-resolving.de/urn:nbn:de:0183-21gmds0167}, abstract = {Einleitung: Blutdruck gilt als sogenannter Vitalparameter als einer der grundlegenden Indikatoren f{\"u}r den Gesundheitszustand einer Person. Sowohl zu niedriger als auch zu hoher Blutdruck kann lebensbedrohend sein, letzerer ist dar{\"u}ber hinaus ein Risikofaktor insbesondere f{\"u}r Herz-Kreislauferkrankungen, die trotz wichtiger Fortschritte in der Behandlung immer noch die h{\"a}ufigste Todesursache in Deutschland darstellen. Die H{\"a}modynamik, also die raumzeitliche Dynamik des Blutflusses, und der Gef{\"a}ßzustand sind eng verbunden mit dem Blutdruck und ebenfalls von hoher klinischer Relevanz, u.a. zur Identifikation von Durchblutungsst{\"o}rungen und ung{\"u}nstigen Druckverteilungen der Gef{\"a}ßwand. Innovationen in der Messtechnik als auch in der Datenanalyse bieten heute neue M{\"o}glichkeiten der Erfassung und Bewertung von Blutdruck, H{\"a}modynamik und Gef{\"a}ßzustand [1], [2], [3], [4]. Methodik: In einer gemeinsamen Workshopserie der AG Medizinische Bild- und Signalverarbeitung der GMDS und des Fachausschusses Biosignale der DGBMT werden wir neue Ans{\"a}tze und L{\"o}sungen f{\"u}r Mess- und Analyseverfahren zu Blutdruck und -fluss sowie zum Gef{\"a}ßzustand vorstellen und diskutieren. Dabei stehen im ersten Workshop auf der GMDS Jahrestagung Bildbasierte Verfahren im Zentrum, w{\"a}hrend der zweite Workshop auf der DGBMT Jahrestagung den Fokus auf Biosignalbasierten Verfahren legt. Es werden aktuelle Forschungsergebnisse vorgestellt und diskutiert. Es sind jeweils mehrere Vortr{\"a}ge geplant mit ausreichend Zeit zur Diskussion. Folgende Vortr{\"a}ge sind geplant (Arbeitstitel): Sebastian Zaunseder: Videobasierte Erfassung des Blutdrucks Anja Hennemuth: A Visualization Toolkit for the Analysis of Aortic Anatomy and Pressure Distribution Lars Krenkel: Numerische Analyse der Rupturwahrscheinlichkeit zerebraler Aneurysmata Susanne Schnell: Messung des Blutflusses und h{\"a}modynamischer Parameter mit 4D flow MRI: M{\"o}glichkeiten und Herausforderungen Ergebnisse: Ziel des Workshops ist die Identifikation von innovativen Ans{\"a}tzen und neuen Methoden zur qualitativen und quantitativen Bestimmung von h{\"a}modynamischen Parametern sowie deren kritische Bewertung durch die Community f{\"u}r die Eignung in der klinischen Entscheidungsunterst{\"u}tzung. Diskussion: Der Workshop leistet inhaltlich einen Beitrag zu zentralen Aspekten f{\"u}r die Herz-Kreislauf-Medizin. Er bringt dabei Expertise aus verschiedenen Bereichen zusammen und schl{\"a}gt die Br{\"u}cke zwischen Kardiologie, Medizininformatik und Medizintechnik. Schlussfolgerung: Innovative Technologien aus Medizintechnik und Informatik erm{\"o}glichen zunehmend einfache und raumzeitlich aufgel{\"o}ste Erfassung und Bewertung wichtiger Informationen zur Unterst{\"u}tzung von Diagnose und Therapieverfolgung. [1] Zaunseder S, Trumpp A, Wedekind D, Malberg H. Cardiovascular assessment by imaging photoplethysmography - a review. Biomed Tech (Berl). 2018 Oct 25;63(5):617-34. [2] Huellebrand M, Messroghli D, Tautz L, Kuehne T, Hennemuth A. An extensible software platform for interdisciplinary cardiovascular imaging research. Comput Methods Programs Biomed. 2020 Feb;184:105277. [3] Schmitter S, Adriany G, Waks M, Moeller S, Aristova M, Vali A, et al. Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T. Magn Reson Med. 2020 Oct;84(4):1947-60. [4] Birkenmaier C, and Krenkel, L. Flow in Artificial Lungs. In: New Results in Numerical and Experimental Fluid Mechanics XIII. Contributions to the 22nd STAB/DGLR Symposium. Springer; 2021.}, subject = {Blutdruck}, language = {de} } @article{LehlePhilippKrenkeletal., author = {Lehle, Karla and Philipp, Alois and Krenkel, Lars and Gruber, Michael and Hiller, Karl-Anton and M{\"u}ller, Thomas and Lubnow, Matthias}, title = {Thrombocytopenia During Venovenous Extracorporeal Membrane Oxygenation in Adult Patients With Bacterial, Viral, and COVID-19 Pneumonia}, series = {ASAIO Journal}, journal = {ASAIO Journal}, publisher = {Wolters Kluwer}, issn = {1058-2916}, doi = {10.1097/MAT.0000000000002383}, abstract = {Contact of blood with artificial surfaces triggers platelet activation. The aim was to compare platelet kinetics after venovenous extracorporeal membrane oxygenation (V-V ECMO) start and after system exchange in different etiologies of acute lung failure. Platelet counts and coagulation parameters were analyzed from adult patients with long and exchange-free (≥8 days) ECMO runs (n = 330) caused by bacterial (n = 142), viral (n = 76), or coronavirus disease 2019 (COVID-19) (n = 112) pneumonia. A subpopulation requiring a system exchange and with long, exchange-free runs of the second oxygenator (≥7 days) (n = 110) was analyzed analogously. Patients with COVID-19 showed the highest platelet levels before ECMO implantation. Independent of the underlying disease and ECMO type, platelet counts decreased significantly within 24 hours and reached a steady state after 5 days. In the subpopulation, at the day of a system exchange, platelet counts were lower compared with ECMO start, but without differences between underlying diseases. Subsequently, platelets remained unchanged in the bacterial pneumonia group, but increased in the COVID-19 and viral pneumonia groups within 2-4 days, whereas D-dimers decreased and fibrinogen levels increased. Thus, overall platelet counts on V-V ECMO show disease-specific initial dynamics followed by an ongoing consumption by the ECMO device, which is not boosted by new artificial surfaces after a system exchange.}, language = {en} } @article{BartschEigenbergerFelthausetal., author = {Bartsch, Alexander and Eigenberger, Andreas and Felthaus, Oliver and Booth, Brian W. and Krenkel, Lars and Schratzenstaller, Thomas and Prantl, Lukas}, title = {Quantification of Cannula Influence on Negative Pressure in Syringe Assisted Liposuction}, series = {Plastic \& Reconstructive Surgery}, journal = {Plastic \& Reconstructive Surgery}, publisher = {American Society of Plastic Surgeons}, issn = {0032-1052}, doi = {10.1097/PRS.0000000000012477}, abstract = {To make the results of the autologous fat transfer more satisfactory, all parameters of suction, preparation, and reapplication must be well understood. Since syringe-assisted liposuction is frequently used for small-volume procedures, we quantified the influence of the cannula on negative pressure. For these experiments, we used a digital manometer to which a syringe and one of seven different cannulas were connected. Data was collected and analyzed using LabVIEW and Matlab. The volume of our measurement setup was calculated using Boyle-Mariotte's law to ease interpretation, which revealed a volume of 2.82 ± 0.03 mL. We demonstrate that the volume of the measurement setup significantly affects the measurement results. Consequently, we accounted for this factor and calculated the theoretical values accordingly. Statistical analysis shows a significant influence on negative pressure across different cannulas, except for two pairs, which had minimal volume differences. Exemplary, for cannulas with volumes under 1.75 mL, a 2 mL syringe plunger pull was sufficient to create a - 0.5 bar (- 14.8 inHg) negative pressure. The present data indicate that the size of the suction cannula must be considered in syringe-assisted suction to ensure a specific negative pressure is not exceeded. Other research groups have demonstrated that adipocyte vitality and the amount of stromal vascular fraction are reduced by excessively strong negative pressure.}, language = {en} } @article{KranzWagnerPointneretal., author = {Kranz, Michael and Wagner, Maria Stella and Pointner, Daniel and Haus, Moritz and Lubnow, Matthias and Lehle, Karla and Krenkel, Lars}, title = {Polymer embedding of membrane lungs for histological investigations of intra-device clot formation}, series = {Cardiovascular Medicine}, volume = {13}, journal = {Cardiovascular Medicine}, publisher = {Frontiers}, address = {Lausanne}, doi = {10.3389/fcvm.2026.1650978}, pages = {21}, abstract = {Extracorporeal membrane oxygenation (ECMO) is an invasive but potentially lifesaving treatment option for severe cardiac or respiratory failure. Despite its beneficial effect, coagulation-related complications, mainly due to clot formation, excessive bleeding and the accumulation of deposits in the membrane lung (ML) remain common, causing higher mortality. In this context, the formation of clots and other deposits in the ML is of particular interest. Previous histological examinations of the polymethylpentene fiber mats inside the ML could only be performed in a top view, prohibiting valid quantification and examination of the multi-layered deposits or fiber mat spanning structures. Our objective was the establishment of a polymer embedding to increase the mechanical stability of the deposits and thus enable cross-sectional microtome cutting through the ML hollow-fibers. Clinically used MLs (PLS, Getinge, Rastatt, Germany) were stabilized with a polymer resin (HistoCURE 8100). Specimens were cut out of the embedded MLs and microtome sections with a thickness of 10 µm were performed. In addition to standard histological staining with hematoxylin-eosin (HE) and Pappenheim (May-Grunwald-Giemsa), fluorescence DNA staining for nucleated cells with 4′,6-diamidino-2-phenylindole (DAPI) and SYTOX™ Green as well as immunohistochemical and immunofluorescence staining for the lysosomal enzyme myeloperoxidase (MPO) and von Willebrand factor (vWF) were established. The protocol provides a method for large volume embedding (400 mL). The cellular and extracellular deposits were securely fixed by the polymer scaffold allowing the examination of clots in MLs in native position which was not possible with conventional paraffin embedding. Multi-layered deposits and fiber mat spanning structures are no longer disrupted during specimen extraction and can now be quantified. Staining with HE, Pappenheim, DAPI, SYTOX™ Green, MPO, and vWF was successfully tested with this protocol. This method may be the foundation for new insights into the complex clotting phenomena observed in MLs}, language = {en} } @misc{MichelKrenkel, author = {Michel, Johanna and Krenkel, Lars}, title = {Experimental Investigation of Shear-Induced Generation of Respiratory Aerosol: Simultaneous Measurements of Particle Quantities and Wave Topology}, series = {2nd European Fluid Dynamics Conference (EFDC2), 26-29 August 2025, Dublin, Ireland}, journal = {2nd European Fluid Dynamics Conference (EFDC2), 26-29 August 2025, Dublin, Ireland}, doi = {10.35096/othr/pub-8859}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-88593}, pages = {1}, abstract = {Despite the high level of attention on infectious respiratory aerosol during the Covid19 pandemic, little is known about the processes how these particles form inside the respiratory system. Understanding the underlying fluid mechanical processes and their influencing factors would enable the development of drugs to suppress the generation of infectious aerosol. In the proposed work, we focus on the shear-induced mechanism of aerosol generation, which is supposed to occur mostly in the larger airways during coughing. In this process, high air velocities trigger Kelvin-Helmholtz waves in the mucus film, which lines the air vessels. Through a series of instabilities, particles detach from the crest of these waves. In the proposed work, we investigate the process of shear-induced aerosol generation in idealized experiments where we vary the air-flow characteristics and the properties of the mucus fluid. Our central aim here is to deduct an empirical model of the quantity and size distribution of generated particles depending on the mucus rheology and the local shear flow. Further, we observe the wave topology to better understand the coupling between the air flow and the waves. In our experimental setup, we measure the quantity of created particles and the emerging waves simultaneously. To ensure controllable conditions, we simplify the complex flow conditions in the airways. We use a rectangular channel with the bottom wall covered in a mucus mimetic. The mucus mimetic fluid is a synthetic hydrogel developed to recreate the viscoelastic properties and low surface tensions of the mucus. Filtered pressurized air is guided through the channel to trigger shear-induced aerosol generation. After passing the mucus mimetic, the air enters into a collection chamber from where particles are sampled continuously by an aerosol spectrometer. To measure wave topology, we use planar laser induced fluorescence. For this, we stain the mucus mimetic with fluorescent dyes and illuminate a line on the surface of the fluid film with a 532 nm laser. A high-resolution camera captures the resulting fluorescent glow of the mucus mimetic. Figure 1 presents exemplary wave topology results from the experiments, employing varying air flow volume rates, mucus mimetic gel properties, and different configurations of the laser and camera. The resulting wave topologies exhibit significant variation. For the conference, we will conduct parameter studies of the particle quantities and wave topology while varying the mucus mimetic properties and the flow rate of the air. Additionally, we will present grid projection-based techniques to extend the single-line wave measurements and asses the entire surface of the mucus film.}, language = {en} } @inproceedings{KranzPointnerWagneretal., author = {Kranz, Michael and Pointner, Daniel and Wagner, Maria Stella and Lubnow, Matthias and Lehle, Karla and Krenkel, Lars}, title = {High-Resolution Flow Investigations in Membrane-Lungs for Understanding Shear-Induced Blood Clot Formation}, series = {New Results in Numerical and Experimental Fluid Mechanics XV : Contributions to the 24th STAB/DGLR Symposium, Regensburg, Germany, 2024}, booktitle = {New Results in Numerical and Experimental Fluid Mechanics XV : Contributions to the 24th STAB/DGLR Symposium, Regensburg, Germany, 2024}, editor = {Dillmann, Andreas and Heller, Gerd and Kr{\"a}mer, Ewald and Breitsamter, Christian and Wagner, Claus and Krenkel, Lars}, publisher = {Springer}, address = {Cham}, doi = {10.1007/978-3-032-11115-9_12}, pages = {125 -- 134}, abstract = {Complex blood flow phenomena in membrane lungs (MLs) play a crucial role in intra-device clot formation and the occurrence of thromboembolic events. At present, however, the local flow conditions within an ML are not yet sufficiently known. The aim was to gain a deeper understanding of local flow regimes inside MLs by performing highly resolved computational fluid dynamics (CFD) of generic and native fiber mat bundles. Straight cylinders with a diameter of 380 μm in parallel arrangement were the foundation of the generic model. For validation, a method for reconstructing a native geometry from a microcomputed tomography (μCT) scan was established, with both models used for CFD. While the generic model showed a symmetrical flow regime without indicating any pathological flow, the native model did show an irregular fiber arrangement and no symmetrical flow regime. In conclusion, the fiber arrangement significantly affects the local flow regimes inside MLs.}, language = {en} } @misc{KranzPointnerLehleetal., author = {Kranz, Michael and Pointner, Daniel and Lehle, Karla and Lubnow, Matthias and Krenkel, Lars}, title = {High-resolution flow field investigations in membrane lungs, considering the complex blood rheology}, series = {1st European Fluid Dynamics Conference (EFDC1), 16-20.September 2024, Aachen}, journal = {1st European Fluid Dynamics Conference (EFDC1), 16-20.September 2024, Aachen}, doi = {10.35096/othr/pub-8921}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-89214}, pages = {2}, abstract = {Despite major improvements over the last years, coagulative disorders and clotting phenomena in membrane lungs (MLs) are still considerable complications in extracorporeal membrane oxygenation (ECMO). ECMO is an increasingly used treatment for patients with severe respiratory failure or cardiac arrest [1]. For both, evaluation of therapeutic decisions and fundamental research on patient specific intra-device clotting phenomena, the direct visualization and analysis of clot formation in combination with a detailed flow field correlation is highly desirable and therefore an intensively followed research topic. Modelling blood flow and shear induced coagulation in MLs is challenging. The relevant geometry of oxygenator fibers and chaining threads is complex and spans several length scales. In relevant scales and regimes, blood shows several significant non-Newtonian effects. Viscosity impacts shear rate, which is important in several coagulation mechanisms. Additionally, coagulation processes are influencing fluid properties and geometry significantly. Existing approaches of previous research work are only able to consider some, but not all relevant effects and geometrical details. Due to the enormous size of the discretized geometries, highly detailed viscosity and coagulations models are not applicable. Our goal is to develop a model for combined viscosity and coagulation properties of blood flow in MLs. In our work, we compare the influence of different levels of detail of the ML geometry as well as the influence of considering realistic blood flow behavior (viscosity change by considering the local hematocrit distribution within the F{\aa}hraeus-Lindqvist-Effect) on the resulting flow field in relevant subsections of a ML. High-resolution micro-CT geometry reconstructions [1] are compared to idealized generic fiber representations. For realistic blood flow modelling, Newtonian representation is compared to the established Carreau-Yasuda and a multiphase Euler-Euler approach. Results are presented for relevant subsections as well as for the complete ML.}, language = {en} } @misc{KranzWagnerPointneretal., author = {Kranz, Michael and Wagner, Maria Stella and Pointner, Daniel and Waldbauer, Selina and M{\"u}ller, Thomas and Lubnow, Matthias and Foltan, Maik and Krenkel, Lars and Lehle, Karla}, title = {Polymeric Embedding of Membrane Lungs: A Novel Method for Histological Investigations of Intra-Device Clot Formation}, series = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, journal = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, language = {en} } @misc{KranzWagnerKrenkeletal., author = {Kranz, Michael and Wagner, Maria Stella and Krenkel, Lars and M{\"u}ller, Thomas and Lubnow, Matthias and Philipp, Alois and Lehle, Karla}, title = {Clot Localization within Membrane Lungs using different Imaging Methods and Histological Clot Characterization as a way to prevent Thrombosis in Extracorporeal Membrane Oxygenation}, volume = {2023}, language = {en} } @misc{KoesterKranzWagneretal., author = {K{\"o}ster, Leonie and Kranz, Michael and Wagner, Maria Stella and Foltan, Maik and M{\"u}ller, Thomas and Lubnow, Matthias and Krenkel, Lars and Lehle, Karla}, title = {Histological Investigations of Intra-Device Clot Formation in ECMO Pumps}, series = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, journal = {12th EuroELSO Congress, 24-27. April 2024, Krakow}, language = {en} }