@article{HornbergerWitteHortetal., author = {Hornberger, Helga and Witte, Frank and Hort, Norbert and M{\"u}ller, Wolf-Dieter}, title = {Effect of fetal calf serum on the corrosion behaviour of magnesium alloys}, series = {Materials Science and Engineering B}, volume = {176}, journal = {Materials Science and Engineering B}, number = {29}, doi = {10.1016/j.mseb.2011.07.018}, pages = {1746 -- 1755}, abstract = {The corrosion behaviour of WE43 magnesium alloys using the mini cell system was studied. Voltammetry and impedance spectroscopy were applied to study on the one hand the effect of microstructure of the working electrode and on the other hand the effect of proteins in the electrolyte. Two types of alloy samples were produced (i) by permanent mould casting and (ii) by gas atomization followed by extrusion. The results showed that the microstructure was strongly influenced by the production process. The extruded samples showed an improved homogeneity of phase distribution compared with cast samples as it was aimed for. Due to increased homogeneity it was expected to find higher corrosion resistance. However, the electrochemical results are contradictory and suggest an additional phase in the extruded microstructure. Using energy dispersive X-ray spectroscopy (EDX) the secondary magnesium rare earths (RE) phase of extruded samples showed differing composition than of cast samples as well as additional oxide phases. After the samples were electrochemically investigated in cell medium with and without fetal calf serum (FCS), an impact of FCS was detected in voltammetry due to the length of the polarisation curve. As the tip of the mini cell in contact with the working electrode is small, developing gases tend to spread on the working electrode and break the contact of liquid to the counter electrode; which results in disrupting the current flow. This effect was more pronounced when rising the voltage and was found reduced when using electrolytes with FCS. Impedance spectra were slightly deformed by FCS, seen as a kinetic effect but not as a basic differing corrosion reaction. The insight into the effects of FCS was provided by the mini cell system as this system enables to collect entire series of measurements. In contrast of two single measurements, those series reflected the slight difference caused by FCS. The focus of the electrochemical corrosion study was set on the first half hour of immersion.}, language = {en} } @article{HornbergerStrieglTrahanofskyetal., author = {Hornberger, Helga and Striegl, Birgit and Trahanofsky, M. and Kneissl, F. and Kronseder, Matthias}, title = {Degradation and bioactivity studies of Mg membranes for dental surgery}, series = {Materials Letter X}, volume = {2}, journal = {Materials Letter X}, number = {June}, publisher = {Elsevier}, doi = {10.1016/j.mlblux.2019.100007}, pages = {1 -- 5}, abstract = {Bioresorbable materials are under investigation due to their promising properties for applications as implant material. This study is about the degradation and bioactivity behaviour of magnesium foils, which allegorize dental membranes. The degradation behaviour including pitting corrosion during immersion tests can be precisely observed using micro-computed tomography. Using the bioactivity test according to Kokubo, it is shown that magnesium has strong Ca-phosphate layer formation correlated with high degradation. Therefore, magnesium foils appear to hold a great potential for bone implant application.}, language = {en} } @article{GebhardtSeussTurhanetal., author = {Gebhardt, F. and Seuss, Sigrid and Turhan, Metehan C. and Hornberger, Helga and Virtanen, Sannakaisa and Boccaccini, Aldo R.}, title = {Characterization of electrophoretic chitosan coatings on stainless steel}, series = {Materials Letters}, volume = {66}, journal = {Materials Letters}, number = {1}, doi = {10.1016/j.matlet.2011.08.088}, pages = {302 -- 304}, abstract = {Electrophoretic chitosan deposits on stainless steel AISI 316 L were produced and characterized. The coating quality (thickness, defectiveness, corrosion protection ability) was seen to depend on the electric field used for EPD. Corrosion studies in concentrated simulated body fluid (SBF5) demonstrated that the surface characteristics of AISI 316 L can be positively influenced by the chitosan coating.}, language = {en} } @article{HornbergerVirtanenBoccaccini, author = {Hornberger, Helga and Virtanen, Sannakaisa and Boccaccini, Aldo R.}, title = {Biomedical coatings on magnesium alloys}, series = {Acta Biomaterialia}, volume = {8}, journal = {Acta Biomaterialia}, number = {7}, doi = {10.1016/j.actbio.2012.04.012}, pages = {2442 -- 2455}, abstract = {This review comprehensively covers research carried out in the field of degradable coatings on Mg and Mg alloys for biomedical applications. Several coating methods are discussed, which can be divided, based on the specific processing techniques used, into conversion and deposition coatings. The literature review revealed that in most cases coatings increase the corrosion resistance of Mg and Mg alloys. The critical factors determining coating performance, such as corrosion rate, surface chemistry, adhesion and coating morphology, are identified and discussed. The analysis of the literature showed that many studies have focused on calcium phosphate coatings produced either using conversion or deposition methods which were developed for orthopaedic applications. However, the control of phases and the formation of cracks still appear unsatisfactory. More research and development is needed in the case of biodegradable organic based coatings to generate reproducible and relevant data. In addition to biocompatibility, the mechanical properties of the coatings are also relevant, and the development of appropriate methods to study the corrosion process in detail and in the long term remains an important area of research.}, language = {en} } @article{ManarancheHornberger, author = {Manaranche, Claire and Hornberger, Helga}, title = {A proposal for the classification of precious dental alloys according to their resistance to corrosion based on the iso 10271 standard}, series = {European Cells and Materials}, volume = {5}, journal = {European Cells and Materials}, number = {SUPPL. 1}, publisher = {Univ. of Wales}, address = {Aberystwyth, Wales}, pages = {34 -- 36}, abstract = {A lot of dental alloys are available on the market. Among these alloys, there are the conventional alloys, the so called casting alloys used without ceramics, the bonding alloys used with high fusing ceramics and the universal alloys used without or with low fusing ceramics. It is im portant to know the physical and mechanical properties of these materials but also their biocompatibility and their resistance to corrosion. Dental alloys are generally placed in the mouth for many years, they must not induce adverse biological reactions such as gingival swelling and erythema, mucosal pain and lichenoid reactions. Although these troubles are often caused not by the materials itself (1, 2), they can be induced by the metallic ions released during their corrosion. In order to decrease the risks to the health, it is necessary to study the corrosion of the dental alloys. Currently, the ISO 10271 Standard (3), describes 3 different corrosion tests: a static immersion test (chemical corrosion), an electrochemic al test and a tarnish test. However, there are no indications yet about the possible interpretation of test results. In this paper, we propose a method to compare and classify the dental alloys in relation to their chemical and electrochemical corrosion results. METHODS: The material tested are pure metals such as gold, palladium, silver, copper and zinc as well as dental alloys which are commercially sold (see Table 1). 54 different materials have been tested. A minimum of four samples of each material were tested by electrochemic al corrosio n and a minimum of three in chemical test. The samples were cast and prepared as indicated by the manufacturer and by the ISO 10271. For the electrochemical test, the samples are in the form of disks 11 mm in diameter. They are tested with a potentiostat/galvanostat Voltalab Model 21. For the chemical test, the samples are rectangular with the dimensions 35X10X1.7 mm. The solution used and the operating conditions are described in the ISO 10271. The concentration of metallic ions released is measured by Induced Coupled Plasma}, language = {en} } @article{ManarancheHornberger, author = {Manaranche, Claire and Hornberger, Helga}, title = {A proposal for the classification of dental alloys according to their resistance to corrosion}, series = {Dental Materials}, volume = {23}, journal = {Dental Materials}, number = {11}, doi = {10.1016/j.dental.2006.11.030}, pages = {1428 -- 1437}, abstract = {Objectives The purpose of this study was to establish a method to compare and classify dental alloys in relation to their resistance to corrosion. Methods Alloy samples and pure metal samples were prepared and tested in chemical and electrochemical corrosion according to ISO 10271. For electrochemical test, the rest potential versus time and a potentiodynamic scan were recorded. After chemical corrosion test, the ions released were analyzed by ICP (induced coupled plasma) spectroscopy. Results High gold alloys had a similar polarization curve than gold. The same effect was observed for Pd-base alloys, their curves were similar to the one of palladium. The ions released during chemical corrosion were non-precious metallic ions. Thereby Ni-Cr alloys were found to release the most ions. Au-Pt alloys showed the highest release of ions compared with other precious alloys but low compared with Ni-Cr. Electrochemical corrosion was more aggressive than chemical corrosion and every type of elements was etched, the higher the precious metal content, the higher the resistance to corrosion of the alloy. Discussion Using the recorded data, a classification system for electrochemical corrosion was developed and discussed to judge the results. Hereby were gold and zinc used as reference materials. The applied classification system defines five classes and it is proposed that alloys of class V are not acceptable. For chemical corrosion resistance, three classes were distinguished according to the quantity of metallic ions released and it is proposed that class III (100-1000 μg/cm2 week) is not acceptable. Palladium and Pd-base alloys showed a higher electrochemical and chemical corrosion resistance than gold.}, language = {en} }