@inproceedings{HoellerZeitler, author = {H{\"o}ller, Christoph and Zeitler, Berndt}, title = {Playing ball with transients on the force plate and on the reception plate}, series = {Noise control for a better environment. PROCEEDINGS OF INTERNOISE 2019. The 48th International Congress and Exhibition on Noise Control Engineering, June 16-19, Madrid}, booktitle = {Noise control for a better environment. PROCEEDINGS OF INTERNOISE 2019. The 48th International Congress and Exhibition on Noise Control Engineering, June 16-19, Madrid}, publisher = {INTERNATIONAL INSTITUTE OF NOISE CONTROL ENGINEERING}, language = {en} } @inproceedings{HoellerZeitlerReinholdetal., author = {H{\"o}ller, Christoph and Zeitler, Berndt and Reinhold, S. and Jakob, A. and Hopkins, C.}, title = {Charakterisierung von K{\"o}rperschallquellen auf der Empfangsplatte mit Hilfe von orthogonalen Funktionen}, series = {Tagungsband - DAGA 2019 : 45. Jahrestagung f{\"u}r Akustik : 18.-21. M{\"a}rz 2019, Rostock}, booktitle = {Tagungsband - DAGA 2019 : 45. Jahrestagung f{\"u}r Akustik : 18.-21. M{\"a}rz 2019, Rostock}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, address = {Berlin}, isbn = {978-3-939296-14-0}, pages = {93 -- 96}, language = {de} } @inproceedings{HoellerZeitlerSchneideretal., author = {H{\"o}ller, Christoph and Zeitler, Berndt and Schneider, M. and Schanda, U.}, title = {Tieffrequenter Trittschall - Stand der Wissenschaft und Technik}, series = {Fortschritte der Akustik - DAGA 2020 : 46. Deutsche Jahrestagung f{\"u}r Akustik}, booktitle = {Fortschritte der Akustik - DAGA 2020 : 46. Deutsche Jahrestagung f{\"u}r Akustik}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, language = {de} } @inproceedings{HoellerBloedt, author = {H{\"o}ller, Christoph and Bl{\"o}dt, Adrian}, title = {Messung und Bewertung von elastischen Bodenbel{\"a}gen auf tief abgestimmten schwimmenden Estrichen in Fitnessstudios}, series = {Tagungsband DAGA 2021: 47. Jahrestagung f{\"u}r Akustik, 15.-18. August 2021, Wien und Online}, booktitle = {Tagungsband DAGA 2021: 47. Jahrestagung f{\"u}r Akustik, 15.-18. August 2021, Wien und Online}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, address = {Berlin}, language = {de} } @techreport{HoellerQuirtMahnetal., author = {H{\"o}ller, Christoph and Quirt, J. David and Mahn, Jeffrey and M{\"u}ller-Trapet, Markus}, title = {Guide to calculating airborne sound transmission in buildings}, edition = {5th edition}, publisher = {National Research Council of Canada. Construction}, doi = {10.4224/40001814}, abstract = {In recent years, the science and engineering for controlling sound transmission in buildings have shifted from a focus on individual assemblies such as walls or floors, to a focus on performance of the complete system. Standardized procedures for calculating the overall transmission, combined with standardized measurements to characterize sub-assemblies, provide much better prediction of sound transmission between adjacent indoor spaces. The International Standards Organization (ISO) has published a calculation method, ISO 15712-1 that uses laboratory test data for sub-assemblies such as walls and floors as inputs for a detailed procedure to calculate the expected sound transmission between adjacent rooms in a building. This standard works very well for some types of construction, but to use it in a North American context one must overcome two obstacles - incompatibility with the ASTM standards used by our construction industry, and low accuracy of its predictions for lightweight wood or steel frame construction. To bypass limitations of ISO 15712-1, this Guide explains how to merge ASTM and ISO test data in the ISO calculation procedure, and provides recommendations for applying extended measurement and calculation procedures for specific common types of construction. This Guide was developed in a project established by the National Research Council of Canada to support the transition of construction industry practice to using apparent sound transmission class (ASTC) for sound control objectives in the National Building Code of Canada (NBCC). However, the potential range of application goes beyond the minimum requirements of the NBCC - the Guide also facilitates design to provide enhanced sound insulation, and should be generally applicable to construction in both Canada and the USA. This publication contains a limited set of examples for several types of construction, to provide an introduction and overview of the ASTC calculation procedure. Additional examples and measurement data can be found in the companion documents to this Guide, namely NRC Research Reports RR-333 to RR-337. Furthermore, the calculation procedure outlined and illustrated in this Guide is also used by the software web application soundPATHS, which is available for free on the website of the National Research Council of Canada (see the references in Section 7 of this Guide for access details). Au cours des derni{\`e}res ann{\´e}es, les scientifiques et les ing{\´e}nieurs ont fait porter leurs efforts en mati{\`e}re d'att{\´e}nuation de la transmission du son dans les b{\^a}timents davantage sur le rendement du syst{\`e}me dans sa totalit{\´e} que sur les ensembles de construction individuels. Les m{\´e}thodes normalis{\´e}es de calcul de la transmission globale, combin{\´e}es {\`a} des mesures normalis{\´e}es de caract{\´e}risation des sous-ensembles, permettent de mieux pr{\´e}dire la transmission du son entre des espaces int{\´e}rieurs adjacents. L'Organisation internationale de normalisation (ISO) a publi{\´e} une m{\´e}thode de calcul, la norme ISO 15712-1, qui utilise des donn{\´e}es d'essai en laboratoire pour les sous-ensembles, comme les murs et les planchers, comme donn{\´e}es d'entr{\´e}e en vue d'une m{\´e}thode d{\´e}taill{\´e}e de calcul de la transmission du son pr{\´e}vue entre des pi{\`e}ces adjacentes dans un b{\^a}timent. Cette norme fonctionne tr{\`e}s bien pour certains types de construction, mais pour l'utiliser dans un contexte nord-am{\´e}ricain, il faut surmonter deux obstacles - l'incompatibilit{\´e} avec les normes ASTM utilis{\´e}es par notre industrie de la construction et la faible exactitude de ses pr{\´e}visions pour la construction {\`a} ossature de bois ou d'acier l{\´e}g{\`e}re. Pour contourner les limites de la norme ISO 15712-1, le pr{\´e}sent guide explique comment fusionner les donn{\´e}es d'essai de l'ISO et de l'ASTM dans la m{\´e}thode de calcul de l'ISO, et formule des recommandations relativement {\`a} l'application de m{\´e}thodes {\´e}largies de mesure et de calcul pour des types de construction courants. Le pr{\´e}sent guide a {\´e}t{\´e} {\´e}labor{\´e} dans le cadre d'un projet mis sur pied par le Conseil national de recherches du Canada afin d'appuyer la transition de la pratique de l'industrie de la construction vers l'utilisation d'un indice de transmission du son apparent (ITSA) satisfaisant aux objectifs de r{\´e}duction rigoureux du Code national du b{\^a}timent du Canada (CNBC). Toutefois, l'{\´e}ventail potentiel d'applications va au-del{\`a} des exigences minimales du CNBC - le Guide facilite aussi une conception visant {\`a} am{\´e}liorer l'insonorisation et devrait s'appliquer de fa{\c{c}}on g{\´e}n{\´e}rale {\`a} la construction tant au Canada qu'aux {\´E}tats-Unis. La pr{\´e}sente publication contient un ensemble limit{\´e} d'exemples pour plusieurs types de construction, afin de fournir une introduction et un aper{\c{c}}u de la m{\´e}thode de calcul de l'ITSA. On trouvera d'autres exemples et donn{\´e}es de mesure dans les documents d'accompagnement du pr{\´e}sent guide, {\`a} savoir, les rapports de recherche RR-333 {\`a} RR-337 du CNRC. De plus, la m{\´e}thode de calcul d{\´e}crite et illustr{\´e}e dans le pr{\´e}sent guide est {\´e}galement utilis{\´e}e par l'application Web soundPATHS, disponible gratuitement sur le site Web du Conseil national de recherches du Canada (voir les r{\´e}f{\´e}rences {\`a} la section 7 du pr{\´e}sent guide pour les d{\´e}tails d'acc{\`e}s).}, language = {en} } @techreport{HoellerZeitlerSabourin, author = {H{\"o}ller, Christoph and Zeitler, Berndt and Sabourin, Ivan}, title = {Airborne and impact sound insulation data for cold-formed steel-framed walls and floors}, publisher = {National Research Council of Canada. Construction}, doi = {10.4224/23002823}, abstract = {This report presents the results of an extensive series of direct sound insulation tests of cold-formed steel-framed walls and floors. The direct airborne sound insulation of 30 walls with cold-formed steel framing was measured in accordance with ASTM E90-09. The walls had steel studs with a depth of 92 mm (3-5/8") or 152 mm (6"), and with a steel thickness of 1.09 mm (0.043") or 1.37 mm (0.054"). Other parameters that were investigated included the number of layers and thickness of gypsum board, the cavity insulation, the stud spacing, and the use of resilient channels. The test results for some non-standard wall configurations that were tested for research purposes (e.g. for walls with gypsum board on one side only) are also included in this report. The direct airborne and impact sound insulation of 17 floors with cold-formed steel framing was measured in accordance with ASTM E90-09 and ASTM E492-09, respectively. The floors had steel joists with a depth of 254 mm (10") or 317 mm (12.5"), and with a steel thickness of 1.37 mm (0.054"). The top surface of the floor/ceiling assemblies was composed of a corrugated steel deck with poured gypsum concrete, while the bottom surface was composed of a gypsum board ceiling on resilient channels. The influence of the joist depth and the number of layers and thickness of the ceiling gypsum board was investigated, as well as the influence of several floor coverings (e.g. laminate or carpet). The report presents the detailed specimen descriptions and specimen properties and the results from the standardized tests according to ASTM E90-09 and ASTM E492-09. Brief analyses of the parameters affecting the sound insulation of the steel-framed assemblies are provided. The tests presented in this report were part of a large research study that also included an investigation into the flanking sound transmission in cold-formed steel-framed buildings. The results of that study are described in the NRC Research Report RR-337, "Apparent Sound Insulation in Cold-Formed Steel-Framed Buildings" [1]. The NRC Research Report RR-337 also includes some of the airborne sound insulation results presented here, albeit without listing the detailed specimen descriptions and specimen properties that are provided in this report.}, language = {en} } @article{HoellerGibbs, author = {H{\"o}ller, Christoph and Gibbs, Barry M.}, title = {Indirect determination of the mobility of structure-borne sound sources}, series = {Journal of Sound and Vibration}, volume = {344}, journal = {Journal of Sound and Vibration}, publisher = {Elsevier}, doi = {10.1016/j.jsv.2015.01.011}, pages = {38 -- 58}, abstract = {Methods are considered for the indirect determination of the mobility of structure-borne sound sources. Instead of performing measurements on the source in the free state, the source mobility is obtained from measurements made in-situ. This approach is beneficial if the source is difficult to suspend, or if it contains nonlinear structural elements. Two formulations for an indirect source mobility are derived theoretically. The first requires measurement of velocities at or near to the contact points. The second involves measurement of remote velocities only. Neither of the methods requires excitation at the contacts in the coupled state. Numerical simulations of coupled beams are used to validate the two methods and investigate their accuracy and reliability with respect to typical measurement errors, such as background noise and inaccuracies in sensor positioning. It is found that these can have a significant effect on the methods considered. Several experimental case studies with single-contact and multi-contact sources are performed. The results confirm the validity of the two methods in principle, but highlight their sensitivity to experimental errors. In a representative case study with a fan unit, average errors range between ±5 dB and ±10 dB, with occasional errors of up to 30 dB.}, language = {de} } @techreport{HoellerMahnQuirtetal., author = {H{\"o}ller, Christoph and Mahn, Jeffrey and Quirt, David and Schoenwald, Stefan and Zeitler, Berndt}, title = {Apparent sound insulation in cross-laminated timber buildings}, publisher = {National Research Council of Canada. Construction}, doi = {10.4224/23002009}, pages = {116}, abstract = {This Report presents the results from experimental studies of airborne sound transmission, together with an explanation of calculation procedures to predict the apparent airborne sound transmission between adjacent spaces in a building whose construction is based on cross-laminated timber (CLT) panels. There are several types of CLT constructions which are commercially available in Canada, but this study only focused on CLT panels that have adhesive between the faces of the timber elements in adjacent layers, but no adhesive bonding the adjacent timber elements within a given layer. There were noticeable gaps (up to 3 mm wide) between some of the timber elements comprising each layer of the CLT assembly. These CLT panels could be called "Face-Laminated CLT Panels" but are simply referred to as CLT panels in this Report. Another form of CLT panels has adhesive between the faces of the timber elements in adjacent layers as well as adhesive to bond the adjacent timber elements within a given layer. These are referred to as "Fully-Bonded CLT Panels" in this Report. Because fully-bonded CLT panels have different properties than face-laminated CLT panels, the sound transmission data and predictions in this Report do not apply to fully-bonded CLT panels.}, language = {en} } @article{HoellerGibbs, author = {H{\"o}ller, Christoph and Gibbs, Barry M.}, title = {Inverse Method to Obtain Blocked Forces of Vibrating Sound Sources in Buildings}, series = {Acta Acustica united with Acustica}, volume = {103}, journal = {Acta Acustica united with Acustica}, number = {4}, publisher = {ingenta}, doi = {10.3813/AAA.919092}, pages = {639 -- 649}, abstract = {Vibrating sources, such as building service equipment, are major contributors to noise in buildings. In order to predict and subsequently reduce the sound pressure levels generated by these devices, it is necessary to first predict the total vibrational power injected by them into the supporting building structure. Whilst simplified methods are available for the calculation of the total power through all contacts, it would be beneficial to have more detailed knowledge of the dominant contact powers. For sources on low-mobility building elements, the contact powers are determined by the blocked force, along with the real part of the receiver mobility at each contact. This paper describes a novel inverse method to obtain the blocked forces at each contact. The method employs an instrumented reception plate, which is numerically modelled to allow optimum accelerometer positions to be selected, for any source and any location. The underlying theory and measurement procedure are described, and experimental validations are presented.}, language = {en} } @techreport{HoellerQuirtZeitleretal., author = {H{\"o}ller, Christoph and Quirt, David and Zeitler, Berndt and Sabourin, Ivan}, title = {Apparent sound insulation in cold-formed steel-framed buildings}, publisher = {National Research Council of Canada. Construction}, doi = {10.4224/23001843}, abstract = {This Report presents the results from substantial experimental studies of sound transmission, together with an explanation of calculation procedures to predict the sound transmission between adjacent spaces in a building whose walls and floors have cold-formed steel (CFS) framing. This first edition contains mainly data for loadbearing steel framing formed from sheet steel with thickness from 1.37 mm (16 gauge) to 0.94 mm (20 gauge). Non-loadbearing CFS studs formed from thinner steel (nominally 0.54 mm) are also commonly used but these are not included in the data tables for sound transmission through wall assemblies in this Report.}, language = {en} } @techreport{HoellerMuellerTrapetKingetal., author = {H{\"o}ller, Christoph and M{\"u}ller-Trapet, Markus and King, Frances and Bradley, John}, title = {Evaluation of the communication performance of the C4 chemical, biological, radiological and nuclear mask}, doi = {10.4224/23003981}, abstract = {The Canadian Armed Forces (CAF) are using chemical, biological, radiological and nuclear (CBRN) general service respirators (GSRs) to defend against CBRN threats and hazards to protect personnel and ensure that they can safely and successfully carry out missions. The CBRN GSR currently in use by the CAF is the C4 respirator. The National Research Council of Canada assessed the communication performance of the C4 respirator. This report presents the results of the performance test. The method for assessing the communication performance used in this study was the NIOSH standard test procedure TEB-CBRN-APR-STP-0313 [1]. Other methods exist to evaluate the communication performance of respirators, but historically the NIOSH standard test procedure has been used. This report details the implementation and results of the tests conducted at the National Research Council of Canada, following the NIOSH standard test procedure.}, language = {en} } @techreport{HoellerQuirtMuellerTrapet, author = {H{\"o}ller, Christoph and Quirt, J. David and Mueller-Trapet, Markus}, title = {Apparent sound insulation in wood-framed buildings}, publisher = {National Research Council of Canada. Construction}, doi = {10.4224/23002820}, abstract = {This Report presents the results from substantial experimental studies of sound transmission, together with an explanation of calculation procedures to predict the sound transmission between adjacent spaces in a building with wood-framed walls and floors. This Report presents two types of experimental data for wood-framed constructions: - Test data for direct sound transmission through typical wood-framed wall assemblies and wood-framed floor assemblies, plus a summary of trends for such constructions and references to compilations of additional data - Test data for flanking sound transmission measured following the procedures of ISO 10848 for coupled wall/floor junctions and wall/wall junctions Worked examples for calculating the apparent sound transmission class (ASTC) rating between adjacent dwelling units are presented to illustrate how the experimental data can be applied.}, language = {en} } @phdthesis{Hoeller, author = {H{\"o}ller, Christoph}, title = {Indirect methods of obtaining activity and mobility of structure-borne sound sources}, publisher = {University of Liverpool}, address = {Liverpool}, abstract = {The work reported in this thesis focuses on the development of indirect methods for the experimental determination of important source parameters for structure-borne sound source characterization. In the first part of the thesis, matrix inversion methods for the determination of blocked forces are investigated. A simplified measurement procedure is proposed which offers a solution to the two major challenges to these methods, namely the acquisition of the FRF matrix and the problems associated with matrix inversion. The proposed procedure involves a free, low-mobility receiver plate which is modelled numerically. Calculated FRFs are used together with measured velocity responses to inversely determine the blocked forces. It is found that while the method has great potential in principle, in practice the accurate modelling of the receiver plate is of critical importance. In the second part of the thesis, three formulations are considered for the indirect determination of source mobility. Instead of performing measurements on the source in the free state, the source mobility is obtained from measurements made in-situ. This approach is beneficial if the source is difficult to suspend, or if it contains non-linear structural elements. The three formulations are validated numerically and experimentally. It is found that the methods can quantify source mobilities of single-contact and multi-contact sources from in-situ measurements. However, typical measurement errors, such as background noise or inaccuracies in sensor positioning, can significantly reduce the accuracy and reliability of the methods. In the final part of the thesis, the reception plate method for the determination of the power injected by a high-mobility source into a low-mobility receiver is reviewed, and a source substitution method proposed as a development. The substitution method circumvents problems that may arise when the reception plate method is applied to coupled walls and floors. A special focus of investigation is on the calibration of the receiver structure. It is found that the calibration can be performed with shaker or hammer, and that an average calibration factor may be used. The source substitution method thus offers a potential alternative to the reception plate method, for application with coupled plates.}, language = {en} } @article{LievensHoellerDietrichetal., author = {Lievens, Matthias and H{\"o}ller, Christoph and Dietrich, Pascal and Vorl{\"a}nder, Michael}, title = {Predicting the Interaction Between Structure-Borne Sound Sources and Receiver Structures from Independently Measured Quantities}, series = {Acta Acustica united with Acustica}, volume = {100}, journal = {Acta Acustica united with Acustica}, number = {1}, publisher = {European Acoustics Association (EAA)}, doi = {10.3813/AAA.918688}, pages = {79 -- 92}, abstract = {Structure-borne sound sources are usually characterised by their source activity and source mobility. By combining this data with the mobility of receiver structures it is theoretically possible to predict the sound pressure level in a building. In a case study of a washing machine on a wooden joist floor this prediction process was investigated. The prediction was based on the normal force component only. The contact area at the feet of the washing machine was made as small as possible to avoid the influence of moments while the in-plane components were assumed negligible. These conditions proved to allow for accurate predictions in the coupled state in a previous publication [1]. The results show that the prediction from independently measured normal source and receiver quantities yields large errors below 125 Hz as a consequence of the above assumption. Between 125 and 900 Hz the error of the prediction is within ± 5 dB. The case study further investigated two assumptions frequently encountered in practice: low and high-mobility sources and no cross-coupling between the feet}, language = {en} } @techreport{MahnQuirtHoelleretal., author = {Mahn, Jeffrey and Quirt, David and H{\"o}ller, Christoph and M{\"u}ller-Trapet, Markus}, title = {Addendum to RR-335: sound transmission through Nail-Laminated Timber (NLT) assemblies}, publisher = {National Research Council of Canada. Construction}, doi = {10.4224/40000417}, abstract = {This report is published as an addendum to NRC Research Report RR-335 "Apparent Sound Insulation in Cross-Laminated Timber Buildings." It is intended that this addendum will be merged with RR-335 in the future as a report for predicting the sound insulation in buildings using mass-timber constructions including NLT assemblies. This report presents the results from experimental studies of airborne sound transmission through assemblies of nail-laminated timber (NLT) with various linings. To put the data presented in this report in the proper context, this report begins with a brief explanation of calculation procedures to predict the apparent sound transmission class (ASTC) between adjacent spaces in a building whose structure is a combination of mass-timber assemblies such as nail-laminated timber (NLT) or cross-laminated timber (CLT) panels.}, language = {en} } @inproceedings{HoellerMahn, author = {H{\"o}ller, Christoph and Mahn, Jeffrey}, title = {The Measurement of the Total and Resonant Radiation Efficiencies for Lightweight Constructions}, series = {Taming Noise and Moving Quiet. 46rd International Congress on Noise Control Engineering (Internoise 2017), 27-30 August 2017, Hong Kong}, booktitle = {Taming Noise and Moving Quiet. 46rd International Congress on Noise Control Engineering (Internoise 2017), 27-30 August 2017, Hong Kong}, publisher = {International Institute of Noise Control Engineering (I-INCE)}, pages = {1931 -- 1937}, language = {en} } @inproceedings{Hoeller, author = {H{\"o}ller, Christoph}, title = {Review and Comparison of ASTM and ISO Standards on Sound Transmission in Buildings}, series = {Impact of noise control engineering : 47th International Congress and Exposition on Noise Control Engineering (INTERNOISE 2018) : Chicago, Illinois, USA, 26-29 August 2018}, booktitle = {Impact of noise control engineering : 47th International Congress and Exposition on Noise Control Engineering (INTERNOISE 2018) : Chicago, Illinois, USA, 26-29 August 2018}, publisher = {Curran Associates, Inc.}, address = {Red Hook, NY}, language = {en} } @inproceedings{HoellerQuirtZeitleretal., author = {H{\"o}ller, Christoph and Quirt, D. and Zeitler, Berndt and Sabourin, I.}, title = {Apparent sound insulation in cold-formed steel-framed buildings}, series = {24th International Congress on Sound and Vibration (ICSV 24), 23-27 July 2017, London, UK}, booktitle = {24th International Congress on Sound and Vibration (ICSV 24), 23-27 July 2017, London, UK}, publisher = {Curran Associates, Inc}, language = {en} } @inproceedings{HoellerZeitlerSchoenwald, author = {H{\"o}ller, Christoph and Zeitler, Berndt and Schoenwald, Stefan}, title = {Anwendung von Cremers parallelen Platten auf leichte Bauelemente}, series = {Fortschritte der Akustik - DAGA 2017 : 43. Deutsche Jahrestagung f{\"u}r Akustik, 6.-9. M{\"a}rz 2017 in Kiel}, booktitle = {Fortschritte der Akustik - DAGA 2017 : 43. Deutsche Jahrestagung f{\"u}r Akustik, 6.-9. M{\"a}rz 2017 in Kiel}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, pages = {521 -- 524}, language = {de} } @inproceedings{ZeitlerHoellerMahn, author = {Zeitler, Berndt and H{\"o}ller, Christoph and Mahn, Jeffrey}, title = {Empirical model of direct sound transmission through lightweight wood-framed construction}, series = {Implementing noise control technology : 44th International Congress and Exposition on Noise Control Engineering (Internoise 2015) : San Francisco, California, USA, 9 - 12 August 2015}, booktitle = {Implementing noise control technology : 44th International Congress and Exposition on Noise Control Engineering (Internoise 2015) : San Francisco, California, USA, 9 - 12 August 2015}, publisher = {Curran}, address = {Red Hook, NY}, abstract = {Tools to predict sound transmission through building elements are beneficial from both amarketing and a research standpoint. Prediction models can assist with the optimization ofelement performance and often reduce both cost and time in projects. However, the morephysical phenomena are to be included in the model, the more input data that is needed,which in some cases can be quite time-consuming and costly to collect. A balance is neededbetween the input and modeling effort and the output, which is usually delivered in onethird octave frequency bands or single number ratings. Many different types of models arecommonly used, including analytical, numerical, and empirical are used, all of which haveadvantages and disadvantages. In this paper, the latter type is presented using a set ofphysical properties of lightweight wood elements, and the errors made in the prediction arequantified. The disadvantage of empirical compared to analytical modeling is that thephysical phenomena are more difficult to identify. The advantage is often the simplicityand accuracy of the prediction results.}, language = {en} } @inproceedings{ZeitlerMahnSabourinetal., author = {Zeitler, Berndt and Mahn, Jeffrey and Sabourin, Ivan and H{\"o}ller, Christoph and Schoenwald, Stefan}, title = {Apparent airborne sound insulation of hybrid wood-concrete masonry assemblies}, series = {Euronoise 2015 : 10th European Congress and Exposition on Noise Control Engineering : Maastricht, 31 May - 3 June 2015}, booktitle = {Euronoise 2015 : 10th European Congress and Exposition on Noise Control Engineering : Maastricht, 31 May - 3 June 2015}, address = {Maastricht}, organization = {Belgian Acoustical Association (ABAV), Acoustical Society of the Netherlands (NAG), European Acoustics Association (EAA)}, pages = {2515 -- 2520}, abstract = {As part of a research project to develop design solutions for concrete-masonry buildings for the Canadian market, the apparent sound insulation performance of hybrid assemblies with concrete masonry walls and wood joist floors was evaluated. In this paper, the effect of junction coupling is investigated in an ISO 15712 flanking prediction context. Airborne flanking path data predicted according to ISO 15712 are compared to data measured using the indirect ISO 10848 shielding method. Recommendations are made on how appropriate the application of ISO 15712 is for this type of hybrid assembly.}, language = {en} } @article{HoellerGibbs, author = {H{\"o}ller, Christoph and Gibbs, Barry M.}, title = {Source substitution method for obtaining the power transmission from vibrating sources in buildings}, series = {Applied Acoustics}, volume = {141}, journal = {Applied Acoustics}, publisher = {Elsevier}, doi = {10.1016/j.apacoust.2018.07.014}, pages = {240 -- 249}, abstract = {This paper describes a method analogous to the airborne sound source substitution method, to estimate the vibrational power injected by a structure-borne sound source into the supporting building element. The injected vibrational power is required for prediction of the structure-borne sound pressure from vibrating equipment in buildings. The paper focuses on high-mobility sources connected to low-mobility receivers, a situation which is commonly encountered in heavyweight construction. The mobility mismatch simplifies the transformation of laboratory measurement data to prediction of transmitted power in-situ. Three case studies were performed. In the first study, the power injected by a simple test source into a resiliently supported aluminium plate was determined using direct and indirect methods. Source substitution was investigated with different calibration options: steady-state excitation, transient excitation, and spatial averaging. The source power could be determined within 4 dB, compared with direct measurements of the injected power. In the second study, the power injected by a second source into a concrete transmission suite floor was determined. The third study was of a combined heating and power unit on a masonry wall. In this study, a reference sound pressure level in a receiver room was calculated and compared with a criterion curve for the assessment of low-frequency noise complaints. The case studies demonstrate that structure-borne sound source substitution is a promising development of the reception plate method. While the latter can be used if a free reception plate is available, the former circumvents problems of determining the transmitted power into coupled plates and therefore has application to real building conditions. The use of the instrumented hammer for the calibration and the use of spatial averaging significantly simplify the method.}, language = {en} } @inproceedings{HoellerZeitler, author = {H{\"o}ller, Christoph and Zeitler, Berndt}, title = {Laboratory study on flanking sound transmission in cold-formed steel-framed constructions}, series = {Towards a quieter future : 45th International Congress and Exposition on Noise Control Engineering (Internoise 2016) : Hamburg, Germany, 21-24 August 2016, Vol 8}, booktitle = {Towards a quieter future : 45th International Congress and Exposition on Noise Control Engineering (Internoise 2016) : Hamburg, Germany, 21-24 August 2016, Vol 8}, publisher = {Curran Associates Inc.}, pages = {6238 -- 6249}, abstract = {In a recent study at the National Research Council Canada, the sound transmission in cold-formed steel-framed constructions was investigated. The results of direct sound insulation tests of wall and floor assemblies were reported at EURONOISE 2015 and INTERNOISE 2015. This paper focuses on flanking sound transmission in cold-formed steel-framed constructions. A representative full-scale mock-up specimen was constructed in NRC's 8-room flanking transmission facility. The specimen consists of four loadbearing walls with 152 mm deep steel studs, four non-loadbearing walls with 92mm deep steel studs, and four floor-ceiling assemblies consisting of steel joists and a composite steel deck with gypsum concrete. Measurements were conducted according to the indirect method described in ISO 10848. The individual flanking paths were measured by a sequence of transmission loss measurements in which other transmission paths were suppressed by shielding. For the bare specimen without linings, the sound transmission for horizontally adjacent rooms with continuous subfloors is dominated by the floor-floor flanking paths. Floor coverings or floor toppings are needed to meet the requirements in the National Building Code of Canada. This paper presents details of the measurements, highlights some of the results and discusses implications.}, language = {en} } @inproceedings{HoellerZeitlerMahn, author = {H{\"o}ller, Christoph and Zeitler, Berndt and Mahn, Jeffrey}, title = {Direct sound transmission loss of heavy gauge steel stud walls}, series = {Proceedings of Euronoise 2015 : 10th European Congress and Exposition on Noise Control Engineering : Maastricht, 31 May - 3 June 2015}, booktitle = {Proceedings of Euronoise 2015 : 10th European Congress and Exposition on Noise Control Engineering : Maastricht, 31 May - 3 June 2015}, address = {Maastricht}, pages = {1121 -- 1126}, language = {en} } @inproceedings{HoellerBloedtSchneider, author = {H{\"o}ller, Christoph and Bl{\"o}dt, Adrian and Schneider, M.}, title = {Kenngr{\"o}ßen elastisch gebundener Sch{\"u}ttungen auf Decken in Holzbauweisen}, series = {Fortschritte der Akustik DAGA 2022: 48. Jahrestagung f{\"u}r Akustik, 21. - 24. M{\"a}rz 2022, Stuttgart und Online}, booktitle = {Fortschritte der Akustik DAGA 2022: 48. Jahrestagung f{\"u}r Akustik, 21. - 24. M{\"a}rz 2022, Stuttgart und Online}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, address = {Berlin}, language = {de} } @inproceedings{BloedtHoeller, author = {Bl{\"o}dt, Adrian and H{\"o}ller, Christoph}, title = {Akustische Verbesserungsmaßnahmen an Stoßstellen im Holzbau}, series = {Fortschritte der Akustik DAGA 2022: 48. Jahrestagung f{\"u}r Akustik, 21. - 24. M{\"a}rz 2022, Stuttgart und Online}, booktitle = {Fortschritte der Akustik DAGA 2022: 48. Jahrestagung f{\"u}r Akustik, 21. - 24. M{\"a}rz 2022, Stuttgart und Online}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, address = {Berlin}, language = {de} } @inproceedings{HoellerSteffens, author = {H{\"o}ller, Christoph and Steffens, Oliver}, title = {Bauphysikalische Grundlagenausbildung an der OTH Regensburg w{\"a}hrend der COVID-19-Pandemie}, series = {Tagungsband DAGA 2021: 47. Jahrestagung f{\"u}r Akustik, 15.-18. August 2021, Wien und Online}, booktitle = {Tagungsband DAGA 2021: 47. Jahrestagung f{\"u}r Akustik, 15.-18. August 2021, Wien und Online}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V.}, isbn = {978-3-939296-18-8}, language = {de} } @inproceedings{RiegerHoeller, author = {Rieger, Anna and H{\"o}ller, Christoph}, title = {Aufbau eines Empfangsplattenpr{\"u}fstands an der OTH Regensburg}, series = {Fortschritte der Akustik - DAGA 2023, 49. Jahrestagung f{\"u}r Akustik, 06. - 09. M{\"a}rz 2023, Hamburg}, booktitle = {Fortschritte der Akustik - DAGA 2023, 49. Jahrestagung f{\"u}r Akustik, 06. - 09. M{\"a}rz 2023, Hamburg}, publisher = {Deutsche Gesellschaft f{\"u}r Akustik e.V. (DEGA)}, address = {Berlin}, pages = {274 -- 277}, language = {de} }