@article{LooNagarajuPathivadaetal., author = {Loo, Xuyan and Nagaraju, Bhavana and Pathivada, Sai and Bartsch, Alexander and Schratzenstaller, Thomas and Sattler, Robert and Monkman, Gareth J.}, title = {Electrical properties of bisphenol-A-free magnetoactive borosilicate polymers}, series = {AIP Advances}, volume = {14}, journal = {AIP Advances}, number = {5}, publisher = {AIP Publishing}, issn = {2158-3226}, doi = {10.1063/5.0203017}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-72936}, abstract = {The recent REACH regulations require the elimination of bisphenol-A and titanium dioxide from commercially available boron-based polymers. This has led to changes in some of the mechanical characteristics, which strongly influence the properties of magnetoactive borosilicate polymers. This work delivers results on the electrical properties and discusses some implications for future research using bisphenol-A and titanium-dioxide-free substitutes.}, language = {en} } @article{KleinFreimuthMonkmanetal., author = {Klein, Dagmar and Freimuth, Herbert and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and Meier, Alexander and B{\"o}se, Holger and Baumann, Michael and Ermert, Helmut and Bruhns, Otto T.}, title = {Electrorheological Tactile Elements}, series = {Mechatronics}, volume = {15}, journal = {Mechatronics}, number = {7}, publisher = {Pergamon}, address = {Oxford}, doi = {10.1016/j.mechatronics.2004.05.007}, pages = {883 -- 897}, abstract = {The use of ultrasound systems for medical examination and diagnosis is nothing new. The extension of ultrasound techniques for real time elastographic analysis purposes represents a more recent development. Nevertheless, as they stand all such techniques rely on the interpretation of two-dimensional visual data displayed on a video screen. In reality however, a medical doctor will make as much use of exploratory touch as he or she does vision, making the simultaneous portrayal of both video and tactile information most desirable [B{\"o}se H, Monkman GJ, Freimuth H, Ermert H. Haptisches Sensor-Aktor-System uaf der grundlage der Echtzeitelastographie sowie von elktro- und magnetorheologischen Materialien "HASASEM" [3]. BMBF Antrag 01 IR A14D, Oktober 2000]. This paper discusses the preliminary tests and basic design parameters for single tactels using electrorheological fluids. The final aim is to produce a prototype three-dimensional tactile display comprising electrically switchable micro-machined cells whose mechanical moduli are governed by phase changes experienced by electrorheological fluids. This will be integrated with the latest elastographic ultrasonic sensor systems in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone.}, language = {en} } @article{KleinRensinkFreimuthetal., author = {Klein, Dagmar and Rensink, D. and Freimuth, Herbert and Monkman, Gareth J. and Egersd{\"o}rfer, Stefan and B{\"o}se, Holger and Baumann, Michael}, title = {Modelling the Response of a Tactile Array using an Electrorheological Fluids}, series = {Journal of Physics D: Applied Physics}, volume = {37}, journal = {Journal of Physics D: Applied Physics}, number = {5}, publisher = {IOP Publ.}, address = {Bristol}, issn = {1361-6463}, doi = {10.1088/0022-3727/37/5/023}, pages = {794 -- 803}, abstract = {This paper reports the first step in the development of a tactile array suitable for the presentation of haptic information in virtual reality. The system is based on the electric field dependence of the viscosity of electrorheological fluids. The simulation, as well as the experimental realization of single tactels is described. The mathematical approach is based on the Eckart model (Eckart W 2000 Continuum Mech. Thermodyn. 12 341-62) and its validity is demonstrated by comparing the resulting yield stress with the experimental results from Wunderlich (2000 Dissertation Universit{\"a}t Erlangen-N{\"u}rnberg). Two different tactel designs are realized and the experimental results are compared with numerical simulation. The design of modification B is shown to be applicable for the realization of an actuator array with high spatial resolution.}, language = {en} } @inproceedings{DiermeierSindersbergerMonkman, author = {Diermeier, Andreas and Sindersberger, Dirk and Monkman, Gareth J.}, title = {Magneto-Active Polymer Actuator}, series = {Actuator 16 : 15th International Conference on New Actuators \& 9th International Exhibition on Smart Actuators and Drive Systems : conference proceedings}, booktitle = {Actuator 16 : 15th International Conference on New Actuators \& 9th International Exhibition on Smart Actuators and Drive Systems : conference proceedings}, publisher = {WFB}, address = {Bremen}, isbn = {978-3-933339-26-3}, pages = {286 -- 289}, abstract = {Magneto-active Polymers (MAP) are closely related to magneto-rheological fluids in that they contain magnetic micro-particles. However, instead of being freely suspended in a carrier fluid they are physically bound within a highly elastic polymer-matrix. The application of an external magnetic field allows changes in the mechanical properties, such as elastic and shear moduli, of the composite material to be achieved. The colossal magneto-rheological effect has been shown to demonstrate changes in Young's modulus by over 1E6 \%. Current research concentrates on controllable compliance and the resulting shape memory properties of MAP. This paper deals with recent advancements in this respect, including tubular magneto-active devices with potential applications in medical and other technology.}, language = {en} } @article{MonkmanBoody, author = {Monkman, Gareth J. and Boody, F. P.}, title = {Ein Vergleich verschiedene Master-Programme}, series = {Die Neue Hochschule}, journal = {Die Neue Hochschule}, number = {1}, publisher = {DUZ Verlags- und Medienhaus GmbH}, address = {Berlin}, pages = {12 -- 13}, language = {de} } @article{DillingerMayerSchneideretal., author = {Dillinger, Andrea Elisabeth and Mayer, Matthias and Schneider, Magdalena and Weber, Gregor R. and Goeppner, Corinna and Tamm, Ernst R. and Shamonin (Chamonine), Mikhail and Monkman, Gareth J. and Fuchshofer, Rudolf}, title = {Reactive changes in optic nerve astrocytes are mediated by CTGF, TGF beta 2 and increasing substratum stiffness}, series = {Investigative ophthalmology \& visual science}, volume = {56}, journal = {Investigative ophthalmology \& visual science}, number = {7}, publisher = {ASSOC RESEARCH VISION OPHTHALMOLOGY INC}, abstract = {Purpose: Patients with primary open-angle glaucoma (POAG) show a stiffer peripapillary sclera, reactive astrocytes and a remodeled lamina cribrosa (LC). The changes are thought to be mediated by TGFβ2 and its downstream mediator CTGF. Recently we developed a murine glaucoma model by overexpressing CTGF in the anterior eye (βb1CTGF). In this study we investigated the glial lamina region of βb1CTGF mice, and the changes of astrocytes in response to CTGF and TGFβ2 as well as increasing substratum stiffness. Methods: Tangential sections of the glial LC of 2-month-old βb1CTGF mice and their wild-type littermates (WT) were stained with phalloidin and antibodies against GFAP, CTGF and fibronectin (FN). Murine optic nerve (ON) astrocytes from CD1 mice were isolated, cultured and characterized by GFAP staining. The astrocytes were treated with TGFβ2 (1ng/ml) and CTGF (50ng/ml and 100ng/ml). In addition, the cells were seeded on PDMS substrata with different stiffness (10, 30 and 60 kPa). Treated cells were analyzed by Western blotting, real-time RT-PCR and immunohistochemistry. Wound healing assays were performed to analyze migration rate following growth factor treatment. Results: βb1CTGF mice showed a massive increase in CTGF and GFAP in the glial LC when compared with WT mice. Moreover, an increase in FN staining and phalloidin-labeled actin was observed in the peripapillary sclera. Murine ON astrocytes reacted on increased substrate stiffness by increasing the synthesis of GFAP, vimentin and CTGF. Treatment of the cells with TGFβ2 and CTGF led to an enhanced migration rate. In addition, treatment resulted in an increased expression and synthesis of ECM proteins, including FN, tropoelastin, collagen type I and III. The in vitro findings correlated with those seen in the glaucoma mouse model. Conclusions: We conclude that changes in the ECM of LC and peripapillary sclera alter their biomechanical properties and thereby induce reactive changes in resident astrocytes. The reactive changes induced by higher stiffness of their surrounding ECM give rise to a self-amplifying process that includes increased TGFβ2/CTGF signaling and leads to synthesis of ECM and cytoskeletal proteins, a process that in turn augments the stiffness at the optic nerve head (ONH). Such a scenario may finally result in a vicious circle as the causative mechanism for ONH deformation in POAG.}, language = {en} } @article{SorokinStepanovShamoninChamonineetal., author = {Sorokin, Vladislav V. and Stepanov, Gennady V. and Shamonin (Chamonine), Mikhail and Monkman, Gareth J. and Khokhlov, Alexei R. and Kramarenko, Elena Yu}, title = {Hysteresis of the viscoelastic properties and the normal force in magnetically and mechanically soft magnetoactive elastomers: Effects of filler composition, strain amplitude and magnetic field}, series = {Polymer}, volume = {76}, journal = {Polymer}, publisher = {Elsevier}, doi = {10.1016/j.polymer.2015.08.040}, pages = {191 -- 202}, abstract = {Hysteresis in dynamic modulus, loss factor and normal forces of magnetoactive elastomers (MAEs) comprising various proportions of small (3-5 mu m) and large (50-60 mu m) ferromagnetic particles are experimentally studied using dynamic torsion performed at a fixed oscillation frequency in varying DC magnetic fields. It is shown that hysteresis is a characteristic feature of MAEs observed both under increasing/decreasing magnetic field strength and increasing/decreasing strain amplitude. This hysteresis is attributed to the specific rearrangement of the magnetic filler network under simultaneously applied magnetic field and shear deformation. Rheological properties of the magnetic filler network formed in the magnetic field and, therefore, the rheological properties of MAEs depend strongly on the filler composition and the magnetic field magnitude. Larger magnetic particles and higher magnetic fields provide stronger magnetic networks. Both factors result in the extension of the linear viscoelastic regime to larger strain amplitudes and lead to higher values of shear storage and loss moduli. It is found that the hysteresis width maximises at an intermediate magnetic field where it is attributed to the balance between elastic and magnetic particle interactions. This is apparently where the most significant restructuring of the magnetic network occurs. The hysteresis width decreases with increasing fraction of large particles in the magnetic filler. The loss factor grows significantly when the magnetic network is physically broken by large strains gamma > 1\%. A huge (more than one order of magnitude) increase of normal force at maximum magnetic field strengths is observed. It is predicted that any physical quantity depending on the internal structuring of the magnetic filler should demonstrate hysteresis either with a changing magnetic field and constant deformation amplitude or under variable deformation in a constant magnetic field. (C) 2015 Elsevier Ltd. All rights reserved.}, language = {en} } @article{MonkmanSindersbergerDiermeieretal., author = {Monkman, Gareth J. and Sindersberger, Dirk and Diermeier, Andreas and Prem, Nina}, title = {The magnetoactive electret}, series = {smart materials and structures}, volume = {26}, journal = {smart materials and structures}, number = {7}, publisher = {IOP Publishing}, doi = {10.1088/1361-665X/aa738f}, abstract = {A magnet which adheres to every surface, not only those of ferromagnetic materials, has hitherto been the domain of science fiction. Now for the first time such a novel device exists. The fusion of a permanently magnetized magnetoactive polymer containing hard magnetic particles and an electret enhanced with ferroelectric particles has resulted in the development of a new smart device-the magnetoactive electret. Magnetoactive electrets can be made to exhibit the usual magnetic properties of permanent magnetism together with the electrostatic properties of electrets. This results in simultaneous magnetoadhesion and electroadhesion forces from the same elastomeric element. The biasing field, needed to avoid discontinuities concerned with transition through the zero point in operating curves, is normally provided by means of either a magnetic or an electric field. This novel technology provides both bias options in a single device.}, language = {en} } @article{MonkmanSindersbergerPremetal., author = {Monkman, Gareth J. and Sindersberger, Dirk and Prem, Nina and Diermeier, Andreas and Szecsey, Tamara}, title = {Dielectric behaviour of magnetic hybrid materials}, series = {Physical Sciences Reviews}, volume = {7}, journal = {Physical Sciences Reviews}, number = {10}, publisher = {de Gruyter}, doi = {10.1515/psr-2019-0121}, pages = {1169 -- 1185}, abstract = {The objectives of this work include the analysis of electrical and magnetic properties of magneto-elastic hybrid materials with the intention of developing new techniques for sensor and actuator applications. This includes the investigation of dielectric properties at both low and high frequencies. The behaviour of capacitors whose dielectrics comprise magnetic hybrid materials is well known. Such interfacial magnetocapacitance can be varied according to magnetic content, magnetic flux density and the relative permittivity of the polymer matrix together with other dielectric content. The basic function of trapping electrical charges in polymers (electrets) is also established technology. However, the combination of magnetoactive polymers and electrets has led to the first electromagnetic device capable of adhering to almost any material, whether magnetically susceptible or not. During the course of this research, in addition to dielectrics, electrically conductive polymers based on (PDMS) matrices were developed in order to vary the electrical properties of the material in a targeted manner. In order to ensure repeatable results, this demanded new fabrication techniques hitherto unavailable. The 3D printing of silicones is far from being a mature technology and much pioneering work was necessary before extending the usual 3 d.o.f. to include orientation about and diffusion of particles in these three axes, thus leading to the concept of 6D printing. In 6D printing, the application of a magnetic field can be used during the curing process to control the particulate distribution and thus the spatial filler particle density as desired. Most of the devices (sensors and actuators) produced by such methods contain levels of carbonyl iron powder (CIP) embedded magnetic filler of up to 70 wt\%. Contrary to this, a hitherto neglected research area, namely magnetoactive polymers (MAPs) having significantly lower magnetic particle concentrations (1 to 3 wt\% CIP) were also investigated. With filler concentrations lower than 3 wt\%, structures are formed which are completely absent at higher filler levels. CIP concentrations in the range of 1wt\% demonstrate the formation of toroidal structures. Further development of coherent rings with a compact order results as filler concentrations increase towards 2 wt\%. Above 3 wt\% the structure eventually disintegrates to the usual random order found in traditional MAP with higher CIP content. Structured samples containing 1\%-3 wt\% CIP were investigated with the aid of X-ray tomography where solitary ring structures can be observed and eventually the formation of capillary doubles. Over wavelengths ranging from 1 to 25 µm, spectroscopic analysis of thin film MAP samples containing 2 wt\% CIP revealed measurable magnetic-field-dependent changes in IR absorption at a wavenumber 2350 (λ = 4.255 µm). This was found to be due to the diamagnetic susceptibility of atmospheric carbon dioxide (CO2). Consequently, the first potential application for sparse matrix MAPs was found.}, language = {en} } @article{PremSindersbergerMonkman, author = {Prem, Nina and Sindersberger, Dirk and Monkman, Gareth J.}, title = {Mini-Extruder for 3D Magnetoactive Polymer Printing}, series = {Advances in Materials Science and Engineering}, journal = {Advances in Materials Science and Engineering}, publisher = {HINDAWI}, doi = {10.1155/2019/8715718}, pages = {1 -- 8}, abstract = {This work describes the development of a new miniature extruder, essential to cavity-free 3D printing of silicone-based smart materials. This makes the 3D printing of magnetoactive and electroactive polymer soft robotic components and devices directly from CAD data possible. The special feature of such an extruder is that it is designed for use with addition-crosslinking RTV-2 silicones, including solid particulate additives. The extruder merges the respective components automatically during extrusion which obviates the need for premixing and vacuum evacuation. Problems associated with inhomogeneities and unwanted cavity production are consequently eliminated. Rheological details necessary to the design, together with some preliminary performance results, are presented.}, language = {en} } @article{KreitmeierChashinFetisovetal., author = {Kreitmeier, Florian and Chashin, Dmitri V. and Fetisov, Yuri K. and Fetisov, Leonid Y. and Schulz, Irene and Monkman, Gareth J. and Shamonin (Chamonine), Mikhail}, title = {Nonlinear Magnetoelectric Response of Planar Ferromagnetic-Piezoelectric Structures to Sub-Millisecond Magnetic Pulses}, series = {Sensors}, volume = {12}, journal = {Sensors}, number = {11}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/s121114821}, pages = {14821 -- 14837}, abstract = {The magnetoelectric response of bi- and symmetric trilayer composite structures to pulsed magnetic fields is experimentally investigated in detail. The structures comprise layers of commercially available piezoelectric (lead zirconate titanate) and magnetostrictive (permendur or nickel) materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 µs and amplitudes ranging from 500 Oe to 38 kOe. The time dependence of the resulting voltage is presented and explained by theoretical estimations. Appearance of voltage oscillations with frequencies much larger than the reciprocal pulse length is observed for sufficiently large amplitudes (~1-10 kOe) of the magnetic-field pulse. The origin of these oscillations is the excitation of bending and planar acoustic oscillations in the structures. Dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated by digital signal processing and compared with those obtained by the method of harmonic field modulation. The results are of interest for developing magnetoelectric sensors of pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.}, language = {en} }