@article{SteiningerGadererSteffensetal., author = {Steininger, Peter and Gaderer, Matthias and Steffens, Oliver and Dawoud, Belal}, title = {Experimental and Numerical Study on the Heat Transfer Characteristics of a Newly-Developed Solar Active Thermal Insulation System}, series = {Buildings}, volume = {11}, journal = {Buildings}, number = {3}, publisher = {MDPI}, doi = {10.3390/buildings11030123}, pages = {1 -- 22}, abstract = {A newly-developed solar active thermal insulation system (SATIS) is introduced with the main objective to accomplish a highly-dependent total solar transmittance on the irradiation angle. SATIS is also designed to obtain the maximum transmittance at a prescribed design irradiation angle and to reduce it remarkably at higher irradiation angles. A purely mineral thermal insulation plaster with micro hollow glass spheres is applied to manufacture the investigated SATIS prototype. Light-conducting elements (LCEs) have been introduced into SATIS and suitable closing elements have been applied. The SATIS prototype has been investigated both experimentally and numerically. It turned out that the contributions of conduction, radiation and convection to the effective thermal conductivity of SATIS, without the closing elements (49 mWmK), amount to 86.2\%, 13.2\% and 0.6\%, respectively. The angle-dependent short-wave radiation exchange within the LCE has been investigated via ray tracing. At the incidence angle of 19\% (design angle), 27\% of the radiation within the LCE is absorbed by the absorber plate, resulting in measured and computed total solar energy transmittances of 11.2\%/11.7\%, respectively. For a typical summer irradiation angle of 60\%, 98\% of the incident radiation is absorbed by the surfaces at the entrance of the LCE. The corresponding total solar energy transmittance amounts to 2.9\%.}, language = {en} } @article{SteiningerGadererDawoudetal., author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal and Gaderer, Matthias}, title = {Experimental and numerical study on the solar gain and heat loss of typical existing and refurbished German buildings}, series = {iCRBE Procedia}, volume = {1}, journal = {iCRBE Procedia}, number = {1}, publisher = {Weentech}, doi = {10.32438/icrbe.202035}, pages = {75 -- 93}, abstract = {This communication introduces an experimental setup for investigating the effect of solar radiation on the reduction of transmission heat losses and the steady state thermal conductance of uninsulated and insulated multi-layer wall samples. The setup consists of two adjacent climatic chambers, which share a common wall, in which the multi-layer wall samples are mounted. A solar simulator is applied within the outdoor air climatic chamber, whose radiation spectrum and radiation intensity are approximately equivalent to those of the sun. The first tests have been carried out on a wall sample with a typical structure of existing buildings from the year 1930 in Germany. In addition, a high-performance insulating plaster layer has been applied on a basic test sample (with existing building structure) to replicate and assess the refurbished scenario. Furthermore, a numerical investigation on the transient heat transfer process is carried out by using the simulation software COMSOL Multiphysics®. The experimental results of both uninsulated and insulated wall samples are validated against 1D and 3D models. As seen, the uninsulated wall, whose thermal conductance was experimentally determined to be equal to 1.79 W/(m²K), absorbs a heat flux of 208 W/m² through its external wall surface over a period of 8 hours. A fraction of 9.8 \% of the absorbed heat arrives as a gain on the internal wall and reduces the transmission heat losses by 11.7 \% over a period of 55 hours. On the other hand, the thermal conductivity of the insulation layer of the refurbished wall sample with micro hollow glass spheres was estimated by a parameter estimation procedure using the 3D model and the obtained experimental data. Using the estimated thermal conductivity, a thermal conductance of 0.42 W/(m²K) has been obtained for the refurbished wall sample.}, language = {en} } @article{SteiningerGadererDawoud, author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal}, title = {Assessment of the Annual Transmission Heat Loss Reduction of a Refurbished Existing Building with an Advanced Solar Selective Thermal Insulation System}, series = {Sustainability}, volume = {13}, journal = {Sustainability}, number = {13}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/su13137336}, pages = {1 -- 19}, abstract = {A numerical parameter sensitivity analysis of the design parameters of the recently published solar selective thermal insulation system (SATIS) has been carried out to enhance its thermal and optical properties. It turned out that the insulation properties of SATIS can be effectively improved by reducing the length of the glass closure element. Increasing the area share of the light conducting elements (LCEs) and decreasing their length-to-diameter (L/D) ratio were identified as key parameters in order to increase the solar gain. Two SATIS variants were compared with the same wall insulation without SATIS in a yearly energetic performance assessment. The SATIS variant with 10 mm length of the closure element, 44.2\% area share of LCE, as well as front and rear diameters of 12 mm/9 mm shows an 11.8\% lower transmission heat loss over the heating period than the wall insulation without SATIS. A new methodology was developed to enable the implementation of the computed solar gains of SATIS in 1D simulation tools. The result is a radiant heat flow map for integration as a heat source in 1D simulation models. A comparison between the 1D and 3D models of the inside wall heat fluxes showed an integral yearly agreement of 98\%.}, language = {en} } @inproceedings{SteiningerGadererDawoud, author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal}, title = {Transient performance of a solar selective thermal insulation system}, series = {16th Advanced Building Skins Conference \& Expo, 21 - 22/10/2021, Bern, Switzerland}, booktitle = {16th Advanced Building Skins Conference \& Expo, 21 - 22/10/2021, Bern, Switzerland}, publisher = {Advanced Buidling Skins GmbH}, abstract = {A prototype of a thermal insulation system to offer high selectivity of the solar gain regarding the solar incidence angle (SATIS) was applied to a typical solid brick masonry for existing buildings in Germany. Light conducting elements (LCEs) inclined at 19 ° were incorporated in SATIS, which equals the average solar noon angle in southern Germany during winter. The entire wall construction was experimentally investigated in a differential climatic chamber test bench at four different irradiation angles according to a dynamic test procedure. In addition, a conventional wall construction (CWC) has been measured. At SATIS' design angle of 19 °, the SATIS wall construction shows a solar gain (SG) of 394.5 Wh/m², while the SG of the CWC amounts to only 25.4 Wh/m². The validated transient model of the SATIS wall construction showed that, at the end of the irradiation period of the dynamic test procedure (8 h), the solar heat penetrates to a depth of 253 mm and 111 mm inside the 385 mm thick brick wall masonry at the irradiation angles of 19 ° and 50 °, respectively. During the same time, the stored solar energy at 50 ° amounts to only 24.4 \% of that stored at 19 °.}, language = {en} } @article{SchwanzerSchillingerMieslingeretal., author = {Schwanzer, Peter and Schillinger, Maximilian and Mieslinger, Johann and Walter, Stefanie and Hagen, Gunter and Maerkl, Susanne and Haft, Gerhard and Dietrich, Markus and Moos, Ralf and Gaderer, Matthias and Rabl, Hans-Peter}, title = {A Synthetic Ash-Loading Method for Gasoline Particulate Filters with Active Oil Injection}, series = {SAR International Journal of Engines}, volume = {14}, journal = {SAR International Journal of Engines}, number = {4}, publisher = {SAE International}, issn = {1946-3936}, doi = {10.4271/03-14-04-0029}, pages = {493 -- 506}, abstract = {To reduce particulate emissions, the use of particulate filters in diesel engines is meanwhile state of the art, while the integration of such systems in gasoline engines is now also necessary in order to comply with today's regulations. Over its lifetime, a gasoline particulate filter (GPF) collects ash components of fuel, lubrication oil, and materials originating from the catalytic coating and from engine abrasion. In the development and application process, synthetic ashing from GPFs is challenging. The ash of the lubrication oil can be increased in various ways, like oil-doped fuel, a separate oil burner, or changes in the piston-cylinder system of the engine. However, these methods show major disadvantages. For this reason, an improved approach is presented in this study, which allows a quick response to changes in combustion (e.g., engine knocking) and producing ash, which is more realistic due to its primary particle size and the density of ash plugs, in a shorter time. Therefore, an approach to accelerate ash loading by active oil injection using a multi-point injection (MPI) system is introduced. With the help of this methodology, an ashing capacity of 1.21 g/h is implemented, which is a high rate compared to other investigations. The primary particle size (evaluated by means of a transmission electron microscope), is in the same size range as those detected at the full-load curve during regular operation. A computer tomographic (CT) analysis of the incinerated particulate filter also shows that a very high density of ash plugs can be realized, which has also been found in the literature for real applications. In addition, with the help of a mass spectrometer (MS) and an intermediate weighing of the particulate filter, the current ash loading of the GPF could be determined with an accuracy of 1\%.}, language = {en} } @article{SchwanzerRablLodersetal., author = {Schwanzer, Peter and Rabl, Hans-Peter and Loders, S. and Seifert, P. and Himmelstoss, S. and Gaderer, Matthias}, title = {Difference in the Tailpipe Particle Number by Consideration of Sub-23-nm Particles for Different Injection Settings of a GDI Engine}, series = {Emission control science and technology}, volume = {5}, journal = {Emission control science and technology}, number = {1}, publisher = {Springer Nature}, doi = {10.1007/s40825-019-0114-1}, pages = {7 -- 22}, abstract = {The purpose of this study was to investigate the characteristic of nanoparticles under consideration of sub-23-nm particles from a 1.8-l direct injection (DI) gasoline engine under stoichiometric air/fuel conditions in the exhaust gas system. For future CO2 challenges, the usage of DI-instead of port fuel injection (PFI)-gasoline engines is unavoidable. Therefore, a state of the art particle management program-particle number (PN) system, the Horiba SPCS (2100) with an integrated CPC (condensation particle counter), was recalibrated from a 50\% cutoff (D-50\%) at 23 nm down to a cutoff at 10 nm and the PCRF (particle concentration reduction factor) for sizes smaller than 23 nm was checked. Two different modal points, out of a representative Real Driving Emission (RDE) cycle, were investigated with both calibrations, D-50\%=10 nm and D-50\%=23 nm. For these different load points, the fuel pressure (FUP) and the start of injection (SOI) were varied, to represent the difference in the structure and the ratio conc((10 nm))/conc((23 nm)) of the nanoparticle emissions. The particle characterization includes the particle number (PN), the particle size distribution (PSD), and the particle mass (PM). The particle number was measured with Horiba SPCS (2100). The particle size distribution was analyzed with a Grimm differential mobility analyzer (DMA) in combination with a Faraday cup electrometer (FCE). Micro Soot and Pegasor were used to determine the PM, and an optical characterization was done with a 120-kV Phillips CM12 transmission electron microscope (TEM). The position of all particle measurement systems was downstream the three-way catalyst (TWC). The results of this investigation showed that a higher injection pressure decreases the PN (without consideration of sub-23-nm particles) in general. The ratio conc((10 nm))/conc((23 nm)) was therefore higher, because smaller particles, especially ash particles, were less reduced from the FUP. This means higher FUP tends to a higher ratio. For the SOI, the main reasons of the ratio differences were explained by an encroachment between the injection jet and the piston, the valve and the wall.}, language = {en} } @misc{SchwanzerMieslingerRabletal., author = {Schwanzer, Peter and Mieslinger, Johann and Rabl, Hans-Peter and Dietrich, Markus and Haft, Gerhard and Walter, Stefanie and Hagen, Gunter and Moos, Ralf and Gaderer, Matthias}, title = {Monitoring of a Particulate Filter for Gasoline Direct Injection Engines with a Radio-Frequency-Sensor}, series = {11th International Exhaust Gas and Particulate Emissions Forum, 3.-4.3.2020, Ludwigsburg, Germany}, journal = {11th International Exhaust Gas and Particulate Emissions Forum, 3.-4.3.2020, Ludwigsburg, Germany}, abstract = {In order to comply with future emission regulations, the use of particulate filters in vehicles with direct injection gasoline engines is essential. The current amount of soot and ash in the filter is calculated by a soot load model in the electronic control unit in combination with a differential pressure sensor determining the pressure drop over the particulate filter. Active regeneration is initiated if the calculated amount of soot or the measured differential pressure is too high. This is associated with additional fuel consumption. An on-board diagnosis for the particulate filter is currently not part of the Euro 6d emission standard. For future exhaust emission standards, on-board diagnosis or active monitoring of the particulate filter is conceivable. One of the benefits of monitoring is the fact that unnecessary active regenerations can be avoided. As a result, there is no additional fuel consumption due to misinterpretations of the amount of soot in the filter. For active monitoring of the particulate filter, a radiofrequency (RF-) sensor, that detects the soot loading of the filter with electromagnetic waves directly, can be used. Such a system has the advantage that by utilizing the filter as a sensor more precise information about the current state of the filter, e.g. a possible damage, can be provided. Worst-case considerations of filter damages, tested at an engine test bench show the advantages which are entailed by a system like that. By means of partial regeneration of the particulate filter it is demonstrated how the remaining amount of soot in the filter can be detected in a better way in comparison to the differential pressure sensor by using the RF-sensor.}, language = {en} } @misc{SchwanzerDietrichHaftetal., author = {Schwanzer, Peter and Dietrich, Markus and Haft, Gerhard and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Oxidation Kinetics Determination of GDI Engine Soot by a Radio-Frequency Sensor}, series = {23rd Conference on Combustion Generated Nanoparticles 2019, June 17-20, Z{\"u}rich, Switzerland}, journal = {23rd Conference on Combustion Generated Nanoparticles 2019, June 17-20, Z{\"u}rich, Switzerland}, language = {en} } @article{MikhaeilNowakPalombaetal., author = {Mikhaeil, Makram and Nowak, Sebastian and Palomba, Valeria and Frazzica, Andrea and Gaderer, Matthias and Dawoud, Belal}, title = {Experimental and analytical investigation of applying an asymmetric plate heat exchanger as an evaporator in a thermally driven adsorption appliance}, series = {Applied Thermal Engineering}, journal = {Applied Thermal Engineering}, number = {228}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2023.120525}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-61115}, abstract = {This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m-2∙K-1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake.}, language = {en} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {Experimental Investigation of the Adsorption and Desorption Kinetics on an Open-Structured Asymmetric Plate Heat Exchanger; Matching Between Small-Scale and Full-Scale Results}, series = {Frontiers in Energy Research}, volume = {10}, journal = {Frontiers in Energy Research}, publisher = {Frontiers}, doi = {10.3389/fenrg.2022.818486}, pages = {1 -- 15}, abstract = {This paper introduces the results of an experimental study on the adsorption and desorption kinetics of a commercially available, open-structured asymmetric plate heat exchanger adapted to act as an adsorber/desorber for the application in adsorption heat transformation processes. In addition, a volumetric large temperature jump (V-LTJ) kinetic setup was applied to measure the adsorption and desorption kinetics of a small-scale adsorbent sample prepared dedicatedly to be representative for the adsorbent domain inside the investigated adsorber plate heat exchanger (APHE). All kinetic results of the small-scale adsorbent sample and the APHE were fitted into exponential forms with a single characteristic time constant (τ) with a coefficient of determination (R2) better than 0.9531. A very good matching between the small-scale and full-scale adsorption kinetic measurements was obtained, with an average relative deviation of 12.3\% in the obtained τ-values. In addition, the kinetic data of the small-scale adsorbent sample were utilized for estimating the expected specific instantaneous and moving average powers of the evaporator/condenser heat exchanger. The average relative deviation (ARD) between the moving average specific evaporator powers obtained from the small-scale and the full-scale measurements amounts between 5.4 and 15.1\%.}, language = {en} }